Splinter
Document Sample


SPLINTER User Manual
Version 12
ANSYS, Inc.
Southpointe
275 Technology Drive
Canonsburg, PA 15317
ansysinfo@ansys.com
http://www.ansys.com
(T) 724-746-3304
(F) 724-514-9494
© Copyright 2009. Century Dynamics Limited. All Rights Reserved.
Century Dynamics is a subsidiary of ANSYS, Inc.
Unauthorised use, distribution or duplication is prohibited.
ANSYS, Inc. is certified to ISO 9001:2008
Revision Information
The information in this guide applies to all ANSYS, Inc. products released on or after this date, until superseded
by a newer version of this guide. This guide replaces individual product installation guides from previous
releases.
Copyright and Trademark Information
© 2009 SAS IP, Inc. All rights reserved. Unauthorized use, distribution or duplication is prohibited.
ANSYS, ANSYS Workbench, AUTODYN, CFX, FLUENT and any and all ANSYS, Inc. brand, product,
service and feature names, logos and slogans are registered trademarks or trademarks of ANSYS, Inc. or its
subsidiaries located in the United States or other countries. ICEM CFD is a trademark used by ANSYS, Inc.
under license. All other brand, product, service and feature names or trademarks are the property of their
respective owners.
Disclaimer Notice
THIS ANSYS SOFTWARE PRODUCT AND PROGRAM DOCUMENTATION INCLUDE TRADE
SECRETS AND ARE CONFIDENTIAL AND PROPRIETARY PRODUCTS OF ANSYS, INC., ITS
SUBSIDIARIES, OR LICENSORS. The software products and documentation are furnished by ANSYS, Inc.,
its subsidiaries, or affiliates under a software license agreement that contains provisions concerning non-
disclosure, copying, length and nature of use, compliance with exporting laws, warranties, disclaimers,
limitations of liability, and remedies, and other provisions. The software products and documentation may be
used, disclosed, transferred, or copied only in accordance with the terms and conditions of that software license
agreement.
ANSYS, Inc. is certified to ISO 9001:2008
U.S. Government Rights
For U.S. Government users, except as specifically granted by the ANSYS, Inc. software license agreement, the
use, duplication, or disclosure by the United States Government is subject to restrictions stated in the ANSYS,
Inc. software license agreement and FAR 12.212 (for non-DOD licenses).
Third-Party Software
The products described in this document contain the following licensed software that requires reproduction of
the following notices.
Formula One is a trademark of Visual Components, Inc.
The product contains Formula One from Visual Components, Inc. Copyright 1994-1995. All rights reserved.
See the legal information in the product help files for the complete Legal Notice for ANSYS proprietary
software and third-party software. If you are unable to access the Legal Notice, please contact ANSYS, Inc.
Published in the U.S.A.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates.
SPLINTER User Manual
Update Sheet for Version 12
April 2009
Modifications:
The following modifications have been incorporated:
Section Page(s) Update/Addition Explanation
All All Update Conversion to Microsoft® Word format
1.2 1-3 Update Delete references to legacy program PICASO
2.2.3 2-23 Update Add ED21Edition number
3.5 3-37, 3-38 Update Add ED21Edition number
App A.3 A-3 Update Delete references to legacy program ASDIS
App A.16 A-12 Update Delete references to legacy program PICASO
App A.18 A-16 Update Delete references to legacy program ADLIB
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates.
SPLINTER User Manual Contents
TABLE OF CONTENTS
1. Introduction ........................................................................................................ 1-1
1.1. Single Pile Analysis ...................................................................... 1-1
1.2. Soil-Pile-Structure Interaction Analysis ....................................... 1-3
1.3. Pile Group Interaction effects ....................................................... 1-4
1.4. Automatic Pile Subdivision .......................................................... 1-6
1.5. Convergence criteria ..................................................................... 1-7
1.6. Soil representation ........................................................................ 1-8
1.7. Mudslides.................................................................................... 1-10
1.8. Node numbers and coordinates................................................... 1-11
1.9. Global and Local Axis Systems.................................................. 1-13
1.9.1. Coordinate Local Axes ............................................................... 1-13
1.9.2. Element Local Axes.................................................................... 1-13
1.9.3. Skew Systems ............................................................................. 1-13
1.10. Results from Splinter .................................................................. 1-14
1.10.1. Data Echo ................................................................................... 1-14
1.10.2. Expanded Data and Summaries .................................................. 1-14
1.10.3. Results - Displacements and Reactions ...................................... 1-14
1.10.4. Results - Forces and Stresses ...................................................... 1-15
1.10.5. Results Pile Cap Stiffness ........................................................... 1-15
1.11. Data Units ................................................................................... 1-24
1.12. Outline of this Manual ................................................................ 1-24
2. Data Formats ...................................................................................................... 2-1
2.1. Free format syntax ........................................................................ 2-1
2.1.1. General Principals......................................................................... 2-1
2.1.2. Special Symbols ........................................................................... 2-4
2.1.3. Repeat Facilities ........................................................................... 2-5
2.1.4. Re-Repeat Facilities ...................................................................... 2-6
2.2. Data requirements for each type of analysis ................................. 2-8
2.2.1. Single pile ..................................................................................... 2-9
2.2.2. Group Pile Data .......................................................................... 2-14
2.2.3. Pile-structure Interaction Data .................................................... 2-19
2.2.4. Stiffness Input Data .................................................................... 2-24
3. Data Description ................................................................................................ 3-1
3.1. Preliminary Data ........................................................................... 3-1
3.2. Structural Data .............................................................................. 3-1
3.2.1. UNITS Command for Structural Data .......................................... 3-1
3.2.2. COORDINATE Data .................................................................... 3-4
3.2.3. PILE Topology Data ..................................................................... 3-5
3.2.4. Material Properties ....................................................................... 3-8
3.2.5. Geometric Properties .................................................................... 3-8
3.2.6. Skew Systems ............................................................................... 3-8
3.2.7. Component Topology ................................................................... 3-8
3.2.8. SOIL Data ..................................................................................... 3-9
3.2.9. PILE GROUP Definition ............................................................ 3-29
3.2.10. SECTION Data ........................................................................... 3-31
3.3. BOUNDARY Conditions Data .................................................. 3-33
3.3.1. UNITS Command for Boundary Conditions .............................. 3-33
