                          1. Kia Vehicle Diagnosis
                          2. Vehicle Scope meter
                          3. System Setup
                          4. Optional Items
                          5. PC-Scan
  Hi-Scan Pro Application



1. Kia Vehicle Diagnosis
   1.1 DIAGNOSIS TROUBLE CODE

   1.2 FREEZE FRAME DATA

   1.3 CURRENT DATA

   1.4 MONITERING TEST RESULT

   1.5 EVAP. LEAKAGE TEST

   1.6 FLIGHT RECORD

   1.7 DUAL DISPLAY

   1.8 SIMU-SCAN
     Hi-Scan Pro Application


 1.1 DIAGNOSIS TROUBLE CODE ( 1/5)
To get started. Following procedures are within KIA VEHICLE DIAGNOSIS mode
                                          On the Hi-Scan Pro keyboard;
                                          •Press “ON/OFF” button to turn on the Hi-Scan Pro
                                          •Keep on press “Enter” button until Initial screen come up.
                                          •Make sure DLC cable is properly connected.




                               ENTER
                                                           FIRST : SELECT VEHICLE
                                       ENTER                         DIAGNOSIS
                                                           SECOND : SELECT VEHICLE
                                               ENTER       THIRD : SELECT SYSTEM
                                                           FOURTH : SELECT VEHICLE
                                                                         YEAR
    Hi-Scan Pro Application



1.1 DIAGNOSIS TROUBLE CODE (2/5)
  To view Diagnostic Trouble code.




     ENTER                           ENTER
                                                After Selecting the vehicle model
                                                 year, go through the Diagnostic
                                                 Trouble Code and Current data to
                                                 diagnose the vehicle.

                                                If ECM or communication WIRE
                                                 has problem, Hi-Scan Pro cannot
                                                 communicate with vehicle and
                              OR                 display the message as shown in
                                                 picture.
    Hi-Scan Pro Application



1.1 DIAGNOSIS TROUBLE CODE (3/5)
 To check Diagnostic Trouble Code



   ENTER                            ENTER




                                                If ECM has no trouble code with
                                                 engine system, Hi-Scan Pro display
                                                 on the screen
                                                “NO TROUBLE CODE”

                                                If ECM has trouble code with engine
                              OR
                                                 system, Hi-Scan Pro display
                                                “TROBLE CODE WITH ITEM”
    Hi-Scan Pro Application



1.1 DIAGNOSIS TROUBLE CODE (4/5)
  To get information about DTC and delete DTC

                                 HELP : Basic & Major information to help understand
                                          each trouble code and item
                                 ERAS : Erase Trouble Code(Follow the instruction
                                          carefully)




           F1 HELP                                                     F2 ERAS
     Hi-Scan Pro Application


1.1 DIAGNOSIS TROUBLE CODE (5/5)
   To check the data of sensor with DTC when DTC is occurred.

                                FREZ : Display the data of items with DTC at the situation
                                     when trouble is occurred.
                                Hi - Scan display “FRZE” data only when ECM support
                                    this function.
                                PART : Precise diagnosis for each sensor(Oscilloscope)



             F3 FRZE                                               F6 PART
    Hi-Scan Pro Application


1.2 FREEZE FRAME DATA
  To check the data of sensor with DTC when DTC is occurred.
                                                                           Previous menu
                                                                                        ENTER

                                                                                                ENTER


                                                                                                    ENTER
                              Press “ENTER” with the cursor on “02.
                              FREEZE FRAME DATA” in “1. KIA                                                 ENTER
                              VEHICLE DIAGNOSIS” mode.
                              In this case, connect with vehicle via DLC
                              cable.




                                                                            FREZ : Display the data of items
                                                                                with DTC at the situation
                                 ENTER
                                                                                when trouble is occurred.
                                                                            Hi - Scan display “FREZ” data
                                                                                only when ECM support
                                                                                this function.
    Hi-Scan Pro Application



1.3 CURRENT DATA (1/2)
 To view the sensor and actuator data.
                                                Select “CURRENT DATA” in “KIA VEHICLE
                                                DIAGNOSIS” mode.
                                                In this case, connect with vehicle via DLC cable.
                              ENTER



                                                       FIX    : Fix current data and display
                                                              on the top of the screen
                                                       PART : Precise diagnosis for sensor
                                                              with inverted letters(Oscilloscope)
                                                       FULL : Display full 22 items’ data

             F1 FIX                   F2 PART                    F3 FULL
     Hi-Scan Pro Application



1.3 CURRENT DATA (2/2)
  To view the sensor and actuator data.


                                                       HELP : Provide reference data
                                                       GRPH : Waveform graph display
                                                       RCRD : Record sensor data




               F4 HELP                    F5 GRPH                         F6 RCRD
    Hi-Scan Pro Application


1.3 CURRENT DATA - PART
 To analyze part precisely.
                                                                           Previous menu
                                                                                           ENTER

                                                                                                   ENTER


                                                                                                           ENTER

                              Connect a probe to “CH A” of Hi-Scan Pro
                                                                                                               ENTER
                              •Go through the appropriate mode and press
                              “ENTER” on “03. CURRENT DATA”.                                                       ENTER

                              •Press “F2” button to operate “PART”
                              function.




                                                                               PART : Place a box, in which
                                                                              letters are inverted, and press
                              F2 PART                                         “PART” for precise part analysis.
                                                                               Connect a Test Probe to Channel
                                                                              A of Hi-Scan Pro.
                                                                               Oscilloscope mode begin as
                                                                              shown in the picture.
    Hi-Scan Pro Application


1.3 CURRENT DATA - GRAPH
 To view the pattern of sensor or actuator data                            Previous menu
                                                                                           ENTER

                                                                                                   ENTER


                                                                                                           ENTER


                              On a “CURRENT DATA” mode, press                                                  ENTER
                              “F1” to fix the items and “F5” to view the
                              graph.                                                                               ENTER




                                                               FIX : Select the sensors to view “GRAPH”
                                                               GRPH : Waveform graph display
                 F1 FIX
                                                                               FIX : Select the sensors to fix at
                                                                                the top of the screen.
                                                                                You can change the sensor by
                              F5 GRPH                                           pressing FIX button again.
                                                                                You can scroll up and down
                                                                                without moving fixed sensor.
    Hi-Scan Pro Application

