Docstoc

Accessories

Document Sample
Accessories Powered By Docstoc
					Innovations 2006

HMI innovations




                  MTS May 2006



                                 ‹Nr.›
Innovations 2006

SBU 1 Industrial enclosures




                 MTS May 2006



                                ‹Nr.›
Accessories

P. 8
Two-handed operating consoles
• Maximum safety categories are met
• Two safety buttons for each hand
• Thus, hands are on the safety button at all times
• No additional cover is required




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   3
Plastic enclosures KS

• P. 15
• Colour changed to RAL 7035
• The colour of accessories has also changed




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   4
CM accessories

P. 18
• CM gland plates
   • Optimised dimensions
   • "Old" dimensions did not have the "best
       fit“




• CM and TS cable entry plate
   • "Only buy what you really need"
   • Packs of 1


   Thema oder Anlass des Vortrags      Autor / Abteilung / Datum   5
CM accessories

P. 21
• CM folding lever handle
   • Prepared for padlocks
   • For KESO / KABA
   • For ASSA

• CM mounting plate slide block
   • Similar function as the one for TS8
   • May be reused several times "as a tool"

• CM door stay
   • Installation without drilling
   • Spring-mounted
   • Simply snap into position / snap out

   Thema oder Anlass des Vortrags    Autor / Abteilung / Datum   6
CM accessories

P. 23
• CM rain canopy / vented roof plate
   • Reliable protection for outdoor siting
   • Water runs off to the rear
   • Mounting via the existing holes
       (eyebolts)
   •   At the front, with integrated ventilation
       holes at the top
   •   May also be used when the enclosure is
       twisted
   •   Ventilation holes




   Thema oder Anlass des Vortrags      Autor / Abteilung / Datum   7
CM accessories

P. 23
• CM divider kits
   • For swing frame, large
   • With and without trim panel
   • For enclosure width mm: 600 and 800
       mm
   •   For swing frame, large with trim panel,
       the 180° hinge may be used




   Thema oder Anlass des Vortrags      Autor / Abteilung / Datum   8
Comfort Panel

P. 24-34
• New panel / installation depth 113 mm

• Off the shelf:
    • Operating housing 19" x 7 U x 113 mm
    • Keyboard housing 19“ x 3.5 U x 113 mm
    • Keyboard housing 19“ x 4 U x 113 mm



• Accessories
    • USB extension
    • Protection category IP 66 / 67

   Thema oder Anlass des Vortrags      Autor / Abteilung / Datum   9
Quickline panel
P. 37
• Cut-out for commercially available
   Siemens panels
• Cost-efficient solution
• In order to open the door, release the
   hinge pins
• Interior installation with mounting
   bracket CP 6205.100




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   10
Accessories
P. 39
• Pedestal, height-adjustable
   • Swivel area max. 180°
   • Adjustment range 200 mm
   • With integral gas pressurised spring for pressure
       relief during height adjustment
   •   Assembly:                                                  Surfaces

         • Rear: attachment using cage nuts
         • Front: via mounting bracket (accessories).


                                                                  Niches




           Compact Panel            TFT holder
   Thema oder Anlass des Vortrags     Autor / Abteilung / Datum              11
Accessories

P. 40
Support arm, height adjustable, compact
• For panels and TFTs with 2.5 – 8.5 kg
   • with VESA 75 cut-out at the top
   • Bottom desk clamp for worktops (up to 75 mm
       thick)


• Adjustment options:
   • bottom, swivel and tilting
   • top, vertically hinged and tilting

• Adaptor for VESA 100 as accessory


   Thema oder Anlass des Vortrags         Autor / Abteilung / Datum   12
Accessories

P. 46
Housing coupling
• Command panels from an installation
   depth of 150 mm and IW worktops

• Variant for support arm / pedestal

• 350° rotation range may be locked via
   clamping levers




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   13
Industrial workstations

P. 49
IW logistic point
• Complete solution
   for accommodating:
   •   PC
   •   Printer
   •   Monitor
   •   Supply includes:




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   14
Industrial workstations

