Timekeeper_Wiring5 by alzatex

VIEWS: 69 PAGES: 6

A collection of Alzatex Manuals.

More Info
									TimeKeeper interconnection diagram
RYG Indicator
Start Stop

TimeKeeper

TX

RX

This document describes typical connector arrangements for some Alzatex products. It also includes the detailed wiring connections for serial connections and remote ground closure inputs used on Alzatex products. TimekeeperTM TMR-221 Connectors TimekeeperTM DA-216 Connectors RSSR
D2 D1 D3

Use Standard Phone Cord when connecting the TimeKeeper to a RYG display
Remote Display
Start Stop

Alzatex, Inc.
TX RX
www.alzatex.com

TimeKeeper

TMR-221D/SM8
D3-Tmr Start V+ Power D1-Stop,Down Ground D2-Reset D4-Tallye Up D3-TX V+

Use Standard Phone Cord when connecting the TimeKeeper to a remote display
Relay Module
Start Stop

RX

Rem
TX

+

TimeKeeper

TX

RX

RX

Alzatex, Inc.
www.alzatex.com

Use Standard Phone Cord when connecting the TimeKeeper to a relay module

D1-RX
Ground D2-Sync D3-RX V+

DA-216A0 Keypad

TX

Start Stop

TimeKeeper

TX

Start Stop

D1-TX
Ground D2-Sync

RX

TimeKeeper

Contains FCC ID: OUR-XBEE/OUR-XBEEPRO* The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any inter-ference received, including interference that may cause undesired operation.

Use Crossover Phone Cord when connecting two TimeKeepers together.
Distribution Box
Start Stop

AC 9-18 volts DC 11-20 volts

TimeKeeper

TX

RX

You will notice that some products have RS-422 jacks, some have RJ-11/14 jacks and some have both. Alzatex manufactures adapters to convert from one type to another.

Model RYG-400B0

Power In

Alzatex, Inc.

9-20 VAC or 12-24 VDC

Typical connection arrangements (above). Connectors for various controllers and displays (side, below)
DSP254 Display Connectors Alzatex, Inc.
www.alzatex.com

www.alzatex.com

RX-232

RX-422

DSP-504 display Connectors

DSP-254, DSP-256 display Connectors Alzatex, Inc.
www.alzatex.com

Alzatex, Inc.
www.alzatex.com
J3-RSSR D3 - Count Up D1 - Reset D2 - Stop/Down D4 - Start DE RX RX TX SYNC

Model DSP454-RYG RX RSSR TX
J3
D4 GND +V

Model DSP-500F0 RX RSSR TX
D4 GND +V D2-60 GND D1-TX +V D3-RX D2-60 GND D1-RX +V D3-TX

Model DSP-254/6E0
J3-RSSR D3 - Count Up D1 - Reset D2 - Stop/Down D4 - Start SYNC TX RX RX DE

J5
D2-60 GND D1-TX +V D3-RX

J2
D2-60 GND D1-RX +V D3-TX

J3

J5

J2

TEST
SYNC TX RX D2 D2 D2

D2 D1 D3

D2 D1 D3

DE IR D2 D2 D2

D2 D2 D2 IR DE

J1

J1

J6

J7

TEST
Power In

J6

J7

TEST

RX-422 TX-422 J1 = 9-18 VAC or 11-24 VDC Alzatex, Inc.

TX-422 RX-422 A4 J1 - AC-9-24 volts or DC-12-24 volts Www.alzatex.com

RSSR (J3) D3 - Count Up D1 - Reset D2 - Stop/Down D4 - Start

Power In (J1) = 9-20 VAC or 12-24 VDC

+

Use Crossover Phone Cord when connecting the TimeKeeper to a distribution box..

