					                  DRAFT STATEMENT OF WORK (SOW)
           SECTION C- Descriptions and Specifications

1.0 BACKGROUND

The Naval Surface Warfare Center, Dahlgren Division (NSWCDD), F
Department, is assigned as Acquisition Engineering Agent (AEA)
for Surface Ship Self Defense System (SSDS) Mark 2 by Program
Executive Officer (PEO) Integrated Warfare Systems (IWS). The
Contractor shall deliver hardware as specified by the Government
Technical Data Package as per individual delivery orders. The
SSDS Mk2 system includes Modification 1D for aircraft carriers
up through CVN 76; Mod 2D for LPD 17 Class; Mod 5C for LSD 41/49
Classes; and Mod 6C for CVN 78 Class. The SSDS Mk2 system
consists of, but is not limited to:

Command and Control Group (CCG) OK-691(V)1 and 2
    -Tactical Computer Console (TCC) OJ-830 (V)2
    -Common Display System (CDS) Variant "B" with Field
     Change OJ-836/U (CDS Variant B will be provided as GFE)
    -Electronic Equipment Cabinet (EEE) (Left) SA-2811/U
    -Electronic Equipment Cabinet (EEE) (Right) SA-
     811A/U
    -Electronic Equipment Cabinet (EEE) (Right) SA-2811A/U
     with CWIS Sim
PTC for Advanced Computer Enclosure (ACE) Remote Computer
  Equipment Module (CEM)(ARC) nomenclature pending.
  Hotel solution (ARC will be provided as GFE)
Tactical Computer Console OJ-830 (V)1
Mini-I/O Signal Data Converter Group OU-184(V) 1 CVN
Mini-I/O Signal Data Converter Group OU-184(V) 2 CVN
Mini-I/O Signal Data Converter Group OU-184(V) 3 LHD
Mini-I/O Signal Data Converter Group OU-184(V) 4 LHD
Mini-I/O Signal Data Converter Group OU-184(V) 6 CVN
Mini-I/O Signal Data Converter Group OU-184(V) 4 CVN
Mini-I/O Signal Data Converter Group OU-184(V) 7 LPD
Mini-I/O Signal Data Converter Group OU-184(V) 5 LSD
Multipurpose Enclosure (MPE) CV-4437/F Type A/E
Multipurpose Enclosure (MPE) CV-4437/B Type D
Multipurpose Enclosure (MPE) CV-4437/C Ethernet to
  Ethernet
Multipurpose Enclosure (MPE) CV-4437/D RTE (Barco RTE Card is
  GFE)
Multipurpose Enclosure (MPE) CV-4437/E IRIS (IRIS card Set is
  GFE)
Uninterrupted Power Source (UPS) Rack (440VAC) PP-xxxx/U CPS UPS
  rack
Uninterrupted Power Source (UPS) Rack (115VAC) PP-8580/U
  Indicate CDS
Boundary Defense Cabinet (BDC), nomenclature pending
Maintenance Assist Modules (MAMs) Cabinet, CY-8830C/S
Automated Status Board (ASTAB) DU-20A/S and DU-20B/S
CDS VAB 3-Panel Insert
CDS FC Communication Panel Orbit LSD
CDS FC DVI LSD
CDS FC Push to Talk LSD
Color Large Screen Display (CLSD) LSD
Color Large Screen Display (CLSD) CVN
Local Control Panel (LCP)
Network Switch Cabinet (NSC)
Maintenance Table
24" MONITOR
3U UPS
3U UPS BATTERY
4U UPS
4U UPS BATTERY
AC LINE FILTER
ACCESSORY HUB
AIR FILTER
AIR MANAGEMENT BLADE