                                                                 Previous menu
1.3 CURRENT DATA - RECORD                                                        ENTER

 To record the sensor or actuator data.                                                  ENTER


                                                                                                 ENTER


                                                                                                     ENTER
                               On a “CURRENT DATA” mode, press
                               “F6” to record a data.                                                    ENTER




                                                                    RCRD : Move to “RECORD” mode,
                                                                     in which select trigger type.
                                                                    AUTO TRIGGER(ANY DTC) :
                                                                     Triggers with any DTC.
                                                                    AUTO TRIGGER(SINGLE DTC) :
                                                                     Trigger with single user specified
                                                                     DTC.
                              F6 RCRD                               MANUAL TRIGGER : User trigger
                                                                     the data recording.
                                                                    FLIGHT RECORD DATA REVIEW :
                                                                     Fetch recorded data.
    Hi-Scan Pro Application


1.3 CURRENT DATA – AUTO TRIGGER (ANY DTC) (1/2)
 Record a data using AUTO TRIGGER.
                                                                    Previous menu
                                                                               ENTER
                                                                                       ENTER
                                                                                               ENTER
                                                                                                       ENTER
                                                                                                               ENTER

                                                                                                                       ENTER
                              After “TRIGGER TYPE” is chosen,
                              Select memory location using “▲””▼”
                              buttons and press enter.


                                     TYPE ID

                                                        ENTER
  AUTO TRIGGER                                                                 ENTER : Select the memory
    (ANY DTC)
                                                                                location then press “ENTER” to
                                                                                type memory ID.
                                                                               Type “CAR ID”.
                                                                               ENTER : Go to “DATA
                                                                                RECORD” select mode.
                                  ENTER                                         Select the “DATA RECORD” type
                                                                                and press “ENTER”.
     Hi-Scan Pro Application


1.3 CURRENT DATA – AUTO TRIGGER (ANY DTC) (2/2)
 Choose items to record: all or custom.




                      “01” ENTER           ALL DATA RECORD
                                            : Record all sensor data




                                          USER SELECT DATA RECORD.
                                           : Record user defined sensor data.


                                           FIX : Select sensors to record in ‘USER

                                                 SELECT DATA RECORD”.

                                           ENTER : Start “RECORDING”
                     “02” ENTER
                                           ESC :”STOP” recording
     Hi-Scan Pro Application


1.3 CURRENT DATA – AUTO TRIGGER (SINGLE DTC)
 Enter specific DTC which will be used as trigger.




                                                      AUTO TRIGGER(SINGLE DTC)
                                                        : Record user defined single DTC.
                                                      Type specific “DTC CODE” and
                                                       press “ENTER”.
                                                      Rest of procedures are same as
               ENTER                                   “AUTO TRIGGER (ANY DTC)”




                               Type DTC CODE
                               and press ENTER
     Hi-Scan Pro Application


1.3 CURRENT DATA – MANUAL TRIGGER (1/2)
 User triggers the record data.


                                MANUAL TRIGGER
                                  : Place a mark on a recorded data where “ENTER” button
                                  is pressed while recording.
                                  This mark is displayed as vertical line in “GRAPH” mode.
                                Next procedures are same as “AUTO TRIGGER”.
                                Select “DATA RECORD” type.


                                                 ENTER             ENTER

                                                         TYPE ID




                               ENTER
     Hi-Scan Pro Application


1.3 CURRENT DATA – MANUAL TRIGGER (2/2)
 Choose items to record: all or custom.

                                            ALL DATA RECORD
              “01” ENTER
                                                     : Record all sensor data
                                            ENTER : Place a mark on a data where
                                           “ ENTER” is pressed while
                                                       recording.




                                          USER SELECT DATA RECORD.
                                           : Record user defined sensor data.

                                           FIX : Select sensors to record and press
                                                  “F1”.
            “02” ENTER
                                           ENTER : Start “RECORDING”.

                                           ENTER : Start “TRIGGERING”.

                                           ESC :”STOP” recording.
    Hi-Scan Pro Application


1.3 CURRENT DATA –FLIGHT RECORD VIEW (1/2)
 Review recorded data




                                                 FLIGHT RECORD DATA REVIEW
                                                            : Review recorded data.
                                                 Select the memory location, then press
                                                “ENTER”.
                     ENTER                       Press “ENTER” to review recorded data.



                              Select the memory location
                              and press “ENTER”
     Hi-Scan Pro Application


1.3 CURRENT DATA –FLIGHT RECORD VIEW (2/2)
 Select review type.



                                        GRAP : Covert the “LIST” screen into “GRAPH”.
                                        LIST : Covert the “GRAPH” screen into “LIST”.
                                        HOME : Place the triggered position, displayed as
                                       vertical line, at the middle of the screen.
                                        FIX : You can scroll up and down without moving
                                       fixed item. If you press “FIX” again, you can change
                                       the item to fix.
          ENTER



                               F1 “GRAP”
                               F1 “LIST”
    Hi-Scan Pro Application


1.4 MONITORING RESULTS
 To monitor emission related operations
                                                                       Previous menu
                                                                                      ENTER

                                                                                              ENTER


                                                                                                  ENTER

                              Select “MONITORING TEST RESULT”
                                                                                                          ENTER
                              in “KIA VEHICLE DIAGNOSIS” mode.
                              In this case, connect with vehicle via
                              DLC cable.




                                                                         MONITORING TEST RESULT
                                                                         : This function provides 3 tests,
                                ENTER                                     which are
                                                                         1) READINESS TEST
                                                                         2) HO2S MONITERING TEST
                                                                         3) OBD2 MONITERING TEST
    Hi-Scan Pro Application


1.4 MONITORING RESULTS – READNESS TEST
 To monitor emission related operations




                                                 READINESS TEST : Displays vehicle’s on-
                                                  board monitoring.
                                                   : Emission-related operations are monitored.
                                                 Test result accurately reflect vehicles’
                                                  condition of emission related components.
                              ENTER




                                      ENTER
    Hi-Scan Pro Application


1.4 MONITORING RESULTS – HO2S MONITORING TEST
 To monitor Oxygen sensor test result.




                              ENTER           HO2S MONITERING TEST
                                               : display the results of the
                                               Heated Oxygen Sensor
                                               testing performed by the ECM
                                              Hi – Scan pro also displays
                                               test result by converting ECM
                                               data.
                                              The test result is valid only
                                               after ECM’s H2OS
                                               monitoring is finished.



