									 MINIMUM   WIDTH OF AN EXIT DOOR
 MINIMUM   FLOOR TO CEILING HEIGHT
 MAXIMUM   STAIR RISE FOR CLASS A STAIR
 MAXIMUM HEIGHTS BETWEEN LANDINGS FOR
 A CLASS A STAIR
 MINIMUM   HEADROOM FOR CLASS A AND B
 STAIRS.
 UNITAREA PER PERSON FOR WAITING AREAS
 OR STANDING ROOM
 NUMBER OF EXITS FOR PLACE OF ASSEMBLY
 FOR 1000 OCCPANTS
 TRAVELDISTANCE TO AN EXIT WITHOUT FIRE
 SPRINKLER SYSTEM
 TRAVELDISTANCE TO AN EXIT WITH FIRE
 SPRINKLER SYSTEM
 MINIMUM SPACING OF ROWS OF SEATS FROM
 BACK TO BACK FOR A PUBLIC ASSEMBLY
 BUILDING
 MAXIMUMNUMBER OF SEATS IN A ROW
 BETWEEN AISLES
 MAXIMUMNUMBER OF SEATS IN A ROW
 OPENING TO AN AISLE ON ONE SIDE
 STANDARD WIDTH OF A SEAT WITHOUT
 DIVIDING ARMS FOR PLACES OF ASSEMBLY
        WIDTH OF AN AISLE SERVING AN
 MINIMUM
 OCCUPANT LOAD OF 60
 MINIMUMHEADROOM CREATED BY ANY
 PROJECTION FROM THE CEILING
 MINIMUM   CLEAR WIDTH OF TURNSTILES
 MINIMUM DIRECTION WIDTH OF LANDINGS IN
 THE DIRECTION OF TRAVEL FOR CLASS A AND
 B STAIRS.
 MINIMUMNUMBER OF RISERS IN ANY ONE
 FLIGHT OF STAIRS.
 MINIMUMHEIGHT OF A HANDRAIL ABOVE THE
 UPPER SURFACE OF THE TREAD
 MINIMUMCLEARANCE OF A HANDRAIL FROM
 ANY WALL
 MINIMUM   HEIGHT OF A GUARDRAIL
 MAXIMUM   HEIGHT OF A GUARDRAIL
 MINIMUM   INNER RADIUS OF A MONUMENTAL
 STAIR
 MINIMUM   WIDTH OF ANY BALCONY OR
 BRIDGE.
 MINIMUM   WIDTH OF ANY CLASS A RAMP.
 MAXIMUMRISE OF ANY FLOOR FROM THE
 BALCONY TO WHICH AN ACCESS DOOR LEADS.
 MAXIMUMVERTICAL HEIGHT IN FLOORS OF AN
 ESCALATOR.
 MINIMUM WIDTH OF A FIRE ESCAPE STAIR FOR
 EXISTING STAIRS.
 MINIMUMWIDTH OF A LANDING FOR A FIRE
 ESCAPE STAIR FOR EXISTING STAIRS
 MINIMUMTREAD FOR FIRE ESCAPE STAIR OF A
 SMALL BUILDING
MAXIMUM RISE FOR FIRE ESCAPE STAIR OF A
 SMALL BUILDING
MAXIMUM RISE FOR FIRE ESCAPE STAIR OF
 EXISTING STAIRS
MAXIMUM RISE FOR FIRE ESCAPE STAIR OF
 EXISTING STAIRS
MAXIMUM HEIGHT BETWEEN LANDINGS OF A
 FIRE ESCAPE STAIR FOR EXISTING STAIRS.
MINIMUM HEADROOM CLEARANCE FOR FIRE
 ESCAPE STAIRS FOR EXISTING STAIRS.
MINIMUM HEADROOM CLEARANCE FOR FIRE
 ESCAPE STAIRS FOR SMALL BUILDINGS
NUMBER OF EXITS FOR PLACE OF ASSEMBLY FOR
 600-1000 OCCUPANTS
MAXIMUM OCCUPANT LOAD FOR CLASS C
 PUBLIC ASSEMBLY
MINIMUM NUMBER OF EXITS FOR AN
 INSTITUTIONAL TYPE OF STRUCTURE
MAXIMUM TRAVEL DISTANCE BETWEEN ROOM
 DOOR INTENDED AS EXIT ACCESS AND EXIT
 WITH SPRINKLER SYSTEM FOR INSTITUTIONAL
 USE.