P. 49
IW logistic point printer cabinet 600 x 900 x 600 mm
• For accommodating
    • Commercially available printers and desktop PCs
• Designer door prepared for mounting installation
   modules
• Component shelf, pull-out

P. 49
Paper removal flap
    • Easy access through integral glazed door
    • Installation module with custom-made cut-out as
       special order, e.g. for label printers

   Thema oder Anlass des Vortrags        Autor / Abteilung / Datum   15
Industrial workstations

P. 54
IW stainless steel operating station
• For use in
    • Food industry
    • Pharmacy
    • Petro-chemistry

P. 55
• Stainless steel enclosure for tower PC
    • W x H x D: 760 x 760 x 300 mm
    • Roof with cut-out for:
         • CP-S support arm
         • Keyboard cable
         • Worktop


   Thema oder Anlass des Vortrags      Autor / Abteilung / Datum   16
Accessories

P. 55
• Worktop, stainless steel
• WHD: 900 x 38 x 600 mm
• Laminated on both sides with cut-out for CP-S
   support arm
• Prepared for stainless steel keyboard or solid


P. 55
• Cross member, stainless steel
• To increase stability, the cross member protrudes
   120 mm above and behind


   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   17
FP housings / enclosures

Available from 2007 on!!!
The regulations are being changed!!!
FP = Fire Protected
Fire-protected housings and enclosures
• Secure escape and rescue paths
• Maintaining the function of:
    • Elevators
    • Emergency power supply
    • Extinguishing water
• E.g. public institutions, airports, hospitals,
   schools, museums, libraries...



    Thema oder Anlass des Vortrags    Autor / Abteilung / Datum   18
FP housings / enclosures
P. 56
All dimensions without lining!!!
• FP-TS8 (W x H x D):
    • 800 x 2000 x 600 mm
    • 800 x 2000 x 500 mm
    • 800 x 1800 x 400 mm

• FP-CM (W x H x D):
    • 800 x 1000 x 300 mm
    • 800 x 1200 x 400 mm

• FP-AE (W x H x D):
    • 600 x 600 x 210 mm
• Other sizes available on request!

    Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   19
FP housings / enclosures
 P. 56
 FP-PL terminal box with function retention
 • Function retention: E 30/ E 60/ E 90
 • Protection category: IP 54
 • 100 x 100 x 50 mm and
 • 115 x 115 x 66 mm

 FP – KL
 • Function retention: E 30
 • Protection category: IP 66
 • 115 x 115 x 93 mm with and without fused
   junction


  Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   20
Stainless steel keyboard housing

P. 51
• 4 dimensions for 1 to 4 command and
   signalling units 22.5 mm




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   21
AE enclosure

P. 52
Four new dimensions for:
   • AE stainless steel
   • Stainless steel 1.4301 (V2A)

Stainless steel 1.4404 (V2A)
   • Now 5 dimensions available off the shelf
   Accessories:
   • Cam lock changed for 1.4404
   • New wall bracket in stainless steel




   Thema oder Anlass des Vortrags    Autor / Abteilung / Datum   22
AE enclosure

P. 53
AE IP 69K stainless steel

• Same dimensions as stainless steel

• 10° roof tilt prevents liquids from
   accumulating on the roof

• Silicone seal
    • Temperature-resistant: -60°C to +180°C




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   23
Stainless steel enclosures

Silicone seal for stainless steel enclosures

• Protects better against aggressive cleaning
   agents and disinfectants

• Seal absorbs almost no water

• Temperature-resistance: -60°C to +180°C

• Also available as special for:
    • AE stainless steel, single-door
    • BG stainless steel
    • KL stainless steel


   Thema oder Anlass des Vortrags       Autor / Abteilung / Datum   24
TS 8

Also available in WxHxD:
• 600 x 1200 x 500 mm
• 800 x 1200 x 500 mm
• 1200 x 1200 x 500 mm
• Suitable side panels as accessories

TS 8 stainless steel: brushed finish changed
  from 240 to 400 grain:
    •   Enclosures
    •   Side panels
    •   Base/plinth components, front and rear
    •   Baying cover, top


