DCN Central Control equipment - Starin by pptfiles

VIEWS: 3 PAGES: 22

									             Security Systems BU Communication Systems

             Central Control Equipment




                                           LBB3500/05

                                                         LBB3508/00


LBB4106/x0



 01.Nov.06    DCN SA PO CCE                                    ST/SEU-CO 1
            Security Systems BU Communication Systems

            Central Control Unit (Com - port 1)            LBB3500/05


                                               9-pin Sub-D connector
                                                RS 232 for:
                                                   Terminal mode

                                                      Factory testing

                                                      Diagnostics

                                                        OR
                                                      Camera Control




                     1




01.Nov.06    DCN SA PO CCE                                        ST/SEU-CO 2
            Security Systems BU Communication Systems

            CCU Trunk Communication Board (TCB-4)
                                      1 Jumper X14 for service only
                                      2 S14 DIP- switches 1 – 8 Com-port settings
                                      3 S10 Push- button switch to reset the
                                        Central Control Unit during servicing.
                                      4 Three LEDs (left to right) green/ yellow/
                                        red. Normally the green/ yellow LEDs flash
                                        in sequence, indicating the software is
                                        running. Red LED illuminates during
                                        system reset.
                                      5 S9 DIP- switches 1 – 8 System modes
                                      6 Yellow LED indicates Digital Signal
                                        Processing (DSP) software is running.
                                      7 Connector for multi- trunk board (used only
                                        in the multi- CCU)
                                      8 Sockets for inserting flash EPROM (even)
                                      9 Sockets for inserting flash EPROM (odd)




01.Nov.06    DCN SA PO CCE      Upgrade Kit                                  ST/SEU-CO 3
            Security Systems BU Communication Systems

            CCU Trunk Communication Board (TCB-4)
                                      10 SRAM back- up battery 3.6 V
                                         (life- time 5 years min.)
                                      11 Jumper X13 Battery back up
                                      12 Fuse 3.15 amp (delayed)
                                      13 Connector for multi- trunk board
                                         (used only in the multi- CCU)
                                      14 Serial RS232 Port 1
                                      15 Serial RS232 Port 2




01.Nov.06    DCN SA PO CCE      Upgrade Kit                                 ST/SEU-CO 4
            Security Systems BU Communication Systems

            Central Control Unit (Com - port 1)                              LBB3500/05
                             CCU Protocol and Serial Port settings
                             - Protocol based for using Allegiant Video Switchers.
                             For location of DIP- switches see;
                             Table 4.5 and 4.6
                             LBB 3500/ 05 Port 1 for Camera Control
                             In a single (stand- alone) CCU system only one
                             COM- port (Port 1) is available:
                             Default settings are;
                             • 8 data bits
                             • No parity check
                             • 1 Stop bit
                             Installation
                             The maximum cable length between the CCU and the ‘Allegiant
                             Video Switcher’ should not exceed 5 m (16.4 ft). Where longer
                             distances are required an ‘current-loop interface unit’ should be
                             used to ensure correct transmission.




01.Nov.06    DCN SA PO CCE        I&O Manual                                            ST/SEU-CO 5
            Security Systems BU Communication Systems

            TCB-4 DIP Switch Settings




                             (default)




01.Nov.06    DCN SA PO CCE               I&O Manual     ST/SEU-CO 6
            Security Systems BU Communication Systems

            Central Control Unit (Audio I/O)             LBB3500/05


                                             1. Asymmetrical Recorder
                                                In- & Outputs

                                    2
                                             2. 2 Asymmetrical line
                                                input connectors
            1
                                             3. Symmetrical or
                                                2 Asymmetrical line
                                3
                                                outputs




01.Nov.06       DCN SA PO CCE                                    ST/SEU-CO 7
            Security Systems BU Communication Systems

            Central Control Unit (Audio I/O)                       LBB3500/05


            1. Tape/cassette recorder input and output (Cinch-type)
               Tape In Asym.         nom. -33 dBV             max. -3 dBV
               Tape Out Asym.        nom. -33 dBV             max. -3 dBV


