Coriolis DIN11851 24V Profibus by eYhL5doH

VIEWS: 0 PAGES: 8

									CORIOLIS – DIN 11851 DN 10 – 24 V – PROFIBUS PA

Coriolis flow meter for exact flow measurement and dosing of liquids and gases
of all kind. Sensor with high dynamic for precise flow, density, mass and
temperature measurement, accuracy/error typically less than 0,1 % of actual
flow, density error typically less than 0,0015 g/ccm With SENSORPROM-
technology for easy commissioning and permanent storage of all process and
device parameters. Single continuous tube design, without internal welds,
reductions or flow splitters, low pressure drop, wide dynamic range 500 : 1,
capacity up to 1000 kg/h, process temperature -50 to +180 °C, inside pipe
diameter DI 6, process connection thread DIN 11851 DN 10 PN 25, sensor
material AISI 316L, approval ATEX II 1G EEx ia. Compact with digital
Coriolis transmitter with diagnostics and service menu and add-on bus modules,
retrofittable on site. 3 line LCD display for mass flow, total flow, error
messages. Ambient temperature –20 to +50 °C. Frequency/pulse output, digital
input (batch control, totalizer reset or zero point adjustment), relay output
(error, limit, flow direction or empty pipe detection), galvanically isolated and
to be configured individually. Communication 4 – 20 mA, Profibus PA. Power
supply 20 30 V DC, polyamid housing, enclosure IP 67, delivery and
installation.

Make:                                                Siemens or equivalent
Type:                                  SITRANS F C MASS 2100/MASS 6000


CORIOLIS – DIN 11851 DN 10 – 24 V – PROFIBUS PA - ATEX

Coriolis flow meter for exact flow measurement and dosing of liquids and gases
of all kind. Sensor with high dynamic for precise flow, density, mass and
temperature measurement, accuracy/error typically less than 0,1 % of actual
flow, density error typically less than 0,0015 g/ccm With SENSORPROM-
technology for easy commissioning and permanent storage of all process and
device parameters. Single continuous tube design, without internal welds,
reductions or flow splitters, low pressure drop, wide dynamic range 500 : 1,
capacity up to 1000 kg/h, process temperature -50 to +180 °C, inside pipe
diameter DI 6, process connection thread DIN 11851 DN 10 PN 25, sensor
material AISI 316L, approval ATEX II 1G EEx ia. Compact with digital
Coriolis transmitter with diagnostics and service menu and add-on bus modules,
retrofittable on site. 3 line LCD display for mass flow, total flow, error
messages. Ambient temperature –20 to +50 °C. Frequency/pulse output, digital
input (batch control, totalizer reset or zero point adjustment), relay output
(error, limit, flow direction or empty pipe detection), galvanically isolated and
to be configured individually. Communication 4 – 20 mA, Profibus PA. Power
supply 20 – 30 V AC/DC, approval ATEX II 2G EEx d e (ia/ib), stainless steel
enclosure, delivery and installation.

Make:                                                Siemens or equivalent
Type:                                  SITRANS F C MASS 2100/MASS 6000


CORIOLIS – DIN 11851 DN 10 – 24 V – PROFIBUS DP
Coriolis flow meter for exact flow measurement and dosing of liquids and gases
of all kind. Sensor with high dynamic for precise flow, density, mass and
temperature measurement, accuracy/error typically less than 0,1 % of actual
flow, density error typically less than 0,0015 g/ccm With SENSORPROM-
technology for easy commissioning and permanent storage of all process and
device parameters. Single continuous tube design, without internal welds,
reductions or flow splitters, low pressure drop, wide dynamic range 500 : 1,
capacity up to 1000 kg/h, process temperature -50 to +180 °C, inside pipe
diameter DI 6, process connection thread DIN 11851 DN 10 PN 40, sensor
material AISI 316L, approval ATEX II 1G EEx ia. Compact with digital
Coriolis transmitter with diagnostics and service menu and add-on bus modules,
retrofittable on site. 3 line LCD display for mass flow, total flow, error
messages. Ambient temperature –20 to +50 °C. Frequency/pulse output, digital
input (batch control, totalizer reset or zero point adjustment), relay output
(error, limit, flow direction or empty pipe detection), galvanically isolated and
to be configured individually. Communication Profibus DP. Power supply 20
30 V DC, polyamid housing, enclosure IP 67, delivery and installation.

