					Tata Memorial Centre Advanced Centre for Treatment, Research and Education in Cancer Technical Specification of : Multichannel electronic pipettor: 12 channel Qty: 1 no.

Please quote all the models including the state of the art equipment which meets the basic minimum specifications Sr.no. Description of Item Model Name: Make: Ergonomic design, light weight Dispensing Volume Range: at least 10 to 100 microlitres per dispensing. 12-channel pipettor, air displacement type. Compatible with standard disposable tips. Following functions should be present: Selection of aspiration/dispensing volume. Single time aspiration of total volume and multiple/sequencial dispensing in fractions. LCD display for set parameters. Accessories to be supplied with pipettor: Suitable battery, its charger ( and pipettor stand, if separate than charger) 240 V AC ± 10 %, 50 Hz, single phase with inbuilt/ optional protection for high/low voltage Warranty: 2 years-on site Free Service: 5 years Compliance Yes No Remarks

1 2 3 4 5 A B C 6 A 7 8 9

Tata Memorial Centre Advanced Centre for Treatment, Research and Education in Cancer Technical Specification of : Liquid Nitrogen Container with square canisters Qty:1 no.

Please quote all the models including the state of the art equipment which meets the basic minimum specifications Sr.no. Description of Item Model Name: Make: Liquid Nitrogen capacity : approx. 47 ltrs Static evaporation rate: 0.39 ltrs/day (max.) 6 nos. of square canisters should be supplied with the container. Each square canister should hold 5 boxes, with capacity of 25 nos. of 1.2/2.0 ml vials in each box. 30 nos. of square boxes should be supplied with the container One spare neck tube should be supplied with the container It should confirm to the International safety requirements. (attach appropriate certification) Quote separately for LN2 container with around 80 Ltr. Capacity. Quote for complete set inculding square canisters, square boxes and Wheel trolley. Warranty: 2 years-on site Free Service: 5 years Compliance Yes No Remarks

1 2 3 4 5 6 7

8 9 10

Tata Memorial Centre Advanced Centre for Treatment, Research and Education in Cancer Technical Specification of : Tabletop Laboratory Centrifuge Qty: 1 no.

Please quote all the models including the state of the art equipment which meets the basic minimum specifications Sr.no. Description of Item Model Name: Make: rugged, compact and vibration free in construction. It should display actual run parameters like speed. equipped with safety feature of door interlock. It should have transparent lid for sample viewing. Timer: 0-60 min. timer control Max. speed achievable: around 5000-6000 rpm Following rotor should be supplied: Swinging bucket rotor with capacity of 8 x 15 ml A tubes. 240 V AC ± 10 %, 50 Hz, single phase with inbuilt/ optional protection for high/low voltage Warranty: 2 years-on site Free Service: 5 years Compliance Yes No Remarks

1 2 3 4 5 6

7 8 9

Tata Memorial Centre Advanced Centre for Treatment, Research and Education in Cancer Technical Specifications Of : Tabletop Refrigerated Centrifuge Qty: 1 no.

Please quote all the models including the state of the art equipment which meets the basic minimum specifications Sr.no. Description of Item Model Name: Make: Equipment should be a tabletop centrifuge with refrigeration facility. It should be electronically controlled, rugged in construction, quiet and vibration free in operation. It should have user console panel with digital display for set and run parameters. It should have settable sample temperature from at least +40C to ambient with accuracy error of at least +10C or better. It should have user settable parameters like time, temperature and speed. Timer requirement should be at least 1- 60 min and “Hold” mode. Achievable speed: 20,000 RPM (at least) and RCF = 33900 x g (at least) for 24 x 1.5 ml rotor. It should have a provision for door opening at the time of power failure.( Manual override for sample recovery in the event of power failure) PTO Compliance Yes No Remarks

1 2 3 4 5 6 7 8

9

Following rotor should be should be supplied:Type: Fixed Angle rotor Max. speed: 20000 RPM Max. RCF: 31300 x g Capacity: 24 x 1.5 ml / 2 ml tubes Quote optionally for the following rotors: A) all available rotors ( both fixed angle and swinging bucket) suitable for 15ml and 50 ml tubes. B)Rotor for 96 well microwell plate Equipment should have safety features like over speed sensor, rotor imbalance sensor, door interlock, over temperature cut-off, etc. 240 V AC ± 10 %, 50 Hz, single phase with inbuilt/ optional protection for high/low voltage Warranty: 2 years-on site Free Service: 5 years

10

11 12 13 14

Tata Memorial Centre Advanced Centre for Treatment, Research and Education in Cancer Technical Specification of : Single Channel Qty: 1 each variable volume pipettes Please quote all the models including the state of the art equipment which meets the basic minimum specifications Sr.no. Model Name: Make: 1 2 3 4 5 6 Ergonomic design, light weight Air displacement type, variable volume pipettes Rugged in construction. Colour coded push buttons Reduced pipetting and plunger force Volume range and quantity required:0.2 to 2.0 microlitre-- Qty:1 no. 2.0 to 20 microlitre-- Qty:1 no. 10 to 100 microlitre-- Qty:1 no. 20 to 200 microlitre-- Qty:1 no. 200 to 1000 microlitre-- Qty:1 no. 1000 to 5000 microlitre- Qty:1 no. Warranty: 2 years-on site Free Service: 5 years Description of Item Compliance Yes No Remarks

7 8

Tata Memorial Centre Advanced Centre for Treatment, Research and Education in Cancer Technical Specification of : Water Jacketed CO2 Incubator Qty: 1 no

