cadprodatasheet

Reviews
Shared by: Guillaume
Tags
Stats
views:
40
rating:
not rated
reviews:
0
posted:
11/6/2007
language:
English
pages:
0
X-Ray Film Digitizer for Mammography CAD The VIDAR Advantage The CAD PRO Advantage® film digitizer has been specifically designed for mammography CAD. The American Cancer Society estimates the five-year relative survival rate from Stage I breast cancer at 98 percent versus just 16 percent for Stage IV breast cancer. Experts agree that routine mammography exams, when combined with mammography CAD, are the single most effective tool for detecting early signs of breast cancer. CAD systems incorporate advanced pattern recognition and image analysis capabilities designed to aid in the detection of subtle signs of breast cancer. These systems enable radiologists to improve their ability to detect early stage cancers in an efficient manner. A key component of these CAD systems is a high performance film digitizer that meets the highest standards of image quality and reliability. Understanding Marketplace Needs Unlike other manufacturers that take an evolutionary approach, VIDAR has created a revolutionary design for the CAD PRO Advantage in the important areas of image quality, film feeding and transport, and system speed. VIDAR worked closely with major CAD systems providers, mammography technologists, radiologists, engineering consultants, and quality experts to ensure that the CAD PRO Advantage meets the exacting needs of the mammography marketplace. The CAD PRO’s advanced technology will enable CAD systems providers to improve radiologists’ confidence in accurately detecting breast abnormalities. reliability and speed. In particular, film feeder reliability and speed are vital to productivity, as film feeder problems have the potential to disrupt operations, increase costs, and inconvenience patients. VIDAR, as part of its commitment to technology leadership, worked relentlessly to develop an innovative film feeder ® design. The continuous loading SmartFeeder is the anchor of the film digitizer’s reliability. The CAD PRO Advantage offers a modular 50-sheet film feeder. In addition, the advanced design of the feeder eliminates film jams, double feeds, and film pick-up problems that occur with other digitizers. Most importantly, the CAD PRO Advantage feeder is designed for continuous case loading. This feature allows the user to add cases without interrupting the digitizing process. In addition, the CAD PRO Advantage is able to digitize a four-film case in less than 120 seconds, which is 2X the speed of most other digitizers on the market, further increasing productivity. The CAD PRO’s modular design allows easy access for scheduled maintenance and field serviceable parts replacement to minimize downtime. VIDAR’s clinically proven technology and unique product designs continue to set the standard for excellence in a number of market segments, including PACS, teleradiology, telemedicine, mammography, and oncology. VIDAR’s digitizers are the choice of more than 100 systems solution providers. Technology Advantage and Innovation VIDAR has filed three patents related to the CAD PRO Advantage technology. Each of these patents applies to critical product attributes such as image quality, reliability, and system throughput. The CAD PRO Advantage offers unmatched spatial and contrast resolution, allowing radiologists to be confident that the image data the CAD system receives from the film digitizer is an exact representation of the original film. Additionally, VIDAR’s ADC™ (Automatic Digitizer Calibration) prompts the film digitizer to calibrate automatically before every film digitized; therefore, user intervention is not needed for this operation. In addition, the CAD PRO Advantage includes a closed-loop quality assurance system to help ensure the digitizer sub-system meets all MQSA requirements. This combination of technology results in virtually no variation in image quality from one digitized film to another, and ensures excellent grayscale reproduction in every image. This reproducibility, vital for mammography CAD, is another hallmark of VIDAR digitizers. Productivity and reliability will increase due to the digitizers’ exceptional reproducibility of image quality. Understanding Customer Requirements VIDAR listened to its customers with the goal of enhancing the standard of care for mammography. Key requirements for a successful digitizer include excellent image quality, film feeder Film Size 24cm x 18cm 24cm x 30cm Nominal Resolution 5K x 4K 5K x 7K Pixels 5376 x 4032 5376 x 6720 Spot Size (µm) 44 44 DPI 570 570 Line pairs per mm 11 11 Digitizing Speed 20 Seconds 33 Seconds Clinical Optical Density Range Bit Depth MTBF Film Sizes Auto Film Feeder Translation Table Geometric Accuracy Scan Rate Hardware Interface Software Power Requirements .05 to 4.2 32-bit mapped to 16-bit (65,536) or 12-bit (4,096) Grayscale Output >50,000 hours 7” x 9” x 9” x 12” (18 cm x 24 cm and 24 cm x 30 cm) Thickness: 0.006” to 0.008” ® Continuous Loading SmartFeeder — Modular with 50-film capacity (mixed sized – no presorting necessary) Linear OD Better than 1% or 2 pixels, whichever is greater, in both axes 200 lines/second (120 films per hour, 18cm x 24cm) USB 2.0 ® Windows scanning modules and Linux software development tools available Voltage: 85~264 vac Frequency: 47~63 Hz Power: <100 watts 50º to 95º F (10º to 35º C), 20% to 85% relative humidity non-condensing 0º to 140º F (-18º to 60º C), 20% to 85% relative humidity non-condensing LED Illuminator; >500,000 scans Solid-state, next-generation High Definition CCD (HD-CCD®) With Feeder & Exit Tray: 19” W x 21.25” D x 25.5” H (483mm x 540mm x 648mm) Without Feeder & Exit Tray: 19” W x 14.25” D x 12.75” H (483mm x 362mm x 324mm) Shipping: 24” W x 29” L x 24” H (610mm x 737mm x 610mm) 45 lbs. (21 kg); shipping weight: 60 lbs (27 kg) CE-MDD 93/42/EEC Class 1; CAN/CSA C22.2 No 601.1-M90; Health Canada Class II; Japan-MHW; CCC; SFDA; KFDA; FCC Class A; EN 60601-2; IEC 60601-1; IEC 60950; ISO 9001:2000; ISO 13485:2003; for FDA information, contact VIDAR. Operating Environment Storage Environment Illuminator Detector Dimensions Weight Certifications Specifications are subject to change without notice 365 Herndon Parkway Herndon, VA USA 20170 www.filmdigitizer.com Phone: Toll-free: Fax: +1.703.471.7070 1.800.471.7226 +1.703.471.7665 VIDAR, CAD PRO, SmartFeeder, and HD-CCD are registered trademarks of VIDAR Systems Corporation. ADC is a trademark of VIDAR Systems Corporation. All other product names are registered marks of their respective parent companies. VIDAR Publication PN 15790-001 Rev F, May 2007

Other docs by Guillaume
YouTube-039-s-Official-Authorities-The-Users-70079
Views: 1661  |  Downloads: 12
YouTube-Fights-Against-Its-Father-Google-55082
Views: 1389  |  Downloads: 11
xna_launch_final_report
Views: 1353  |  Downloads: 5
XNA_Introduction
Views: 1093  |  Downloads: 11
xna
Views: 1024  |  Downloads: 4
XNA Development-1
Views: 1841  |  Downloads: 10
xmas_05
Views: 968  |  Downloads: 0
xerc_users_manual
Views: 1079  |  Downloads: 1
xbst
Views: 1019  |  Downloads: 0
Xbox Way
Views: 1086  |  Downloads: 0
XboxVGA Video Setup
Views: 550  |  Downloads: 0
xbox-router
Views: 367  |  Downloads: 0
xboxnext_security
Views: 241  |  Downloads: 2
XBoxMACAddress
Views: 910  |  Downloads: 0