   Thema oder Anlass des Vortrags      Autor / Abteilung / Datum   25
Accessories

P. 178
Pressure relief valve
• Protection category IP 66, 68, 69K
• Reduces the formation of condensation


P. 178
Universal key
• With bit adaptor and turning bit:
• Torx 25
• Recessed head (Ph 2)


   Thema oder Anlass des Vortrags     Autor / Abteilung / Datum   26
Accessories

P. 183
• Support rail 65 x 42 mm, unslotted for
    enclosure width /depth 400, 500, 600 and
    800 mm

P. 183
• Support rail for heavy-duty components (up
    to 5,000 N / rail)
• Suitable for 600 and 800 mm wide
    enclosures

P. 182
• Attachment for TS punched section with
    mounting flange, 17 x 73 mm
    • when the screw-joint cannot be accessed


    Thema oder Anlass des Vortrags     Autor / Abteilung / Datum   27
Accessories

P. 50
• TS 180° for dynamic loads
   • Heavy, dynamic loads
   • Heavy equipment installed on the door
       (up to 900 N)


P. 180
• Protective beam and holder
   • Alternative to a door in a switch room
   • Prevents objects from falling into the open
       enclosure frame




   Thema oder Anlass des Vortrags    Autor / Abteilung / Datum   28
Accessories

P. 179
• Sealing frame for through-panel
   mounting in rear or side panels

   • To suit enclosure widths of 600 mm and
       above
   •   In depths of 75 and 100 mm
   •   Mounting plate in a set forward position
   •   Protection category IP 54 subject to
       correct mounting




   Thema oder Anlass des Vortrags      Autor / Abteilung / Datum   29
Accessories

P. 181
Wiring plan pocket
• Sheet steel for TS, CM, ES, PC
• Depth 35 mm

• Plastic, self-adhesive
• Knockouts for optional screw joints




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   30
Accessories

P. 190
Cable conduit
• Two sizes: SW 29 / 50
   • Connected straight or in a 90° angle
   • Holder for correct laying




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   31
Accessories

P. 195
Compact light
• Multifunctional fastening on both sides
    • Magnet, clip, screws or combinations thereof
    • May be positioned flexibly

• Saves power whilst producing more light
    • 8 watts compare with 14 watts standard/courtesy lights
    • 18 watts brighter than 14 watts standard/courtesy lights

• Integral connection cable, 3 m

• Pluggable door-operated switch as accessory


  Thema oder Anlass des Vortrags         Autor / Abteilung / Datum   32
Accessories

P. 186
Socket strip
• With three sockets, overvoltage protection
   and interference filter

• Socket inserts twisted by 45°

• Connection socket for front power supply




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   33
Accessories

Flyer
Connector gland
• Sealing frame for connector cut-
   outs 16/24-pole for 8/10 cables
• No dismantling required when
   individual cables/leads must be
   installed/dismantled
• Seals are fastened safely to the
   cable
• Incl. strain relief




   Thema oder Anlass des Vortrags    Autor / Abteilung / Datum   34
Innovations 2006

SBU 4 Power distribution




                 MTS May 2006



                                ‹Nr.›
RiLine60

• 60 mm busbar system

• Flat bar system with integral cross section
   adaptation: Now also available with base
   tray technology

• Top-mounting PLS systems: easier to
   assemble

• Connection adaptor with impressive
   connection system and a great number of
   versions


   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   36
RiLine60

• Type-tested to EN60439-1

• NEW: GL-approved

• System includes: approx. 130 articles

• Universal CB adaptor up to 630 A

• Innovative component adaptor system
  with support frame connector

• Protection category IP2x

   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   37
RiLine60

• Support frame with push-in trim
   • Important accessory for replacement
       assemblies for RiLine60 Premium
       adaptors
   •   Incl. support rail and push-in trim


• New adaptor versions
   • OM adaptor, 45 mm wide, with AWG10
   • OM adaptor, 75mm wide, with AWG6

• Connection angle for CB adaptors
   • Designed to suit 250 A CB adaptors
   • Designed to suit 630 A CB adaptors

   Thema oder Anlass des Vortrags       Autor / Abteilung / Datum   38
RiLine60 UL design

• New busbar holder with greater creepage distances
  and clearance
   • Base tray is a must-have
   • Short circuit data are similar to the IEC design