                                         ENTER
                ENTER
    Hi-Scan Pro Application


1.4 MONITORING RESULTS – OBD2 MONITORING TEST
 To monitor OBD2 test.

                                           OBD2 MONITORING TEST
                                            : User can access to the on-board
                                            diagnostic monitoring test result of
                              ENTER
                                            specific component /system that are not
                                            continuously monitored.
                                           List of OBD monitor applicable for RIO
                                            - Three-way catalyst converter.
                                            - HO2S monitoring.
                                            - EVAP. EM monitoring.
                                            -Thermostat monitoring.
                                            - HO2S heater(B1S1).
                                            - HO2S heater(B1S2).
                                            - ECT Plausibility.




                                      ENTER
              ENTER
    Hi-Scan Pro Application
                                                                Previous menu
                                                                                ENTER
1.5 EVAP. LEAKAGE TEST (1/4)
                                                                                        ENTER
 To inspect EVAP leakage.
                                                                                                ENTER


                                                                                                    ENTER


                                                                                                        ENTER
                              Select “EVAP LEAKAGE TEST” in
                              “KAI VEHICLE DIAGNOSIS”
                              mode.
                              In this case, connect with vehicle via
                              DLC cable.

                                                                                  EVAP. LEAK TEST MODE
                                                                                  : The EVAP. Leakage Test is
                                                                                   based on the diagnosis
         F6 HELP                                 DOWN                              module for tank leakage
                                                                                   detection uses an electrically
                                                                                   driven vane pump.
                                                                                   Please follow the Hi-Scan
                                                                                   Pro EVAP. LEAKAGE
                                                                                   TEST process like picture.
    Hi-Scan Pro Application


1.5 EVAP. LEAKAGE TEST (2/4)
 To inspect EVAP leakage.




                              ENTER




                                         NORMAL CONDITION OF
                                          EVAP. SYS

                                          :If evap. Sys of vehicle had being
                                          normal, Hi-Scan Pro display O.K of
                                          the test results.
    Hi-Scan Pro Application


1.5 EVAP. LEAKAGE TEST (3/4)
 To inspect EVAP leakage.




                              ENTER



                                                 ABNORMAL CONDITION OF EVAP. SYS
                                                  :If evap. Sys of vehicle had being abnormal,
                                                  Hi-Scan Pro display ACTIVATION IS NOT
                                                  POSSIIBLE.
                                      ENTER      Please check the vehicle condition according
                                                  to Hi-Scan Pro process.


                                                  DOWN
    Hi-Scan Pro Application


1.5 EVAP. LEAKAGE TEST (4/4)
 To inspect EVAP leakage.




                              ENTER




                                         ABNORMAL CONDITION OF EVAP.
                                          SYS:If you retry EVAP. Leakage test
                                          with-in 5 minutes had finished EVAP.
                                          Leakage test, Hi-Scan Pro will display
                                          NOT NECESSRRY.
     Hi-Scan Pro Application


1.6 FLIGHT RECORD – AUTO TRIGGER (1/2)
 To record sensor or actuator data.
                                                                Previous menu
                                                                                    ENTER

                                                                                            ENTER

                                                                                                    ENTER
                                                                                                            ENTER




                                Select “FLIGHT RECORD” in “KIA                                                      ENTER

                                VEHICLE DIAGNOSIS” mode.
                                In this case, connect with vehicle with
                                DLC cable.



  AUTO TRIGGER                 ENTER       TYPE ID                                 ENTER : Select the memory
    (ANY DTC)
                                                                                    location then press “ENTER” to
                                                                                    type memory ID.
                                                                                   Type “CAR ID”.
                                                                                   ENTER : Go to “DATA
                                                                                    RECORD” select mode.
                                                                                    Select the “DATA RECORD” type
                                                                                    and press “ENTER”.
     Hi-Scan Pro Application


1.6 FLIGHT RECORD – AUTO TRIGGER (2/2)
 Choose items to record: all or custom.




                                           ALL DATA RECORD
                        “01” ENTER
                                            : Record all sensor data




                                          USER SELECT DATA RECORD.
                                           : Record user defined sensor data.


                                           FIX : Select sensors to record in ‘USER

                                                 SELECT DATA RECORD”.

                                           ENTER : Start “RECORDING”
                      “02” ENTER
                                           ESC :”STOP” recording
     Hi-Scan Pro Application


1.6 FLIGHT RECORD – AUTO TRIGGER (SINGLE DTC)
 Enter specific DTC which will be used as trigger.




                                                      AUTO TRIGGER(SINGLE DTC)
                                                        : Record user defined single DTC.
                                                      Type specific “DTC CODE”
                                                       and press “ENTER”.
                                                      Rest of procedures are same as
                      ENTER                            “AUTO TRIGGER (ANY DTC)”




                                 Type DTC CODE
                                 and press ENTER
     Hi-Scan Pro Application


1.6 FLIGHT RECORD – MANUAL TRIGGER (1/2)
 User triggers the record data.


                                MANUAL TRIGGER
                                  : Place a mark on a recorded data where
                                  “ENTER” button is pressed while recording.
                                  This mark is displayed as vertical line in “GRAPH” mode.
                                Next procedures are same as “AUTO TRIGGER”.
                                Select “DATA RECORD” type.




                                   Same procedure as
                                   “AUTO TRIGGER”
     Hi-Scan Pro Application


1.6 FLIGHT RECORD– MANUAL TRIGGER (2/2)
 Choose items to record: all or custom.

                                            ALL DATA RECORD
                                                     : Record all sensor data
                                            ENTER : Place a mark on a data where
                                           “ ENTER” is pressed while
       “01” ENTER
                                                       recording.




                                          USER SELECT DATA RECORD.
                                           : Record user defined sensor data.