3.3.2. SUPPRESSIONS Data ............................................................... 3-34
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. i
SPLINTER User Manual Contents
3.3.3. DISPLACED FREEDOMS Data ............................................... 3-34
3.3.4. CONSTRAINT EQUATIONS Data .......................................... 3-34
3.3.5. LINK FREEDOM Data .............................................................. 3-34
3.3.6. RIGID CONSTRAINTS Data .................................................... 3-34
3.3.7. FREEDOM RELEASE Data ...................................................... 3-34
3.4. LOAD Data................................................................................. 3-35
3.4.1. UNITS Command for LOAD Data ............................................ 3-35
3.4.2. NODAL LOADS Data ............................................................... 3-36
3.4.3. PRESCRIBED DISPLACEMENTS Data .................................. 3-37
3.4.4. DISTRIBUTED LOADS Data ................................................... 3-37
3.4.5. BODY FORCES ......................................................................... 3-37
3.4.6. COMPONENT LOADS Data .................................................... 3-37
3.5. UNITY Check Data .................................................................... 3-38
3.6. STIFFNESS MATRIX Data ....................................................... 3-41
3.7. STOP Command ......................................................................... 3-41
4. Examples ............................................................................................................ 4-1
4.1. Example of a Single Pile Analysis ............................................... 4-1
4.2. Example of a Pile Structure Interaction Analysis ....................... 4-18
4.3. Group Pile Analysis .................................................................... 4-43
4.4. Group Pile Structure Interaction ................................................. 4-55
A - Preliminary Data Block for SPLINTER .........................................................A-1
A.17.1 Global UNITS Definition ...........................................................A-15
A.17.2 Results UNITS Command ..........................................................A-16
B - Running Instructions for SPLINTER ............................................................. B-1
E.4.1 Files Required for a Soil-Pile Analysis ........................................ B-1
E.4.2 Files Required for a Soil-Pile-Structure Interaction Analysis ...... B-1
C - Valid Options for Splinter .............................................................................. C-1
D - Restarts ............................................................................................................D-1
E - Element Types for SPLINTER ....................................................................... E-1
E.4.1 OFFS Command ......................................................................... E-10
E.4.2 OFFG and OFSK Commands ..................................................... E-11
E.4.3 OFCO Command ........................................................................ E-12
F - Consistent Units.............................................................................................. F-1
G - References ......................................................................................................G-1
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. ii
SPLINTER User Manual Introduction
SPLINTER
ASAS Soil-Pile-Structure Interaction Program
1. Introduction
The SPLINTER program is part of the ASAS Finite Element Analysis System. It performs two main types of
analysis. Firstly SPLINTER may be used as a stand alone program which can analyse one or more single piles
whose loading is defined at the pile caps, and possibly at other points along the piles. The second usage of
SPLINTER is for the analysis of the interaction of an elastic structure, which is supported on one or more piles,
with an elastic or inelastic soil. In this case SPLINTER must be run as one of a sequence of runs through the
ASAS suite.
In both the isolated pile and pile structure interaction analyses, group effects due to forces transmitted from one
pile to another via the soil medium can be included.
Although SPLINTER has a number of facilities for investigating non-linear soil behaviour, the structure and
piles themselves are always assumed to be linear and elastic in their behaviour. The user may input data to
describe the lateral force-displacement, the end-bearing and skin-friction responses of the soil layers which occur
at the pile location. It is not necessary for all the piles in an analysis to be situated in identical geological strata.
The data input for SPLINTER is very similar to ASAS data; indeed many of the data blocks are common to the
two programs.
1.1. Single Pile Analysis
For analyses requiring only the behaviour of one or more piles with no structural interaction (except by way of
connections between the piles at the pile cap), SPLINTER operates as a stand alone program whose execution is
independent of ASAS. The minimum data required is that which is necessary to define the physical location of
the pile, or piles (the end coordinates), together with geometrical properties (diameter and thickness), elastic
material properties and the applied loads. Only ASAS TUBE elements and BM3D/BEAM elements with tubular
section are currently permitted. Each pile must be modelled with a single element: if the pile is of non-constant
cross-section then a stepped element should be used.
The soil material properties must be specified on a layer by layer basis. For each stratum the lateral force-
displacement curve (P-Y curve) and the skin friction force-displacement curve (T-Z curve) may be input. For
the lowest stratum the end-bearing force-displacement curve may also be defined. All of these three force-
displacement relationships are piecewise linear curves with no restriction on the number of line segments
allowed.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-1
SPLINTER User Manual Introduction
Any conditions of restraint on the pile may be specified using the standard ASAS suppressions and prescribed
displacement data. Suppressions may be applied at either the pile tip or pile cap node. It is not possible to apply
either suppressions or prescribed displacements at intermediate points on the pile.
SPLINTER utilises a restricted subset of the standard ASAS loading types which are:
a) Distributed load types BL5, BL6 and BL7.
b) Nodal loads
c) Prescribed displacements
d) Body force
Note that prescribed displacements and nodal loads may not be applied to the pile tip. However, BL5 point
loads may be utilised to apply a load at the pile tip if required.
For the initial conditions the soil stiffness, as defined by the curves for zero displacement, is added to the pile
stiffness and the displacements are calculated, assuming no change in the soil properties. These displacements
are compared with the values at which the soil force-displacement curves become non-linear. If the soil has
become non-linear, that is the force-displacement relationship is no longer on the initial part of the curve, the soil
stiffness is recalculated for the current displacement. The modified soil stiffness is added to the pile stiffness
and a new set of displacements calculated. Iteration continues in this way until the displacements calculated in
an iteration differ from those of the preceding iteration by less than a small tolerance.
These converged values of displacement are taken to be an adequate estimate of the true behaviour. The
program then prints the pile cap displacements and forces, and the pile’s displacements.
This procedure is then repeated for each load case that the user has defined. There is no theoretical limit to the
number of loadcases which may be analysed in one run.
Unity checks may be requested against the following codes of practice:
• American Petroleum Institute (API) ‘Recommended Practice for Planning, Designing and
Constructing Fixed Offshore Platforms - Working Stress Design’, RP2A-WSD, Twentieth Edition,
July 1, 1993 (the Seventeenth Edition is also supported).