• Top-mounting components are identical with the IEC
  line
   •     OM / OT adaptors with AWG leads only
   •     CB adaptor 160 A in specific design
   •     New connection adaptor for PLS
   •     Rated data differ sometimes from IEC


• To be approved by June 2006

   Thema oder Anlass des Vortrags     Autor / Abteilung / Datum   39
RiLine60

• RiLine NH – the new generation of isolators
• Consistent design of all sizes
    from NH00 to NH3
•   With tried-and-trusted clamping screw
    technique
•   Simple reversal of the cable outlet at the
    top or bottom by rotating the mounting hooks
•   Perfectly integrated into the RiLine60 contact         Size     Width (before)   Height
    hazard concept: IP 2X
                                                           NH00     106 mm (115)     194mm
•   Safe operation, thanks to contact hazard
    protection                                             NH1      184mm (186)      298mm
•   Lid may be locked
                                                           NH2      210 mm (210)     298 mm
• Available from: 11/06 (NH00+1) and 01/07
    (NH2+3)                                                NH3      250 mm (250)     298 mm


    Thema oder Anlass des Vortrags      Autor / Abteilung / Datum                     40
Maxi PLS

• Corner connector for Maxi-PLS
   • For 90° connection for busbar systems in
       the roof area
   •   Available for 1600A / 2000A / 3200A
   •   Packaging: Packs of 1 set


• Corner bracket for Maxi-PLS
   • For 90° connection for busbar systems in
       the rear area
   •   Versatile
   •   Available for 1600A / 2000A / 3200A
   •   Packaging: Packs of 1 set for each busbar



   Thema oder Anlass des Vortrags    Autor / Abteilung / Datum   41
Maxi PLS

Maxi PLS–vertical coupling sets 1600 A
• Vertical coupling sets for Maxi-PLS 1600 A for
  busbar systems in the roof and rear area

• Rittal Maxi-PLS compact infeed
   • Flexible cable connection bar system,
     whatever the enclosure width
   • Several adjacent infeeds in one enclosure
   • Direct mounting on the punched section
     without mounting flange or on the mounting
     plate
   • For Maxi-PLS 1600 A / 2000 A busbars



   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   42
ISV

• Roof plate for cable entry gland
    • Roof plate with gland apertures
    • In exchange for the standard TS8 roof plate
    • Suitable for enclosures with
       Widths:        600, 850 and 1100 mm
       Depths:        400 and 600mm


• Solid cable entry gland.
    • For concealing unused openings
    • Inexpensive alternative to the existing gland plates




   Thema oder Anlass des Vortrags       Autor / Abteilung / Datum   43
Power Engineering V2.0

• New (compared to V1.0)
   •   Corner field
   •   2200 mm high enclosures
   •   Parts lists can be exported directly into Excel
   •   Automatic text configuration for special
       connection kits
   •   Flexible user tool "My Accessories"

• Optimised
   • PE and neutral conductor configuration
   • More accessories can be configured (divider
       panels, covers, etc.)
   •   Maxi-PLS and ISV can be configured as
       separate enclosures in a project.



   Thema oder Anlass des Vortrags       Autor / Abteilung / Datum   44
Maxi-PLS

• Prototype system with internal division,
   design 4a
    • with form subdivision Form 2-4 according
        to IEC 2 60439-1
    •   For rated currents up to 1600 A
    •   May be used as power distribution
        system (PCC) and control system
        (MCC).
    •   Modular interior installations with system
        components
    •   Flat bars or PLS bars may be selected
        from the RiLine60 program
    •   Available from October 2006



   Thema oder Anlass des Vortrags        Autor / Abteilung / Datum   45
Innovations 2006

SBU 3 System climate control




                MTS May 2006



                               ‹Nr.›
TopTherm & RiNano




     PLUS
     • RiNano-coated condenser in all cooling units

     • Electronic condensate evaporation integrated into all roof-
       mounted and wall-mounted units with cooling outputs of 1000
       watts or greater

  Thema oder Anlass des Vortrags   Autor / Abteilung / Datum         47
Enclosure cooling during the production of disc brakes
Application: Audi Ingolstadt




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   48
RiNano cooling unit

• SK 3305.100 / 1500 watts
   • Has been operated since June 2005
   • No filter mat
   • Has not been serviced so far

• Extreme condition:
   • Dust
   • High ambient temperatures
   • High power loss inside the enclosure




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   49
Enclosure cooling during the production of disc brakes
Application: Audi Ingolstadt


• Existing units without RiNano have
   been used for 5 to 6 years

• The cooling units must serviced
   regularly to ensure that they operate
   continuously.