                                           FIX : Select sensors to record and press
                                                  “F1”.
                                           ENTER : Start “RECORDING”.
     “02” ENTER
                                           ENTER : Start “TRIGGERING”.

                                           ESC :”STOP” recording.
    Hi-Scan Pro Application


1.6 FLIGHT RECORD –FLIGHT RECORD VIEW (1/2)
 Review recorded data.




                                                     FLIGHT RECORD DATA REVIEW
                                                     : Review recorded data.
                                                     Select the memory location,
                                                     then press “ENTER”.
                                                     Press “ENTER” to review recorded data.

                     ENTER


                              Select the memory location
                              and press “ENTER”
     Hi-Scan Pro Application


1.6 FLIGHT RECORD –FLIGHT RECORD VIEW (2/2)
 Select review type.

                                            GRAP : Covert the “LIST” screen into
                                           “GRAPH”.
                                            LIST : Covert the “GRAPH” screen into
                                           “LIST”.
                                            HOME : Place the triggered position,
                                           displayed as vertical line,       at the
                                           middle of the screen.
                                            FIX : You can scroll up and down without
                                           moving fixed item.
          ENTER                                    If you press “FIX” again, you can
                                           change the item to fix.



                               F1 “GRAP”
                               F1 “LIST”
    Hi-Scan Pro Application


1.7 DUAL DISPLAY                                                  Previous menu   ENTER
 Inspect the sensor or actuator data and DTC                                              ENTER
                                                                                                  ENTER


                                                                                                          ENTER




                                                                                                                  ENTER

                              Select “DUAL DISPLAY” in “KIA
                              VEHICLE DIAGNOSIS” mode.
                              In this case, connect with vehicle via
                              DLC cable.




                                                                             Hi-Scan Pro can display both
   F1 FIX                      F2 CURR                     F3 DTC             DTC and sensor data
                                                                              simultaneously.
                                                                             Use can check the sensor data
                                                                              which with DTC.
                                                                             FIX : Fix sensor data
                                                                             CURR : Activate current data
                                                                             DTC : Activate DTC data
    Hi-Scan Pro Application


1.8 SIMU-SCAN (1/4)
 Simulate and scan sensor or actuator simultaneously
                                                                 Previous menu    ENTER

                                                                                          ENTER

                                                                                                  ENTER
                                                                                                          ENTER




                              Select “SIMU-SCAM” in “KIA
                              VEHICLE DIAGNOSIS” mode.
                                                                                                                  ENTER
                              In this case, connect with vehicle via
                              DLC cable and test probe.




         F1 METER                             F2 SIML
                                                                          METER : voltage, frequency, duty,
                                                                           current, temperature and pressure
                                                                           meter

                                                                          SIMUL : voltage, frequency, duty,
                                                                           simulation
      Hi-Scan Pro Application


1.8 SIMU-SCAN (2/4)
  To measure the sensor data and compare with scan data




      F1 METER
                                                                 METER MODE
                                                                  : One of the most powerful feature of
                                                                   Hi-Scan Pro is SIMU-SCAN, in
                                PRESS “1” BUTTON ON KEY PAD
                                                                   which sensor output data is measured
                                                                   and current data is displayed
                                                                   simultaneously that user can compare
                                                                   actual data and ECM data.


                                                                 : This figure is an example of SIMU-
                                                                  SCAN screen for ECT sensor.
      Hi-Scan Pro Application


1.8 SIMU-SCAN (3/4)
  To measure the sensor data and compare with scan data


      F1 METER


                                PRESS “2” BUTTON
                                ON KEY PAD




                                                   PRESS “5” BUTTON
                                                    ON KEY PAD




                                                                           METER MODE
                                                                          : This is an example of
                                                                             SIMU-SCAN screen for
                                                                             ISC on time.
    Hi-Scan Pro Application


1.8 SIMU-SCAN (4/4)
 To measure the sensor data and compare with scan data




         F2 SIML
                                                   SIMU MODE
                                                   :This is an example of SIMU-
                              SELECT NUMBER “1”     SCAN screen for TPS sensor
                                 OF KEY PAD
                                                    with generated voltage 2V.
                                                   NOTICE
                                                   : SIMU MODE activate on
                                                    channel B only.
Hi-Scan Pro Application




  2. VEHICLE SCOPEMETER
       2.1 Part analysis
              - Engine : 17 items
              - Auto T/A : 9 items
       2.2 Manual scope
       2.3 Meter(V,F,R,A,T,P)
       2.4 Actuator driving
       2.5 Sensor simulator
      Hi-Scan Pro Application

2.1 PART ANALYSIS (1/2)
  Analyze part precisely in pre-set oscilloscope mode

                                Select “VEHICLE
                                SCOPEMETER” in “INITIAL
                                SCREEN” and select “KIA
                                VEHICLE AUTO SCOPE”.                  Provides easier component
                                Connect a test probe to “CH A”         inspection and more effective with
                                of Hi-Scan Pro and tap probe pin       pre-set DB support and reference
                                into appropriate signal wire of        waveform.
                                sensor or actuator.                   KIA VEHICLE AUTO SCOPE
                                                   ENTER               : Pre-set oscilloscope for KIA
                                                                       vehicles.
                                                                      MANUAL SCOPE : Oscilloscope
                                                                       mode.
                                                                      METER : Multi-meter mode.
                                                                      ACTUATOR DRIVING
                                                                       : Test drive “ACTUATOR”.
                                                                      SENSOR SIMULATOR
                                                                       : Send dummy data to inspect
                                                                       status of sensors.
      Hi-Scan Pro Application

2.1 PART ANALYSIS (2/2)
  Analyze part precisely in pre-set oscilloscope mode


                                ENTER




                                        ENTER




                                                ENTER




                                                           ENGINE : 17 items.
                                                           A/T : 9 items
      Hi-Scan Pro Application


2.1 PART ANALYSIS ---- ENGINE : SENSOR (1/2)
  Analyze part precisely in pre-set oscilloscope mode
                                                    PREVIOUS MENU
                                                               ENTER


                                                                       ENTER



                                                                               ENTER




                  ENTER

                                                             Engine sensor mode has
                                                              17 pre-set items.
                                                             User have to connect test
                                                              probe to “CH A”, and
                                                              prick probe pin to sensor
                                                              signal wire.
      Hi-Scan Pro Application


2.1 PART ANALYSIS ---- ENGINE : SENSOR (2/2)
  Analyze part precisely in pre-set oscilloscope mode
                                                        PREVIOUS MENU
                                ENTER                                ENTER


                                                                             ENTER



                                                                                     ENTER




                                  WAVE                    CKP SENSOR
      ENTER
                                                              TIPS : Sensor information.
                                                              WAVE : Reference waveform
                                                               of sensor.
                                                              AUTO SET DB SUPPORT
                                                             - Voltage, Time, Trigger Level.