• American Petroleum Institute (API) ‘Recommended Practice for Planning, Designing and
Constructing Fixed Offshore Platforms - Load and Resistance Factor Design’, RP2A-LRFD, First
Edition, July 1, 1993.
In order to calculate these, yield data must be supplied for the piles. For WSD checks, extreme environmental
loads may be specified.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-2
SPLINTER User Manual Introduction
1.2. Soil-Pile-Structure Interaction Analysis
This type of analysis is conducted by using the ASAS substructuring capabilities, which allow significant
savings to be made in overall computer time. The SPLINTER run replaces the GLOBAL STRUCTURE run of a
standard ASAS substructure analysis, as shown in Figure 1.1.
The first phase of the sequence must be to create an ASAS master component, which typically will be the
physical superstructure of the entire model. The superstructure must contain all the structural elements, with the
exception of the piles. This master component is generated in a standard ASAS component creation run. The
degrees of freedom which will later link the superstructure to the piles must be defined as LINK freedoms in the
data. The structural loading should be applied to the superstructure in the normal way.
At this point the analyst will have generated the elastic stiffness matrix of the superstructure and the associated
load vectors referred to the LINK freedoms.
The second phase is to carry out the SPLINTER run. The user defines the piles, their properties and the soil data
in an identical manner to that for the analysis of a single pile. The pile cap nodes will now connect to the LINK
nodes of the superstructure generated in the first phase. Loading may be applied to the piles as for single pile
analyses and, in addition, COMPONENT loads may be used to include the loading from the superstructure. In
addition to suppressions and prescribed displacements as restraint conditions it is also possible to apply global
freedom releases at the pile cap nodes.
The SPLINTER program will now iterate over all loadcases and all piles until each loadcase has converged to
within the desired tolerance. The iteration over each individual pile is similar to that described above for a single
pile. Convergence of the structure is only achieved when all individual piles have converged. Displacements
and reactions for each pile cap node. together with displacements and forces along the piles are reported.
Finally, if the analyst wishes to know the forces and displacements throughout the superstructure, an ASAS
STRESS RECOVERY analysis may be performed. Again this is an entirely standard ASAS analysis. The pile
cap displacements generated by the SPLINTER analysis are accessed and used to give all the displacements
within the superstructure. (This displaced shape may be plotted using FEMVIEW). Stresses are then calculated
from the element properties and displacements in the normal manner.
The flexibility of the ASAS substructure system allows any substructure to be used in any number of GLOBAL
STRUCTURE (or SPLINTER) runs. It is thus possible to generate the master component of the superstructure
once, and then use this information to investigate a substantial number of pile sizes or configurations by running
several SPLINTER analyses. The analyst only needs to perform the STRESS RECOVERY run of ASAS if the
SPLINTER run indicates satisfactory overall behaviour. Using these features the design-analysis cycle may be
performed in a rapid and economical manner.
When the component creation run has been performed on a different machine, or even a different program, the
resulting data including the stiffness matrix and loading data may be input to SPLINTER to reform the interface
data required to include the component in a structure run for the current project (see Section 2.2.4). A master
component created in this way can be subsequently used in the same way as one created by the more normal
methods except that, when stress recovery is performed, only the displacement values for the link freedoms on
that component will be output, the reactions will be zero and no stresses will be given.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-3
SPLINTER User Manual Introduction
Figure 1.1 Soil pile structure interaction
1.3. Pile Group Interaction effects
For both the isolated pile and soil-pile-structure analyses, group interaction effects may be considered. The
technique employed is based upon the calculation of soil displacements using Mindlin interaction coefficients
which assumes that the soil behaves as an elastic half space away from the plastic zone immediately adjacent to
the pile. In order that the interaction effects can be considered, additional information is required about the
stress/strain properties of the soil strata by way of elastic modulii and Poisson’s ratios for soil defined. Group
interaction is requested by including PGRP data in the data file.
Since interaction between piles within a group diminishes with increased separation, the user can choose to
either specify a maximum interaction distance beyond which no influence is calculated or allow the program
to calculate a suitable truncation value based upon embedment depths of the piles.
The piles forming the group, or groups, may either be rigidly connected at the pile cap or structurally isolated,
the program automatically generating the necessary additional information when rigid connections are requested.
Note that where pile groups are being analysed without a connecting superstructure, the node defining the pile
cap for a given group must be either connected to one of the piles within the group or have a dummy non-
structural tube element attached to it.
Group interaction effects can be particularly sensitive to changes in elastic soil properties and care must be
exercised in selecting the appropriate data for any given analysis. In addition, the following assumptions and
restrictions are applied by the program on user defined data:-
(i) Only non-zero elastic soil modulii may be defined since the Mindlin interaction effects become infinite
for zero soil modulus. If an elastic modulus increasing linearly with depth is required (representing, for
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-4
SPLINTER User Manual Introduction
example, a normally consolidated soil), it is suggested that a nominal, non-zero value is applied to the top
section of the pile.
This requirement implies that even if only lateral effects are being investigated, axial elastic properties
must be defined.
(ii) Mindlin interaction coefficients between any two piles in a group are based upon a constant value of
elastic modulus for the soil. If a non-constant soil modulus distribution is supplied by the user, the
program generates an effective value by calculating an average of the soil properties defined between any
two given points on the piles. e.g.:-
E1 A D1
d1 r
D2
E2
d2 B
Soil modulus profile Pile 1 Pile 2
The representative value used in the calculation of the interaction coefficients between node A on pile 1 and
node B on pile 2 will be given by
( + )d + d
EAV = E1 E 2 1 E 2 2
d
where d is given by
( - )+r
d = d1 + d 2 = D2 D1 x FACT
2
D1 = depth to node on pile 1
D2 = depth to node on pile 2
r = the distance between the two nodes
FACT = a factor which accounts for different behaviour in the horizontal and vertical directions
The inclusion of soil terms from below the lowest of the two nodes is to account for, albeit approximately, the
extra stiffness introduced because of the increasing nature of the modulus.