• Filter mats must be replaced every
   week!

• The picture shows a filter mat after 5
   days!


   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   50
TopTherm & RiNano

Benefits:
• Clean heat exchangers
• Longer maintenance intervals
• No power drop
• Higher energy efficiency
• Easier to clean
• No filter mats (dry dust)
• Longer downtimes (metal filters for oil-bearing air)




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   51
Condensate management

• Integrated condensate management
    • Requirements from the automobile industry
    • Risk of accidents  Puddles
    • Specified by the US automotive
        industry


• RTT cooling unit series with integrated
   condensate evaporation
    • For all roof-mounted and wall-mounted units
       from 1000 watts on




   Thema oder Anlass des Vortrags        Autor / Abteilung / Datum   52
Condensate management




 Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   53
Air/water heat exchangers

New series
• 500 to 5000 watts

• 230 V, 115 V and 400 V, 2~,

• Optionally with basic or comfort controller

• Slimline design

• Comes with all water-carrying parts in V4A
   -1.4571



   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   54
Air/water heat exchangers
                                    Mounting cut-outs suitable for
                                   “mounting” on RTT wall-mounting
                                   cooling units




  Thema oder Anlass des Vortrags            Autor / Abteilung / Datum   55
Innovations 2006

SBU 3
Recooling systems




                MTS May 2006



                               ‹Nr.›
Recooling systems

• Wall-mounted, 4,000 watts

• RiNano-coated as standard

• Controlled via Microcontroller Box (MCB)
   • Individual fault messages are processed by the
       display and the diagnosis software




   Thema oder Anlass des Vortrags           Autor / Abteilung / Datum   57
Innovations 2006

SBU 6
Outdoor & fuel cells




                  MTS May 2006



                                 ‹Nr.›
Toptec CR

• 4 dimension variants
   • W: 600/800 x H:1,200/1,600 x D: 600 mm

• Welded vertical section with roof and bottom
  (base/plinth integrated) made of V2A stainless
  steel

• Twin-walled doors and side panels made of
  zinc-plated sheet steel

• Rain canopy made of aluminium

• Fully spray-finished in RAL 7035
   Thema oder Anlass des Vortrags    Autor / Abteilung / Datum   60
Toptec CR


• Simple baying, since there is no side
   roof projection

• Toptec cooling modules may be used

• Lifting eyebolts are not included in the
   supply. Rain canopy must be dismantled if
   the unit is transported by crane

• Double side panel at the inside which means
   that the outer TS8 frame level can only be
   accessed with difficulty

   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   61
Toptec CR

• Door stay
   • Made of round steel, opening range: 90°,
       115° or 130°
   •   More robust than the old version


• Door handle
   • Swing lever with direct access to the semi-
       cylinder




  Thema oder Anlass des Vortrags          Autor / Abteilung / Datum   62
Toptec CR accessories

• Toptec concrete base/plinth
   • 600 / 800 mm wide
   • 600 mm deep

• Depth stay for Toptec CR
   • For W: 800 mm D: 600 mm
   • Mounted on the inner level

• Assembly kit
   • In the enclosure depth
   • For attaching mounting plates / swing frames




   Thema oder Anlass des Vortrags      Autor / Abteilung / Datum   63
Fuel cell technology
• 3 different applications and output categories
Small applications                  Outdoor UPS                      Indoor UPS
up to 250 watts                     From 3 to 15 kW                  From 10 to 200 kW


      Project solution                   Catalogue                       Concept




   Thema oder Anlass des Vortrags            Autor / Abteilung / Datum                   64
Innovations 2006