            2. 2 Asymmetrical line input connectors (Cinch-type)
               Line In Asym.        nom. -18 dBV             max. +12 dBV


            3. Symmetrical/Asymmetrical line output connectors (Cinch-type)
               Line Out Sym.        nom. -12 dBV             max. +18 dBV
               Line Out Asym        nom. -18 dBV             max. +12 dBV




01.Nov.06    DCN SA PO CCE                                                  ST/SEU-CO 8
            Security Systems BU Communication Systems

        Central Control Unit                               LBB3500/05
        (Trunk Outlets)

                                         1. Red LED overload
                Trunk                       indicators
                                         2. Trunk outlet used for
                                            loop-through of the
                                            trunk-line-cable




                                 2
                             1

01.Nov.06    DCN SA PO CCE                                          ST/SEU-CO 9
            Security Systems BU Communication Systems

            Central Control Unit                            LBB3500/05
            (Trunk Outlets)


                                    Trunk outlets
                                    For loop-through of the DCN
 PCF = 60 max.                     trunk-line without regenerating
                                    the digital signal.
                                    Power handling capacity
 PCF = 90 max.                     maximum:
                                    - 60 PCF per outlet
                                    - 90 PCF total for the three
                                    outlets of the CCU.




01.Nov.06    DCN SA PO CCE                                            ST/SEU-CO 10
            Security Systems BU Communication Systems

            Central Control Unit                                                 LBB3500/05

                                1. Mains socket with built-in fuse

                                                                          Nominal
                                Mains voltage         Mains fuse          Power Consumption
                                220, 230, 240 V AC.   T- 2A (slow blow)            175 W
            115V-T4A/230V-T2A
                                105, 115 V, 125 V AC. T- 4A (slow blow)


                                Warning:
                                All units must be powered via an earthed mains outlet.

                   1




01.Nov.06     DCN SA PO CCE                     I&O Manual                                 ST/SEU-CO 11
            Security Systems BU Communication Systems

            Extension Power Supply                        LBB4106/x0


                                             Rear view
                                 3   4       1. Trunk line cable
                                             2. Overload indicators
                                             3. Trunk outlets
                                             4. Mains socket


             1
                             2




01.Nov.06    DCN SA PO CCE                                       ST/SEU-CO 12
            Security Systems BU Communication Systems

            Extension Power Supply                         LBB4106/x0
            (Trunk outlet / Tap-off ’s)

                                             1.Red LED overload
            Trunk                Tap-off       indicators
                                             2.Trunk outlet used for
                                               loop-through of the
                                               trunk-line-cable
                                             3.Tap-off outlets are used
                                                for trunk-cable splitting




                      1      2      3


01.Nov.06    DCN SA PO CCE                                         ST/SEU-CO 13
            Security Systems BU Communication Systems

            Extension Power Supply                                     LBB4106/x0
            (Trunk outlet / Tap-off ’s)

                              Trunk outlet
                              For loop-through of the DCN trunk-line without
                              regenerating the digital signal.
            PCF = 60 max.    Power handling capacity maximum:
                              - 60 PCF per outlet
                              - 180 PCF total for the three outlets of the EPS.
                              Tap- offs
                              For Trunk-cable splitting with regenerating the digital
                              signal.
                              Power handling capacity maximum
            PCF = 180 max.
                              - 60 PCF per outlet
                              - 180 PCF total for the three outlets of the EPS.




01.Nov.06    DCN SA PO CCE                                                      ST/SEU-CO 14
            Security Systems BU Communication Systems

            Extension Power Supply                                               LBB4106/x0

                                1. Mains socket with built-in fuse

                                                                          Nominal
                                Mains voltage         Mains fuse          Power Consumption
                                220, 230, 240 V AC.   T- 4A (slow blow)            350 W
            115V-T4A/230V-T2A
                                105, 115 V, 125 V AC. T- 5A (slow blow)


                                Warning:
                                All units must be powered via an earthed mains outlet.

