					                                        Work Experience Form
                 Refrigeration and Air Conditioning Mechanic
                                         (Commercial - NOA)
Personal Information (please print)

___________________________________________________________________________________________________________
   Legal First Name                   Middle Initial         Legal Last Name            Birth Date (yy/mm/dd)

___________________________________________________________________________________________________________
   Address                                                   City/Town                  Postal Code

___________________________________________________________________________________________________________
   Home or Cell Phone                 Business Phone         E-mail address             Fax #




Eligibility Requirements for Trades Quilifications
In order for Trades Qualifiers (TQ) to be approved to challenge the certification exam in this compulsory trade, you must
have worked both a minimum of 7.5 years within the last 10 and accumulated 13,500 hours, as well as acquired at least
70% scope of the trade.

NOTE:
There is no provision for Designated Trainers in this compulsory trade. Trades Qualifies can apply to challenge the exam
through the TQ process. The application and information sheet can be found at www.manitoba.ca/tradecareers under
“Skilled Worker.”




Instructions
You are about to complete the Work Experience Form (WEF) which is based on the sub-tasks outlined in the National
Occupational Analysis (NOA). The NOA provides detailed information that will assist you when completing the WEF and is
your best source for identifying any training gaps. The link to the NOA is www.red-seal.ca.

Complete the following Work Experience Form and rate your experience for each sub-task.

   Circle #0 if I have no experience doing this.
   Circle #1 if I have a little experience doing this.
   Circle #2 if I have some experience doing this with help.
   Circle #3 if I have some experience doing this alone and unaided.
   Circle #4 if I have frequently done this.
   Circle #5 if I have extensive experience doing this.
The amount of questions in each section of the certification exam is identified next to each Block title on the WEF

Sign and date the completed Work Experience Form and return it to the Apprenticeship Manitoba with the relevant
application form and related documents. Keep one copy of the Work Experience Form for your records.



         1-877-97-TRADE                               www.manitoba.ca/tradecareers                                    rev. 06/12

         Thompson               The Pas               Brandon             Winnipeg
         118-3 Station Rd.      305 Fourth St. W      128, 340-9th St.    1010-401 York Ave.
         R8N 0N3                R9A 1M4               R7A 6C2             R3C 0P8
         204-677 -6346          204-627-8290          204-726-6365        204-945-3337
         Fax 204-677-6689       Fax 204-627-8137      Fax 204-726-6912    Fax 204-948-2346
Block A        Fundamental Occupational Skills (18 Questions)
                 Task                                               Sub-Tasks                         Rating

1. Utilizes mechanical and architec-      1.01 Interprets blueprints, drawings, and schematics.      01 2 345
tural drawings, acts, codes, standards,
legislation, and service and operating
manuals.

                                          1.02 Interprets service and operating manuals, technical   01 2 345
                                          bulletins, and warranties.

                                          1.03 Interprets tables, charts, and diagrams.              01 2 345

                                          1.04 Interprets manufacturer’s specifications.              01 2 345

                                          1.05 Complies with government acts, codes, standards,      01 2 345
                                          and regulations.




                 Task                                                 Sub-Tasks                       Rating

2. Operates and maintains tools and       2.01 Utilizes hand tools.                                  01 2 345
equipment.

                                          2.02 Utilizes portable and stationary power tools.         01 2 345

                                          2.03 Utilizes oxy-fuel and air-fuel equipment.             01 2 345

                                          2.04 Utilizes recovery and recycle equipment.              01 2 345

                                          2.05 Utilizes evacuation equipment and tools.              01 2 345

                                          2.06 Utilizes charging equipment and tools.                01 2 345

                                          2.07 Utilizes access/egress equipment.                     01 2 345

                                          2.08 Utilizes hoisting and rigging equipment.              01 2 345

                                          2.09 Utilizes mechanical measuring equipment.              01 2 345

                                          2.10 Utilizes electric and electronic diagnostic tools.    01 2 345

                                          2.11 Utilizes computer equipment to interface with         01 2 345
                                          refrigeration and air conditioning systems.