SBU 5
Rittal Smart Package, racks and
accessories




                 MTS May 2006



                                  ‹Nr.›
Rittal Smart Package

• Pre-configured TS8 server racks
    • 800 mm wide, 42 U, 1000 mm deep

• In different designs for small and
   medium-sized companies:
    • Integrated PSM busbar
    • 2 kVA or 3 kVA UPS installed
    • Different climate control concepts:
        • Slotted doors
        • Roof-mounted fan
        • Wall-mounted cooling unit on the rear
            door
    •   With CMC-TC installed in some cases




   Thema oder Anlass des Vortrags        Autor / Abteilung / Datum   66
TS8/HPC network and server enclosures

Server enclosures, 1200 mm deep,
• 2000 + 2200 mm high
• RAL 7035 / 9005
• Standard mounting angles

HPC (High Power Cooling) enclosures, 1200 mm
  deep,
• WxH 600 / 800 x 2000 mm
• To be combined with LCP/LCP
• Protection category up to IP 55
• 482.6 mm (19") mounting frame
• Load capacity up to 1000 kg max.

   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   67
Accessories

• DK-TS side panels
     • May be screw-fastened / plugged
     • 2000 / 2200 high
•   TS roof plate
     • for cable entry, two-piece
     • 600 / 800 mm wide

• Interior installation:
     • TS punched section with mounting
         flange 17 x 73 mm, outer level
         (notched!)
     •   DK C rails
     •   TS cable clamp rails for TS and 482.6
         mm (19") mounting frames



    Thema oder Anlass des Vortrags          Autor / Abteilung / Datum   68
Accessories

• DK stabiliser, pull-out
    • Load capacity up to 150 kg

• System supports for cable routes
    • For 800 - 1200 mm deep enclosures

• TS base/plinth in RAL 9005 and
   7035
    • More dimensions

• TS punched section with
   mounting flange 17 x 73 mm
    • With slots
    • for 900, 1000, 1200 mm width /
       depth


   Thema oder Anlass des Vortrags      Autor / Abteilung / Datum   69
Accessories

TS partition
• HxD 2000/2200 x 1000/1200 mm

• For sliding in and partitioning
   retrospectively, especially in
   conjunction with climate control
   components in enclosures suites

• With concealed cut-outs in all
   corners for routing cables and
   leads between the enclosures




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   70
Accessories

TS IT glazed door
• Aluminium frame section in a new
  design
• Integrated hinges
• 180° opening even when bayed
• New, flat handle system
• It is possible to conceal the cable
  routing to the handle and to the
  sensorics
• Dimensions
    • Width: 600 / 800 mm
    • Height: 800 - 2,200 mm
• Standard glazed door in IT
  Catalogue 2006!

   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   71
Accessories

TS infill panel
• for network enclosure, 800 mm wide
• Installation height: 33, 38, 42, 47 U
• Large cable storing space
• May be combined with large shunting
  ring
• May be fastened on the vertical frame
  section, at the inside
• Depth-variable, on the punched section,
  inside
• Hinged version
• Open/closed action point

   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   72
Accessories

• Cable anchor (black)
    • Size of the shunting ring 1 U / 4 U
    • Cranked for mounting angles and
        mounting frames
    •   Especially for mounting on all panels
        such as punched sections, cable
        channels, frames


• Distributor ring (chrome-plated)
    • For cascaded cable routing
       • to mounting angles and mounting
             frames
         •   to all panels


   Thema oder Anlass des Vortrags       Autor / Abteilung / Datum   73
Accessories

• Slide rail, 740 mm, stationary
   installation
    • Matches HP standard dimensions, 740
        mm distance between the levels
    •   100 kg static load


• Depth-variable slide rail, 1 U
    • 80 kg static load
    • 390-600 / 590-930 mm long
    • Particularly slimline design

• Potential equalisation point
    • Star point for earthing bolt
    • Contacts up to 5 earthing straps with 6.3
        mm flat-pin connectors


    Thema oder Anlass des Vortrags        Autor / Abteilung / Datum   74
Innovations 2006

SBU 5 PSM and UPS
(uninterrupted power supply)