                   1




01.Nov.06     DCN SA PO CCE                     I&O Manual                                 ST/SEU-CO 15
            Security Systems BU Communication Systems

            Audio Media Interface                         LBB3508/00


                                            Rear view
                           2   3   5   6    1. Cinch Audio output sockets
                                            2. XLR Audio output sockets
                                            3. Trunk line cable
                                            4. Overload indicators
                                            5. Trunk outlets
                                            6. Mains socket
                       1           4




01.Nov.06    DCN SA PO CCE                                       ST/SEU-CO 16
            Security Systems BU Communication Systems

            Audio Media Interface                               LBB3508/00
            (Audio outputs)


                                                    1. 4 Asymmetrical Audio
            Output 1 Output 2   Output 3 Output 4
                                                       output connectors
                                                       (Cinch-type)
                                                    2. 4 Symmetrical
                                                       (transformer balanced)
                                                       Audio output sockets
                                                       (3-pin XLR)



             1      2



01.Nov.06    DCN SA PO CCE                                             ST/SEU-CO 17
            Security Systems BU Communication Systems

            Audio Media Interface                                     LBB3508/00
            (Audio outputs Levels)

           4 Asymmetrical audio output          Nom.      Max. .
               Interpreter floor & language     -10 dBV   - 10 dBV
               Multiple floor and line output   -19 dBV   +11 dBV
               Delegate loudspeaker channel     -10 dBV   + 2 dBV

           4 Symmetrical Audio output           Nom.      Max. .
               Interpreter floor & language     +1 dBV    + 1 dBV
               Multiple floor and line output   - 8 dBV   +22 dBV
               Delegate loudspeaker channel     +1 dBV    +13 dBV




01.Nov.06     DCN SA PO CCE                                                ST/SEU-CO 18
            Security Systems BU Communication Systems

            Audio Media Interface                         LBB3508/00
            (Trunk outlet / Tap-off ’s)

                                             1.Red LED overload
            Trunk                Tap-off       indicators
                                             2.Trunk outlet used for
                                               loop-through of the
                                               trunk-line-cable
                                             3.Tap-off outlets are used
                                                for trunk-cable splitting




                     1       2      3


01.Nov.06    DCN SA PO CCE                                         ST/SEU-CO 19
            Security Systems BU Communication Systems

            Audio Media Interface                                LBB3508/00
            (Audio outputs)

                                Trunk outlet
                                For loop-through of the DCN trunk-line without
                                regenerating the digital signal.
        PCF = 60 max.
                                Power handling capacity maximum:
                                - 60 PCF per outlet
                                - 90 PCF total for the three outlets of the AMI.
                                Tap- offs
                                For Trunk-cable splitting with regenerating the
                                digital signal.
        PCF = 90 max.          Power handling capacity maximum
                                - 60 PCF per outlet
                                - 90 PCF total for the three outlets of the AMI.




01.Nov.06    DCN SA PO CCE                                               ST/SEU-CO 20
            Security Systems BU Communication Systems

            Audio Media Interface                                                LBB3508/00

                                1. Mains socket with built-in fuse

                                                                          Nominal
                                Mains voltage         Mains fuse          Power Consumption
                                220, 230, 240 V AC.   T- 2A (slow blow)            175 W
            115V-T4A/230V-T2A
                                105, 115 V, 125 V AC. T- 4A (slow blow)


                                Warning:
                                All units must be powered via an earthed mains outlet.

                   1




01.Nov.06     DCN SA PO CCE                     I&O Manual                                 ST/SEU-CO 21
            Security Systems BU Communication Systems

            Central Control Equipment

            End of section
             Robert Bosch GmbH
            All rights are reserved. Reproduction or passing on to
            third parties in whole or in parts is prohibited without the
            written consent of the copyright owner.




01.Nov.06    DCN SA PO CCE                                                 ST/SEU-CO 22

								