Note that different soil profiles may be defined for each of the piles within a group if required and additional
terms will be included in the above formula as required.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-5
SPLINTER User Manual Introduction
(iii) For a group analysis, SPLINTER initially carries out a partial convergence on the individual piles before
applying the group interaction. The soil displacements due to the group effect are then calculated
utilising the soil reactions from the current iteration. By default, SPLINTER carries out the soil
displacement calculation once per loadcase as repeated computation after each iteration often leads to the
analysis failing to converge because of the extra non-linearity introduced by the group interaction. If it is
required to investigate the effect of recalculating the soil displacements after the group interaction has
been included, two courses of action are available to the user.
1. Include the option RCSD on the options command in the preliminary data which allows the
recalculation of soil displacements after each iteration.
2. Include the option INCR on the options command in the preliminary data and input two or more
loadcases with the same applied loading. In this case, the soil displacements are only calculated
once per loadcase but the results from one loadcase are used as an initial condition for the next and
thus will permit a recalculation of the soil displacements for the given load (see Section 1.5)
There is no definitive statement as to which method should be adopted but, in general, the INCR option is more
likely to converge but is computationally expensive. The RCSD option should only normally be used when the
pile displacements are predominantly in the elastic regime of the soil P-Y and T-Z curves.
1.4. Automatic Pile Subdivision
As mentioned in Section 1.1, each pile must be input as a single TUBE, BM3D or BEAM element, which may
be stepped if necessary. In order to calculate the structural stiffness of the pile and the soil to a sufficient degree
of accuracy, the individual piles are automatically subdivided into a number of finite elements. Pile subdivisions
will occur where there are changes in pile cross-section, that is at the position of any steps in a stepped tube;
where there are any changes in the soil properties due to crossing from one stratum to another and at any position
where point loads are applied to the pile.
Two additional criteria are applied to the subdivision process:
(i) The subdivision length will be related to the nominal diameter of the pile multiplied by a basic
subdivision value (default 1.0) plus a percentage of the depth below the local mudline given by the
subdivision modifier (default 0.1 or 10%). The depth utilised is taken at the mid-point of the existing
subdivision.
(ii) Each subdivision will be greater than 10% of the nominal pile diameter.
Item (i) results in substantial savings in computer resources over methods employing constant section lengths
while ensuring smaller subdivisions in the bending zone adjacent to the mudline. Both the basic subdivision
value and the subdivision modifier may be specified by using the DIVISION command in the preliminary data.
(See Appendix A).
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-6
SPLINTER User Manual Introduction
It is important to note that while the automatic subdivision process will provide a satisfactory result for general
soil conditions, there are instances when user defined divisions are preferable. In particular, if only a few soil
layers have been defined then the resultant subdivisions may prove to be too coarse and provide poor lateral
displacements. It is suggested that a data check is carried out with the default divisions selected and the resultant
subdivision information inspected for large sub-elements in the critical top one third of the pile. As a rule of
thumb, the subdivisions should be less than two times the pile diameter in the critical zone
Item (ii) prevents ill conditioning due to two closely spaced points occurring in the subdivision process. Where
violation of this criterion occurs, the points are adjusted to be coincident. The program defined default cannot be
amended.
Note that the nominal diameter specified above is taken as the largest diameter supplied on a stepped tube.
1.5. Convergence criteria
The analysis process is based upon the solution of the simultaneous equations relating to the pile caps and
associated structural elements. Since, in general, the soil is of a non-linear nature the solution method utilises an
iterative technique whereby the soil stiffness and associated reactive loads are updated from the results of the
previous iteration. Successive iterations modify the soil properties with progressively smaller resultant changes
to the behaviour of the pile model. In order that the analysis will terminate within a finite number of iterations, a
convergence tolerance is applied as follows:
(i) On the first iteration the pile cap displacements and reactions are calculated and stored. Note that non-
zero reactions will only occur when some form of constraint is applied to the pile cap e.g. rigid pile cap
in a group analysis.
(ii) On the second and subsequent iterations, revised pile cap displacements and reactions are computed and
compared with the previous iteration. If the percentage difference is greater than that defined (either by
program default or user input) the revised displacements are stored and the iteration process continued.
The default convergence criteria is taken as 5%. This can be modified using the CONVERGE command
in the preliminary data. (See Appendix A).
It is suggested that a lower limit of 0.1% for single pile and 1-2% for group pile analyses is observed in order to
prevent an excessive number of iterations for convergence.
By default, after a loadcase has converged, the soil parameters are reinitialised to the unloaded state. While this
is a necessary requirement for a totally general set of loadcases, if an incremental loading study is to be carried
out it will prove computationally inefficient. In order to utilise the results from a given loadcase as a basis for
subsequent loads, the user can specify INCR in the options which preserves the converged state of the soil as the
initial condition for a following loadcase.
In addition to the convergence criteria described above, a simple divergence check is included in order to trap
numerical instabilities introduced due to multiple pile failure or highly non-linear systems. In some instances it
may be desirable to switch this facility off, especially in group analyses where interaction effects may take
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-7
SPLINTER User Manual Introduction
several iterations to stabilise. The divergence check may be overridden by including NDVC on the options
command. It is suggested that this option is included only after reference to the iteration report confirms that no
inherent instability exists. Under these circumstances, the MAXIT command should be included to prevent too
many iterations being carried out if the analysis fails to converge (See Appendix A for details of the MAXIT
command).
1.6. Soil representation
The nonlinear foundation analysis method incorporated in SPLINTER utilises a finite element representation of
the pile and soil system. Figure 1.2 illustrates a typical element representing a pile segment and associated
springs employed to model the soil.
Z
X
Y
Figure 1.2 Pile/spring foundation model
The springs utilised for the soil model are characterised by a nonlinear force-deflection relationship of the type
shown in Figure 1.3. These are commonly known as P-Y curves for lateral behaviour and T-Z curves for axial
behaviour.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-8
SPLINTER User Manual Introduction
load
deflection
Figure 1.3 Soil/load deflection characteristics
It is because of the non-linear nature of the soil properties that SPLINTER carries out an iterative solution
technique, each iteration taking an assumed, or calculated, value for the soil spring stiffness based upon the
previous iteration.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-9
SPLINTER User Manual Introduction
Two solution methods exist within SPLINTER for determining the representative soil stiffness from the defined
P-Y and T-Z curves, viz Tangent and Secant stiffness. These are shown diagramatically below:
Force Force
Kd
Kd
Pd Pd
Pp
yd Displacement yd Displacement
Tangent stiffness Secant stiffness
For both types of soil representation, the curves are stored as a series of points as defined by the user and
depicted by crosses in the diagrams above. In order that the soil stiffness may be computed, the soil properties
are assumed to vary linearly between these points as shown above. For points beyond the last y datum defined,
linear extrapolation is utilised from the last two points supplied.
