Certificate of Compliance Support Siemens

					                 Certificate of Compliance
        Certificate:      1458768                                              Master Contract:   165071

        Project:          2511549                                              Date Issued:       March 26, 2012
        Issued to:        Siemens AG
                          I IA CE CP R&D-VI 4
                          Werner-von-Siemens-Strasse 48
                          Amberg, 92220
                          Germany
                          Attention: Mr. Michael Schröck


                           The products listed below are eligible to bear
                           the CSA Mark shown with adjacent indicator


                                                                                  J.-C. Chow
                                                                       Issued by: J.-C. Chow



        PRODUCTS
        CLASS 3211 37       - INDUSTRIAL CONTROL EQUIPMENT - Sub-Assemblies - Components

        Motor Feeder/Branch Circuit 3-phase busbar system, open type, Types 3RV1917, 3RV1927, 3RV2917 and
        3RV2927 with the following components and ratings:
        • Type 3RV1917 followed by -1A or -1E: max 80 A, 600 Vac
        • Type 3RV1917 followed by -4A, -4B, -5A, -5C, -5BA or -5E; Type 3RV1927-5A; Type 3RV2917followed by
          -1A, -1E, -4A, -4B, -5A, -5C, -5BA or -5E; Type 3RV2927-5A: max 63 A, 600 Vac
        • Types 3RV1917-5D and 3RV2917-5D: max 30 A, 600 Vac
        Standard short circuit rating for any combination of:
        • Type 3RV1917-1A, -1E, -4A, -4B, -5A, -5BA, -5C, -5D, -5E; Type 3RV1927-5A; Type 3RV2917-1A, -1E,
           -4A, -4B, -5A, -5BA, -5C, -5D, -5E; Type 3RV2927-5A: 10kA/600V with max fuse 300A/Class K5, RK5,
           RK1 or J
        High fault short circuit rating for any combination of:
        • Type 3RV1917-1A, -1E, -4A, -4B, -5A, -5BA, -5C, -5D, -5E; Type 3RV1927-5A: 50kA/480V with max fuse
          300A/Class K5, RK5, RK1 or J
        • Type 3RV2917-1A, -1E, -4A, -4B, -5A, -5BA, -5C, -5D, -5E; Type 3RV2927-5A: 65kA/480V with max fuse
          300A/Class K5, RK5, RK1 or J




DQD 507 Rev. 2009-09-01                                      Page: 1
    Certificate:          1458768                                            Master Contract:       165071

    Project:              2511549                                            Date Issued:           March 26, 2012



    Accessories:
    • Type 3RV1917 followed by -6A or -7A
    • Types 3RV2917-6A and 3RV2927-7A

    Notes:
    1. Certified as open type component for use only in Certified equipment where the acceptability of combination
    is to be determined by CSA International.
    2. Certified for use with Types 3RV101, 3RV1.21, 3RV2.11 and 3RV2.21 manual or combination motor
    controllers by Siemens.
    3. Types 3RV1917 and 3RV1927 are Certified for 60°C ambient when used with Type 3RV101 manual starters
    are loaded up to 100% full load current, or with Type 3RV1.21 manual starters are loaded up to 87% full load
    current; are Certified for 40°C ambient when used with Type 3RV1.21 manual starters are loaded up to 100%
    full load current.
    4. Types 3RV2917 and 3RV2927 are Certified for 40°C ambient when used with manual or combination motor
    controllers Type 3RV2.11 rated up to 16 A, or with Type 3RV2.21 rated up to 25 A, are loaded up to 100% full
    load current, or when used with Type 3RV2.21 rated 25 A up to 32 A are loaded up to 87% full load current.
    5. These devices when used with Combination Motor Controller Type 3RV1.2, 3RV2.1 or 3RV2.2, the short-
    circuit protection device (SCPD) is not required.
    6. Types 3RV1917-5D and 3RV2917-5D when used with this manufacturer Certified Type 3RA68, 3-ph
    busbars system are rated for standard short-circuit: 10kA at 600V with 250A max fuse/Class K5, RK5, RK1 or
    J; and for high-fault short-circuit: 30kA at 480V with 300A max fuse/Class K5, RK5, RK1 or J.
    7. The type designation may be completed with suffixes for electrical and mechanical details.

    APPLICABLE REQUIREMENTS
    CSA-C22.2 No. 14-10 - Industrial Control Equipment




DQD 507 Rev. 2009-09-01                                           Page: 2
                                                                                                    Descriptive Report
                                                                                                      and Test Results


                                                                                             MASTER CONTRACT: 165071
                                                                                                      REPORT: 1458768
                                                                                                     PROJECT: 2511549

    Edition 1:         November 5, 2003; Project 1458768 - Montreal
                       Issued by M. Legault, Eng.