RYG-11 and RYG-400 Connectors

J1

RX-422 TX-422

+
D2-60 GND D1-TX +V D3-RX D2-60 GND D1-RX +V D3-TX D2 D1 D3

9-20 VAC 12-24 VDC
+
D4 GND +V

Antenna

TX-422 RX-422

Power In

D4 GND +V

+

+

+

+

RX

TX

RSSR

Timekeeper_Wiring5.pdf 11-7-2009

TimeKeeper interconnection diagram
TimekeeperTM 4 cond Crossover RJ-11 (5) YL (4) GN (3) RD (2) BK +12V Data GND Sync-60 OR/WH WH/BL BL/WH WH/OR RJ-11 (5) YL (4) GN (3) RD (2) BK Display 4 cond Standard

Wiring for permanent installations. TimekeeperTM s require crossover modular cords. Displays require standard modular cords. OR/WH WH/BL BL/WH WH/OR RJ-11 (5) YL (4) GN (3) RD (2) BK Display 4 cond Standard

NOTE: The +12V and Ground carry 1 amp to 2 amp of current. It is recommended that you double up pairs on the +12V and ground if using Cat-5 or use 18GA wire. The system may be powered from any device that has a power connector. When multiple devices are used, it is best to power the system from the device requiring the greatest amount of current. In large systems with many devices, a 12 volt DC power supply may be connected directly to the installed wiring. The master timing device will require an AC transformer to generate the Sync-60 signal.

OR/WH WH/BL BL/WH WH/OR

RJ-11 (5) YL (4) GN (3) RD (2) BK

TimekeeperTM 4 cond Crossover

OR/WH WH/BL BL/WH WH/OR

RJ-11 (5) YL (4) GN (3) RD (2) BK

Display 4 cond Standard

The TMR221 series has this 2x3 pin jumper arrangement
60 TX TX 60 TX TX 60 TX TX D2 D2 is connected to the 60HZ Sync (default) D2 RX Data port is Bi-Directional (default) D2 D2 D2 is connected to the serial data output RX D2 D2 D2 is connected to the serial data input RX

Most other products have this 2x3 pin jumper arrangement
D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 RX TX 60 D2 is connected to the 60HZ Sync (default) RX Data port is Bi-Directional TX 60 D2 is connected to the 60HZ Sync RX TX D2 is connected to the serial data output 60 RX D2 is connected to the serial data input TX 60

Alzatex, Inc.

Www.alzatex.com

Timekeeper_Wiring5.pdf 11-7-2009

TimeKeeper interconnection diagram
There are several ways to obtain bi-directional data transfer on a RJ-14 port. Connect the transmit port to the receive port or connect the receive port to the transmit port. TimekeeperTM Transmit port Beeper SYNC60Hz Ground TX Data +12V RX Data Data 4 Data 2 Ground Data 1 +12V Data 3 RJ-14 (1) WH (2) BK (3) RD (4) GN (5) YL (6) BL RJ-14 (1) WH (2) BK (3) RD (4) GN (5) YL (6) BL Display or adapter Receive Port Data 4 Data 2 Ground Data 1 +12V Data 3 — SYNC60HZ Ground RX Data +12V TX Data

6 cond Crossover

The TMR221 series has this 2x3 pin jumper arrangement
60 TX TX D2 D2 is connected to the 60HZ Sync (default) D2 RX

Most other products have this 2x3 pin jumper arrangement
D2 D2 D2 RX TX 60 D2 is connected to the 60HZ Sync (default)

There are several ways to obtain bi-directional data transfer on a RJ-14 port. In this arrangement, the 60HZ SYNC is not connected. TimekeeperTM Receive port — TX Data Ground RX Data +12V --Data 4 Data 2 Ground Data 1 +12V Data 3 RJ-14 (1) WH (2) BK (3) RD (4) GN (5) YL (6) BL RJ-14 (1) WH (2) BK (3) RD (4) GN (5) YL (6) BL Display or adapter transmit Port Data 4 Data 2 Ground Data 1 +12V Data 3 --RX Data Ground TX Data +12V —

4 cond Crossover

The TMR221 series has this 2x3 pin jumper arrangement
60 TX TX D2 D2 D2 is connected to the serial data output RX 60 TX TX D2 D2 D2 is connected to the serial data input RX

There are several ways to obtain bi-directional data transfer on a RJ-14 port. In this arrangement, the 60HZ SYNC is not connected. TimekeeperTM Transmit port — RX Data Ground TX Data +12V --Data 4 Data 2 Ground Data 1 +12V Data 3 RJ-14 (1) WH (2) BK (3) RD (4) GN (5) YL (6) BL RJ-14 (1) WH (2) BK (3) RD (4) GN (5) YL (6) BL Display or adapter transmit Port Data 4 Data 2 Ground Data 1 +12V Data 3 --TX Data Ground RX Data +12V —

4 cond Crossover

Most other products have this 2x3 pin jumper arrangement
D2 D2 D2 RX D2 is connected to the serial data input TX 60 D2 D2 D2 RX TX D2 is connected to the serial data output 60

Alzatex, Inc.

