Empirical Attenuation Factors
Predictions & Observational Data
Helen Dawson, Ph.D. Ian Hers, Ph.D. Robert Truesdale
US EPA Region VIII Golder Associates RTI International
Denver, CO Vancouver, BC, Canada RTP, North Carolina
1
Empirical Attenuation Factors
2001-2002 Evaluations (Helen Dawson)
2004 Evaluations (Ian Hers)
Future Evaluations (Robert Truesdale)
2
Measured Attenuation Factors
2001-2002 Database Summary
15 sites, 15 VOCs, 274 total residence/chemical
combinations
35 BTEX; 239 CHC residence/chemical combinations
99 sites with IA > 10-6 IA RBC
(84 CHC, 14 BTEX)
68 sites with IA > 10-5 IA RBC
3
2001 – 2002 Empirical Attenuation Factors
Groundwater-to-Indoor Air
All residences and chemicals with concentrations above MDLs
Measured Groundwater-Indoor
Air Attenuation Factors
45 120%
40
100%
35
Frequency
30 80%
25
60%
20
15 40%
10
20%
5
0 0%
1.00E-07
1.00E-06
1.00E-05
1.00E-04
1.00E-03
1.00E-02
1.00E-01
1.00E+00
4
Factors evaluated (2001 – 2002)
Chemical type
Foundation type
Soil type
Depth to source
5
2001 – 2002 Empirical Attenuation Factors
Chlorinated Hydrocarbons vs. BTEX
Measured Attenuation Factors
Groundwater to Indoor Air
1
0.1
Attenuation Factor
0.01
IA BTEX > 10-6
0.001
0.0001 IA CHC > 10-6
0.00001
0.000001
0.0000001
0% 20% 40% 60% 80% 100%
Cumulative %
6
2001 – 2002 Empirical Attenuation Factors
Influence of Foundation Structure?
Database
Groundwater
10000000
Groundwater Source Vapor
1000000
Basement
100000
Crawlspace
(ug/m3)
10000 Slab on Grade
1000 1:1
100
10
1
0.01 0.1 1 10 100 1000
Indoor Air (ug/m3)
7
2001 – 2002 Empirical Attenuation Factors
Influence of Foundation Structure?
Lowry Air Force Base
Foundation Vapor vs Indoor Air
10000
Subslab or Crawlspace
1000
100
Basement
(ug/m3)
10 Crawlspace
1:1
1
0.1
0.01
0.01 0.1 1 10 100
Indoor Air (ug/m3)
8
2001 – 2002 Empirical Attenuation Factors
Influence of Soil Type?
Database
10000000
Groundwater Source Vapor
1000000
100000 Silts & Clays
(ug/m3)
10000 Sands
1:1
1000
100
10
1
0.01 0.1 1 10 100 1000
Indoor Air (ug/m3)
9
2001 – 2002 Empirical Attenuation Factors
Depth to Groundwater?
Groundwater Indoor Air Attenuation Factor
Versus Depth to Water
10000000
1 / Attenuation Factor
1000000
100000
10000
Sands
Silts & Clays
1000
100
10
1
0.0 2.0 4.0 6.0 8.0 10.0 12.0
Depth to Water (m)
10
2001 – 2002 Empirical Attenuation Factors
Conclusions
Measured attenuation factors range from 10-2
to 10-7 with median values around 10-4.
Influence of foundation type, soil type, and
depth to water on the empirical attenuation
factors is unclear.
Higher ranges of attenuation factors are
observed for BTEX compounds; median value
is around 10-5.
11