    Edition 2:         February 28, 2007; Project 1881013 - Montreal
                       Issued by J.-C. Chow, Eng.; Reviewed by M. Legault, Eng.

    Edition 3:         October 30, 2009; Project 2225256 - Montreal
                       Issued by J.-C. Chow, Eng.

    Edition 4:         June 17, 2010; Project 2319133 - Montreal
                       Issued by J.-C. Chow, Eng.

    Edition 5:         June 17, 2011; Project 2434141 - Montreal
                       Issued by J.-C. Chow, Eng.

    Edition 6:         March 26, 2012; Project 2511549 - Montréal
                       Issued by J.-C. Chow, Eng.

                       Report pages reissued

                       Contents:        Certificate of Compliance - Pages 1 to 2
                                        Supplement to Certificate of Compliance - Page 1
                                        Description and Tests - Pages 1 to 13
                                        Att1 Figures - Fig. Nos. 1 to 13
                                        Att2 Illustrations - Ill. Nos. 1 to 6
                                        Att3 Test Reports - Nos. 03046W-u (15 pages), 05060W-u (10 pages), 07056W-
                                        U04b (24 pages)

    PRODUCTS

    CLASS 3211 37 - INDUSTRIAL CONTROL SUB-ASSEMBLIES - Components

    Motor Feeder/Branch Circuit 3-phase busbar system, open type, Types 3RV1917, 3RV1927, 3RV2917 and
    3RV2927 with the following components and ratings:
    - Type 3RV1917 followed by -1A or -1E: max 80 A, 600 Vac
    - Type 3RV1917 followed by -4A, -4B, -5A, -5C, -5BA or -5E; Type 3RV1927-5A; Type 3RV2917followed by
    -1A, -1E, -4A, -4B, -5A, -5C, -5BA or -5E; Type 3RV2927-5A: max 63 A, 600 Vac
    - Types 3RV1917-5D and 3RV2917-5D: max 30 A, 600 Vac
                                    The posted report does not be represent the full certification report.


                                         865 Ellingham Street, Pointe-Claire, Québec, Canada H9R 5E8
                             Telephone: 514.694.8110 1.800.463.6727 Fax: 514.694.5001 www.csa-international.org
DQD 507.10 Rev. 2012-02-22
    MASTER CONTRACT: 165071
    REPORT: 1458768                                                                                    Page No: 2
    PROJECT: 2511549                                                                   Date Issued: March 26, 2012



    Standard short circuit rating for any combination of:
    - Type 3RV1917-1A, -1E, -4A, -4B, -5A, -5BA, -5C, -5D, -5E; Type 3RV1927-5A; Type 3RV2917-1A, -1E, -
    4A, -4B, -5A, -5BA, -5C, -5D, -5E; Type 3RV2927-5A: 10kA/600V with max fuse 300A/Class K5, RK5, RK1
    or J

    High fault short circuit rating for any combination of:
    - Type 3RV1917-1A, -1E, -4A, -4B, -5A, -5BA, -5C, -5D, -5E; Type 3RV1927-5A: 50kA/480V with max fuse
    300A/Class K5, RK5, RK1 or J
    - Type 3RV2917-1A, -1E, -4A, -4B, -5A, -5BA, -5C, -5D, -5E; Type 3RV2927-5A: 65kA/480V with max fuse
    300A/Class K5, RK5, RK1 or J

    Accessories:
    - Type 3RV1917 followed by -6A or -7A
    - Types 3RV2917-6A and 3RV2927-7A

    Notes:
    1.        Certified as open type component for use only in Certified equipment where the acceptability of
              combination is to be determined by CSA International.
    2.        Certified for use with Types 3RV101, 3RV1.21, 3RV2.11 and 3RV2.21 manual or combination motor
              controllers by Siemens.
    3.        Types 3RV1917 and 3RV1927 are Certified for 60°C ambient when used with Type 3RV101 manual
              starters are loaded up to 100% full load current, or with Type 3RV1.21 manual starters are loaded up to
              87% full load current; are Certified for 40°C ambient when used with Type 3RV1.21 manual starters are
              loaded up to 100% full load current.
    4.        Types 3RV2917 and 3RV2927 are Certified for 40°C ambient when used with manual or combination
              motor controllers Type 3RV2.11 rated up to 16 A, or with Type 3RV2.21 rated up to 25 A, are loaded up
              to 100% full load current, or when used with Type 3RV2.21 rated 25 A up to 32 A are loaded up to 87%
              full load current.
    5.        These devices when used with Combination Motor Controller Type 3RV1.2, 3RV2.1 or 3RV2.2, the
              short-circuit protection device (SCPD) is not required.
    6.        Types 3RV1917-5D and 3RV2917-5D when used with this manufacturer Certified Type 3RA68, 3-ph
              busbars system are rated for standard short-circuit: 10kA at 600V with 250A max fuse/Class K5, RK5,
              RK1 or J; and for high-fault short-circuit: 30kA at 480V with 300A max fuse/Class K5, RK5, RK1 or J.
    7.        The type designation may be completed with suffixes for electrical and mechanical details.