MAXIMUM TRAVEL DISTANCE FROM DOOR OF
 ANY ROOM TO EXIT FOR HOTELS WITH
 SPRINKLER
MAXIMUM TRAVEL DISTANCE FROM MAIN
 ENTRANCE DOOR TO EXIT FOR APARTMENTS
 WITH SPRINKLER
MAXIMUM INCREASE IN WIDTH FOR AN AISLE
 PER LINEAR METER
MINIMUM WIDTH OF AN AISLE SERVING AN
 OCCUPANT OF 60 OR MORE SERVING ONE SIDE
 OF A PUBLIC ASSEMBLY BUILDING
MINIMUM WIDTH OF AN AISLE SERVING AN
 OCCUPANT OF 60 OR MORE SERVING TWO
 SIDES OF A PUBLIC ASSEMBLY BUILDING
MINIMUM WIDTH OF AN AISLE SERVING AN
 OCCUPANT OF BELOW 60 FOR A PUBLIC
 ASSEMBLY BUILDING
MINIMUM WIDTH OF AN AISLE FOR AN
 EDUCATIONAL USE BUILDING
MINIMUM WIDTH OF AN AISLE FOR HOSPITALS
 OR NURSING HOMES.
MINIMUM WIDTH OF AN AISLE FOR CUSTODIAL
 CARE INSTITUTIONS.
MINIMUM WIDTH OF AN AISLE FOR BUSINESS
 USE STRUCTURE
MINIMUM WIDTH OF AN AISLE FOR AN
 INDUSTRIAL BUILDING
OCCUPANT LOAD PER PERSON FOR
 LABORATORIES
JAILS ARE CLASSIFIED UNDER WHAT TYPE OF
  OCCUPANCY?
COURTROOMS WITH AN OCCUPANT LOAD OF
 MORE THAN 100 ARE CLASSIFIED UNDER
 WHAT CLASSIFICATION OF OCCUPANY?
ARMORIES WITH AN OCCUPANT LOAD OF MORE
 THAN 100 ARE CLASSIFIED UNDER WHAT
 CLASSIFICATION OF OCCUPANCY?
LIBRARIES ARE CLASSIFIED UNDER WHAT
  CLASSIFICATION OF OCCUPANCY?
ROOMS WHERE BALED, BUNDLED OR PILED
 MATERIALS SEGREGATED INTO DESIRED SIZES
 OR GROUPS
BUILDINGS OR STRUCTURES WHICH ARE 15
 METERS OR MORE IN HEIGHT?
BUILDINGS OR STRUCTURES USED FOR
 STORAGE OF EXPLOSIVES, SHELLS,
 PROJECTILE, ETC.
AN AIR COMPARTMENT OR CHAMBER TO WHICH
 ONE OR MORE DUCTS ARE CONNECTED AND
 WHICH FORM PART OF AN AIR DISTRIBUTION
 SYSTEM
A KIND OF STABLE EXPLOSIVE WHICH EXPLODES
  BY PERCUSSION
DESCRIPTIVE OF ANY MATERIAL THAT INSTANTLY
 IGNITES WHEN EXPOSED TO AIR
MATERIAL THAT READILY YEALDS OXYGEN IN
 QUANTITIES SUFFICIENT TO STIMULATE OR
 SUPPORT COMBUSTION
A PROCESS WHERE A PIECE OF METAL IS HEATED
  PRIOR TO CHANGING ITS SHAPE AND
  DIMENSION
THE PROCESS OF FIRST RAISING THE
 TEMPERATURE TO SEPARATE THE MORE
 VOLATILE FROM THE LESS VOLATILE PARTS
 AND THEN COOLING AND CONDENSING THE
 RESULT VAPOR AS TO PRODUCE A NEARLY
 PURIFIED SUBSTANCE.