Www.alzatex.com

Timekeeper_Wiring5.pdf 11-7-2009

TimeKeeper interconnection diagram
Single Data Channel Timekeeper RS-422 Input or Output
Most products are configured for single data channel communication. Ground + Power Ground Data P Data N + Power Ground + Power RJ-45 (1) WH/OR (2) OR/WH (3) WH/GN (4) BL/WH (5) WH/BL (6) GN/WH (7) WH/BN (8) BN/WH TimekeeperTM
TM

8 cond Cat-5

Products that have a 2x6 pin jumper block Products that have a 2x2 pin jumper block NOTE: Products that do not have jumpers use the above configuration.

Dual Data Channel Timekeeper RS-422 Input and Output
For bi-directional data communication, some products can be configured for dual channel communication Ground + Power Data 2N Data 1P Data 1N Data 2P Ground + Power RJ-45 (1) WH/OR (2) OR/WH (3) WH/GN (4) BL/WH (5) WH/BL (6) GN/WH (7) WH/BN (8) BN/WH TimekeeperTM

TM

8 cond Cat-5

Products that have a 2x6 pin jumper block

Single Data Channel Timekeeper RS-485 Bi-Directional
Useful for systems having many devices that need to be addressed individually. Ground + Power Ground Data P Data N + Power Ground + Power RJ-45 (1) WH/OR (2) OR/WH (3) WH/GN (4) BL/WH (5) WH/BL (6) GN/WH (7) WH/BN (8) BN/WH TimekeeperTM

TM

8 cond Cat-5

Products that have a 2x6 pin jumper block Products that have a 2x2 pin jumper block

Alzatex, Inc.

Www.alzatex.com

Timekeeper_Wiring5.pdf 11-7-2009

Remote Button Wiring
Tallye Down Timer Start Timer Stop Tallye Reset Timer Reset Tallye Up To Remote Input on Timer

RJ-11 Jack

6 cond modular crossover cord

Red Timer Stop White Timer Start Yellow Timer Reset

Tallye Down ---Tallye Reset

3-RD

1-WH

5-YL

RJ-11 Jack
4-GN 6-BL 2-BK

(6) Up (5) Reset (4) Ground (3) Stop/Dn (2) +V (1) Start

6 cond modular crossover cord

Black Blue Green

+Voltage ---Ground

+Voltage Tallye Up Ground

Timekeeper Remote Ground Closure Inputs Setup as a Counter
Tallye Up Reset Ground Tallye Down +12V --TM

TM

Data 4 Data 2 Ground Data 1 +12V Data 3

RJ-11 (1) WH (2) BK (3) RD (4) GN (5) YL (6) BL

TimekeeperTM 6 cond Standard

Timekeeper Remote Ground Closure Inputs Setup as a Timer
--Reset Ground Timer Stop +12V Timer Start Data 4 Data 2 Ground Data 1 +12V Data 3 RJ-11 (1) WH (2) BK (3) RD (4) GN (5) YL (6) BL TimekeeperTM 6 cond Standard

Alzatex, Inc.

Www.alzatex.com

Timekeeper_Wiring5.pdf 11-7-2009

Cable Adapters and Power Supplies
Alzatex provides adapters to convert from one cable type to another. They can also provide extra power for larger systems. Normal phone cord is used for short distances, up to about 50 feet, while CAT-5 cable is used for longer distances or for units requiring higher power. The diagrams below show typical configurations for these adapters.
Crossover Phone Cord Cat-5 Cable
RS-232 TX RX TX RX RS-422

TX
Start Stop

PS422A2
Power In

88:88

RX-422

TimeKeeper

12VAC 20VA
Wall Transformer

Cat-5 Cable
TX RX RS-422

PS422DB9
Power In

88:88

RX-422

DB-9 In

Serial Cable

Computer

12VAC 20VA
Wall Transformer

Normal Phone Cord

PS232DB9
Power In

88:88

TX RX RS-232

RX-232

DB-9 In

Serial Cable

Computer

12VAC 20VA
Wall Transformer

Alzatex, Inc.

Www.alzatex.com

Timekeeper_Wiring5.pdf 11-7-2009


								
To top