    APPLICABLE REQUIREMENTS

    CAN/CSA-C22.2 No. 0-M91           -       General Requirements - Canadian Electrical Code, Part II
    CSA-C22.2 No. 14-10 -             Industrial Control Equipment




DQD 507.10 Rev. 2012-02-22
    MASTER CONTRACT: 165071
    REPORT: 1458768                                                                                    Page No: 3
    PROJECT: 2511549                                                                   Date Issued: March 26, 2012

    MARKINGS

    Submittor’s name or tradename “Siemens” and/or CSA File number “LR 12730” and/or CSA Master Contract
    number “165071”, type designation, electrical ratings and CSA Component Acceptance Mark with the
    Component Acceptance (Triangle) indicator appear on an adhesive label and/or printed on the cover in a
    permanent manner.

    Note: For Feeder and Extension modules, Types 3RV1917-1A, 3RV1917-1E, 3RV1917-4A, 3RV1917-4B,
    3RV2917-1A, 3RV2917-1E, 3RV2917-4A, 3RV2917-4B, only the submittor’s identification, designation and
    electrical rating appear on the device, and other above markings may appear on the smallest packaging
    carton/label, or on the instruction sheet included with the device. Accessories are provided with same rating as
    the modules.

    The following or equivalent may be marked on the Feeder and Extension modules, Types 3RV1917-1A,
    3RV1917-1E, 3RV1917-4A, 3RV1917-4B, 3RV2917-1A, 3RV2917-1E, 3RV2917-4A, 3RV2917-4B:
    “SURROUNDING AIR TEMPERATURE 60°C”, if rated current for Type 3RV1011
    “SURROUNDING AIR TEMPERATURE 40°C”, if rated current for Type 3RV1.21
    “SURROUNDING AIR TEMPERATURE 60°C”, if current down rated to 87% for Type 3RV1.21
    “SURROUNDING AIR TEMPERATURE 40°C”, if rated current for Type 3RV2.11
    “SURROUNDING AIR TEMPERATURE 40°C”, if rated current for Type 3RV2.21 up to 25A
    “SURROUNDING AIR TEMPERATURE 40°C”, if current down rated to 87% for Type 3RV2.21 rated 25 A up
    to 32A

    The following or equivalent may be marked on the Feeder and Extension modules, Types 3RV1917-1A,
    3RV1917-1E, 3RV1917-4A, 3RV1917-4B, 3RV1917-5D, 3RV2917-1A, 3RV2917-1E, 3RV2917-4A, 3RV2917-
    4B:
    SUITABLE FOR MOTOR GROUP INSTALLATION ON A CIRCUIT CAPABLE OF DELIVERING NOT
    MORE THAN xxxxx RMS SYMMETRICAL AMPERES, yyyV MAX, WHEN PROTECTED BY A FUSE
    TYPE K5 (RK5, RK1 OR J) WITH A MAXIMUM RATING OF 300A”, where
          xxxxx = short circuit current rating;
          yyy = voltage rating;
          Refer to “PRODUCTS” section for Standard or High-fault short-circuit ratings.

    The following or equivalent may be marked on the Terminal blocks, Types 3RV1917-5D, 3RV2917-5D:
    SUITABLE FOR MOTOR GROUP INSTALLATION ON A CIRCUIT CAPABLE OF DELIVERING NOT
    MORE THAN xxxxx RMS SYMMETRICAL AMPERES, yyyV MAX, WHEN PROTECTED BY A FUSE
    TYPE K5 (RK5, RK1 OR J) WITH A MAXIMUM RATING OF 250A with 3RA68”, where
          xxxxx = short circuit current rating;
          yyy = voltage rating;
          Refer to “PRODUCTS” section for Standard or High-fault short-circuit ratings.

    The following or equivalent is marked on the Connectors, Plug and Terminal blocks, Types 3RV1917-5A,
    3RV1917-5BA, 3RV1917-5C, 3RV1917-5E, 3RV1917-5D, 3RV2917-5A, 3RV2917-5BA, 3RV2917-5C,
    3RV2917-5E, 3RV2917-5D:
    “WARNING DO NOT CONNECT OR UNPLUG UNDER LOAD”



DQD 507.10 Rev. 2012-02-22
    MASTER CONTRACT: 165071
    REPORT: 1458768                                                                                    Page No: 4
    PROJECT: 2511549                                                                   Date Issued: March 26, 2012

    For Cage Clamp of Feeder Module Terminal, Types 3RV1917-1A, 3RV1917-1E, 3RV2917-1A, 3RV2917-1E:
              “AWG 10-3”

    For Cage Clamp of Terminal Block, Types 3RV1917-5D, 3RV2917-5D:
              “AWG 18-10”

    Installation instruction is provided with each unit.