A FINELY POWDERED SUBSTANCE WHICH WHEN
  MIXED WITH AIR IN THE PROPER PROPORTION
  AND IGNITED WILL CAUSE AN EXPLOSION
TEMPERATURE RATING AT FLASH POINT
CLASS OF FIRE WITH FLAMMABLE LIQUID AND
 GASSES
TEMPERATURE AT WHICH LIQUID IS
 TRANSFORMED INTO VAPOR
MINIMUM FIRE RESISTANCE RATING FOR FIRE
 WALL
CONTINUOUS PASSAGEWAY FOR THE
 TRANSMISSION OF AIR
MINIMUM TEMPERATURE AT WHICH MATERIAL
 GIVES OFF VAPOR IN SUFFICIENT
 CONCENTRATION TO FORM AN IGNITABLE
 MIXTURE WITH AIR
A GAS, FUME OR VAPOR USED FOR THE
  DESTRUCTION OR THE CONTROL OF INSECTS,
  FUNGI, VERMIN, GERMS, RODENTS OR OTHER
  PESTS.
MINIMUM WIDTH OF ANY DRIVEWAY IN AND
 AROUND A LUMBER YARD/ PILES
MINIMUM HEIGHT OF FENCE FOR A LUMBER
 YARD FOR EXTERIOR STORAGE OF LUMBER
MAXIMUM WIDTH OF SUMPS FOR THE
 RETENTION OF OIL AND PETROLIUM
 PRODUCTS. FOR REFINERIES, DISTILLERIES,
 AND CHEMICAL PLANTS, MINIMUM HEIHT OF
 FENCE
MINIMUM TRAVEL DISTANCE FROM ANY
 INDIVIDUAL ROOM SUBJECT TO OCCUPANCY
 BY NOT MORE THAN 6 PERSONS
MAXIMUM DISTANCE OF TRAVEL FROM THE HIGH
 HAZARD AREA TO AN EXIT.
MINIMUM DISTANCE OF AN INCINERATOR FROM
 ANY STRUCTURE USED OTHER THAN A SINGLE
 FAMILY DWELLING.
MAXIMUM REDUCTION OF WIDTH OF A STAIR BY
 A HANDRAIL.
MINIMUM WIDTH OF A SINGLE DOOR IN A
 DOORWAY
MAXIMUM CHANGE IN ELEVATION BETWEEN THE
 INTERIOR OF A DOOR TO THE OUTSIDE IF ITS
 OTHER THAN A BALCONY
MAXIMUM FORCE IN KILOGRAMS REQUIRED FOR
 A PANIC HARDWARE
MAXIMUM HEIGHT REQUIRED FOR A PANIC
 HARDWARE
MINIMUM HEIGHT REQUIRED FOR A PANIC
 HARDWARE
MAXIMUM NUMBER OF OCCUPANTS FOR A
 SUBDIVIDED ROOM OR SPACE BY A FOLDING
 PARTITION
MINIMUM WIDTH OF A DOOR FOR FAMILY
 DAYCARE HOMES
MINIMUM STAIR WIDTH FOR CLASS B STAIRS
 HAVING AN OCCUPANT LOAD OF MORE THAN
 50 OCCUPANTS
IN EXIT HALLWAYS THE WIDTH OF A HALLWAY
  SHOULD NOT BE REDUCED BY MORE THAN
  _________ CONSIDERING AN OPENED DOOR
LENGTH OF NOSING OR EFFECTIVE PROJECTION
  OVER THE LEVEL IMMEDIETLY BELOW IT FOR
  TREAD BELOW 25 CM IN DIMENSION
MAXIMUM HEIGHT OF HANDRAIL
COMBUSTIBLE LIQUIDS ARE LIQUIDS HAVING A
 FLASH POINT OF OR ABOVE
THE TIME DURATION THAT A MATERIAL OR
 CONSTRUCTION CAN WITHSTAND THE EFFECT
 OF STANDARD FIRE TEST IS KNOWN AS…
ANY MATERIAL WHICH BY ITS NATURE OR AS A
 RESULT OF ITS REACTION WITH THE OTHER
 ELEMENTS PRODUCES A RAPID DROP IN
 TEMPERATURE OF THE IMMEDIATE
 SURROUNDING.