In general, the tangent stiffness method will converge faster than the secant stiffness approach especially as the
pile approaches its limiting capacity. For single pile analyses the tangent stiffness method is adopted by default.
If group interaction effects are requested, the secant method is utilised since the step wise nature of the tangent
method can result in convergence problems with the extra non-linearity introduced by the soil interaction.
Both program defaults may be overridden by the user defining either TANG or SECA on the options command
in the preliminary data. (See Appendix C).
1.7. Mudslides
SPLINTER normally assumes that the soil is initially in an undisturbed state and all pile displacements are
referred to as absolute soil origin. There are instances, however, where displacement of the soil itself may occur
due to the effects of external influences such as general soil movement (mudslides) or the proximity of adjacent
structures.
The soil movement induces an additional loading on the pile, in a similar manner to that experienced by piles
within a group. The loading is a function of the relative displacement between the pile and the surrounding soil.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-10
SPLINTER User Manual Introduction
The soil displacement thus has the effect of shifting the P-Y (for horizontal slides) and T-Z (for vertical slides)
curves by an amount equal to the local soil movement.
Where such soil shifts are required, SPLINTER provides a facility to define soil displacements with respect to
the global axes thus permitting directional shifting of the curves which would not be otherwise possible for P-Y
data.
1.8. Node numbers and coordinates
Each node in the foundation idealisation must be given a unique positive integer number, so that an element can
be defined unambiguously by the node numbers at its ends. If the model has N nodes, the node numbers need
not necessarily be within the range 1 to N, gaps in the numbering are permitted.
The coordinates defining the geometry of the elements may be supplied in any convenient rectangular cartesian,
cylindrical polar or spherical polar coordinate system. A foundation model may use several of these coordinate
systems. See Figure 1.4 for details. In general, the coordinates must be supplied for all nodes on the structure.
If a pile-soil interaction analysis is being carried out, however, nodes which appear in the component topology
data (Section 3.2.7) need not have their coordinates supplied since these will be extracted from the appropriate
backing files.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-11
SPLINTER User Manual Introduction
Coordinates for Cartesian Systems
X Distance from the local origin in the local X’ direction
Y Distance from the local origin in the local Y’ direction
Z Distance from the local origin in the local Z’ direction
Coordinates for Cylindrical Polar Systems
R Distance from the local origin in the local X’Y’ plane.
θ Angle from the +ve side of the local X’ axis in the local X’Y’ plane
(+ve for right-hand screw rule applied to +ve local Z’).
Z Distance from the local origin in the local Z’ direction.
Coordinates for Spherical Polar Systems
R Distance from the local origin in 3-D.
θ Angle from the +ve side of the local X’ axis in the local
X’Y’ plane (+ve for right-hand screw rule applied to +ve local Z’).
ø Angle from the +ve side of the local Z’ axis to the radius,
measured in 3-D.
Figure 1.4
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-12
SPLINTER User Manual Introduction
1.9. Global and Local Axis Systems
Regardless of the systems used to define coordinates, the displacement freedoms within SPLINTER are usually
referred to the global axis system. This is a right-handed rectangular cartesian (X,Y,Z) system. In some cases
the global axis system is replaced for selected nodes or elements by a local axis system. There are three broad
types of these: coordinate local axes, element local axes and nodal local axes. The latter are known as ‘skew
systems’.
1.9.1. Coordinate Local Axes
Coordinate local axes are used to define the positions of nodes in space. Any required combination of cartesian,
cylindrical polar or spherical polar systems may be used; all of them are transformed to the global system within
the program. For each local system, the user provides the origin and the direction cosines relative to the global
system. Coordinates may, of course, be entered directly in the global system if required.
1.9.2. Element Local Axes
The tube elements available in SPLINTER have their own local axes. These are used for the definition of
element loads and stress results. The direction of the element local axes is defined by the order of the nodes on
the elements. Full details are given in the relevant element description sheets in Appendix E.
1.9.3. Skew Systems
Skew systems, can be used for two purposes
(i) To specify suppressions, prescribed displacements, or constrained freedoms in directions other than those
of the global axis system. All output of displacements and reactions is related to this new axis system.
Only one such skew system is permitted at a node.
(ii) To specify nodal loads in a direction other than the reference system, where the reference system is with
the global system or the global system as modified by a skew system defined in (i). For example, if a
node is skewed to allow a skew suppression, and a nodal load is required in the global direction, then a
further skew system is required to re-skew the load back to the global system. Nodal loads applied with a
skew system are transformed to their components in the reference system described above. The axis
system at the node is not altered and hence any number of skew systems may be applied to loads at a
node to accommodate various skewed nodal loads.
Each skew system is defined by a unique integer number - the skew integer. The same skew system may be
referred to in several places in the data.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-13
SPLINTER User Manual Introduction
The relationship of coordinate local axes or skew systems to the global system is given by the direction cosines
of their axes relative to the global axes. Each direction cosine gives the projection of a unit vector along the
skew axis onto the global axis. Skew systems must be right-handed and orthogonal.
It is only necessary to specify two of the axes: the third is computed automatically. If X’, Y’, Z’ represent the
skew axes, and X,Y,Z the global axes, ASAS requires the six direction cosines:
X’X, X’Y, X’Z, Y’X, Y’Y, Y’Z
where, for example, X’X is the projection onto the global X axis of a unit vector along the skew X’ axis.
1.10. Results from Splinter
In addition to displacements, reactions, stresses or other results, SPLINTER produces a list of data and useful
intermediate information. The printing of these lists is controlled by the options which are detailed in Appendix
C.
1.10.1. Data Echo
SPLINTER normally prints the image of each data card as it is read. However, by setting the appropriate control
options, this printing can be suppressed for all except specified data blocks. Data lines which are found to be in
error are printed with an appropriate error message.
