works control form Jam
Document Sample


Housing Repair Site Visit Report
Name of Beneficiary: Date of Visit:
Address: Contact #:
Name Builder: Contact #:
Acceptable Unacceptable Comments
Check list:
Level and square up the foundations
1. foundations size: 2 ft deep / 18” wide
2. steel cage / wall bars every 16”/ height of wall bars
to calculate
3. level of concrete / level of blocks
4. thread every 32” / fix the base plate
5. compact marl / level 2” under top of block
6. lay down BRC fabric mesh / overlapping
7. slab 4” concrete 1:2:4 / smooth finish
8. corners 4 x 4 and 2 x 4 / J bolt / braces
9. studs every 2 feet (24 inches)
10. doubled studs around doors
11. joint the top plate on top of studs
12. window sill 1 x 6 / slope / weather strip
13. double the top plates
14. hurricane straps used on connecting studs to
plates ( squared at the bottom and twisted at the top)
15. Angle of Roof 30 degrees (7” high for 1 ft long)
62 “ for 18 x 24 , 42” for 12 x 12 or 12 x 18 or 12 x 24
16. ridge pole 2 x 6 / ridge beam 2 x 6
17. ridge beam jointed on top of intermediate frame
18. Rafter every 2 feet on centre (24’’)
19. Maximum Eave Overhang of 8’’
20. Hurricane straps used on connecting rafter to the
plates and ridge beam
21. plywood nailed every 8” on each rafter
22. Laths 1’’ x 3’’ / 1 foot on centre at the bottom / 2 ft
on centre
23. roofing nails every corrugations at bottom and top
24. Fascia capping / ridge cap overlapping 1 ft