sA MATERIAL SAFETY DATA SHEET
Section 1 - Product and Company Identification
Product Name: µPage 3, 5 & 10 Starter Kit Capillaries
Agilent Part Number: 191-1311; 191-3211; 191-5211; 192-1311; 192-3211; 192-5211
Date Revised: 5/23/03 Date of Original: 03/14/02 Number of Pages: 4
Manufacturer's Name: Agilent Technologies, Inc.
2850 Centerville Road
Wilmington, Delaware 19808
USA Emergency Telephone No: 1-302-633-8899
USA Information Telephone No: 1-877-4Agilent
European Information Telephone No.: (7243) 602-0
European Emergency Telephone Number: 0049 (0)6151/722440
When Calling From Outside the USA, Dial Your International Access Code for the USA,
then 1, then 302-633-8000
Section 2 - Composition/Information on Ingredients
Kits containing gel-filled capillaries; oliogonucleotides standards and buffer
solutions in varying concentrations and amounts (See MSDS for buffer solutions on
page 2):
Agilent Part Number Product Name Amount
590-4002 µPage-3&5 Oligo 50µL
590-4003 µPage-3&5 Buffer 2x237ml
590-4004 µPage-3&5 Buffer 30ml
590-4105 µPage-10 Buffer 2x237ml
590-4106 µPage-10 Oligo 50µL
590-4107 µPage-10 Buffer 30ml
___________________________________________________________________________________________
DISCLAIMER: This Material Safety Data Sheet is offered without charge to the clients of
Agilent Technologies. Data is the most current available to Agilent Technologies at the
time of preparation and is issued as a matter of information only, no warranty as to its
accuracy or completeness is expressed or implied.
1
sA MATERIAL SAFETY DATA SHEET
Section 1 - Product and Company Identification
Product Name: µpAGE 3%,5% & 10% Buffer Solutions
Agilent Part Numbers: 590-4001; 590-4003; 590-4004; 590-4005; 590-4105; 590-4107
Date Revised: 11/25/02 Date of Original: 07/18/01 Number of Pages: 3
Manufacturer's Name: Agilent Technologies, Inc.
2850 Centerville Road
Wilmington, Delaware 19808
USA Emergency Telephone No: 1-302-633-8899
USA Information Telephone No: 1-877-4Agilent
European Information Telephone No.: (7243) 602-0
European Emergency Telephone Number: 0049 (0)6151/722440
When Calling From Outside the USA, Dial Your International Access Code for the USA,
then 1, then 302-633-8000
Section 2 - Composition/Information on Ingredients
Buffer solutions in varying concentrations and amounts containing the following non-
hazardous ingredients:
Tris(hydroxymethyl)aminomethane [77-86-1] 1.05%
Boric Acid [10043-35-3] 0.54-1.60%
Urea [57-13-6] 36.52%
Water [7732-18-5] 60.83-61.89%
Chemical Families: Buffer Solution
Chemical Synonyms: Boric acid is also known as Boracic acid; Borofax; Boron
trihydroxide; Orthoboric acid; and Trihydroxyborane. Tris(hydroxymethyl)aminomethane
is also known as DDEX-THAM; 2-Amino-2-(hydroxymethyl)Propane-1,3-Diol; 2-Amino-2-
(Hydroxymethyl)-1,3-Propanediol; 2-Amino-2-methylol,3-propanediol;
Aminotrimethylolmethane; Aminotris(hydroxymethyl)methane;
1,1,1-tris(Hydroxymethyl)methylamine; Tham-Tham Set; Trimethylolaminomethane; TRIS
(Buffering Agent); Trisamine; TRIS-Amino; Trisaminol; TRIS Buffer;
Tris(hydroxymethyl)methanamine; and Tris(hydroxymethyl)methylamine. Urea is also
known as Carbamide, Carbamamimidc acid; Carbonyl diamide, Carbonyldiamine, Isourea,
and Pseudourea.
Section 3 - Hazards Identification
There are no hazardous concentrations of ingredients in this preparation; however
this material may cause skin, eye and mucous membrane irritation if mist is inhaled,
ingested or absorbed through the skin.
Section 4 - First-Aid Measures
Inhalation: If inhaled move affected person to fresh air
Skin Contact: May be harmful by skin absorption.