Make:                                                Siemens or equivalent
Type:                                  SITRANS F C MASS 2100/MASS 6000


CORIOLIS – DIN 11851 DN 15 – 24 V – PROFIBUS PA

Coriolis flow meter for exact flow measurement and dosing of liquids and gases
of all kind. Sensor with high dynamic for precise flow, density, mass and
temperature measurement, accuracy/error typically less than 0,1 % of actual
flow, density error typically less than 0,0015 g/ccm With SENSORPROM-
technology for easy commissioning and permanent storage of all process and
device parameters. Single continuous tube design, without internal welds,
reductions or flow splitters, low pressure drop, wide dynamic range 500 : 1,
capacity up to 5600 kg/h, process temperature -50 to +180 °C, inside pipe
diameter DI 15, process connection thread DIN 11851 DN 15 PN 25, sensor
material AISI 316L, approval ATEX II 1G EEx ia. Compact with digital
Coriolis transmitter with diagnostics and service menu and add-on bus modules,
retrofittable on site. 3 line LCD display for mass flow, total flow, error
messages. Ambient temperature –20 to +50 °C. Frequency/pulse output, digital
input (batch control, totalizer reset or zero point adjustment), relay output
(error, limit, flow direction or empty pipe detection), galvanically isolated and
to be configured individually. Communication 4 – 20 mA, Profibus PA. Power
supply 20 30 V DC, polyamid housing, enclosure IP 67, delivery and
installation.

Make:                                                Siemens or equivalent
Type:                                  SITRANS F C MASS 2100/MASS 6000


CORIOLIS – DIN 11851 DN 15 – 24 V – PROFIBUS PA - ATEX

Coriolis flow meter for exact flow measurement and dosing of liquids and gases
of all kind. Sensor with high dynamic for precise flow, density, mass and
temperature measurement, accuracy/error typically less than 0,1 % of actual
flow, density error typically less than 0,0015 g/ccm With SENSORPROM-
technology for easy commissioning and permanent storage of all process and
device parameters. Single continuous tube design, without internal welds,
reductions or flow splitters, low pressure drop, wide dynamic range 500 : 1,
capacity up to 5600 kg/h, process temperature -50 to +180 °C, inside pipe
diameter DI 15, process connection thread DIN 11851 DN 15 PN 25, sensor
material AISI 316L, approval ATEX II 1G EEx ia. Compact with digital
Coriolis transmitter with diagnostics and service menu and add-on bus modules,
retrofittable on site. 3 line LCD display for mass flow, total flow, error
messages. Ambient temperature –20 to +50 °C. Frequency/pulse output, digital
input (batch control, totalizer reset or zero point adjustment), relay output
(error, limit, flow direction or empty pipe detection), galvanically isolated and
to be configured individually. Communication 4 – 20 mA, Profibus PA. Power
supply 20 – 30 V AC/DC, approval ATEX II 2G EEx d e (ia/ib), stainless steel
enclosure, delivery and installation.

Make:                                                Siemens or equivalent
Type:                                  SITRANS F C MASS 2100/MASS 6000


CORIOLIS – DIN 11851 DN 15 – 24 V – PROFIBUS DP

Coriolis flow meter for exact flow measurement and dosing of liquids and gases
of all kind. Sensor with high dynamic for precise flow, density, mass and
temperature measurement, accuracy/error typically less than 0,1 % of actual
flow, density error typically less than 0,0015 g/ccm With SENSORPROM-
technology for easy commissioning and permanent storage of all process and
device parameters. Single continuous tube design, without internal welds,
reductions or flow splitters, low pressure drop, wide dynamic range 500 : 1,
capacity up to 5600 kg/h, process temperature -50 to +180 °C, inside pipe
diameter DI 15, process connection thread DIN 11851 DN 15 PN 40, sensor
material AISI 316L, approval ATEX II 1G EEx ia. Compact with digital
Coriolis transmitter with diagnostics and service menu and add-on bus modules,
retrofittable on site. 3 line LCD display for mass flow, total flow, error
messages. Ambient temperature –20 to +50 °C. Frequency/pulse output, digital
input (batch control, totalizer reset or zero point adjustment), relay output
(error, limit, flow direction or empty pipe detection), galvanically isolated and
to be configured individually. Communication Profibus DP. Power supply 20
30 V DC, polyamid housing, enclosure IP 67, delivery and installation.

