amaZon introduction

Document Sample
amaZon introduction Powered By Docstoc
					                    amaZon
                   Introduction




1   January 2010
The new performance level in ion trap
technology:

                         •   Sensitivity: 10x improvement with
     amaZon                  dual ion funnel transfer
                         •   Speed: maximum scan speed of
                             52,000 u/sec at < 0.58u FWHM
                         •   Resolution: up to 20,000 in a
                             seamless scan at 4600 u/s scan
                             speed in m/z 50 - 3000
                         •   Polarity Switching: “Zero Delay
                             AlternatingTM“ for 20 Hz MS
                             spectral rate in both polarities
                         •   ETD/PTR: Most sensitive, robust and
                             easy-to-use setup




 2     January 2010
amaZon – Introduction
                          2009         2010




     HCTultra ETD II      amaZon ETD

     HCTultra             amaZon X

     HCT                  HCTultra

     e6k                  HCT          amaZon SL


 3         January 2010
amaZon – Introduction

 amaZon ETD
      High end proteomics system for
      structure and analysis of proteins and
      peptides
      detailed and easy elucidation of PTMs
      with CID and ETD (PTR).


amaZon X
     High end proteomics and metabolomics system for
     detailed structure analysis with fast LC/MSn and
     lots of data depending scan capabilities
       •   ETD upgrade possible

amaZon SL
     High Capacity Trap powered by dual ion funnel.
     Working horse for identification and
     characterization of metabolites as well as small
     molecule business.
      •   mass range 50-2200 m/z
      •   XtremeScan and standard enhanced resolution
          mode available
 4          January 2010
amaZon – Introduction


                                amaZon overview
     - Complete new device:
      new system architecture,
      chassis, vacuum system & housing…

     - High end processor platform
       same as maXis/solariX – same firmware


     - share hardware modules with other API-mass specs
       ion-optics & electronic modules/parts
       with maXis/solariX


     - Higher MS/MS sensitivity via larger ion current


 5             BDAL
           January 2010Confidential
Software Controlled Syringe Pump




TrapControl Parameter




 7           BDAL
         January 2010Confidential
Bruker Sprayer


     New Bruker ESI nebulizer




                        2




                                       1




      Flow Rate         Inner Needle
       [µl/min]        Position [mm]
                                                          Side inspection of the Tip
         2                  0.6
         20                 0.6
                                              Flow Rate    Inner Needle                Front inspection
        200                 0.25               [µl/min]   Position [mm]
                                                                                          of the Tip
        500                 0.25                 4             0.8
        1000                0.25                200            0

     ESI Sprayer Settings                    APCI Sprayer Settings

 8                    BDAL
                  January 2010Confidential
Modular Multiport Valve

                                                              Rheodyne Valves available
                                                              Analytical Flow:    6 port, 10 port
                                                              Nanoflow:          10 port




                                       TrapControl Parameter




 Available for maXis soon


                                                  July 2009




 9              BDAL
            January 2010Confidential
New Source Electronics




      No additional electronical adapter necessary for APCI and APPI.




 10            BDAL
           January 2010Confidential
amaZon – Introduction

      Same components for all
                                               amaZon specific components
      • Bruker ion source + desolvation unit
                                               • fast switching capillary
      • dual funnel cartridge
                                               • bipolar ion gate
        (solariX with Billerica funnel)
                                               • detector gate
      • source recipient
                                               • pre-trap multipole
      • ETD option + split octopoles
                                               ready for new features
      • self-contacting feedthrough
                                               (pre-trapping / pulsed trapping gas)
      • compound vacuum system




 11               BDAL
              January 2010Confidential
High resistive Glass Capillary (i.d. 0.6 mm)

                                                                   Standard Glass capillary
                                                                Standard glassCapillary                                                         High resistive glass capillary
                                                                                                                                                 Burle Resistive Glass Capillary
                                                          1.2                                                                             1.2


              1stMS        2ndMS                          1.0                                                                             1.0




               -                  +



                                      normalized signal
                                                          0.8                                                                             0.8



                                                          0.6                                                                             0.6
                                                                                                                            322u                                                                           322u
                                                                                                                            622u                                                                           622u

              delay for HCT                               0.4                                                               922u
                                                                                                                            1522u
                                                                                                                                          0.4                                                              922u
                                                                                                                                                                                                           1522u

              800 msec
                                                                                                                            2122u                                                                          2122u
                                                          0.2                                                               2322u         0.2                                                              2322u


                                                          0.0                                                                             0.0
                                                                0   50   100   150     200     250    300      350   400    450     500         0   50   100   150     200     250    300      350   400     450   500

                                                                                     nominal delay time / ms                                                         nominal delay time / ms


                                                          1.2
                                                                                                                                          1.2


                                                          1.0
                                                                                                                                          1.0




                                  -
                                      normalized signal


                                                          0.8



               +
                                                                                                                                          0.8


                                                          0.6
                                                                                                                           602u           0.6
                                                                                                                           1034u                                                                              602u
                                                                                                                           1634u
              delay for HCT
                                                          0.4                                                                                                                                                 1034u
                                                                                                                                          0.4
                                                                                                                           2234u                                                                              1634u
                                                                                                                           2434u                                                                              2234u

              600 msec
                                                          0.2                                                                                                                                                 2434u
                                                                                                                                          0.2


                                                          0.0
                                                                0   50   100   150     200     250    300      350   400    450     500   0.0
                                                                                                                                                0   50   100   150     200     250    300      350   400     450   500
                                                                                     nominal delay time / ms
                                                                                                                                                                     nominal delay time / ms




               amaZon only:
               Dry gas temperature can be set > 200 °C, as with the high resistive glass
               capillary no signal breakdown occurs which is known from ESI-TOF systems.


 12        BDAL
       January 2010Confidential
Dual Funnel Cartridge with ETD Option


                                                           Dual octopole
                                               Funnel 2
                                 Funnel 1




                                            nCI Source    Connection plate




 13       BDAL
      January 2010Confidential
New ETD Electronics




      ETD Source
      Control




      Same ETD electronics box will be placed into maXis and solariX




 14          BDAL
         January 2010Confidential
amaZon Specific Components



                                                                                3
                                                                   2

                                                               1




 Pre-Trap Module 1
 A multipole which is currently used for ion transfer only.

 Bipolar Ion Gate 2
 • Fast response to ensure stable signal intensities at very low accumulation times
 • Both polarities are blocked efficiently (e.g. from 0 V for transmission to +50 V and
   -50 V for blocking)
 (HCT/esquire Series: One half of the split Lens 1 is used for blocking – slow response and
 inefficient for opposite polarity)

 Detector Gate 3
 Lens behind the ion trap which is open for transmission during scan procedures only.

 15             BDAL
            January 2010Confidential
Vacuum Values - He Difference Pressure




  XtremeScan
  UltraScan                         Maximum Resolution   Helium switched off
  Enhanced Resolution


                                                            Standard values for
                                                            Helium difference
                                                            pressure calibration.




 16          BDAL
         January 2010Confidential
Filterunit at Air Inlet

 •




      • Interior of the system stays clean
      • Exchange of filters necessary every 3 – 6 months
      • 2 Filter as spare included with the instrument




 17           BDAL
          January 2010Confidential

				