1.10.2. Expanded Data and Summaries
SPLINTER normally prints a complete list of expanded and cross referenced data. By setting the appropriate
control options, only selected summaries are printed.
1.10.3. Results - Displacements and Reactions
The displacement printing is in three parts
(i) During the iteration stage of the program, pile cap displacements and reactions will be printed together
with the convergence parameters being monitored. See Figure 1.5. Note that non-zero reactions at a node
will only occur if a constraint or rigid pile cap has been assigned to that node.
(ii) Displacements and reactions for all the nodes on the structure (excluding the nodes defining the bottom of
the piles) for all load cases are printed in stage 6. Up to five load cases of results are printed side by side
on a page; further sets of results follow immediately after the first set. See Figure 1.6.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-14
SPLINTER User Manual Introduction
The displacements and reactions will be in the global coordinate system unless a restraint has been
applied at a node in a skew direction in which case the results at that node are in the skew direction.
(iii) A detailed report of the global displacements down the piles is also printed in stage 6. If a skew system is
operative at either or both ends of the pile, the results at these ends will be in the skew direction(s). At all
other points in between, the global system will be applicable. See Figure 1.7. By default, the results will
be printed load case by load case. If the user requires all the results for one pile element to be printed
together, the option BYEL should be used.
1.10.4. Results - Forces and Stresses
This is divided into two parts
(i) If non-pile elements exist in the analysis i.e. tubes assigned a soil integer of zero, the forces are listed for
one loadcase at a time for all non pile elements (see note on BYEL below). See Figure 1.8.
(ii) For each pile element, a detailed report providing both forces and axial, bending and combined stresses
are printed for all the subdivisions down the pile. The combined stress is calculated as the sum of the
absolute values of axial and biaxial bending stresses and adopts the sign of the axial stress. Optional
utilisation check results may also be reported if the UNCK data is supplied. See Figure 1.9.
By default, the results will be printed load case by load case. If the user requires all the results for one
pile element to be printed together, the option BYEL should be used.
1.10.5. Results Pile Cap Stiffness
The pile cap stiffness at a pile cap node may be extracted by specifying option PSTF. This will enable the
following data to be written to a formatted output file for each pile cap node:
1. ASAS coordinates data of the pile cap node
2. ASAS link freedoms data of the pile cap node
3. Pile cap stiffness in packed symmetric format as required for the stiffness data in an ASAS direct stiffness
input job.
There is a separate stiffness file generated for each pile top node for each load case. Note that if a rigid pile cap
is used (i.e. CONN in PGRP command), the stiffness at the top of each pile in the group will be output separately
rather than a single stiffness at the rigid pile cap node.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-15
SPLINTER User Manual Introduction
The pile cap stiffness file created is called ssssNnnnnnnLmmmm.STF, where ssss is the name on the
STRUCTURE command in the preliminary data, nnnnnn is the six digit node number of the pile cap node and
mmmm is the 4 digit load case number. For example, if the structure is called ABCD, the pile cap is 100 and the
load case is 20, the stiffness file name will be ABCDN000100L0020.STF.
The pile cap stiffness can be imported into an ASAS analysis as a component by carrying out a direct stiffness
input job (JOB STIF) in ASAS. As the pile cap stiffness values are written in the same format as required for
the definition of component stiffness, these can be easily incorporated into the JOB STIF data using the @ file
facility.
SPLINTER offers two methods to represent the soil stiffness, namely tangent and secant stiffness. It is assumed
that the extracted pile cap stiffness will correspond to the stiffness employed in the solution. While both models
should produce very similar stiffness in small deformations, it should be noted that they will start to deviate as
the pile load increases.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-16
