FOOTINGS                                                       CAR ACCOMMODATION                                             FIXING
Concrete waffle slab. Engineer designed                        Lock up garage under main roofline including                  Internal doors – Category 1 flush panel
‘M’ class (one concrete pump allowance).                       Category 1 manual roller door with painted                    2040mm high.
                                                               cement sheet clad lintel (or as predetermined                 Internal door furniture – Selection from Builder’s
Maximum 300mm fall and no existing fill.
                                                               with facade options), rear pedestrian access                  Category 1 Range. Doorstops throughout.
Slab costs will be adjusted if founding                                                                                      Robes – Single melamine shelf with metal
conditions differ.                                             door (space permitting), plaster lined ceiling
                                                               & side walls, structural concrete floor, double               hanging rod.
BUILDING ALLOTMENT                                             power point & batten light point. (Some                       Joinery – Painted finish Category 1 MDF
Based on building allotment of up to 700m2                     models have carport instead of garage)                        67x12mm skirtings and 42x12mm architraves.
and a maximum building set back of 5m                          (Double storeys have brick infill above garage                (100mm tiled skirtings to wet areas).
(subject to Planning Authority).                               door & brick side walls, specific design                      STAIRCASE (IF APPLICABLE)
                                                               exceptions apply).                                            MDF bullnose treads and risers, 1020mm
SERVICES - CONNECTIONS                                                                                                       high plaster dwarf wall only.
Includes connection to water, sewer and                        CEILING HEIGHT
                                                               2440mm ceiling height (nominal) with                          PAINT
stormwater points within the allotment and
                                                               75mm cove cornice. Double storeys 2740mm                      Two coat application of Category 1 paints
connection to underground power and gas                        (nominal) to ground floor. 2526mm ceiling                     throughout – Low sheen washable acrylic
services immediately adjacent to the allotment.                height (nominal) to garages (specific design                  to internal walls, acrylic ceiling paint. Gloss
Excludes telephone connection costs and all                    exceptions apply).                                            enamel paint to internal timberwork and
consumer account-opening fees.                                                                                               doors. Acrylic paint finish to exterior timber,
                                                               TILING
BRICKS                                                                                                                       metal work & cladding, gloss finish to
                                                               Floor and wall tiles to wet areas and kitchen,
                                                                                                                             entrance door. Note: Walls, ceilings and
Selection from Builder’s Category 1 Range.                     floor tiling to entry & meals, selection from
                                                                                                                             internal woodwork to be one colour
                                                               Builder’s Category 1 Range (family included,
FRAMING                                                                                                                      throughout (white ceilings optional).
                                                               some designs only, as predetermined by
Prefabricated stabilized pine wall frames and                  Builder). Wet areas have 100mm tiled skirtings                ELECTRICAL
roof trusses.                                                  to match floor tiles.                                         Category 2 light fittings to all rooms, batten
ROOFING                                                                                                                      fitting to garage. Double power points
                                                               CARPET                                                        throughout. RCD safety switch. TV point
Selection from Builder’s Category 1 Range of                   Selection from Builder’s Category 1 Range                     (Qty x 1). Exhaust fans over showers.
concrete roof tiles (colour on) with 22.5 degree               to untiled dwelling areas.                                    Telephone point to kitchen. Smoke detectors
roof pitch.                                                    HEATING                                                       wired direct. White cover plates. Weatherproof
WINDOWS                                                        Ducted heating (gas fired with manual                         batten fitting to external doors, excluding garage.
Aluminium sliding throughout (including locks),                thermostat) with ceiling ducts to all habitable               ALSO INCLUDED
unless otherwise noted on facade selection.                    rooms (includes bedrooms) in accordance with                  5-Star compliance.
                                                               manufacturers specification.                                  Bushfire attack level - low compliance.
INSULATION (DWELLING ONLY)                                     KITCHEN                                                       Soil test and contour levels.
Builder’s wrap & batts to external walls and                   Base and overhead cupboards with fully                        6½ year structural guarantee.
batts to ceiling or additional insulation as                   lined melamine interior, Category 1 laminated                 3 month defects liability period.
specified in 5-Star report.                                    bench tops and pre-laminated doors and
PLUMBING                                                       panels. Microwave space with power point
                                                               & underneath pot drawer. Stainless steel
Concealed plumbing (except for spa pump, if
                                                               1¾ bowl kitchen sink with side drainer.
applicable), poly piping. Colorbond® fascia,
                                                               Dishwasher space & connections.
quad gutter and rectangular down pipes.                        Pantry with 4 melamine shelves.
HOT WATER SERVICE*                                             APPLIANCES
Gas-boosted, solar hot water service with                      Fixtures refer to “Inspiration” Specification List.
2 collector panels.                                            BATHROOM, ENSUITE & WC
(House siting may require additional panel/s,                  Fixtures refer to “Inspiration” Specification
this will be at extra cost to owner).                          List. Shower tiles to minimum 2000mm above
EXTERIOR HINGED DOORS                                          base, Category 1 semi frameless screen to
Front Entry – Selection from Builder’s Category                1950mm high. Bath tiles to hob and minimum
1 or predetermined with facade choice,                         600mm above.                                                  DISCLAIMER - The above inclusions relate to our base house price
                                                                                                                             with Traditional facade. Please refer to our specific house display
includes weather seal & entrance lockset with                  TAPS                                                          options lists for extra items and costs. Burbank Group reserves the
                                                               Fixtures refer to “Inspiration” Specification List.           right to alter any of the above specifications without notice. *Future
keyed alike deadbolt.                                                                                                        trees or buildings constructed on adjoining lots may alter the 5-Star
Garage access (if applicable) – Flush panel door                                                                             and solar hot water service performance. These inclusions apply
                                                               LAUNDRY                                                       only to the Burbank Complete Collection of homes & supersede any
to garage (no deadbolt).                                       Fixtures refer to “Inspiration” Specification List.           previous inclusions sheets. Effective 1st June, 2009.