Make:                                                Siemens or equivalent
Type:                                  SITRANS F C MASS 2100/MASS 6000


CORIOLIS – DIN 11851 DN 25 – 24 V – PROFIBUS PA

Coriolis flow meter for exact flow measurement and dosing of liquids and gases
of all kind. Sensor with high dynamic for precise flow, density, mass and
temperature measurement, accuracy/error typically less than 0,1 % of actual
flow, density error typically less than 0,0015 g/ccm With SENSORPROM-
technology for easy commissioning and permanent storage of all process and
device parameters. Single continuous tube design, without internal welds,
reductions or flow splitters, low pressure drop, wide dynamic range 500 : 1,
capacity up to 25000 kg/h, process temperature -50 to +180 °C, inside pipe
diameter DI 25, process connection thread DIN 11851 DN 25 PN 25, sensor
material AISI 316L, approval ATEX II 1G EEx ia. Compact with digital
Coriolis transmitter with diagnostics and service menu and add-on bus modules,
retrofittable on site. 3 line LCD display for mass flow, total flow, error
messages. Ambient temperature –20 to +50 °C. Frequency/pulse output, digital
input (batch control, totalizer reset or zero point adjustment), relay output
(error, limit, flow direction or empty pipe detection), galvanically isolated and
to be configured individually. Communication 4 – 20 mA, Profibus PA. Power
supply 20 30 V DC, polyamid housing, enclosure IP 67, delivery and
installation.

Make:                                                Siemens or equivalent
Type:                                  SITRANS F C MASS 2100/MASS 6000


CORIOLIS – DIN 11851 DN 25 – 24 V – PROFIBUS PA - ATEX

Coriolis flow meter for exact flow measurement and dosing of liquids and gases
of all kind. Sensor with high dynamic for precise flow, density, mass and
temperature measurement, accuracy/error typically less than 0,1 % of actual
flow, density error typically less than 0,0015 g/ccm With SENSORPROM-
technology for easy commissioning and permanent storage of all process and
device parameters. Single continuous tube design, without internal welds,
reductions or flow splitters, low pressure drop, wide dynamic range 500 : 1,
capacity up to 25000 kg/h, process temperature -50 to +180 °C, inside pipe
diameter DI 25, process connection thread DIN 11851 DN 25 PN 25, sensor
material AISI 316L, approval ATEX II 1G EEx ia. Compact with digital
Coriolis transmitter with diagnostics and service menu and add-on bus modules,
retrofittable on site. 3 line LCD display for mass flow, total flow, error
messages. Ambient temperature –20 to +50 °C. Frequency/pulse output, digital
input (batch control, totalizer reset or zero point adjustment), relay output
(error, limit, flow direction or empty pipe detection), galvanically isolated and
to be configured individually. Communication 4 – 20 mA, Profibus PA. Power
supply 20 – 30 V AC/DC, approval ATEX II 2G EEx d e (ia/ib), stainless steel
enclosure, delivery and installation.

Make:                                                Siemens or equivalent
Type:                                  SITRANS F C MASS 2100/MASS 6000


CORIOLIS – DIN 11851 DN 25 – 24 V – PROFIBUS DP

Coriolis flow meter for exact flow measurement and dosing of liquids and gases
of all kind. Sensor with high dynamic for precise flow, density, mass and
temperature measurement, accuracy/error typically less than 0,1 % of actual
flow, density error typically less than 0,0015 g/ccm With SENSORPROM-
technology for easy commissioning and permanent storage of all process and
device parameters. Single continuous tube design, without internal welds,
reductions or flow splitters, low pressure drop, wide dynamic range 500 : 1,
capacity up to 25000 kg/h, process temperature -50 to +180 °C, inside pipe
diameter DI 25, process connection thread DIN 11851 DN 25 PN 40, sensor
material AISI 316L, approval ATEX II 1G EEx ia. Compact with digital
Coriolis transmitter with diagnostics and service menu and add-on bus modules,
retrofittable on site. 3 line LCD display for mass flow, total flow, error
messages. Ambient temperature –20 to +50 °C. Frequency/pulse output, digital
input (batch control, totalizer reset or zero point adjustment), relay output
(error, limit, flow direction or empty pipe detection), galvanically isolated and
to be configured individually. Communication Profibus DP. Power supply 20
30 V DC, polyamid housing, enclosure IP 67, delivery and installation.