SPLINTER User Manual Introduction
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-17
l
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
SPLINTER User
PILE CAP DISPLACEMENTS AND REACTIONS ITERATION REPORT
LOAD CASE NO. 1 ITERATION 3
------------------ -------------
RESULTANT PERCENTAGE RESULTANT PERCENTAGE
NODE FD DISPLACEMENT REACTION DISPLACEMENT CHANGE REACTION CHANGE
---- -- ------------ ----------- ------------ ---------- ----------- ----------
201 X 5.6420D-03 0.0000D+00
Y 2.6922D-03 0.0000D+00 9.8254D-03 1.4793D-04 0.0000D+00 0.0000D+00
Z 7.5801D-03 0.0000D+00
RX -7.0222D-04 0.0000D+00
RY 1.2519D-03 0.0000D+00 1.4548D-03 -3.6428D-04 0.0000D+00 0.0000D+00
RZ -2.3649D-04 0.0000D+00
203 X 6.4403D-03 0.0000D+00
Y -2.8300D-03 0.0000D+00 1.1741D-02 -1.7730D-04 0.0000D+00 0.0000D+00
Z -9.3999D-03 0.0000D+00
RX 1.0177D-03 0.0000D+00
RY 1.1315D-03 0.0000D+00 1.5422D-03 -2.8301D-04 0.0000D+00 0.0000D+00
RZ -2.4967D-04 0.0000D+00
207 X 7.6872D-04 0.0000D+00
Y 2.9059D-03 0.0000D+00 5.9815D-03 3.8970D-04 0.0000D+00 0.0000D+00
Z 5.1713D-03 0.0000D+00
RX -5.7170D-04 0.0000D+00
RY 4.0109D-04 0.0000D+00 8.8824D-04 4.7826D-04 0.0000D+00 0.0000D+00
RZ -5.4887D-04 0.0000D+00
209 X 8.1005D-04 0.0000D+00
Y -2.6932D-03 0.0000D+00 8.6459D-03 -2.5177D-06 0.0000D+00 0.0000D+00
Z -8.1757D-03 0.0000D+00
RX 2.2063D-05 0.0000D+00
RY -1.1532D-04 0.0000D+00 6.0717D-04 1.8424D-04 0.0000D+00 0.0000D+00
RZ -5.9571D-04 0.0000D+00
LOADCASE CONVERGED AFTER 3 ITERATIONS
SECTION 1 COMPLETED
Introduction
Page 1-18
Figure 1.5 Iteration Report
l
LOAD CASE 1 LOAD CASE 2
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates -------------- --------------
SPLINTER User
NODE FD SKW DISPLACEMENT REACTION DISPLACEMENT REACTION
---- -- --- ------------ -------- ------------ --------
1 X 8.3574D-03 2.795D+01 7.2685D-03 2.758D+01
Y 5.6433D-04 3.616D-01 1.6533D-03 4.498D-01
Z -3.3536D-03 -1.722D+02 -7.0671D-03 -3.645D+02
RX -1.8351D-05 3.291D+00 -1.0779D-04 -2.062D+01
RY 1.0868D-04 -2.937D+02 1.9235D-05 -3.160D+02
RZ -4.6166D-05 -2.385D+00 -4.6166D-05 -2.385D+00
3 X 8.6344D-03 1.858D+01 7.5455D-03 1.891D+01
Y 2.8734D-04 -1.229D+00 1.3763D-03 -1.561D+00
Z -4.1158D-03 -1.908D+02 -7.8293D-03 -3.558D+02
RX -1.8351D-05 -1.338D+01 -1.0779D-04 -3.987D+01
RY 1.0868D-04 -2.212D+02 1.9235D-05 -2.477D+02
RZ -4.6166D-05 -2.385D+00 -4.6166D-05 -2.385D+00
5 X 8.9114D-03 2.911D+01 7.8225D-03 2.903D+01
Y 1.0338D-05 -2.494D+00 1.0993D-03 -2.130D+00
Z -4.8780D-03 -2.630D+02 -8.5915D-03 -4.553D+02
RX -1.8351D-05 -2.795D+01 -1.0779D-04 -5.028D+01
RY 1.0868D-04 -3.114D+02 1.9235D-05 -3.353D+02
RZ -4.6166D-05 -2.385D+00 -4.6166D-05 -2.385D+00
7 X 8.9114D-03 2.436D+01 7.8225D-03 2.448D+01
Y 5.6433D-04 3.361D+00 1.6533D-03 3.241D+00
Z -3.5739D-03 -1.740D+02 -8.3607D-03 -4.243D+02
RX -1.8351D-05 2.666D+01 -1.0779D-04 1.369D+00
RY 1.0868D-04 -2.745D+02 1.9235D-05 -2.998D+02
RZ -4.6166D-05 -2.385D+00 -4.6166D-05 -2.385D+00
10 X 8.7268D-03 0.000D+00 7.6378D-03 0.000D+00
Y 3.7967D-04 0.000D+00 1.4686D-03 0.000D+00
Z -3.9352D-03 0.000D+00 -8.0064D-03 0.000D+00
RX -1.8351D-05 0.000D+00 -1.0779D-04 0.000D+00
RY 1.0868D-04 0.000D+00 1.9235D-05 0.000D+00
RZ -4.6166D-05 0.000D+00 -4.6166D-05 0.000D+00
11 X 9.8135D-03 0.000D+00 7.8301D-03 0.000D+00
Y 5.6318D-04 0.000D+00 2.5466D-03 0.000D+00
Introduction
Z -3.9352D-03 0.000D+00 -8.0064D-03 0.000D+00
Page 1-19
RX -1.8351D-05 0.000D+00 -1.0779D-04 0.000D+00
RY 1.0868D-04 0.000D+00 1.9235D-05 0.000D+00
RZ -4.6166D-05 0.000D+00 -4.6166D-05 0.000D+00
Figure 1.6 Node Displacement and Reaction Report
l
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
SPLINTER User
GLOBAL PILE DISPLACEMENTS
-------------------------
ELEMENT NUMBER 1 PILE CAP NODE 1 LOAD CASE 1 EXTREME WAVE LOAD
CASE --------------------- PILE TIP NODE 2 ---------------
DISTANCE FROM
PILE CAP X Y Z RX RY RZ
------------- ----------- ----------- ----------- ----------- ----------- -----------
0.0000 5.8068D-01 3.1361D-01 -2.0387D-03 -2.4565D-02 4.9296D-02 0.0000D+00
5.0000 3.4370D-01 1.9056D-01 -1.7061D-03 -2.3019D-02 4.3129D-02 0.0000D+00
10.0000 1.5817D-01 8.9661D-02 -1.4206D-03 -1.6632D-02 3.0159D-02 0.0000D+00
15.0000 4.3522D-02 2.5763D-02 -1.1804D-03 -9.0628D-03 1.6092D-02 0.0000D+00
20.0000 -7.2890D-03 -3.1874D-03 -9.8130D-04 -3.2162D-03 5.5419D-03 0.0000D+00
25.0000 -1.8578D-02 -1.0024D-02 -8.1606D-04 -1.8183D-04 1.7504D-04 0.0000D+00
30.0000 -1.3919D-02 -7.7193D-03 -6.7898D-04 7.4730D-04 -1.4065D-03 0.0000D+00
35.0000 -6.7426D-03 -3.8180D-03 -5.6535D-04 6.9333D-04 -1.2580D-03 0.0000D+00