                                   TIP
      Hi-Scan Pro Application


2.1 PART ANALYSIS ---- ENGINE : ACTUATORS
  Analyze part precisely in pre-set oscilloscope mode
                                                   PREVIOUS MENU
                                                                   ENTER
                                ENTER

                                                                           ENTER



                                                                                   ENTER




                                  WAVE                   INJECTOR
      ENTER                                                TIPS     : Actuator Information.
                                                           WAVE : Reference Waveform
                                                            of sensor.
                                                           AUTO SET DB SUPPORT –
                                                            Voltage, Time, Trigger Level.

                                   TIP
      Hi-Scan Pro Application


2.1 PART ANALYSIS ---- ENGINE : IGNITION
  Analyze part precisely in pre-set oscilloscope mode
                                                   PREVIOUS MENU
                                                               ENTER

                           ENTER
                                                                       ENTER



                                                                               ENTER




           ENTER                                           1’ST IGNATION WAVE
                                                           WAVE : Standard waveform
                                                            of sensor
                                   WAVE                    AUTO SET DB SUPPORT -
                                                            Voltage, Time, Trigger Level.
      Hi-Scan Pro Application


2.1 PART ANALYSIS ---- Automatic Transmission
  Analyze part precisely in pre-set oscilloscope mode


                                ENTER




         ENTER
                                                           Automatic Transaxle
                                                            mode has 9 pre-set items.
     Hi-Scan Pro Application


2.2 MANUAL SCOPE
 User defined oscilloscope.




                               Select “VEHICLE SCOPEMETER” in “INITIAL
                               SCREEN” and select “VEHICLE SCOPEMETER”.
                               Connect a test probe to “CH A” or “CH B” of Hi-
                               Scan Pro and tap into signal wire of sensor or
                               actuator.




                                          ENTER
     Hi-Scan Pro Application


2.2 MANUAL SCOPE (1/3)
 User defined oscilloscope.                        PREVIOUS MENU
                                                                   ENTER




                                  2 Channel digital scope
                                  Sampling speed : 1MHz / Sec
                      ENTER
                                  Time division   : 20㎲ ~ 50S
                                  Voltage division : 0.5V ~ 50V
                                  Adjustable GND level
                                  Waveform zoom function
                                   (1x, 2x, 5x)
                                  Cursor data display
     Hi-Scan Pro Application


2.2 MANUAL SCOPE (2/3)
 User defined oscilloscope.




                                                   PREVIOUS MENU
                                                                   ENTER




                      ENTER
                                   Selectable data “ON / OFF” by ◁,▷ KEY
                                   Selectable grid line /dot by ◁,▷KEY
                                   Selectable trigger mode by ◁,▷KEY
                                 - MODE : “Repeat”, “Single”, “Auto”
                                 - SOURCE : A↑A↓B↑B↓
                                 - LEVEL : 0 ~ 100%
                                 - DELAY : 0 ~ 100%
     Hi-Scan Pro Application


2.2 MANUAL SCOPE (3/3)
 User defined oscilloscope.




                                                       PREVIOUS MENU
                                                                       ENTER




                                  Larger record space - 128KB continuous sampling
                                  Video replay view
                                  Trend view function
                                   (AVERAGE, MIN-MAX,FREQUENCY, DUTY)
                                  Cursor data display
                                  Waveform zoom function
                                    (1x, 2x, 5x)
    Hi-Scan Pro Application

                                            PREVIOUS MENU
2.2 MANUAL SCOPE – HOLD (1/7)
 How to use “HOLD” function.                                  ENTER




                              HOLD



                                               HOLD : Screen hold.
                                                Function key will be changed
                                                after “HOLD” button is pressed.
                                               ZOOM : Zoom “IN” or “OUT”
                                                screen. - X1, X2, X5.
                                               CURSOR : Display numerical
                                                value of waveform.
                                               RECORD : Record waveform.


                ZOOM                 CURS               RECD
    Hi-Scan Pro Application


2.2 MANUAL SCOPE – HOLD (2/7) : ZOOM
 How to use “ZOOM” function.

                                                      PREVIOUS MENU
                                                                     ENTER


                                                                              ENTER




                  ZOOM

                                  ZOOM
                                  User can zoom “IN” or “OUT” by pressing
                                   “▲” or “▼” button respectively.
                                  User can scroll “LEFT” to “RIGHT” by
                                   pressing “◀” or “▶” button respectively.
    Hi-Scan Pro Application


2.2 MANUAL SCOPE – HOLD (3/7) : CURSOR
 How to use “CURSUR” function.
                                                     PREVIOUS MENU
                                                                       ENTER

                                                                                  ENTER




                                 CURSOR
                    CURS         Cursor is used to display numerical value of waveform.
                                 Press “CURS” to display two “CURSORS”.
                                  Move left cursor-straight lined- by pressing “◀” or “
                                  ▶” button.
                                 Press “CURS” button again to activate Right cursor-
                                  dashed line.
                                  Cursor will be converted from “dash” to “straight”.
                                 Press “CURS” button once again, to move both cursors
                                  together.
                                 All the values will be displayed at the top of the screen.
    Hi-Scan Pro Application


2.2 MANUAL SCOPE – HOLD (4/7) : RECORD
 How to use record function.
                                                     PREVIOUS MENU
                                                                        ENTER

                                                                                ENTER




                    RECD
                                  RECORD : Records for 1 second
                                  FLIGHT RECORD REVIEW
                                   : Review previously recorded data.