Advanced Management Module (AMM)
ASSEMBLY, BIT-STATUS (SSW/TAO)
ASSEMBLY, BIT-STATUS (WSW/TAO)
ASSEMBLY, CARD CAGE (V1)
ASSEMBLY, CARD CAGE (V2)
ASSEMBLY, CARD CAGE (V3)
ASSEMBLY, CARD CAGE (V4)
ASSEMBLY, CARD CAGE (V5)
ASSEMBLY, CONTROL PANEL
ASSEMBLY, CONTROL PANEL
ASSEMBLY, CONTROL-STATUS (WSW/TAO)
ASSEMBLY, STATUS-CONTROL (SSW/TAO)
CCA, NTDS TYPE A
CCA, NTDS TYPE A and or E
CCA, NTDS TYPE D
CCA, NTDS TYPE E
CCA, PROCESSOR BOARD (7806RC)
CCA, PROCESSOR BOARD (7809)
CCA, RTE
CCA, VIDEO DIGITIZER (VDAD2)
CIRCUIT BREAKER
CIRCUIT BREAKER
CIRCUIT BREAKER
CISCO 3750G ETHERNET SWITCH
CISCO IPS 4255
CIWS SIM (Oracle Server)
COMPACT FLASH (7809)
COMPACT FLASH (7806)
CONTROL MODULE
CONTROL MODULE
CONTROL PANEL
CONTROL PANEL (Card Cage)
DIODE
Display
Dust Filter
EMI Filter
ETHERNET SWITCH
FAN (Oracle Server)
Fan (Oracle Server)
FAN GUARD, CABINET
FAN GUARD, CARD CAGE
FAN GUARD, EXHAUST
FAN GUARD, EXHAUST
FAN GUARD, POWER SUPPLY
FAN MODULE (BLADECENTER)
FAN, CABINET
FAN, CABINET
FAN, CARD CAGE
FAN, CARD CAGE
FAN, EXHAUST
FAN, EXHAUST
FAN, EXHAUST
FAN, LOWER CARD CAGE
FAN, POWER SUPPLY
FAN, POWER SUPPLY
FAN, UPPER CARD CAGE
Fuse
GUARD, FAN CABINET
Hard Drive (Oracle Server)
HARD DRIVES (BLADECENTER)
HOUSING, LAMP
HS-22 8GB MEMORY
HS22 BLADE SERVER
HS22 CMOS BATTERY
HS22 SAS CONNECTIVITY CARD
ICPT MODULE
INDICATOR, LED (PLUG IN) GREEN
INDICATOR, LED (PLUG IN) RED
INDICATOR, LED (PLUG IN) YELLOW
INTERFACE UNIT, (1000BASE-LX SFP Module)
IRIS CABLE (CV-44437)
IRIS CABLE, Trigger-Video (OU-184)
IRIS CABLE, Trigger-Video (OU-184)
IRIS CABLE, RADDS (OU-184)
IRIS CABLE, RADDS (OU-184)
Keyboard / Trackball Assembly
KVM Switch
LAMP, CLEAR, 120 VAC
LED (CLEAR)
LED, CLEAR
LENS, COVER, GREEN
LENS, COVER, RED
LENS, COVER, YELLOW
Media Converter
MEDIA TRAY (BLADECENTER)
PDU
POWER DISTRIBUTION (PDU)
Power Supply
POWER SUPPLY
Power Supply (Bladecenter)
Power Supply (Oracle Server)
POWER SUPPLY, DUAL, 24VDC
Printer
PTC ASSEMBLY
RGBHV, BNC
RGBHV, DVI
RTE CABLE (CV-4437)
RTE CABLE (OU-184)
SAS BATTERIES
SAS and or RAID MODULE
SENSOR, TEMPERATURE
SENSOR, TEMPERATURE (DOMAIN 1)
SENSOR, TEMPERATURE (DOMAIN 2)
SENSOR, TEMPERATURE (DOMAIN 3)
SENSOR, TEMPERATURE (DOMAIN 4)
SENSOR, TEMPERATURE (DOMAIN 5)
SENSOR, TEMPERATURE (DOMAIN 6)
SENSOR, TEMPERATURE (EXTERNAL 1)
SENSOR, TEMPERATURE (EXTERNAL 2)
SOLID STATE RELAY
STATUS PANEL (Card Cage)
SWITCH, ON-OFF
TYPE A SABTECH CABLE (CV-4437)
TYPE A SABTECH CABLE (OU-184)
TYPE A SABTECH CABLE (OU-184)
TYPE D SABTECH CABLE (CV-4437)
TYPE D SABTECH CABLE (CV-4437)
TYPE D SABTECH CABLE (OU-184)
TYPE E SABTECH CABLE (CV-4437)
TYPE E SABTECH CABLE (CV-4437)
TYPE E SABTECH CABLE (OU-184)
UTILITY SERVER
ORBIT COMM PANEL
DVI - RGB CONVERTER
PTT SPLITTER
VIDEO SWITCH