Eye Contact: Irrigate with water
Ingestion: NA
Section 5 - Fire-Fighting Measures
Extinguishing Media: Not flammable
Special Fire Fighting Procedures: NA
Unusual Fire and Explosion Hazards: NA
Section 6 - Accidental Release Measures
NA
Section 7 - Handling and Storage
Avoid contact with eyes. Store in a cool dry place.
___________________________________________________________________________________________
DISCLAIMER: This Material Safety Data Sheet is offered without charge to the clients of
Agilent Technologies. Data is the most current available to Agilent Technologies at the
time of preparation and is issued as a matter of information only, no warranty as to its
accuracy or completeness is expressed or implied.
2
sA Agilent Part Number: 590-4001; 590-4003; 590-4004; 590-4005; 590-4105; 590-4107
Section 8 - Exposure Controls/Personal Protection
Ventilation: NA
Respiratory: NA
Eyes: Safety glasses are considered minimum protection.
Skin: NA
Section 9 - Physical and Chemical Properties
Flash Point (Method Used): NA
Explosion Potential: LEL (NA) / UEL (NA)
Specific gravity: 1.2
Melting Point (Degree C): NA
Evaporation Rate (n-butyl acetate =1 ) NA
Freezing Point (Degree C): -14
Boiling Point (Degree C): 104
Vapor Pressure (mm Hg at 25 oC): approx. 17.5
Vapor Density (Air =1) 1
Volatility: approx. 60%
Odor Threshold: ND
PH: 8.20 - 9.05
Solubility in Water: Insoluble (NA)/Soluble(X)
Appearance and Odor: Clear liquid, pleasant odor
Section 10 - Stability and Reactivity
Stability: Stable ( x ) / Unstable ( )
Conditions to Avoid: NA
Incompatibility (Materials to Avoid): NA
Hazardous Decomposition or Byproducts: NA
Hazardous Polymerization: May Occur ( ) / Will Not Occur ( x)
Section 11 - Toxicological Information
Route(s) of Entry: Inhalation? No Skin? No Ingestion? No
Health Hazard Acute/Chronic: NA
Carcinogenicity: NTP? No
IARC Monographs? No
OSHA Regulated? No
OTHER? No
Medical Conditions Generally Aggravated by Exposure: NA
Section 12 - Ecological Information - Not Applicable
Section 13 - Disposal Considerations
Observe all Federal, State and Local environmental regulations
Section 14 - Transport Information
DOT Regulations:
Shipping Name: Not Regulated
IATA-DGR Regulations:
Shipping Name: Not Regulated
RID/ADR: NA
ADNR: ND
Section 15 - Regulatory Information
SARA Reporting: NA
OSHA Labeling Requirements: NA
TSCA Inventory List: All ingredients are on the list
TSCA 12(b) Notification List: No ingredients are on the list
3
sA
Agilent Part Number: 590-4001; 590-4003; 590-4004; 590-4005; 590-4105; 590-4107
Section 16 - Other Information
Unless otherwise noted, the above information pertains only for the solvent and similar
types of components in the sample. Furthermore, since individual chemical
hypersensitivity cannot be predicted, every chemical should be handled with due respect.
KEY TO ABBREVIATIONS
ACGIH - American Conference of Governmental Industrial Hygienists`
ADNR - Regulations concerning the carriage of dangerous goods on the Rhine
CAS - Chemical Abstract Service
DOT – U.S. Department of Transportation 49 Code of Federal Regulations
IARC - International Agency for Research on Cancer
IATA-DGR - International Air Transport Association- Dangerous Goods
Regulation
LEL - Lower Explosion Limit
NA - Not Applicable
ND - No Data
NIOSH - National Institute for Occupational Safety and Health
NTP - National Toxicology Program
OSHA - Occupational Safety and Health Administration
PEL - Permissible Exposure Limit
RID/ADR - Regulations Concerning the International Carriage of
Dangerous Goods by Rail/European Agreement Concerning the
International Carriage of Dangerous Goods by Road
TLV - Threshold Limit Value
TWA - Time Weighted Average
UEL - Upper Explosion Limit
[ ] - Indicates CAS Number