                                  NEW FLIGHT RECORD
                                   : Record new data-New data; overwrite on
                                     previous record.
     Hi-Scan Pro Application


2.2 MANUAL SCOPE – HOLD (5/7) : FLIGHT RECORD VIEW(1/2)
  How to view “FLIGHT RECORD”.
                                                                PREVIOUS MENU
                                                                                 ENTER




                                  HOLD : Screen hold.
                                  PLAY : Play recorded data.
                                  ZOOM : Zoom IN or OUT screen.
                                  CURS : Display numerical value of waveform.
                                  VIEW : AVERAGE & MIN-MAX TREND
                                          FREQUENCY & DUTY TREND
                                          FLIGHT RECORDED WAVEFORM
                 ENTER            EXIT : Return to “HOLD” mode.



                               HOLD
     Hi-Scan Pro Application


2.2 MANUAL SCOPE – HOLD (6/7) : FLIGHT RECORD VIEW(2/2)
  How to view “FLIGHT RECORD”.



                               VIEW      AVERAGE & MIN-MAN TREND
                                          : Display average, minimum, and maximum
                                            value of waveform.
                                         FREQUENCY & DUTY TREND
                                          : Display frequency and duty of waveform.
                                         FLIGHT RECORDED WAVEFORM
                                          : Return to “HOLD” mode.
                                         Scroll left or right by “◀” or “▶” respectively and the
                                          cursor data is displayed in the box at the left.

                                                                            FLIGHT RECORDED
    AVERAGE & MIN-MAX                     FREQUENCY & DUTY
                                                                                WAVEFORM
         TREND                                 TREND
    Hi-Scan Pro Application


2.2 MANUAL SCOPE – HOLD (7/7) : NEW FLIGHT RECORD
 How to record a “FLIGHT RECORD”.




                                               NEW FLIGHT RECORD
                                                : Overwrite new data on previous data.
                                               Press any button to start recording.
                    RECD                       Replay start after recording is finished.




                              HIT ANY KEY
    Hi-Scan Pro Application


2.2 MANUAL SCOPE – MENU : DATA
 What is “DATA” function.                                          PREVIOUS MENU
                                                                                     ENTER




          ON
                                 DATA
                                 ON : Following data will be displayed at the top of the screen.
          OFF                     1) MIN : Minimum Voltage.
                                  2) AVE : Average Voltage.
                                  3) MAX : Maximum Voltage.
                                  4) FREQ : Frequency of Waveform.
                                  5) DUTY : Duty cycle of Waveform.
                                 OFF : “DATA” will disappear.
                                 NOTE : If the “TIME” is set as “20us”, “DATA” function will
                                  not be supported and only one channel is available-“Ch A” or
                                  “Ch B” due to fast sampling load.
    Hi-Scan Pro Application


2.2 MANUAL SCOPE – MENU : GRID
 What is “GRID”.
                                                     PREVIOUS MENU
                                                                  ENTER




                                 GRID
                                 User can change the “GRID” from “DOT” or “LINE” to
                                  “LINE” or “DOT” respectively.




                                  DOT

                                  LINE
    Hi-Scan Pro Application


2.2 MANUAL SCOPE – MENU : TRIGGER (1/2)
 What is “TRIGGER” type.


                                                          PREVIOUS MENU
                                                                        ENTER




                                 MODE
                                 AUTO : Display all the waveform regardless of trigger level.
                                 REPEAT : Screen is refreshed whenever waveform is above the
                                  trigger level.
                                 SINGLE : If waveform is above the trigger level, the screen
                                  will be fixed with triggered waveform.
    Hi-Scan Pro Application


2.2 MANUAL SCOPE – MENU : TRIGGER (2/2)
 How to set and use “TRIGGER”.


                                                    PREVIOUS MENU
                                                                  ENTER




                                    SOURCE
                                    A↑, B↑
                                 : “Rising edge” of waveform will be displayed at the
                                     delay level.
                                    A↓, B↓
                                 : “Falling edge” of waveform will be displayed at the
                                     delay level.
                                    LEVEL : Waveform will be displayed if it is above
                                     this “Trigger level”.
                                    DELAY : Horizontal position of “Triggered place”.
      Hi-Scan Pro Application


2.3 MULTI METER
 What is “MULTIMETER”.
                                    Enter after select “3. Meter”
 Connect a test probe from “CH A”                                   PREVIOUS MENU
 or “CH B”, or both channel and
                                                                              ENTER
 to desired Actuator or Sensor.




                                              2 channel multi meter
                                              Volt meter : max 500VDC
                                              Frequency meter : 0 ~ 100KHz
                                              Duty meter : 0 ~ 100%
                                              Ohm meter : 0 ~ 10㏁
                                              Automatic unit conversion (CURRENT METER /
                                               TEMPERATUE / PRESSUR METER)
      Hi-Scan Pro Application


2.4 ACTUATOR DRIVING
 How to drive an actuator.       Enter after select “4. Actuator”

                                                                    PREVIOUS MENU
                                                                               ENTER
 Connect a test probe from “CH
 A” and to desired Actuator.




                                             Actuator Driving Mode enables to operate
                                              actuator forcibly driven by Hi-Scan pro
                                             Actuator driving is operated only on “CH A”.
                                             Warning) Do not use this mode when Engine Is
                                              running
                                             DRIV => Start Driving
                                             STOP => Stop Driving
                                             ◁ ▷ => Select the Items
                                             △▽ => Chang the Selected Items Level
        Hi-Scan Pro Application


2.5 SENSOR SIMULATOR
   How to simulate a sensor.
                                      Enter after select “5. Sensor simulator”

                                                                                 PREVIOUS MENU
                                                                                           ENTER
Connect a test probe to “CH B”
and to desired Sensor.




