SECTION: 2.40.040
FM1702 0206 Supersedes 0305 MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347 SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961 (502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
visit our web site: www.zoeller.com
COMPARE THESE FEATURES
• FM listed motor for Class 1, Division 1, Group C & D environments. Not for use in acidic, methanol, or ethyl acetate atmospheres. • Non-clogging vortex impeller design bronze class 88-8-0-4. • Stainless steel rotor shaft. • Durable cast construction. Cast iron cover, motor adapter and pump housing. No sheet metal parts to rust or corrode. All cast iron class 30, 30000# tensile strength. • Stainless steel screws and handle. • 20 ft. UL Listed 5-wire (1 PH) or 8-wire (3 PH) neoprene cord. Extra cords lengths available in 25'-35'-50' length only. Sensor leads & power leads in one cord for easy installation. • 1¼" NPT threaded conduit connection for protecting cords in those extra heavy duty applications. • Moisture sensors prewired in motor housing (requires indicator in panel). • Zoeller custom designed panels with intrinsically safe relays and moisture indicator are required. • 3 phase models available. • Motor - 60 Hz, 3450 RPM, oil-filled, hermetically sealed, automatic reset thermal overload protected (3 phase requires circuit in control panel). • Maximum temperature for sewage or dewatering 104°F (40°C). • Shaft Seal - Stainless steel wetted parts, carbon & ceramic rotary face seal. • Upper ball bearing and lower ball bearing running in bath of oil. • Buna-n square ring seals. • All models pass 2" spherical solids. • Major width 135/16". Height 22". • Available in nonautomatic units only. • When ordering specify 2" or 3" NPT female flanged vertical discharge. • 100% computerized testing and 100% tested submerged in water. • Corrosion resistant powder coated epoxy finish.
Note: The sizing of sewage systems normally requires variable level float(s) controls and properly sized basins to achieve required pumping cycles.
X292 - X293 - X294 - X295
(For Pump Prefix Identification see News & Views 0052)
HIGH HEAD
EXPLOSION PROOF
SUBMERSIBLE
Standard 3600 & 3615
OR DEWATERING PUMP
SEWAGE
Nonautomatic Models for intrinsically safe variable level systems
*See back page For FM Listing.
© Copyright 2006 Zoeller Co. All rights reserved.
METERS
24
80 75
PUMP PERFORMANCE CURVE MODEL X292/X293/X294/X295
MODEL
Feet Meters 5 1.5 10 3.0 15 4.6 20 6.1 25 7.6 30 9.1 12.2 40 50 15.2 60 18.3 70 21.3 Shut-off Head:
FEET
X292
Gal. Liters 140 530 124 469 108 409 91 344 75 284 56 212 10 38 ------42 ft.(12.8m)
X293
Gal. Liters ----118 447 108 409 96 363 82 310 48 182 ------50 ft.(15.2m)
009919
X294
Gal. Liters 196 742 181 685 165 625 150 568 136 515 121 458 94 356 58 220 13 49 --62 ft.(18.9m)
X295
Gal. Liters 214 810 199 753 184 696 168 636 154 583 530 140 115 435 89 337 59 223 23 87 75 ft.(22.9m)
22 70 20 65 60 55 16 TOTAL DYNAMIC HEAD 50 14 45 40 35 10 30 8 25 20 15 10 2 5 X293
18
12
6
4
Model 293 should not be subjected to less than 15 feet TDH.
X295 X292 X294 10 20 80 30 40 160 50 60 240 70 80 320 90 100 110 400 FLOW PER MINUTE 120 130 480 140 150 560 160 170 640 180 190 720 200 210 800 220
0 GALLONS LITERS 0
Single Seal Weight - 125 lbs.
4 9/16 8 3/4 6 1/2
292 MODELS Single Seal NX292
Volts 115
Standard all models - 20 ft. cord - ½ H.P. Control Selection Ph Mode Amps Simplex 1 Non 15.0 1&3 Standard all models - 20 ft. cord - 1 H.P. Control Selection Ph Mode Amps Simplex 1 Non 10.2 1&3 1 Non 12.0 1&3 3 Non 7.6 1&3 3 Non 8.2 1&3 3 Non 4.0 1&3 3 Non 3.3 1&3
Duplex 1 & 3 or 2
Listing FM Y
4 9/16
293 MODELS Single Seal EX293 IX293 FX293 JX293 GX293 BAX293
Volts 230 200 230 200 460 575
Duplex 1 & 3 or 2 1 & 3 or 2 1&3 1&3 1&3 1&3
Listing FM Y Y Y Y Y Y
1 1/4" - 11 1/2 NPT
2" NPT OR 3" NPT AVAILABLE
CHECK VALVE
294 MODELS Single Seal EX294 IX294 FX294 JX294 GX294 BAX294
Standard all models - 20 ft. cord - 1½ H.P. Control Selection Volts - Ph Mode Amps Simplex 230 1 Non 13.7 1&3 200 1 Non 17.8 1&3 230 3 Non 9.5 1&3 200 3 Non 10.8 1&3 460 3 Non 4.8 1&3 575 3 Non 3.8 1&3 Standard all models - 20 ft. cord - 2 H.P. Control Selection Mode Amps Simplex Non 17.1 1&3 Non 20.5 1&3 Non 12.2 1&3 Non 14.3 1&3 Non 6.1 1&3 Non 4.9 1&3
Duplex 1 & 3 or 2 1 & 3 or 2 1&3 1&3 1&3 1&3
Listing FM Y Y Y Y Y Y
22
21 1/2
6
SK1914
SELECTION GUIDE
1. See FM1705 for correct intrinsically safe simplex or duplex panel. 2. Mechanical alternator “M-Pak” 10-0076 or 10-0077 (See FM1783). 3. Variable level control switch used as a control activator. Quantity required dependent upon panel selection.
295 MODELS Single Seal EX295 IX295 FX295 JX295 GX295 BAX295
Volts 230 200 230 200 460 575
Ph 1 1 3 3 3 3
Duplex 1 & 3 or 2 1 & 3 or 2 1&3 1&3 1&3 1&3
Listing FM Y Y Y Y Y Y
For information on additional Zoeller products refer to catalog on Duplex and Simplex controls, FM1705; Mechanical Alternator, FM0495; Sump/Sewage Basins, FM0487; and Rail Systems, FM0787.
All installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be followed including the most recent National Electric Code (NEC) and the Occupational Safety and Health Act (OSHA).
For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump.
© Copyright 2006 Zoeller Co. All rights reserved.
RESERVE POWERED DESIGN