Basis of Calibration #1

  What is Calibration?
    Calibration Program is used to adjust a hardware
     characteristic that is specific to each phone. (tuning the all
     the parameters to access the hardware)
    Through this the mobiles can operate in the most optimized
     condition
  Equipments
    PC : Microsoft Windows Base
    Wireless Communication Test Set : HP8922, HP8960,
     CMU200
    Programmable Power Supply : GPIB Programmable E3632A,
     HP6632, IPS 18B10, HP66311B
    GPIB(General Purpose Interface Bus) Card
    JIG Converter
    RS232 cable
      – 9 pin RS232 cable(connects PC with JIG)
      – 25pin RS232 cable(connects Mobile with JIG)

 GSM S/W                            3
Basis of Calibration #2

  Equipment Settings
                                                               HP-8960/
                                                               CMU200/
                                                               HP-8922


       RF Cable


                                                  GPIB Cable
                                                               GPIB
                                                               Card



                                                     E-3632


                                               Power Cable




                  Serial Cable(25Pin)      JIG            Serial Cable(9Pin)
                                        Converter
                                                     UART 0


 GSM S/W                                      4
Features of E800N/E820N Calibration #1
 TAT (Test for Automated Test) Mode
   Booting Modes
     – Normal : For Use MS Naturally
     – TAT mode : For Test of MS
 PC  MS Interface with DLLs(Dynamic Linked
 Library)
   SL : Under Layer
     – Manages Communication Layer over the Serial Link
     – Formats the Messages
   DV
     – Manages the Service Level, Uses the SL
   It must be updated to match with Target Source




GSM S/W                         5
Features of E800N/E820N Calibration #2
  Dynamic Tx Power Calibration
    Normal Calibration

 Tx
        5(0)
Level          …     5(1)   …    5(2)   6(0)    …   6(1)     …   6(2)    … …               …             …
                                                                                   19(0)         19(1)       19(2)




   Dynamic Calibration                         : HP 8960 and CMU200 only

 Tx
          5(0) x 5          6(0) x 5                                    5(1) x 5      6(1) x 5
Level                                   …                                                                …                …
                                                 19(0) x 5                                                    19(1) x 5




GSM S/W                                                      6
Features of E800N/E820N Calibration #3
 Use Parameter file I/O
   For Easy Tuning of Specifications
     - RadioSetting.dat : GSM,DCS Band Center Frequency and
       BCCH channel number
     - TxParam.dat : Default Tx Power, DAC, H0, Tru, Trd
     - HammCoeff.dat : Burst Shape Parameters
     - Dbm2Dac.dat : Variation of Tx Power(dBm) per
       1 Dac
     - LcdContrast.dat : Main Lcd Brightness, Sub Lcd
       Contrast
     - HwVersion.dat : Hardware Version Setting
     - CalSpec.dat : Calibration Conditions in the Battery,
       Rx and Tx
     - LineSetting.dat : Factory Line Number setting
     - MsInitTimeOut.dat : Time Out constant
     - EquipmentSetting.dat


GSM S/W                     7
Usage of Program #1
 1. Com Port Setting




          Select COM Port
            On your PC




GSM S/W                     8
Usage of Program #1-1
 1-1. Mode Selection




GSM S/W                9
Usage of Program #2
 2. Environment Setting
                                    For
                               Production Line




Set Radio ENV
                                     Line
                                 Information




                               Set Default
                               LCD Value




GSM S/W                   10
Usage of Program #3
 3. Program Main




          Com Port Monitor


GSM S/W                      11
Usage of Program #4
 4. Menu Structure
   4.1 Production
     –    Board & Battery
     –    Calibration RF
             › Normal Mode - Reserved
             › Dynamic Mode
     –    All Calibration
             › Board & Battery + RF
   4.2 RF Control

   4.3 Base Band

   4.4 Memory

   4.5 Battery




GSM S/W                                 12
Usage of Program #5
 5. RF Control
    5-1. Tx
     Calibration




 Dbm/Dac:
 Power increasing By 1 DAC
 :It Take into account of Cal Speed


GSM S/W                               13
Usage of Program #6
                                          Being H0 Calibration
   5-1-1. Execute Tx Cal
  (Hamming Cal : E638 Only)



Being TX Power Calibration




     TX Power Calibration Finished

GSM S/W                              14
Usage of Program #7
   5-2. Rx Calibration




GSM S/W                   15
Usage of Program #8
   5-3. Set Default Radio Parameter
     – Set Radio Parameters to Default
       Values



   5-4. APC DAC Read
     – View Tx Power DAC Values




GSM S/W                           16
Usage of Program #8
 6. Base Band
   6-1. RS-232C
     – Serial Link Test

   6-2. RTC Time Set
     – Set PC Time to MS

   6-3. H/W Version
     – R/W Hardware Version

   6-4. Lcd Test
     – Set Lcd Contrast Value

   6-5. Cal All baseband
     – All of above + Memory Test




GSM S/W                             17
Usage of Program #9
 7. Memory
   7-1. RAM Test
      – get the RAM test result




   7-2. FLASH Test
      – check the flash




   7-3. Full Reset




GSM S/W                           18
Usage of Program #10
 8. Battery
   8-1. ADC Read
     – Read Current ADC Value
     – ADC1 : Voltage
     – ADC3 : Temperature


   8-2. Battery Calibration
     –    1.Set EEP to Start ADC Value
     –    2.Set Power Supply 3.35V
     –    3.Read ADC
     –    4.Set Power Supply 4.2 V
     –    5.Read ADC
     –    6.Write New Value to EEP



   8-3. Flash ADC Read
     – Read Battery ADC Values




GSM S/W                                  19
GSM S/W   20

				
DOCUMENT INFO
Shared By:
Categories:
Tags:
Stats:
views:4
posted:5/19/2013
language:
pages:20