                                       Sensor simulation is operated only on “CH B”
                                       User can simulate a sensor in this mode.
                                       VOLT-Simulate a sensor with specific “VOLTAGE”
                                       FREQ-Simulate a sensor with specific “FREQUENCY”
                                        In “FREQ” mode, user can switch from the ‘Frequency’
                                        to ‘Duty’ and vice versa by pressing “SLCT” button.
                                        In “FREQ” mode, user can change the value of
                                        ‘Frequency’ and ‘Duty’ using “+” and “-” button.
    Hi-Scan Pro Application


3. SYSTEM SETUP
 Setup system.




                              ENTER




                                 ENTER      Hold Last Screen => Determines whether the last screen
                                             in vehicle diagnosis or oscilloscope mode is saved before
                                             power shut down
                                            Language =>Determine whether to use “Beep” sound
                                             when the buttons are pressed.
                                            Language => Determines whether local language is used
                                            Unit Conversion => Selects the measuring units of Hi-
                                             Scan pro.
                                            Self Test => Determines whether self test is performed at
                                             each power up
Hi-Scan Pro Application




4. OPTIONAL ITEMS


  4.1 Current pick up(1A ~ 600A)

  4.2 Current pick up(50mA ~ 100A)
CURRENT PICK UP (1~600A)




               Compression pressure test
               Cold cranking ampere test
               Etc
CURRENT PICK UP (1~600A)(1/2)                                      PREVIOUS MENU
                                                                                   ENTER
  To perform compression pressure test.




                                   Connect high current measuring device to CH A or B
                                   Set to “10mV/A” in current level selecting switch.
                                   Perform zero adjustment.
                                   Set as 50ms for time-division and 5V for voltage-
                                    division.
CURRENT PICK UP (1~600A)(2/2)
 To perform compression pressure test.




                                                       Clamp the “+” or “-” terminal of battery
                                                        with current measuring device.
                                                       Remove ECU fuse.
                                                       Start cranking for about 2 seconds.
                                                       Abnormal and normal waveforms are
                                                        shown respectively at the bottom.




          When 1st cylinder spark plug is removed
CURRENT PICK UP (1~600A)(1/2)                                     PREVIOUS MENU
                                                                                   ENTER
 To perform cold cranking ampere test.




                                  Connect high current measuring device to CH A or B
                                  Set to “1mV/A” in current level selecting switch.
                                  Perform zero adjustment.
                                  Set as 50ms for time-division and 0.2V for voltage-
                                   division.
CURRENT PICK UP (1~600A)(2/2)
 To perform cold cranking ampere test.

                                        Clamp the “+” or “-” terminal of battery with
                                         current measuring device.
                                        Remove ECU fuse.
                                        Start cranking for about 2 seconds.
                                        Example waveform is shown at the bottom right.
                                        When testing cranking current, read MAX value
                                         for current value as shown in bottom right fig.
                                          Example) Regard MAX : 335,2mV as 335,2A
                                         for cranking current.
                                        Compare with standard value, if it is above 70%
                                         then it is in normal condition.
CURRENT PICK UP (50mA~100A)




               Primary ignition current test
               Actuators current test
               Etc
CURRENT PICK UP (50mA~100A)(1/2)                                    PREVIOUS MENU
 To perform primary ignition current test.                                            ENTER




                                      Connect low current measuring device to CH A or B
                                      Set to proper level in current level selecting switch.
                                      Perform zero adjustment.
                                      Set time-division and voltage-division.
CURRENT PICK UP (50mA~100A)(2/2)
 To perform primary ignition current test.




                                                Clamp the primary ignition signal wire
                                                 with low current measuring device.
CURRENT PICK UP (50mA~100A)                                           PREVIOUS MENU
                                                                                        ENTER
 To perform actuators current test.




                                         Connect low current measuring device to CH A or B
                                         Set to proper level in current level selecting switch.
                                         Perform zero adjustment.
                                         Set time-division and voltage-division in Hi-Scan pro.
                                         Clamp any actuator you wish to measure with low
                                          current measuring device.
CURRENT PICK UP (50mA~100A)(1/2)
                                                                PREVIOUS MENU
 To measure parasitic current.
                                                                               ENTER




                                    Connect low current measuring device to CH A or B
                                    In ‘METER’ screen, select channel and current level
                                     and press ‘Enter’.
                                    Select current level as assigned in Hi-Scan Pro.
CURRENT PICK UP (50mA~100A)(2/2)
 To measure parasitic current.



                                    Perform zero adjustment.
                                    The parasitic current of wire, which is connected
                                     from battery to 60A fuse in fuse box, is measured in
                                     Hyundai Accent as shown at the bottom right
                                     figure.
                     5. PC-SCAN
1) Install PC-Scan
2) SCAN TEST

3) FLIGHT RECORD

4) SCOPE

5) SERVICE INFORMATION

6) SCREEN CAPTURE

7) S/W DOWNLOAD

8) OPTION
      1) Installation of PC-SCAN program - 1
   Insert the CD and click “Setup” file, and then follow instruction as
    shown in figure 1~5 step by step.


                                 CLICK THE “OK” BUTTON




DOUBLE CLICK THE SETUP
        ICON
Installation of PC-SCAN program - 2
    CLICK INSTALL BUTTON




