Optimisation of Data Integration with Pro ENGINEER Meduser

W
Shared by: benbenzhou
Categories
Tags
-
Stats
views:
1
posted:
12/5/2012
language:
English
pages:
15
Document Sample
scope of work template
							Optimizing of Data Integration
     with Pro/Engineer

          Dr. Josip Stjepandic
                 Cooperation
                 in a Network

       BMW            DCAG              GM             Ford          VW             Volvo           …

OEM



1st tier     Delphi   Bosch       Conti      Siemens    Hella       FuBa       ZF        VDO        …




2nd tier
...      a       b    c       d     e        f    g      h      i      j   k         l      m   n


    Each relationship requires            – Harmonization of inter-company processes
                                          – Harmonization of data formats
                                          – Harmonization of implementation methods
Data Exchange Vision




                 Datenaustausch
              Modell versenden an:
                                                                        j
         Firma: Schnell AG

    Abteilung: Konstruktion

         Name:                                                                                    Datenaustausch
                 Müller
                                                                                              Modell versenden an:
                   Meldungen:
                                                                                         Firma:   Schnell AG
- Modell erfolgreich versendet
- Modell bei Hell AG erfolgreich empfangen                                          Abteilung: Konstruktion

                                                                                         Name:
                                                                                                  Müller
    OK                                   Cancel
                                                                                                    Meldungen:
                                                                                - Modell erfolgreich versendet
                                                                                - Modell bei Hell AG erfolgreich empfangen



                                                                                    OK                                   Cancel




         Sending System                                                        Receiving System
                                                  • 100 % Translation
                                                  • “As in receiving System created”
                                                  • “Ready for PDM”
                                                  • Automated Process
 Reasons for Data
 Exchange Problems
Entities which
    can be                                                         Entities which
represented in                                                         can be
   System A                                                        represented in
                                                                      System B
                                            Direct
                 Mappable    Mappable
                                         transferable
                  entities    entities
                                            entities


          Entities which
              can be
          represented in
            the neutral
              format           1 Different use of the CAD system

                               2 Processor error

                               3 Accuracy differences

                               4 User errors
           Accuracy Differences
            Sending System                             Receiving System

 Surface
                                             Surface


 Face




                                Projection
                                distance D
                                < Limit D1

1 Tolerance limit in sending system D1 ist higher
   than in receiving system D2.

2 Faces with large projection distance (D1> D > D2)
  can‘t be imported into receiving system.
Solutions for Data
Exchange Problems
Sending System   Receiving System




                 1 Application rules / Data creation standards

                     •VDA 4950, 4955 ...

                 2 Improvements of the standard interfaces


                 3 Adaption / Geometry healing
     Scaling of Solutions



 Degree of
Outsourcing,
 User Know
    How




               Consulting   SW Solution    Full Service
                              (HOP)       (OpenDESC)

                                                          Complexity,
                                                           Amount
 Optimal Process Design

• Requirement analysis for the DE partnership
• Optimal system setup
• Ensure of the high quality of the original models by
  preventive actions (design methodics, continuously user
  training, regular quality checks, usage of the quality
  checker)
• Usage of the highly optimized pipelines on your site or as
  service in web

 On very complex tasks the single actions are combined.
  Available Pipelines


                        CGS




CADDS                   UGMX




                         Migration
Highly optimized Pipeline
Pro/Engineer-CATIA


                                                                     DXM
                                                        User interface, Process control
             Simplifying
             Optionally




                                                                                                                     Optimator
                                    STEP Processor             PSstep_Adapter             STEP Processor

    Native                 native
                                        (3D)                        (3D)                     (AP214)       native
                                                      STEP-                     STEP-                                            Native
    Modell                 model´                     Datei                     Datei‘                     model                 Modell‘
                            (3D)                       (3D)                      (3D)                      (3D)                   (3D)

Pro/Engineer                                                                                                                               CATIA


                                     IGES Processor            PSiges_Adapter             IGES Processor

             Native                       (2D)        IGES-
                                                                    (2D)        IGES-
                                                                                              (2D)                  Native
             Modell                                    Datei                    Datei‘                              Modell
              (2D)                                     (2D)                      (2D)                               (2D)
Geometry Healing


                   Gap reduced from
                   0.5 mm to 0.02 mm!
OpenDESC®:
 www.opendesc.com
ProSTEP Data Exchange Manager


                       ProSTEP Data Exchange Manager - DXM®
                                                              *



                                                             Archiving
                        Adapter    Pre-/       Quality      Inspection
                        Quality    post-                     Transport
                                   processor   examiner
                        check                               Packaging
                                                          Administration


   CAD/CAM                                                                 CAD/CAM-System
   System




* Patent applied for
BMW PICANT Pipeline

 PRISMA 98 Client           Migration Client                                          Pro/I
                                                                                     Client


                                                               PRISMA
                                                               CORBA
                                                                Client
                                                             Trigger DLL




     SQL*NET V2           PRISMA                 PRISMA
                          CORBA                  CORBA
                           Server                 Client
                                               Trigger DLL

                           Pro/I                 Pro/I
                          CORBA      IIOP       CORBA
                           Client               Server




                                                                                   Pro/
  PRISMA                      PRISMA PRESTO Pro/I
                              Adapter DXM  Adapter                         INTRALINK
                                                                           Pro/E
                  CATIA                                                    Files
                  Files
Customer List

						
Related docs
Other docs by benbenzhou
Green Tea Colostrum
Views: 22  |  Downloads: 0
Engr Intro to Engineering
Views: 1  |  Downloads: 0
A BASIC OIL Jojoba Oil
Views: 269  |  Downloads: 0
Palaro_B_030810
Views: 36  |  Downloads: 0
MIT ALOE VERA
Views: 6  |  Downloads: 0