                 Task                                                 Sub-Tasks                       Rating

3. Demonstrates work practices and        3.01 Installs fasteners, brackets, and hangers.            01 2 345
procedures.
                                         3.02 Performs lock-out tagging and isolation procedures.     01 2 345

                                         3.03 Installs piping and tubing.                             01 2 345

                                         3.04 Applies sealants and adhesives.                         01 2 345

                                         3.05 Cleans and lubricates parts and components.             01 2 345

                                         3.06 Performs internal electrical wiring of systems.         01 2 345




                 Task                                             Sub-Tasks                            Rating

4. Coordinates refrigeration and air     4.01 Estimates work requirements.                            01 2 345
conditioning installation and mainte-
nance.

                                         4.02 Conducts work area inspection.                          01 2 345

                                         4.03 Coordinates work requirements.                          01 2 345

                                         4.04 Maintains customer relations.                           01 2 345

                                         4.05 Clarifies end user problems with refrigeration and air   01 2 345
                                         conditioning systems

                                         4.06 Completes work-related documentation.                   01 2 345

                                         4.07 Generates maintenance documentation.                    01 2 345




                 Task                                             Sub-Tasks                            Rating

5. Performs system components,         5.01 Requisitions equipment.                                   01 2 345
accessories, and materials acquisition
and handling.

                                         5.02 Receives materials/ equipment.                          01 2 345

                                         5.03 Transfers equipment to designated location.             01 2 345




Block B        Refrigeration and Air Cooling Systems (47 Questions)
                 Task                                             Sub-Tasks                            Rating

6. Plans installation of refrigeration and 6.01 Verifies refrigeration and air cooling system          01 2 345
air cooling systems.                       parameters and requirements.
                                         6.02 Selects refrigeration and air cooling components,      01 2 345
                                         equipment, and accessories.

                                         6.03 Prepares components, equipment, and accessories        01 2 345
                                         layout.

                                         6.04 Selects refrigerant.                                   01 2 345

                                         6.05 Sizes piping.                                          01 2 345

                                         6.06 Lays out piping.                                       01 2 345

                                         6.07 Selects insulation.                                    01 2 345




                 Task                                               Sub-Tasks                         Rating

7. Installs refrigeration and air cooling 7.01 Prepares site/location.                               01 2 345
systems.

                                         7.02 Assembles refrigeration and air cooling components,    01 2 345
                                         equipment, and accessories.

                                         7.03 Positions and secures refrigeration and air cooling    01 2 345
                                         components, equipment, and accessories.

                                         7.04 Routes and connects refrigerant piping.                01 2 345

                                         7.05 Performs leak test on system.                          01 2 345

                                         7.06 Evacuates system.                                      01 2 345

                                         7.07 Charges system.                                        01 2 345




                 Task                                               Sub-Tasks                         Rating

8. Commissions refrigeration and air     8.01 Performs pre-start-up checks.                          01 2 345
cooling system.

                                         8.02 Starts up refrigeration and air conditioning system.   01 2 345

                                         8.03 Completes system charge.                               01 2 345

                                         8.04 Sets up primary and secondary refrigeration system     01 2 345
                                         adjustable switches, valves, and regulators.
                 Task                                              Sub-Tasks                            Rating

9. Maintains refrigeration and air        9.01 Inspects refrigeration and air cooling systems.         01 2 345
cooling systems.

                                          9.02 Tests electrical and electronic components.             01 2 345

                                          9.03 Tests mechanical components.                            01 2 345

                                          9.04 Recommends corrective action.                           01 2 345

                                          9.05 Selects refrigeration and air cooling equipment and     01 2 345
                                          components.

                                          9.06 Replaces defective components and equipment.            01 2 345

                                          9.07 Repairs and overhauls defective components and          01 2 345
                                          equipment.

                                          9.08 Verifies refrigeration and air cooling system and        01 2 345
                                          component function.

                                          9.09 Performs predictive maintenance.                        01 2 345

                                          9.10 Performs preventive maintenance.                        01 2 345




Block C      Heating, Ventilating, and Air Conditioning Systems (36 Questions)
                  Task                                             Sub-Tasks                            Rating

10. Plans installation of heating, ven-   10.01 Verifies heating, ventilating, and air conditioning     01 2 345
tilating, and air conditioning systems.   systems parameters and requirements.

                                          10.02 Selects heating, ventilating, and air conditioning     01 2 345
                                          components and equipment.

                                          10.03 Confirms heating, ventilating, and air conditioning     01 2 345
                                          requirements.




                  Task                                             Sub-Tasks                            Rating

11. Installs heating, ventilating, and    11.01 Prepares heating, ventilating, and air conditioning    01 2 345
air conditioning systems.                 equipment site/location.

