                                        June 6, 2008


2006 SSPs used with 2006 Standard Plans:

   S1-020, Amendments to the Standard Specifications, approved 06-06-08. This revision
makes changes to Section 49, "Piling."

   S5-060, Public Safety, approved 06-06-08. This revision includes a provision for securing
temporary railing (Type K).

   S5-625, Bird Protection, approved 06-06-08. This revision corrects instructions for including
supplemental funds.

    S5-780, Damage Repair, approved 06-06-08.          This revision corrects instructions for
including supplemental funds.

    S8-M10, State Furnished Materials, approved 06-06-08. This revision updates the list due to
the cancellation of SSPs 86-410, 86-415, 86-530.

    08-015, Progress Schedule (Critical Path Method), approved 06-06-08. This revision
corrects the definition of baseline schedule and modifies paragraph 31 to match new definition.

    05-020, Miscellaneous order of work clauses, approved 06-06-08. This revision deletes
paragraph 7. The provisions in old paragraph 7 were moved to SSPs S5-060, 12-410, and 12-
990. Paragraph 10 was also deleted because the "attention is directed" clause to Water Pollution
Control is not needed.

    12-410, Temporary Railing, approved 06-06-08. This revision incorporates the requirement
to secure the K-rail before work (paragraph 7 from SSP 05-020).

    12-990, Temporary Crash Cushion Module, approved 06-06-08. This revision incorporates
the requirement to secure crash cushion modules before work (paragraph 7 from SSP 05-020)
and changes the requirement for movable pallets or frames to an option for the contractor.

    20-110, Extend Irrigation Crossovers, approved 06-06-08. This revision corrects instructions
for including supplemental funds.

    20-253, Remove Existing Plants for Trenching, approved 06-06-08. This revision corrects
instructions for including supplemental funds.

    20-255, Remove Existing Sod for Trenching, approved 06-06-08 This revision corrects
instructions for including supplemental funds.

    20-301, Locate Existing Crossovers and Conduits, approved 06-06-08. This revision corrects
instructions for including supplemental funds.
    20-305, Maintain Existing Irrigation Facilities, approved 06-06-08. This revision corrects
instructions for including supplemental funds.

    20-400, Roadside Clearing, approved 06-06-08.       This revision corrects instructions for
including supplemental funds.

    20-530, Wild Flower Seeding, approved 06-06-08. This revision corrects an error in
paragraph 5 and the instructions for including supplemental funds.

    20-550, Plant Establishment Work, approved 06-06-08. This revision corrects instructions
for including supplemental funds.

    20-640, Irrigation Systems Functional Test, approved 06-06-08.        This revision corrects
instructions for including supplemental funds.

   39-400, Hot Mix Asphalt Aggregate Lime Treatment - Slurry Method, approved 06-06-08.
This revision clarifies the instructions for paragraph 2 and the measurement and payment clause.

    39-450, Hot Mix Asphalt Aggregate Lime Treatment - Dry Lime Method, approved 06-06-
08. This revision clarifies the instructions for paragraph 2 and the measurement and payment
clause.

   49-200, Piling, approved 06-06-08. This revisions updates piling requirements to match the
changes to Sections 49-1.03, "Determination of Length," and 49-6.01, "Measurement and
Payment," of the Standard Specifications.

    49-230, Load Test Piles, Dynamic Monitoring and Wave Equation, approved 06-06-08. This
revisions updates piling requirements to match the changes to Sections 49-1.03, "Determination
of Length," and 49-6.01, "Measurement and Payment," of the Standard Specifications.

   49-270, Substitutions For Concrete Piling, approved 06-06-08. This revisions updates piling
requirements to match the changes to Sections 49-1.03, "Determination of Length," and 49-6.01,
"Measurement and Payment," of the Standard Specifications.

   49-340, Mass Concrete for Cast-In-Place Concrete Piles, approved 06-06-08. This is a new
SSP.

    49-400, Measurement and Payment (Piling), approved 06-06-08. This revisions updates
piling requirements to match the changes to Sections 49-1.03, "Determination of Length," and
49-6.01, "Measurement and Payment," of the Standard Specifications.

   51-331, Mass Concrete, approved 06-06-08. This is a new SSP.

    62-010, Alternative Pipe, approved 06-06-08. This revision deletes the alternative for spiral
rib pipe from this SSP and corrects format and style. The spiral rib pipe alternative is a new
standalone SSP.

   66-012, Spiral Rib Pipe, approved 06-06-08. This is a new SSP for spiral rib pipe.
    66-015, Composite Steel Spiral Rib Pipe, approved 06-06-08. This is a new SSP that allows
the use of composite steel rib pipe on highway construction projects. It has superior flow
characteristics and can sustain abrasive bed loads. This SSP can be used as a standalone or
alternative pipe specification.

    86-010, Section 10-3. Signals, Lighting And Electrical Systems, approved 06-06-08. This
revision updates the description to match current types of work and changes the instructions to
allow necessary edits.

   86-170, Bonding and Grounding, approved 06-06-08. This revision updates material to
match current practice and changes the instructions to allow necessary edits.

    86-190, Service, approved 06-06-08. This revision updates material and service to match
current practice and changes the instructions to allow necessary edits.

   86-410, Flashing Beacons, cancelled 06-06-08. This SSP is cancelled because incandescent
lamps for flashing beacon units are no longer state-furnished.

   86-415, Flashing Beacons, cancelled 06-06-08. This SSP is cancelled because sign panels
mounted on flashing beacon standards and incandescent lamps for flashing beacon units are no
longer state-furnished.

   86-530, Sign Lighting Fixtures - Incandescent, cancelled 06-06-08. This SSP is cancelled
because lamps for incandescent sign lighting fixtures are no longer state-furnished.

   86-560, Photoelectric Controls, approved 06-06-08. This revision deletes mercury as a
contractor option due to regulation change.

   StdPln, Standard Plan List, approved 06-06-08. This revision updates the list to coincide
with the New and Revised Standard Plans for the 2006 Standard Plans Erratum No. 10.

								