1.1   SCOPE

This SOW describes the general requirements for hardware
procurement in support of the SSDS Mk2. The contractor shall
deliver hardware as specified by the Government’s Technical Data
Package and per individual delivery orders. The scope includes
(1) hardware production (which may include GFE), assembly,
configuration, alignment, integration, testing and shipping for
the SSDS Mk2 system hardware, typically ordered by the cabinet;
and (2) delivery of specific electronic components which
although they form a part of a cabinet, may be ordered un-
integrated for the purpose of Installation and Checkout (INCO)
spares or for populating Maintenance Assist Modules (MAMs)
cabinets. For this reason, Section B of the solicitation is
organized to provide ordering options for complete integrated
and tested cabinets or for ordering specified components of
cabinets. Orders will be placed by Delivery Order, which will
specify cabinets and or components to be acquired and place and
date of delivery.
2.0 APPLICABLE DOCUMENTS

The following documents form a part of this SOW, to the extent
specified herein. In the event of conflict between the
documents referenced and the contents of this SOW, the SOW shall
be considered a superseding requirement. For convenience of
reference, the SOW text cites only the document title.

2.1 MILITARY STANDARDS

MIL-STD-108E           Definitions of and Basic Requirements for
                       Enclosures for Electronic Equipment, 4 Aug
                       1996
MIL-STD-167-1A         Mechanical Vibrations of Shipboard
                       Equipment (Type I – Environmental and Type
                       II – Internally Excited), 2 Nov 2005
MIL-STD-461F           Electromagnetic Emissions and
                       Susceptibility, Requirements for the
                       Control of Electromagnetic Interference
                       (EI), 10 Dec 2007
MIL-STD-740-1          Airborne Sound Measurements and Acceptance
                       Criteria of Shipboard Equipment, 30 Dec
                       1986
MIL-STD-740-2          Structure-Borne Vibratory Acceleration
                       Measurements and Acceptance Criteria of
                       Shipboard Equipment, 30 Dec 1986
MIL-STD-810F           Environmental Engineering Considerations
                       and Laboratory Tests, 1 Jan 2000
MIL-STD-901D           Shock Tests, H.I. (High Impact) Shipboard
                       Machinery, Equipment, and Systems
                       Requirements, 17 Mar 1986
MIL-STD-1399C          Interface Standard for Shipboard Systems, 2
                       Feb 1988
MIL-HDBK-2036          General Requirements for Electronic
                       Equipment Specifications, 1 Nov 1999
MIL-STD-2073-1E with   Standard Practice for Military Packaging, 7 Jan
Change 1               2011
MIL-STD-129P with      Military Marking for Shipment and Storage, 19
Change 4               Sept 2007

2.2 OTHER SPECIFICATIONS AND STANDARDS

9470-002-A-X-C         Configuration Management Plan (CMP) for PEO
                       TSC Programs, 5 Jan 1996
EIA/IS-632            Systems Engineering, Dec 1994
IEC-68-2-3            Basic environmental testing procedures
                      (Non-condensing humidity), 1 Jan 1986
ISO 9001              Quality Systems – Model for Quality
                      Assurance in Design, Development,
                      Production, Installation and Servicing
WS35511B              Ship Self Defense System (SSDS) Mk2
                      Systems/Subsystem Specification (SSS), for
                      Mod May 2004

2.3 PRECEDENCE

In case of disagreement between a reference listed above and
information contained in the Government Technical Data Package,
the information in the Government Technical Data Package shall
take precedence.

3.0 REQUIREMENTS: SSDS MK2 HARDWARE PRODUCTION

The Contractor shall provide hardware production, assembly,
configuration, alignment, integration, testing, and shipping for
the SSDS Mk2 system hardware as specified by the Government
Technical Data Package, consisting of mechanical, electrical and
assembly drawings.

SSDS Mk 2 hardware production includes assembly and integration;
testing of the assembled hardware in accordance with Government
provided Factory Qualification Test procedures; labeling of the
assembled hardware with label plates including Unique
Identification (UID) information; packaging and crating of the
hardware for shipment; and shipment to locations specified in
individual delivery orders. Installation of the equipment
aboard ship is not included in this Statement of Work.


