GEZE Emergency power control unit E 260 N 8/...- VdS
Tested according to EN 12101-10
for the control of 24 V DC electric drives in ... (1 to 4) ventilation groups
and one alarm group. Closed circuit controlled, with built-in relay switching,
automatic charger, automatic switch-over from mains to battery operation,
emergency power supply with battery 2 x 12 V for min. 72 hours, control
display for ’Ready‘, ‘Fault‘ and ’Power cut‘ on the front, as well as
7 digit display in the control unit for operational mode.
Enclosure rating: IP 54
Output current max. 7,5 A
Connecting possibilities:
- Rain-wind control
- Smoke detector RM 1003 and/or heat difference detector WM 1005
- Fire button FT4 – VdS
- Ventilator button E50/1 and E50/3 (without display)
- Ventilator button E50/5 or 50/7 (with display)
- Alarm input for external release (fire alarm central unit)
- optional: potential-free status contact for alarm, fault and window OPEN
Technical data:
Input voltage: 230V AC
Output voltage: 24V DC
Enclosure rating: IP 54
Output current: max. 7,5 A
Version:
Surface mounting plastic housing, grey:
___________________________________________________________________________
Item-No. Quantity Unit Unit Price Total Amount
___________________________________________________________________________
Width: 363 mm
Height: 319 mm
Depth: 131 mm
1.1 .......... pcs. .................. € .................. €
GEZE Fire button FT 4 / 24V DC – VdS
for manual release of alarm
with alarm and reset button and LED-display for "Fire Alarm",
"Operation", "Window open" and "Fault", in lockable surface-mounted
housing with label "Smoke Vent",
with break glass pane,
die cast housing in colour:
Finish: orange RAL 2011 (VdS-approval)
Alternative:
( ) red RAL 3000
( ) blue RAL 5005
( ) yellow RAL 1004
( ) grey RAL 7035
1.2 .......... pcs. .................. € .................. €
GEZE Smoke Detector RM 1003/24 V DC with plinth,
for automatic release of alarm in the case of smoke,
VdS-approval
___________________________________________________________________________
Item-No. Quantity Unit Unit Price Total Amount
___________________________________________________________________________
1.3 .......... pcs. .................. € .................. €
GEZE Heat Difference Detector WM 1005/24 V DC with plinth,
for automatic release of alarm in the case of heat,
VdS-approval
1.4 .......... pcs. .................. € .................. €
GEZE Ventilator button for ventilation
( ) E 50/1 "open - stop - close",
( ) surface-mounted
( ) flush-mounted
( ) E 50/3 "open - close",
( ) surface-mounted
( ) flush-mounted
( ) E 50/5 "open – close" with LED,
( ) surface-mounted
( ) flush-mounted
( ) E 50/7 "open - stop - close" with LED,
( ) surface-mounted
( ) flush-mounted
___________________________________________________________________________
Item-No. Quantity Unit Unit Price Total Amount
___________________________________________________________________________
1.5 .......... pcs................. € .................. €
GEZE Key-operated switch E 21 without profile cylinder,
for ventilation pulse open-close, stop by operating separate button flush
1.6 .......... pcs. .................. € .................. €
GEZE Room Temperature Control E 70
for automatic control of the room temperature.
With selection dial for setting the room temperature from 5°C to 30°C
and switch to change over from manual to automatic operation,
(1 piece)
1.7 .......... pcs- .................. € .................. €
GEZE Rain-Wind Control,
for automatic control of ventilation,
consisting of weather station with rain and wind sensor, control unit,
temperature sensor (electr. heated)
(1 piece)
NOTE
Installation of electric cables and connection to be carried out by
customer’s electric contractor in accordance with GEZE cable
diagrams. The type of cable to be used is to be determined with the
___________________________________________________________________________
Item-No. Quantity Unit Unit Price Total Amount
___________________________________________________________________________
respective local authorities.
Get documents about "