Make:                                                Siemens or equivalent
Type:                                  SITRANS F C MASS 2100/MASS 6000


CORIOLIS – DIN 11851 DN 40 – 24 V – PROFIBUS PA

Coriolis flow meter for exact flow measurement and dosing of liquids and gases
of all kind. Sensor with high dynamic for precise flow, density, mass and
temperature measurement, accuracy/error typically less than 0,1 % of actual
flow, density error typically less than 0,0015 g/ccm With SENSORPROM-
technology for easy commissioning and permanent storage of all process and
device parameters. Single continuous tube design, without internal welds,
reductions or flow splitters, low pressure drop, wide dynamic range 500 : 1,
capacity up to 52000 kg/h, process temperature -50 to +180 °C, inside pipe
diameter DI 40, process connection thread DIN 11851 DN 40 PN 25, sensor
material AISI 316L, approval ATEX II 1G EEx ia. Compact with digital
Coriolis transmitter with diagnostics and service menu and add-on bus modules,
retrofittable on site. 3 line LCD display for mass flow, total flow, error
messages. Ambient temperature –20 to +50 °C. Frequency/pulse output, digital
input (batch control, totalizer reset or zero point adjustment), relay output
(error, limit, flow direction or empty pipe detection), galvanically isolated and
to be configured individually. Communication 4 – 20 mA, Profibus PA. Power
supply 20 30 V DC, polyamid housing, enclosure IP 67, delivery and
installation.

Make:                                                Siemens or equivalent
Type:                                  SITRANS F C MASS 2100/MASS 6000


CORIOLIS – DIN 11851 DN 40 – 24 V – PROFIBUS PA - ATEX

Coriolis flow meter for exact flow measurement and dosing of liquids and gases
of all kind. Sensor with high dynamic for precise flow, density, mass and
temperature measurement, accuracy/error typically less than 0,1 % of actual
flow, density error typically less than 0,0015 g/ccm With SENSORPROM-
technology for easy commissioning and permanent storage of all process and
device parameters. Single continuous tube design, without internal welds,
reductions or flow splitters, low pressure drop, wide dynamic range 500 : 1,
capacity up to 52000 kg/h, process temperature -50 to +180 °C, inside pipe
diameter DI 40, process connection thread DIN 11851 DN 40 PN 25, sensor
material AISI 316L, approval ATEX II 1G EEx ia. Compact with digital
Coriolis transmitter with diagnostics and service menu and add-on bus modules,
retrofittable on site. 3 line LCD display for mass flow, total flow, error
messages. Ambient temperature –20 to +50 °C. Frequency/pulse output, digital
input (batch control, totalizer reset or zero point adjustment), relay output
(error, limit, flow direction or empty pipe detection), galvanically isolated and
to be configured individually. Communication 4 – 20 mA, Profibus PA. Power
supply 20 – 30 V AC/DC, approval ATEX II 2G EEx d e (ia/ib), stainless steel
enclosure, delivery and installation.

Make:                                                Siemens or equivalent
Type:                                  SITRANS F C MASS 2100/MASS 6000


CORIOLIS – DIN 11851 DN 40 – 24 V – PROFIBUS DP

Coriolis flow meter for exact flow measurement and dosing of liquids and gases
of all kind. Sensor with high dynamic for precise flow, density, mass and
temperature measurement, accuracy/error typically less than 0,1 % of actual
flow, density error typically less than 0,0015 g/ccm With SENSORPROM-
technology for easy commissioning and permanent storage of all process and
device parameters. Single continuous tube design, without internal welds,
reductions or flow splitters, low pressure drop, wide dynamic range 500 : 1,
capacity up to 52000 kg/h, process temperature -50 to +180 °C, inside pipe
diameter DI 40, process connection thread DIN 11851 DN 40 PN 40, sensor
material AISI 316L, approval ATEX II 1G EEx ia. Compact with digital
Coriolis transmitter with diagnostics and service menu and add-on bus modules,
retrofittable on site. 3 line LCD display for mass flow, total flow, error
messages. Ambient temperature –20 to +50 °C. Frequency/pulse output, digital
input (batch control, totalizer reset or zero point adjustment), relay output
(error, limit, flow direction or empty pipe detection), galvanically isolated and
to be configured individually. Communication Profibus DP. Power supply 20
30 V DC, polyamid housing, enclosure IP 67, delivery and installation.