    ALTERATIONS

    The markings are in accordance with the “MARKINGS” paragraph above.


    FACTORY TESTS

    The equipment, at the conclusion of manufacture and before shipment, shall withstand for one minute, without
    breakdown, the application of twice rated voltage plus 1000 V between live parts and metal parts, which may be
    grounded, on a basis of at least 3% of the daily production intended to bear the CSA Monogram.
    The factory test may be made at existing room temperatures.
    As an alternative, a potential 20 per cent higher may be applied for one second.
    As an alternative, method based on IEC 410 and in accordance with submittor’s ISO 9001 Quality program.

    Warning: These tests may present a hazard of injury to personnel and/or property and should only be performed
    by persons knowledgeable of such hazards and under conditions designed to minimize the possibility of injury.


    SPECIAL INSTRUCTIONS FOR FIELD SERVICES

    1.        Component Substitution
              a) Critical components (those identified by mfr name, cat no) are not eligible for substitution without
                 evaluation and report updating.
              b) Component descriptions marked with the identifier “(INT)” are the only components that are eligible
                 for substitution at the factory.
              c) Substitution of a CSA Certified component with a component “Certified” or “Listed” by another
                 organization may result in annual sample pickup and Conformity Testing.
              d) Substitution of a “Certified” or “Listed” component with a component that is “Recognized” or
                 “Accepted” is not permitted without evaluation and report updating.


    COMPONENT SPECIAL PICKUP

    None.




DQD 507.10 Rev. 2012-02-22
    MASTER CONTRACT: 165071
    REPORT: 1458768                                                                               Page No: 5
    PROJECT: 2511549                                                              Date Issued: March 26, 2012

    DESCRIPTION

    Notes:
    1.     The term “(INT)”, following the component name, denotes a certified component that can be replaced by
           another CSA Certified component or one certified by another certification organization (accredited by
           OSHA/SCC), for the same application, provided that it has an equivalent rating, configuration (size,
           orientation, mounting) and that applicable minimum creepage and clearance distances are maintained
           from live parts to bonded metal parts and secondary parts..
    2.     The term “(CT)”, following the component name, denotes a component that is subject to periodic re-
           testing unless evidence of re-testing equivalent to the CSA program is available.

    General: Motor Feeder/Branch Circuit 3-Phase Busbar System, Types 3RV1917, 3RV1927, 3RV2917 and
    3RV2927 with following Components:
           3RV1917-1A            Feeder Module left, for 3RV1.1 or 3RV1.2
           3RV1917-1E            Feeder Module right, for 3RV1.1 or 3RV1.2
           3RV1917-4A            Extension Module, for 2 Manual Starters 3RV1.1
           3RV1917-4B            Extension Module, for 3 Manual Starters 3RV1.1
           3RV1917-5A            U-connector for Cage Clamp/Spring Terminal with 3RV1.1
           3RV1927-5A            U-connector for Screw Terminal with 3RV1.2 or 3RV2.2 (size S0)
           3RV1917-5C            U-connector for Screw Terminal with 3RV1.1
           3RV1917-5BA           Extension Plug, for 3RV19
           3RV1917-5D            Terminal Block, for 3RV19
           3RV1917-5E            Extension Plug, for 3RV19
           3RV1917-6A            End Cover, for 3RV19
           3RV1917-7A            Support socket, for Contactor 3RT1.1
           3RV2917-1A            Feeder Module left, for 3RV2.1 or 3RV2.2
           3RV2917-1E            Feeder Module right, for 3RV2.1 or 3RV2.2
           3RV2917-4A            Extension Module, for 2 Manual Starters 3RV2.1 or 3RV2.2
           3RV2917-4B            Extension Module, for 3 Manual Starters 3RV2.1 or 3RV2.2
           3RV2917-5A            U-connector for Cage Clamp/Spring Terminal with 3RV2.1 (size S00)
           3RV2927-5A            U-connector for Cage Clamp/Spring Terminal with 3RV2.2 (size S0)
           3RV2917-5C            U-connector for Screw Terminal with 3RV2.1 (size S00)
           3RV2917-5BA           Extension Plug, for 3RV29
           3RV2917-5D            Terminal Block, for 3RV29
           3RV2917-5E            Extension Plug, for 3RV29
           3RV2917-6A            End Cover, for 3RV29
           3RV2927-7A            Support socket for Contactor 3RT2.1 or 3RT2.2




DQD 507.10 Rev. 2012-02-22

				