                                          11.02 Assembles heating, ventilating, and air conditioning   01 2 345
                                          equipment.
                                      11.03 Positions and secures heating, ventilating, and air    01 2 345
                                      conditioning equipment.




                 Task                                           Sub-Tasks                           Rating

12. Commissions heating, ventilating, 12.01 Performs pre-start-up checks.                          01 2 345
and air conditioning systems.

                                      12.02 Starts up heating, ventilating, and air conditioning   01 2 345
                                      systems.




                 Task                                           Sub-Tasks                           Rating

13. Maintains heating, ventilating,   13.01 Inspects heating, ventilating, and air conditioning    01 2 345
and air conditioning systems.         systems.

                                      13.02 Tests electrical/electronic components in heating,     01 2 345
                                      ventilating, and air conditioning systems.

                                      13.03 Tests mechanical components in heating, ventilating,   01 2 345
                                      and air conditioning systems.

                                      13.04 Recommends corrective action.                          01 2 345

                                      13.05 Selects heating, ventilating, and air conditioning,    01 2 345
                                      equipment and components.

                                      13.06 Replaces defective heating, ventilating, and air       01 2 345
                                      conditioning components and equipment.

                                      13.07 Repairs/ overhauls defective components and            01 2 345
                                      equipment for heating, ventilating, and air conditioning
                                      systems.

                                      13.08 Verifies heating, ventilating, and air conditioning     01 2 345
                                      systems and components function.

                                      13.09 Performs predictive maintenance on heating             01 2 345
                                      system.

                                      13.10 Performs preventative maintenance on heating,          01 2 345
                                      ventilating, and air conditioning systems.
Block D         Control Systems (24 Questions)
                 Task                                          Sub-Tasks                        Rating

14. Plans installation of control    14.01 Selects controls.                                   01 2 345
systems.

                                     14.02 Lays out control system components and wiring.      01 2 345




                 Task                                          Sub-Tasks                        Rating

15. Installs control systems.        15.01 Prepares site/location for control system.          01 2 345

                                     15.02 Positions and secures control system components.    01 2 345

                                     15.03 Connects system wiring and tubing.                  01 2 345




                 Task                                          Sub-Tasks                        Rating

16. Commissions control systems.     16.01 Performs pre-start-up checks.                       01 2 345

                                     16.02 Sets operating parameters.                          01 2 345

                                     16.03 Starts up control system.                           01 2 345




                 Task                                          Sub-Tasks                        Rating

17. Maintains control systems.       17.01 Inspects control system.                            01 2 345

                                     17.02 Verifies and resets operating parameters.            01 2 345

                                     17.03 Tests electrical/electronic components in control   01 2 345
                                     system.

                                     17.04 Tests mechanical components in control system.      01 2 345

                                     17.05 Recommends corrective action.                       01 2 345

                                     17.06 Selects control system equipment and components.    01 2 345

                                     17.07 Replaces defective control components and equip-    01 2 345
                                     ment.

                                     17.08 Repairs/ overhauls defective components and         01 2 345
                                     equipment for control system.
                                           17.09 Verifies control system component function.                   01 2 345

                                           17.10 Performs preventative maintenance on control                 01 2 345
                                           system.

                                           17.11 Calibrates operating and safety controls.                    01 2 345



You have completed the WEF for this Red Seal trade. If you had difficulty understanding the subtasks and/or would like to
obtain a detailed break-down of the subtasks, go to www.red-seal.ca. Select a trade from the right-hand menu, then scroll
down to section Trades Information and click on the “green” button to download the National Occupational Analysis (NOA)
(if you are given a choice, select the NOA the exam is based on). How you assess yourself is an important step to prepare for
the certification exam.

For sample questions in some trades scroll down to section Additional Information and click on the Exam Counselling Sheet and
you will see the Sample Questions link in blue letters.




Name (please print) _______________________________________________________________________


Signature __________________________________________________ Date: _______________________




                                                Apprenticeship Manitoba
                                                 1010-401 York Avenue
                                                  Winnipeg MB, R3C

            (204) 945-3337 (Phone)        1-877-978-7233 (Toll Free in Manitoba)         (204) 948-2346 (Fax)

				
DOCUMENT INFO
Shared By:
Categories:
Tags:
Stats:
views:3
posted:10/10/2012
language:English
pages:8