THE TRAVEL DISTANCE TO EXITS SHALL BE FOR
 MERCANTILE OCCUPANCIES.
UNDER WHAT CLASSIFICATION OF OCCUPANCY
 DOES POOL ROOMS FALL
UNDER WHAT CLASSIFICATION OF OCCUPANCY
 DOES HOME FOR THE AGED FALL?
UNDER WHAT CLASSIFICATION OF OCCUPANCY
 DOES COURT HOUSES FALL?
UNDER WHAT CLASSIFICATION OF OCCUPANCY
 DOES REFINERIES FALL?
UNDER WHAT CLASSIFICATION OF OCCUPANCY
 DOES DRUGSTORES FALL?
MINIMUM WIDTH OF AN AISLE FOR MERCANTILE
 OCCUPANCIES?
MINIMUM NUMBER OF AISLES FOR CLASS A
 STORES?
MINIMUM CLEAR WIDTH OF AISLES FOR CLASS A
 STORES?
MINIMUM CLEAR WIDTH OF EXITS THROUGH A
 COVERED MALL?
MINIMUM HEIGHT OF BUILDINGS REQUIRING
 AUTOMATIC SPRINKLER PROTECTION?
STANDARD INNER RADIUS OF A CURVED STAIR IN
  BUSINESS OCCUPANCIES?
MAXIMUM HEIGHT OF RISER FOR CLASS A
 STAIRS?
MAXIMUM HEIGHT OF RISER FOR CLASS B
 STAIRS?
MINIMUM WIDTH OF CLASS B STAIRS SERVING
 MORE THAN 50 PERSONS?
MINIMUM WIDTH OF CLASS B STAIRS SERVING
 50 PERSONS AND BELOW?
MINIMUM WIDTH OF CLASS A STAIRS?
MAXIMUM PROJECTION OF A HANDRAIL OVER A
 STAIR?
MINIMUM HEIGHT BETWEEN LANDINGS FOR
 CLASS B STAIRS?
MINIMUM WIDTH OF LANDINGS IN DIRECTION
 OF TRAVEL FOR CLASS A AND B STAIRS?
MINIMUM WIDTH OF CLASS A RAMP?
MINIMUM WIDTH OF CLASS B RAMP?
STANDARD SLOPE OF CLASS B RAMP IN
  PERCENTAGE?
MAXIMUM HEIGHT BETWEEN LANDINGS FOR A
 CLASS A RAMP?
MAXIMUM HEIGHT BETWEEN LANDINGS FOR A
 CLASS B RAMP?
MINIMUM WIDTH OF RAMPS FOR 3 OR MORE
 STORIES IN HEIGHT?
MINIMUM WIDTH FOR FIRE ESCAPE FOR
 EXISTING STAIRS?
MINIMUM HORIZONTAL DIMENSION OF ANY
 LANDING OR PLATFORM FOR EXISTING STAIRS
 FOR FIRE ESCAPE?
MAXIMUM RISE FOR FIRE ESCAPE IN SMALL
 BUILDINGS?
MAXIMUM HEIGHT BETWEEN LANDINGS FOR
 FIRE ESCAPE FOR EXISTING STAIRS?
MINIMUM DISTANCE OF TRAVEL TO AN EXIT FOR
 STORAGE OF HIGH HAZARD COMMODITIES?
CLASS OF FIRE INVOLVING COMBUSTIBLE
 METALS, SUCH AS MAGNESIUM, SODIUM,
 POTASSIUM, AND OTHER SIMILAR MATERIALS?
CLASS OF FIRE INVOLVING COMBUSTIBLE
 MATERIALS, SUCH AS WOOD, PAPER, CLOTH,
 RUBBER AND PLASTICS?
A TANK VAT OR CONTAINER OF FLAMMABLE OR
  COMBUSTIBLE LIQUID IN WHICH ARTICLES OR
  MATERIALS ARE IMMERSED FOR THE PURPOSE
  OF COATING, FINISHING, TREATING OR
  SIMILAR PROPERTIES?