                   CHOOSE INSTALL DIRECTORY




                           PROGRAM INSTALLING




                                                PROGRAM INSTALL DONE
2) SCAN TEST - 1
        This function is to provide all of the
        scanning tests on your PC. If you press
        'SCAN TEST' button on the menu, the
        following "Vehicle Diagnosis" screen will
        be displayed for your vehicle/system
        selection to test firstly.
        Select the vehicle/system to test in order as
        follows.
         (1) Select proper vehicle model to test on
             the upper-left column.
         (2) Select proper system name to test on
             the upper-right column
         (3) Select proper system type on the
             lower-left column.
     SCAN TEST- 2
(DIAGNOSTICS TROUBLE CODES)
            If you press [DIAGNOSTIC TROUBLE
             CODES] button on the picture’s Sub Menu
             screen, the following screen will be displayed
             for DTC testing.
             ERASE : Provides to erase the memorized
                             DTC after repairing the
                             troubles clearly.
            TIP          : Provides relevant service or
                             repair guides
            PRINT        : Provides to print current
                            screen out.
            HELP        : Provides relevant user's
                            operation guides on the
                            current screen.
            PREVIOUS : Provides to return to the
                               previous menu screen
SCAN TEST - 3
 (CURRENT DATA)
       This function is to provide on-line current data analysis
      of each sensor transferred through the ECU.
        If you press [CURRENT DATA] button on the picture’s
      Sub Menu, the following screen will be displayed for
      Current Data Analysis.
      Select sensor names(maximum 8 items at once) on the
      sensor item column by clicking the items. To cancel its
      selection, click it again of the selected item.
     TEXT : Provides on-line numeric values on the selected
               sensors as picture.
     PRINT : Provides to print current screen out.
     TIPS : Provides diagnostic information for service data
               which selected finally.
     PREVIOUS : Provides to return to the previous menu
                       screen.
     GRAPH : Provides to analyze on-line current data
                  values in a graphic waveform as below.
SCAN TEST - 4
 (CURRENT DATA)
      RECORD : Provides to record current graphic data in a
                   temporary buffer memory on PC.
      MARKING : Provides to indicate location mark during
                     data recording.
      STOP : Provides to stop recording
      REC DATA VIEW : Provides to recall a waveform data
                from the recorded temporary memory on PC.
      SAVE : Provides to save any waveform data in a file form
               from the temporary memory data.
      PRINT : Provides to print out current screen.
      HELP : Provides relevant user's operation guides on the
               current screen.
      PREVIOUS : Provides to return to the previous Current
                     Data Main menu screen.
      ZOOM BAR : Provides to magnify current screen by using
                     the arrow buttons up to 10 times.
SCAN TEST- 5
(ACTUATION TEST)

       This function mode enables to operate certain actuators
       through communication between ECM and Hi-Scan Pro.
       So, If the ECM does not provide this function, you can not
       use this actuation test mode.

       Select any actuator item to test on the left column and click it on.
       The test must be performed as per the conditions indicated on
       the screen. To cancel the selection, click it on again.

      START : Provides to start its testing.
      PRINT : Provides to print current screen out.
      HELP : Provides relevant user's operation guides on the
                current screen.
      PREVIOUS : Provides to return to the previous function
                   menu screen.
3) FLIGHT RECORD
       This function is to provide downloading a data to your PC from
        the recorded memory of the Hi-Scan Pro, or recalling a data from
        the                         PC                          memory.

       LIBRARY : Provides to recall and refer pre-memorized
                    standard sample data or waveform.
       OPEN : Provides to open a recorded flight data file from PC
                memory.
       SAVE : Provides to save a flight record data in a file form.
       LOAD : Provides to download a flight record data from Hi-
                Scan Pro into your PC.
       INFORMATION : Provides to add user's information on the
                            current data screen.
       PRINT : Provides to print current screen out.
       HELP : Provides relevant user's operation guides on the
                current screen.
       PREVIOUS : Provides to return to the main menu screen.
4) SCOPE
     This function is to provide downloading a scope data either
      from your PC or Hi-Scan Pro memory.

     LIBRARY : Provides to recall pre-memorized standard
                   sample scope waveforms.
     OPEN : Provides to open a recorded scope waveform file
              from your PC memory.
     SAVE : Provides to save a scope waveform in a file form
              to your PC.
     LOAD : Provides to download a scope waveform from
              Hi-Scan Pro into your PC.
     INFORMATION : Provides to add user's information on
                           the current data screen.
     NOTE : Provides to add a personal information label on
               the current data screen for detailed explanation.
     PRINT : Provides to print out current screen.
     HELP : Provides relevant user's operation guides on
                 the current screen.
     PREVIOUS : Provides to return to the main menu
                    screen.
5) SERVICE INFORMATION

              This mode provides all of the relevant service and repair
               information for each vehicle and system in CD-ROM.

              BACK : Provides to return to the previous screen.
              FORWARD : Provides to go to the next screen.
              E-MAIL : Provides to send an E-Mail message to the
                         supplier.
              PRINT : Provides to print out the current screen.
              MAIN : Provides to return to the main menu screen.

              Exploring methods and procedures are same as those of
               general Internet Web-browser.

             * Note : Be sure to insert relevant CD-ROM into your
                      PC driver before using this mode.
6) SCREEN CAPTUTE
         This function is to provide either downloading or saving current
          screen onto your PC.
         LIBRARY : Recall pre-memorized standard sample data.
         OPEN : Open a saved screen capture data file from your PC hard
          disk.
         SAVE : Save the captured screen in a file form.
         LOAD : Download current Hi-scan Pro screen onto your PC.
         INFORMATION : Add user's information on the current data.
         NOTE : Add notes about current data screen for personal record.
         PRINT : Print out current screen.
         HELP         : Provides relevant user's operation guides on the
          current screen.
         PREVIOUS : Return to main menu screen.
         TITLE : Input title of captured screen.
         MADE BY : Input user's name on the captured screen.
         FILENAME : Not accessible by users. It's for program designer's
          purpose.
           * Use [SAVE] button to input its file name.
         COMMENT : Add personal comments.
          7) S/W DOWNLOAD - 1
 Get connected
       : Connect your PC and Hi-Scan Pro with RS-232C cable




               COM1
                        RS232C Cable
                        (Standard Item)
                 S/W DOWNLOAD - 2
 After connect RS-232C cable, go to “OPTION” in Pc-scan main
   screen and assign com port 1 or 2.
                                               SELECT COMMPORT 1 OR 2




       CLICK “ OPTION” BUTTON                         CLICK “OK” BUTTON




        Please move “cardall.dat” file into “PcScan.CAB”
                 S/W DOWNLOAD - 3
   Select S/W Download in your PC-Scan Program initial screen as
    shown in below figures.
   Select “cardall.dat” file at DB folder which is in PcScan.CAB file.




                                                     SELECT CARDALL.DAT

           NOTICE
             * Assign the file(cardall.dat) path
             * Select 56000 for Baud Rate
             * Select “Standard Pack” for Data Type
                              8) OPTION




   This function is to set-up communication speed and CD-ROM directory for Service
    Information function.
   BAUD RATE : Select communication speed between your PC and Hi-Scan Pro from
          9,600 up to 56,000 bps.
   SERVICE INFORMATION FOLDER (Main.html) : Select the location of
                                                        Main.html file.
   HELP : Provides relevant user's operation guides on the current screen.
   OK : Confirm selection.
   CANCEL : Cancel selection and return to the main menu screen.

				