Make:                                                Siemens or equivalent
Type:                                  SITRANS F C MASS 2100/MASS 6000


CORIOLIS – DIN 11851 DN 50 – 24 V – PROFIBUS PA

Coriolis flow meter for exact flow measurement and dosing of liquids and gases
of all kind. Sensor with high dynamic for precise flow, density, mass and
temperature measurement, accuracy/error typically less than 0,1 % of actual
flow, density error typically less than 0,0015 g/ccm With SENSORPROM-
technology for easy commissioning and permanent storage of all process and
device parameters. Single continuous tube design, without internal welds,
reductions or flow splitters, low pressure drop, wide dynamic range 500 : 1,
capacity up to 52000 kg/h, process temperature -50 to +180 °C, inside pipe
diameter DI 40, process connection thread DIN 11851 DN 50 PN 25, sensor
material AISI 316L, approval ATEX II 1G EEx ia. Compact with digital
Coriolis transmitter with diagnostics and service menu and add-on bus modules,
retrofittable on site. 3 line LCD display for mass flow, total flow, error
messages. Ambient temperature –20 to +50 °C. Frequency/pulse output, digital
input (batch control, totalizer reset or zero point adjustment), relay output
(error, limit, flow direction or empty pipe detection), galvanically isolated and
to be configured individually. Communication 4 – 20 mA, Profibus PA. Power
supply 20 30 V DC, polyamid housing, enclosure IP 67, delivery and
installation.

Make:                                                Siemens or equivalent
Type:                                  SITRANS F C MASS 2100/MASS 6000


CORIOLIS – DIN 11851 DN 50 – 24 V – PROFIBUS PA - ATEX

Coriolis flow meter for exact flow measurement and dosing of liquids and gases
of all kind. Sensor with high dynamic for precise flow, density, mass and
temperature measurement, accuracy/error typically less than 0,1 % of actual
flow, density error typically less than 0,0015 g/ccm With SENSORPROM-
technology for easy commissioning and permanent storage of all process and
device parameters. Single continuous tube design, without internal welds,
reductions or flow splitters, low pressure drop, wide dynamic range 500 : 1,
capacity up to 52000 kg/h, process temperature -50 to +180 °C, inside pipe
diameter DI 40, process connection thread DIN 11851 DN 50 PN 25, sensor
material AISI 316L, approval ATEX II 1G EEx ia. Compact with digital
Coriolis transmitter with diagnostics and service menu and add-on bus modules,
retrofittable on site. 3 line LCD display for mass flow, total flow, error
messages. Ambient temperature –20 to +50 °C. Frequency/pulse output, digital
input (batch control, totalizer reset or zero point adjustment), relay output
(error, limit, flow direction or empty pipe detection), galvanically isolated and
to be configured individually. Communication 4 – 20 mA, Profibus PA. Power
supply 20 – 30 V AC/DC, approval ATEX II 2G EEx d e (ia/ib), stainless steel
enclosure, delivery and installation.

Make:                                                Siemens or equivalent
Type:                                  SITRANS F C MASS 2100/MASS 6000


CORIOLIS – DIN 11851 DN 50 – 24 V – PROFIBUS DP

Coriolis flow meter for exact flow measurement and dosing of liquids and gases
of all kind. Sensor with high dynamic for precise flow, density, mass and
temperature measurement, accuracy/error typically less than 0,1 % of actual
flow, density error typically less than 0,0015 g/ccm With SENSORPROM-
technology for easy commissioning and permanent storage of all process and
device parameters. Single continuous tube design, without internal welds,
reductions or flow splitters, low pressure drop, wide dynamic range 500 : 1,
capacity up to 52000 kg/h, process temperature -50 to +180 °C, inside pipe
diameter DI 40, process connection thread DIN 11851 DN 50 PN 40, sensor
material AISI 316L, approval ATEX II 1G EEx ia. Compact with digital
Coriolis transmitter with diagnostics and service menu and add-on bus modules,
retrofittable on site. 3 line LCD display for mass flow, total flow, error
messages. Ambient temperature –20 to +50 °C. Frequency/pulse output, digital
input (batch control, totalizer reset or zero point adjustment), relay output
(error, limit, flow direction or empty pipe detection), galvanically isolated and
to be configured individually. Communication Profibus DP. Power supply 20
30 V DC, polyamid housing, enclosure IP 67, delivery and installation.

Make:                                                Siemens or equivalent
Type:                                  SITRANS F C MASS 2100/MASS 6000

								
To top