AN INTEGRATED SYSTEM OF UNDERGROUND OR
 OVER HEAD PIPING OR BOTH CONNECTED TO
 A SOURCE OF EXTINGUISHING AGENTS OR
 MEDIUM AND DESIGNED IN ACCORDANCE
 WITH FIRE PROTECTION ENGINEERING
 STANDARDS WHICH WHEN ACTUATED BY ITS
 AUTOMATIC DETECTING DEVICE, SUPPRESSES
 FIRE WITHIN THE AREA PROTECTED
A CONTINUOUS AND UNOBSTRUCTED ROUTE OF
  EXIT FROM ANY POINT IN A BUILDING TO A
  PUBLIC WAY
MINIMUM DISTANCE OF AN INCINERATOR
 CONTAINING KINDLED FIRE OR RUBBISH FIRE
 OR BONFIRES
UNDER WHAT CLASSIFICATION DO MUSEUMS
 FALL UNDER?
UNDER WHAT CLASSIFICATION DO TOWN HALLS
 FALL UNDER?
MAXIMUM WIDTH OF A SINGLE DOOR IN A
 DOORWAY?
MINIMUM TREAD FOR FIRE ESCAPE STAIRS FOR
 EXISITING STAIRS?
MAXIMUM SPACING OF RUNGS FOR A FIRE
 ESCAPE LADDER?
MINIMUM SPACING OF RUNGS FOR A FIRE
 ESCAPE LADDER?
CLASS III COMBUSTIBLE LIQUIDS SHALL MEAN
 ANY LIQUID HAVING A FLASH POINT AT HOW
 MANY DEGREES CELSIUS?
IN STANDARD SEATING MINIMUM SPACING BACK
  TO BACK
MINIMUM SPACE FROM THE BACK OF A CHAIR TO
 THE FRONT OF THE CHAIR BEHIND
MAXIMUM SLOPE FOR AISLES FOR PUBLIC
 ASSEMBLY STRUCTURES
SIZE OF STANDPIPE PROVIDED FOR EACH STAGE
  FOR PUBLIC ASSEMBLY BUILDING
OCCUPANT LOAD PER PERSON FOR
 CLASSROOMS
WHERE EXTERIOR CORRIDORS OR BALCONIES
 ARE PROVIDED AS MEANS OF EXIT, THEY
 SHALL OPEN TO THE OUTSIDE AND SHALL BE
 SPACED ______ METERS APART.
 (EDUCATIONAL)
MINIMUM DIMENSION OF A RESCUE WINDOW
 FOR EDUCATIONAL OCCUPANCIES
MAXIMUM HEIGHT FROM THE FLOOR FOR A
 RESCUE WINDOW FOR EDUCATIONAL
 OCCUPANCIES
MINIMUM WIDTH OF CORRIDORS, AISLES, AND
 RAMPS FOR EXITS IN HOSPITALS AND NURSING
 HOMES
MINIMUM WIDTH OF CORRIDORS, AISLES, AND
 RAMPS FOR EXITS IN RESIDENTIAL CUSTODIAL
 CARE
ANY ROOM FOR SLEEPING IN INSTITUTIONAL
 OCCUPANCIES IF SUBDIVIDED SHALL HAVE A
 MAXIMUM AREA OF HOW MANY SQUARE
 METERS.
INCLUDES BUILDINGS OR GROUPS OF BUILDING
  UNDER THE SAME MANAGEMENT IN WHICH
  THERE ARE MORE THAN 15 SLEEPING
  ACCOMODATIONS FOR HIRE.
INCLUDES BUILDINGS CONTAINING THREE OR
  MORE LIVING UNITS INDEPENDENT COOKING
  AND BATHROOM FACILITIES, WHETHER
  DESIGNED AS ROWHOUSE, APARTMENT
  HOUSE, TENEMENT, GARDEN APARTMENT, OR
  BY ANY OTHER NAME.
MINIMUM NUMBER OF STORIES OF APARTMENT
 BUILDINGS REQUIRING FIRE ALARM SYSTEM
MINIMUM NUMBER OF APRTMENT UNITS
 REQUIRING A FIRE ALARM SYSTEM

								
To top