3.1 PRODUCTION PLAN

The contractor shall provide a Production Plan (CDRL A001)
within two weeks of receipt of order for equipment production
under that order. The Production Plan shall show major
milestones, including: (1) dates by which Government Furnished
Equipment (GFE) is required; (2) the planned schedule for
conduct of Factory Qualification Test in order to provide an
opportunity for Government personnel to observe; and (3) other
major activities and milestones to facilitate Government
monitoring of progress. The Government will accept or request
to enter into discussion regarding the plan within one week of
receipt.

3.2 CONDUCT OF FACTORY QUALIFICATION TEST

The contractor shall allow for Government observation of Factory
Qualification Test.

3.3 REQUESTS FOR DEVIATIONS AND WAIVERS

The contractor shall provide for Government approval, a Request
for Deviation (CDRL A002) and a Request for Waiver (CDRL A003),
when warranted, as a proposed remedy for failure of produced
equipment to pass a Government Factory Qualification Test
procedure.

4.0 OTHER REQUIREMENTS

4.1 MONTHLY STATUS REPORTS

The contractor shall provide monthly production status reports
(CDRL A0004), which includes a current production plan with
status, major milestones, issues encountered and financial
status. The contractor shall support discussion regarding the
resolution of issues.

4.2 FINAL REPORT

The contractor shall provide a final report (CDRL A0005) at the
completion of each delivery order. The final report shall
include at a minimum: a summary of Factory Qualification Tests,
a summary of shipment of equipment, any approved deviations and
waivers, and a summary of issues and resolutions during
execution of the delivery order.

4.2 GOVERNMENT FURNISHED EQUIPMENT (GFE), GOVERNMENT FURNISHED
INFORMATION (GFI) AND GOVERNMENT FURNISHED PROPERTY (GFP)

  (a)    The contractor shall account for and manage all
    GFE/GFI/GFP. The contractor shall inspect GFE/GFI/GFP upon
    receipt and maintain the status of all GFE/GFI/GFP in
    custody.
  (b)    The GFE/GFI/GFP requirements will be listed in Section
    J as an attachment to the contract.

4.3 TECHNICAL RECOMMENDATIONS

The contractor is encouraged to provide recommendations which
reduce unit cost and or improve product quality.

4.4 PLANNED ORDERS

For informational purposes, the following list of planned orders
is provided. It is based upon the SSDS Mk 1 and Mk 2 System
Procurement Plan dated 16 April 2012. This plan is subject to
change.

4.4.1 FY13 PLANNED SSDS MK 2 HARDWARE ORDERS:

MK 2 CVN 70 , Mod 1D
TCC OJ-830(V)1 (x2)
OU-184(V)6 Mini I/O Signal Data Converter Group
MPE CV-4437(D) for RTE
MPE CV-4437(F) for Type A/E interface
ACE UPS Cabinet for CPS (x2)
BDC (x2)
Network Switch Cabinet (NSC) OL-782(V)/S x2

MK 2 Maint Trainer, Mod 1D
TCC OJ-830(V)1 (x2)
OU-184(V)6 Mini I/O Signal Data Converter Group
MPE (x2)
ACE UPS Cabinet for CPS (x2)
BDC (x2)
Network Switch Cabinet (NSC) OL-782(V)/S x2

MK 2 Oper/Maint Trainer, Mod 6C
TCC OJ-830(V)1 (x2)
Command Control Group (CCG) OK-691(V)1 and 2
CDS FC (X2) from two monitors to one monitor
CDS FC from two vertical monitors to two Horizontal
OU-184(V)1 Mini I/O Signal Data Converter Group
OU-184(V)2 Mini I/O Signal Data Converter Group
MPE CV-4437(F) for NTDS E
MPE CV-4437(C) for CIWS (x3)
ARC Cabinets (x5)
Network Switch Cabinet (NSC) OL-782(V)/S x2
ACE UPS Cabinet for CPS (x2)
UPS Cabinet for CDS (x2)
BDC (x2)

