FM2193

Reviews
Shared by: Muhammad Saleem
Categories
Tags
Stats
views:
58
rating:
not rated
reviews:
0
posted:
11/9/2007
language:
English
pages:
0
SECTION: 2.60.090 FM2193 0907 Supersedes 0307 MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347 SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961 (502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624 Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. visit our web site: www.zoeller.com THE “ZOELLER OIL SMART® SYSTEM” FOR SUBMERSIBLE DEWATERING APPLICATIONS APPLICATIONS: Designed to help protect the environment and equipment from the dispersion of oils and/or hydrocarbons. • Elevator Sumps • Transformer Vaults • Manufacturing Facilities SYSTEMS: • Operation of the Zoeller “Oil Smart® System” has been independently verified by OnSpeX, div. of CSA, when installed in accordance with our instructions. • Choose from four model pumps. Includes pump, switch and alarm (optional control panel). OIL SMART® SWITCH AND ALARM PANEL FEATURES: • Audible, light alarms and dry contacts. • Preset “on” and “off” points differentiate oil and water and alerts maintenance personnel of high water or oil detected conditions. • 20 ft. piggyback electrical supply cord. • 20 amp internal relay. • Alarm test and silence switches. • UL508 approved switch. Model 940-0005 shown. Product may not be exactly as shown. PUMP FEATURES: • Pumps are durable cast iron construction with powder coated epoxy finish and all stainless steel fittings. See back page for a list of pump catalog sheets. SIMPLEX PANEL FEATURES: • • • • • • • • • • • • Liquid Smart alarm switch. Oil Smart® pump switch. 115 volts, single phase. NEMA 4X watertight enclosure with lockable latch. 30 amp motor start relay. Pump HOA switch. Top mounted red alarm beacon light. 81 - 84 decibel rated alarm horn. Horn silence and alarm test switches. Alarm automatically resets. Dry auxiliary alarm contacts. Separate circuit protection for alarm. DUPLEX PANEL FEATURES: • Liquid Smart alarm switch. • Oil Smart® pump switch. • High liquid switch for high demand two pump operation. • 115 volts, single phase. • NEMA 4X watertight enclosure with lockable latch. • Two 30 amp motor start relays. • Pump HOA switches. • Top mounted red alarm beacon light. • 81 - 84 decibel rated alarm horn. • Horn silence and alarm test switches. • Alarm automatically resets. • Dry auxiliary alarm contacts. • Separate circuit protection for alarm. Model 10-2149 Model 10-2150 R R 229594 © Copyright 2007 Zoeller Co. All rights reserved. 229594 METERS FEET PUMP PERFORMANCE CURVE MODELS 57/152/153/161 60 55 18 TOTAL DYNAMIC HEAD/FLOW PER MINUTE EFFLUENT AND DEWATERING MODEL Feet Meters 5 1.5 10 3.0 15 4.6 20 6.1 25 7.6 30 9.1 35 10.7 40 12.2 50 15.2 Shut-off Head: 018939 16 50 14 45 40 35 10 30 8 25 20 15 4 10 2 5 57 0 10 GALLONS LITERS 0 40 80 120 160 200 240 280 320 360 400 20 30 40 50 60 70 80 90 100 110 152 153 161 57 Gal. Liters 163 43 129 34 72 19 ------------19.25 ft (5.9 m) 152 Gal. Liters 69 261 231 61 201 53 167 44 34 129 23 87 ------38 ft (11.6 m) 153 Gal. Liters 77 291 265 70 231 61 197 52 42 159 33 125 22 83 11 42 --44 ft (13.4 m) 161 Gal. Liters 100 379 352 93 322 85 299 79 70 265 62 235 54 204 45 170 20 76 56 ft (17 m) TOTAL DYNAMIC HEAD 12 6 Model 161 4 8 3/4 6 1/2 FLOW PER MINUTE Model 57 3 7/8 6 3/16 4 5/8 3 7/8 Model 152/153 6 7/32 4 5/8 4 3 7/8 3 7/8 3 7/8 3 7/8 1 1/2" NPT 1 1/2" NPT STANDARD 2" NPT OR 3" NPT AVAILABLE 18 9/16 12 1/8 10 1/16 5 3/8 6 SK2064 SK2644 3 3/32 SK1015 (See FM0493) (See FM1919) (See FM0460) COMPONENTS: Part Number 10-1526 10-1528 10-2149 10-2150 √ (included) BUILD YOUR OWN SYSTEM: Alarm Oil Smart® Panel Pump Switch √ --√ √ √ Description Oil Smart® Alarm Panel Oil Smart Pump Switch ® ® ® Liquid Smart High Water Alarm Switch Alarm Switch √ Nonauto Pump N57 N152 N153 Part Number 57-0002 152-0002 153-0002 Voltage 115 115 115 HP 3/10 4/10 1/2 Amps Hz 9.7 8.5 10.5 60 60 60 60 ---------√ --√ √ --√ √ Oil Smart Simplex Panel Oil Smart Duplex Panel N161 161-0002 115 1/2 10.5 (Or choose a prepackaged system, see below.) These systems are not designed for Explosion Proof Environments. Please consult factory for special options and requirements. CHOOSE A PREPACKAGED SYSTEM: Part Number 940-0005 940-0006 940-0007 940-0008 ® Description Oil Smart® Pump Switch and Panel Oil Smart Pump Switch and Panel Oil Smart® Pump Switch and Panel Oil Smart® Pump Switch and Panel Alarm Panel 10-1526 10-1526 10-1526 10-1526 Oil Smart® Nonauto Pump Switch Pump 10-1528 10-1528 10-1528 10-1528 N57 N152 N153 N161 Note: Other voltages and systems available. Contact factory for specifications. © Copyright 2007 Zoeller Co. All rights reserved. All installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be followed including the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).

premium docs
Other docs by Muhammad Salee...
The Social Media Manual - by Muhammad Saleem
Views: 3126  |  Downloads: 118
08-202_employment_application
Views: 622  |  Downloads: 11
02-63-Withdrawal-of-Counsel
Views: 742  |  Downloads: 0
10.01J Consent Agreement
Views: 629  |  Downloads: 1
10.01I Full Hearing CPO
Views: 699  |  Downloads: 1
10.01D Petition for CPO
Views: 580  |  Downloads: 1
11-DistressWarrantAffidavit
Views: 498  |  Downloads: 0
10-DispossessoryWritofPossession
Views: 452  |  Downloads: 0
09-DispossessoryWarrant
Views: 464  |  Downloads: 0
07-CertificationUnderRule3_2
Views: 450  |  Downloads: 0
05i-AnswerofContinuingGarnishment-Interactive
Views: 295  |  Downloads: 0
dv560
Views: 131  |  Downloads: 2
dv550infov
Views: 144  |  Downloads: 0
dv550infos
Views: 152  |  Downloads: 0
dv550infok
Views: 161  |  Downloads: 0