Please quote all the models including the state of the art equipment which meets the basic minimum specifications Sr.no. Model Name: Make: 1 2 3 4 5 6 Water-jacketed incubator with adjustable levelling feet. Table model. Shelves and interior of good quality stainless steel. Interior of the chamber should be with totally curved corners. At least 4 adjustable shelves and one humidity pan to be supplied. Outer door insulated and with magnetic door gasket. Transparent inner door with leak proof and removable gasket . Heating for inner side of door . HEPA filtered airflow system in internal chamber. microprocessor controlled. Digital display for chamber temperature, CO2% and chamber % RH. User settable temperature and %CO2 values. Usable chamber capacity: 5 to 5.5 cu.ft Temperature range: ambient to 550C with +/0.10C accuracy error CO2 % range: 0-20% with less than 0.2% accuracy error Infra red CO2 sensor. Easily accessible water drain port at the bottom of the equipment. Easily accessible CO2 sampling port. Breathing port with filter. Safety indicators / Alarms required: Under and over temperature Low and high %CO2 level CO2 Tubing and start-up kit should be supplied PTO Description of Item Compliance Yes No Remarks

7 8 9 10 11 12 13 14 15 16 17 18

19

20 A B C D E 21 22 23

Quote optionally for the following accessories: Spare HEPA filters-2 nos In-line CO2 filter-1 Dual stage CO2 requlator-1 no. Spare CO2 sensor and control board. Spare blower motor / fan motor 240 V AC ± 10 %, 50 Hz, single phase with inbuilt/ optional protection for high/low voltage Warranty: 2 years-on site Free Service: 5 years

Tata Memorial Centre Advanced Centre for Treatment, Research and Education in Cancer Technical Specification of : Ultra Low Temperature Freezer (-86 deg. Cel.) Qty: 1 no

Please quote all the models including the state of the art equipment which meets the basic minimum specifications Sr.no. Model Name: Make: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Upright model with single door arrangement. Net chamber capacity: around 480 to 500 ltrs It should be mounted on 4 caster wheels. Operational temperature: settable between –500 C to - 860 C Four to five internal compartments with individual doors. Outer door locking facility with sturdy and rugged door handle Vacuum relief port for easy door opening. Microprocessor controlled system with user settable parameters. Digital display for internal temperature. inbuilt voltage compensation for incoming voltage Air cooled Refrigeration system with internal protection against over voltage and over current. Cascade refrigeration system with CFC free gases. Bottom mounted refrigeration system. ( not on the top of the freezer) Capability to hold internal temperature upto 4-5 hrs during prolonged power failure Battery backup for temperature display to show internal temperature at the time of power failure Overall freezer height should not be more than 78 inch. PTO Description of Item Compliance Yes No Remarks

17

It should have following safety alarms: A Audio-visual alarm for over temperature/under temperature. B Condenser hot alarm C Door open alarm D power failure alarm, etc 18 Quote optionally for the following /accessories / consumables : A Air filters - 2 nos. B Spare door handle-complete assembly. C Spare condenser fan motor 19 20 21 240 V AC ± 10 %, 50 Hz, single phase with inbuilt/ optional protection for high/low voltage Warranty: 2 years-on site Free Service: 5 years

Tata Memorial Centre Advanced Centre for Treatment, Research and Education in Cancer Technical Specification of : Inverted Microscope-for bright field and phase applications Qty: 1 no.

Please quote all the models including the state of the art equipment which meets the basic minimum specifications Sr.no. Model Name: Make: 1 Microscope should be with sturdy vibration free stand with Trinocular body. ( It should have separate port for camera attachment) Microscope should be configured for Bright field and Phase Contrast applications. Quoted model of Microscope should also be field upgradeable for fluorescence applications. It should be supplied with binocular tube with 10X wide view field eyepieces. It should be with quintuple nosepiece with 4X, 10x, 20x and 40x high-resolution plan Achromat, long working distance objectives suitable for bright field and phase applications. It should be with 12 V, 100W halogen lamp illumination and related hardware. It should incorporate compatible long working distance condenser suitable for bright field and phase applications. It should also incorporate essential attachments like phase slider, phase stop ph1, ph2, diaphragm etc. It should be with universal specimen stage ( approx. 210 x 290 mm) suitable for commonly available specimen holders, small and large petriplates, etc with x-y adjustments.(both coarse and fine) be supplied with neutral density filter, It should conversion filter, green filter etc. Microscope should be supplied with compatible Digital camera of min. 8 Mega pixel with 1 GB flash card. Suitable mount / coupling to connect to microscope should also be supplied. Camera should be able to upload images into computer through USB connectivity. Frame grabber card and software, if required, should also be supplied. PTO Description of Item Compliance Yes No Remarks

2

3 4

5 6

7 8

9 10

11

12 13 14

Following accessories to be supplied: a)Spare Halogen lamps-2 nos b)Dust Cover 240 V AC ± 10 %, 50 Hz, single phase with inbuilt/ optional protection for high/low voltage Warranty: 2 years-on site Free Service: 5 years

Tata Memorial Centre Advanced Centre for Treatment, Research and Education in Cancer Technical Specification of : Digital Vernier Caliper with computer interface Qty: 1 no.

Please quote all the models including the state of the art equipment which meets the basic minimum specifications Sr.no. Model Name: Make: 1 2 3 4 5 6 7 LCD display Battery operated. Hardened and tempered stainless steel with satin finish Measurement range: 0-150mm Zero setting control for comparative measurements Connectivity port for interfacing with computer for transferring data. Compatible data reading software should be supplied. It should read data from the caliper and transfer it to the EXCEL sheet. Warranty: 2 years-on site Free Service: 5 years Description of Item Compliance Yes No Remarks