MK 2 LSD 44, Mod 5C
TCC OJ-830(V)1 (x2)
Command Control Group (CCG) OK-691(V)1 and 2
CDS FC (X3) from two eye to one eye display
CDS VAB 3-Panel Insert (X3)
CDS VAB Swap (X3)
OU-184(V)5 Mini I/O Signal Data Converter Group
MPE Ethernet Interface Adapter (x2)
MPE IRIS Interface Adapter (x3)
CDS FC Communication Panel Orbit (x3)
CDS FC DVI (x3)
ARC Cabinets (x1)
ACE UPS Cabinet for CPS (x2)
CLSD x 3
Network Switch Cabinet (NSC) OL-782(V)/S x2

MK 2 LSD 49, Mod 5C
TCC OJ-830(V)1 (x2)
Command Control Group (CCG) OK-691(V)1 and 2
CDS FC (X3) from two eye to one eye display
CDS VAB 3-Panel Insert (X3)
CDS VAB Swap (X3)
OU-184(V)5 Mini I/O Signal Data Converter Group
MPE Ethernet Interface Adapter (x2)
MPE IRIS Interface Adapter (x3)
CDS FC Communication Panel Orbit (x3)
CDS FC DVI (x3)
ARC Cabinets (x1)
ACE UPS Cabinet for CPS (x2)
CLSD x 3
Network Switch Cabinet (NSC) OL-782(V)/S x2
4.4.2 FY14 PLANNED SSDS MK 2 HARDWARE ORDERS:

MK 2 CVN 79 , Mod 6C
TCC OJ-830(V)1 (x2)
Command Control Group (CCG) OK-691(V)1 and 2
CDS FC (X2) from two monitors to one monitor
CDS FC from two vertical monitors to two Horizontal
CDS VAB Swap (X38)
OU-184(V)1 Mini I/O Cabinet
OU-184(V)2
MPE CV-4437(F) for NTDS E
MPE CV-4437(C) for CIWS (x3)
ARC Cabinets (x5)
ACE UPS Cabinet for CPS (x2)
BDC (x2)
UPS Cabinet for CDS (x2)
CDS VAB 3-Panel Insert (X4)
LCP x 7
Network Switch Cabinet (NSC) OL-782(V)/S x2

MK 2 LSD 45, Mod 5C
TCC OJ-830(V)1 (x2)
Command Control Group (CCG) OK-691(V)1 and 2
CDS FC (X3) from two eye to one eye display
CDS VAB 3-Panel Insert (X3)
CDS VAB Swap (X3)
OU-184(V)5 Mini I/O Signal Data Converter Group
MPE CV-4437(C) Ethernet Interface Adapter (x2)
MPE CV-4437(E) IRIS Interface Adapter (x3)
CDS FC Communication Panel Orbit (x3)
CDS FC DVI (x3)
ARC Cabinets (x1)
ACE UPS Cabinet for CPS (x2)
CLSD x 3
Network Switch Cabinet (NSC) OL-782(V)/S x2

MK 2 LSD 47, Mod 5C
TCC OJ-830(V)1 (x2)
Command Control Group (CCG) OK-691(V)1 and 2
CDS FC (X3) from two eye to one eye display
CDS VAB 3-Panel Insert (X3)
CDS VAB Swap (X3)
MPE CV-4437(C) Ethernet Interface Adapter (x2)
MPE CV-4437(E) IRIS Interface Adapter (x3)
CDS FC Communication Panel Orbit (x3)
CDS FC DVI (x3)
ARC Cabinets (x1)
ACE UPS Cabinet for CPS (x2)
OU-184(V)5 Mini I/O Signal Data Converter Group
CLSD x 3
Network Switch Cabinet (NSC) OL-782(V)/S x2

MK 2 LPD 19, Mod 2D
TCC OJ-830(V)1 (x2)
OU-184(V)7 Mini I/O Signal Data Converter Group
MPE CV-4437(D) for RTE
MPE CV-4437(F) for Type A/E interface
ACE UPS Cabinet for CPS (x2)
BDC (x2)
Network Switch Cabinet (NSC) OL-782(V)/S x2

4.5 MANDATORY REQUIREMENTS

The following requirements are mandatory and must be met prior
to award of a contract, as well as maintained throughout the
period of performance:

   The contractor’s facility must be located on the continental
     United States
   All personnel performing technical tasks under this contract
     must be United States citizens

				