                 MTS May 2006



                                ‹Nr.›
PSM Plus busbar and modules

• Power System Module PSM Plus
  with four infeeds

• 3-phase / redundant design

• Different module versions,
  sometimes with double infeed

• Can distribute twice as much
  power as the latest PSM, i.e. 192
  A/busbar



   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   76
PSM system

• PSM with 3-phase voltage monitoring
   • Displays and monitors the connection current
     and the active power / phase
   • For 2000 mm high enclosures with 6 slots
   • Remote monitoring via CMC-TC

• PSM accessories
   • Cable lock: connection cable
   • For all modules with IEC320 C13 jack

• PSM light module
   • For use as a portable lamp with a NiMH battery
   • 3 hours illumination time and magnetic
       attachment


   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   77
Static transfer switch (STS)

Available upon request:
• 482.6 mm (19") design, 2 U
• Switches automatically between two
  infeeds
• Increases availability through
  redundancy
• Single-phase switching load: 16 A
• Networking capability (SNMP)
• May be applied in the IT business
   •   Server racks
   •   Network racks
   •   Data centres
   •   Networks in general

   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   78
UPS PMC 200, 2nd generation

• UPS modules 10/20 kW
   • 600 mm wide racks

• UPS modules 30/40 kW
   • 800 mm wide racks

• Improved efficiency (96%)

• Redundant n+1 system
  architecture in modules and
  batteries

• See IT News 2006, p. 20-26
   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   79
UPS PMC 200, 2nd generation

• Benefits
   • Flexible, simple expansion with the
     system operational
   • The fact that modules can be
     replaced easily make servicing fast
     and cost-effective

• May be applied in the IT business
   • Data centres, IP telephony
   • Networks in general

• May be applied in the IE business
   • Mechanical engineering in general
   • Automotive


   Thema oder Anlass des Vortrags    Autor / Abteilung / Datum   80
UPS PMC 200, 2nd generation




N+1 redundancy in an example with 40 kW




1+1, 40kW modules                   2 + 1, 20kW modules                  4 + 1, 10kW modules

   Thema oder Anlass des Vortrags            Autor / Abteilung / Datum                   81
Innovations 2006

SBU 5 Security / monitoring




                 MTS May 2006



                                ‹Nr.›
CMC-TC

• New CMC-TC software functions
   •   New web design
   •   Network Time Protocol NTP
   •   SSL and SSH
   •   DHCP


• Applications
   • Large network systems
   • RimatriX5 data centre

Customer benefits: More comfort, more security, more transparency




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum       83
CMC-TC accessories

• Display Unit II
    • Graphical, illuminated LED display
    • Displays temperature, humidity, access,
        climate control units, LCP, ActivePSM and
        PCU
    •   The network interface of PU II may be set
        via keys
    •   Power supply via PU II


• Applications
    • Applications without network
    • Informs locally



   Thema oder Anlass des Vortrags     Autor / Abteilung / Datum   84
                                                                U1                 U2
CMC-TC accessories




                                                                        7200.210




                                                                                        7200.210
Redundant power supply for CMC-TC
• Two voltage inputs, one voltage output




                                                                     7320.425




                                                                                        7320.425
• Switches without interruption
• With power pack for 90-230 VAC or 48VDC
• For 24 V DC
• Alarm interface with the I/O unit
                                                                 24 V DC
• Optical alarm display
                                                                                                   Alarm
                                                                                                   U1 / U2




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum                                 85
CMC-TC accessories

• Voltage monitor with 16 A C19/C20
  switched output
   • Switches high currents 16 A
   • In de-energised state: ON
   • Switches high-performance IT/server
       components up to 16 A


• 1 U fixture for CMC-TC sensors
   • Accommodates up to 22 CMC-TC
       sensors
   •   Cable clamping




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   86
CMC-TC accessories

• Comfort handle for TS8 Legic (WO)
   • Legic transponder technology
         • Receiver aerial in the handle
         • Acoustic/optical signal in the handle
   • Electronics in the CMC-TC housing
         • Carrier frequency: 13.56 MHz

• Biometric access system (WO)
   •   Thermal sensor
   •   Compatible with the CMC access system
   •   Up to 99 users / 10 fingers for each user
   •   May be used outdoors




