TYPICAL SPECIFICATION by 77iis9

VIEWS: 1 PAGES: 2

									             Lonsdale QuikSpec 2
Heated Spaces – rooflights, atriums, conservatories, swimming pool enclosures or skylights
fixing to supporting members by others

Actions by the Specifier are shown in RED


Patent Glazing                 Enter your project reference

Drawing References             Enter your drawing numbers

Supporting structure           Prepared steel / timber supports (delete accordingly)

Patent Glazing System          To BS5516, and as specified in this section

Manufacturer & reference Lonsdale Metal Co Ltd., London N17 9QU
                         Tel +44(0)20 8801 4221 Fax +44(0)20 8801 1287
                         info@lonsdalemetal.co.uk Reference THERMGARD
                         series patent glazing system

Type                           Extruded aluminium thermally broken box-bar featuring
                               internally ventilated box-section with continuous external
                               pressure plates, gasketry and snap on covers.

Glazing Bar :
Material                       Aluminium alloy 6063-T6 to BS1474
Finish                         Standard RAL Matt Finish (or delete & insert mill finish)
Colour                         Insert RAL number or insert ‘N/A’ if mill finish
Minimum Film thickness         40 microns (or delete & insert ‘N/A’ if mill finish)
Spacing                        Nominally 600mm c/c (if wider than 750mm contact our
                               Technical dept.)
Slope                          Minimum 15 degrees (or insert actual pitch if known)
Bottom overhang lap            Nom 75mm

Pane/infilling materials       Please select from following options:


                               Standard:-
                               6.4mm clear laminated low-e glass inner pane, 16mm argon
                               cavity and 6mm clear toughened outer pane with stepped
                               bottom edge. Centre pane Uvalue should not be worse than
                               1.5W/m2.k


                               Premium:-
                               6.4mm clear laminated soft coat low-e glass inner pane,
                               16mm argon cavity and 6mm blue toughened self-cleaning
                               glass with stepped bottom edge. Centre pane Uvalue should
                                    not be worse than 1.2W/m2.k and should reduce solar heat
                                    gain.

                                     (please contact us for other glass specifications including
                                    single glazing or polycarbonate more suitable for your
                                    project)


Incorporated components Please select from following options:

                                    None

                                    OR

                                    GlazaTherm Top Hung Opening Rooflights with factory fitted
                                    pole, cord or electric motors (delete accordingly)

    *if you require to add access panels, photo-voltaics, cladding, or solar thermal panels,
    please contact our technical department

Please note : whilst we are pleased to assist, the above example is given for guidance only. Responsibility
remains with the specifier to ensure our products are fit for the intended purpose and comply with all local
building regulations and required standards

								