									Production Timer System Wiring Diagram
CAT5 Cable

DSP253A & RYG16A ( x 3)

to 120VAC

DC
12VDC / 9A Symbol Technologies SYM04-1
CAT5 Cable

KT485A
4-Cond Stranded Unshielded cable with connector to 2-Cond Stranded Unshielded

CAT5 Cable

Connections: (4 Cond) (2 Cond) Red + Green to Red Black + White to White

Standard 4-Cond Phone Cord

4-Cond Crossover Phone Cord

to 120VAC

AC
12VAC / 20VA Amseco XF-1220

6-Cond Crossover Phone Cord

Wall Transformer

NOTE: For long distances, use 18GA or larger wire for the power wires (+V ,Gnd) See the wiring code book for details on wire specifications. Assume that the timer requires 100ma each. Assume that the displays require 500ma each. For exact current requirements on a particular model, contact Alzatex for details. Most displays require less than 500ma to operate. NOTE: Use twisted pair for the data signals (D-,D+). Use 22ga or larger for the data signals. In noisy environments, use shielded cable for the data signals. NOTE: A good quality 4 conductor 18GA or larger cable may be used provided that the group of four wires is twisted. TMR221ESM9_TMR231A_ProductionTimer 7/17/2008