   Thema oder Anlass des Vortrags          Autor / Abteilung / Datum   87
SSC Rittal KVM technology

• SSC compact 8
   • Inexpensive KVM switch based
     on standard PC interfaces, 1 U
   • Compatible with VGA & PS/2
   • Compatible with other servers
     via adaptors
   • May be combined with SSC
     multi (without OSD transfer)
• SSC compact 32 Cat
   • 32 server ports in 1 U
   • For SSC: converters for PS/2,
       USB & SUN-USB
   •   May be cascaded to up to three
       more SSCs; max. 125 servers
       on one user (with OSD transfer)


   Thema oder Anlass des Vortrags     Autor / Abteilung / Datum   88
SSC Rittal KVM technology

SSC compact
• Password-protected OSD menu
  for configuration and server
  selection
• Selection may also be made via
  hotkeys
• Convenient function such as
  autoscan and autoskip
• May be installed in 482.6 mm
  (19") levels
• Integral wide-range power pack,
  IEC 320 connection (EN 60320,
  C14, 100 V-240 V AC 50/60 Hz)

   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   89
Innovations 2006

Cooling




           MTS May 2006



                          ‹Nr.›
LCP Liquid Cooling Package

• LCP Standard
• Additional dimensions
     • WxHxD: 300 x 2000 x 1,200 mm
•   Connector system replaces the
    hose clamps
•   Solid base tray designed as
    condensate tray
• Condensate is drained off either via
  return to to the outside
• Main connection is at the rear or
  bottom




    Thema oder Anlass des Vortrags    Autor / Abteilung / Datum   91
LCP Liquid Cooling Package

LCP Extend
• Extends existing room air-conditioning
• Cooling output about 10 kW per rack
• May be retrofitted on rear doors of
  vented enclosures
• Bayable, door opening max. 90°
• Water connection from below or
  above
• May be connected to CMC /
  RiWatchIT
• Compatible with Rittal IT cooling unit
  line


   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   92
LCP Liquid Cooling Package

LCP +
• Same as standard LCP, but with higher
  output
• Cooling output 30 kW
• WxHxD: 300 x 2000 x 1,200 mm
• Easy servicing for important components
  (e.g. fans can be replaced without tools)
• Active condensate management
• Cooling even with the server rack doors
  open
• May be connected to CMC / RiWatchIT


   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   93
LCP accessories

• Vertical shielding
    • May be used HPC server racks
    • Prevents "air short circuits"
    • Horizontal shielding

• Air inlet/outlet of the cover plate
    • May be used in the LCP rack

• Top-mounted cover for LCP (200 mm)
    • May be adapted to 2200 high server racks




    Thema oder Anlass des Vortrags      Autor / Abteilung / Datum   94
LCP accessories

• LCP ventilation for maintenance
  works and retrofitting

• Connection hose

• Quick-release couplings for
  configuring water connections




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   95
IT recooling systems

• Requirements specific to Rimatrix
• Pressure-sealed systems
• Field of application: -20°C to +45°C
  (outdoor siting)
• May be connected to CMC and
  collective fault signal
• Increased safety through twin pump
  and redundant cooling circuits




   Thema oder Anlass des Vortrags   Autor / Abteilung / Datum   96
IT recooling systems
                                               Power range of RiMatrix recooling systems in kW
 Recooling systems
                      4   8   10   12   20   24 30 36 40 48 50 60 70 80 84 90 100 110 120 130 140 150
    SK 3301.900
    SK 3301.901
    SK 3301.902
    SK 3301.905
    SK 3301.910
    SK 3301.912
    SK 3301.915
    SK 3301.920
    SK 3301.925
    SK 3301.930




                     Example                             Project
                                                         business:
                     Recooling systems SK
                     3300.902                            Example AWE
                     Cooling output12,000
                                                         Cooling output
                     watts
                     at Tw = 15°C and Ta = 32°C          4x280 kW



  Thema oder Anlass des Vortrags                    Autor / Abteilung / Datum                  97

				
DOCUMENT INFO
Shared By:
Categories:
Tags:
Stats:
views:1
posted:1/5/2013
language:Latin
pages:96