40.0000 -1.8844D-03 -1.1126D-03 -4.7123D-04 3.8592D-04 -6.8599D-04 0.0000D+00
45.0000 2.7478D-04 1.1645D-04 -3.9338D-04 1.3688D-04 -2.3613D-04 0.0000D+00
50.0000 7.6558D-04 4.1266D-04 -3.2911D-04 9.2174D-06 -1.0214D-05 0.0000D+00
55.0000 5.8076D-04 3.2194D-04 -2.7621D-04 -3.0534D-05 5.7562D-05 0.0000D+00
60.0000 2.8404D-04 1.6075D-04 -2.3283D-04 -2.8832D-05 5.2341D-05 0.0000D+00
65.0000 8.0944D-05 4.7702D-05 -1.9750D-04 -1.6204D-05 2.8817D-05 0.0000D+00
70.0000 -1.0281D-05 -4.1917D-06 -1.6898D-04 -5.8312D-06 1.0071D-05 0.0000D+00
75.0000 -3.1685D-05 -1.7065D-05 -1.4630D-04 -4.6700D-07 5.7310D-07 0.0000D+00
80.0000 -2.4512D-05 -1.3584D-05 -1.2866D-04 1.2334D-06 -2.3309D-06 0.0000D+00
85.0000 -1.2294D-05 -6.9554D-06 -1.1547D-04 1.2083D-06 -2.1952D-06 0.0000D+00
90.0000 -3.4778D-06 -2.0508D-06 -1.0627D-04 7.5679D-07 -1.3473D-06 0.0000D+00
95.0000 1.5469D-06 7.9699D-07 -1.0073D-04 4.4838D-07 -7.8495D-07 0.0000D+00
100.0000 4.8970D-06 2.7197D-06 -9.8672D-05 3.6238D-07 -6.3010D-07 0.0000D+00
TOTAL GLOBAL SOIL REACTIONS FOR ELEMENT 1 X Y Z
3.1650D+03 2.0760D+03 -2.4360D+03
Figure 1.7 Pile Displacement Report
Introduction
Page 1-20
l
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
SPLINTER User
MEMBER FORCE AND STRESS REPORT
NODE AXIAL BENDING COMBINED
ELEMENT LOAD NO. FORCE XX SHEAR QY SHEAR QZ TORQUE XX MOMENT YY MOMENT ZZ STRESS STRESS STRESS
---------- ---- ----- ----------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- -----------
200 TUBE 1 1 65.2000 -29.0000 50.6000 0.0000 -2530.0000 1450.0000 43.138 2880.415 2923.554
101 65.2000 -29.0000 50.6000 0.0000 0.0000 0.0000 43.138 0.000 43.138
201 TUBE 1 3 73.1000 -29.0000 78.2000 0.0000 -3910.0000 1450.0000 48.365 4119.231 4167.596
103 73.1000 -29.0000 78.2000 0.0000 0.0000 0.0000 48.365 0.000 48.365
202 TUBE 1 5 69.9000 -40.0000 50.6000 0.0000 -2530.0000 2000.0000 46.248 3185.622 3231.870
105 69.9000 -40.0000 50.6000 0.0000 0.0000 0.0000 46.248 0.000 46.248
203 TUBE 1 7 20.8000 -40.0000 78.2000 0.0000 -3910.0000 2000.0000 13.762 4338.140 4351.902
107 20.8000 -40.0000 78.2000 0.0000 0.0000 0.0000 13.762 0.000 13.762
999 TUBE 1 10 4.5475D-13 5.6843D-14 4.5475D-13 -7.1054D-14 -3.8654D-12 -1.1369D-13 3.009D-13 3.820D-12 4.121D-12
11 4.5475D-13 5.6843D-14 4.5475D-13 -7.1054D-14 4.5475D-12 -1.3642D-12 3.009D-13 4.690D-12 4.991D-12
Figure 1.8 Element Force Report
Introduction
Page 1-21
l
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates PILE FORCE AND STRESS REPORT
SPLINTER User
RESULTS UNITS KILONEWTONS METRES RADIANS
PILE FORCE AND STRESS REPORT
ELEMENT NUMBER 1 PILE CAP NODE 1 LOAD CASE 1 EXTREME WAVE LOAD CASE
--------------------- PILE TIP NODE 2 (OPERATING)
DISTANCE FROM AXIAL BENDING COMBINED API LRFD
PILE CAP FORCE XX SHEAR QY SHEAR QZ TORQUE XX MOMENT YY MOMENT ZZ STRESS STRESS STRESS UNCK
---------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- ----------
0.000D+00 -2.4360D+03 2.0760D+03 3.1650D+03 0.0000D+00 1.5820D+03 -2.2730D+03 -1.4300D+04 5.5901D+04 -7.0200D+04 1.303D-01
5.000D+00 -2.1058D+03 1.2143D+03 1.7125D+03 0.0000D+00 1.3695D+04 6.1023D+03 -1.2361D+04 3.0264D+05 -3.1500D+05 6.919D-01
1.000D+01 -1.7936D+03 2.9977D+02 2.8528D+02 0.0000D+00 1.8430D+04 9.7202D+03 -1.0529D+04 4.2059D+05 -4.3112D+05 9.602D-01
1.500D+01 -1.4957D+03 -4.0984D+02 -8.4016D+02 0.0000D+00 1.6414D+04 9.0279D+03 -8.7798D+03 3.7814D+05 -3.8692D+05 8.629D-01
2.000D+01 -1.2414D+03 -7.2842D+02 -1.3428D+03 0.0000D+00 9.7185D+03 5.4543D+03 -7.2873D+03 2.2496D+05 -2.3224D+05 5.135D-01
2.500D+01 -1.0300D+03 -5.2147D+02 -9.3762D+02 0.0000D+00 3.5753D+03 2.0618D+03 -6.0463D+03 8.3310D+04 -8.9356D+04 1.904D-01
3.000D+01 -8.5417D+02 -2.4351D+02 -4.2855D+02 0.0000D+00 3.4231D+02 2.3964D+02 -5.0141D+03 8.4347D+03 -1.3449D+04 1.957D-02
3.500D+01 -7.0782D+02 -6.2780D+01 -1.0489D+02 0.0000D+00 -7.1026D+02 -3.7331D+02 -4.1550D+03 1.6197D+04 -2.0352D+04 3.716D-02
4.000D+01 -5.8590D+02 1.4460D+01 3.0255D+01 0.0000D+00 -7.0659D+02 -3.8816D+02 -3.4393D+03 1.6273D+04 -1.9713D+04 3.725D-02
4.500D+01 -4.8421D+02 3.0065D+01 5.5470D+01 0.0000D+00 -4.0772D+02 -2.2871D+02 -2.8424D+03 9.4365D+03 -1.2279D+04 2.162D-02
5.000D+01 -3.9923D+02 2.1776D+01 3.9172D+01 0.0000D+00 -1.5189D+02 -8.7511D+01 -2.3435D+03 3.5385D+03 -5.8820D+03 8.141D-03
5.500D+01 -3.2803D+02 1.0268D+01 1.8081D+01 0.0000D+00 -1.5993D+01 -1.0954D+01 -1.9256D+03 3.9129D+02 -2.3169D+03 9.435D-04
6.000D+01 -2.6816D+02 2.7066D+00 4.5339D+00 0.0000D+00 2.8925D+01 1.5170D+01 -1.5742D+03 6.5929D+02 -2.2334D+03 1.537D-03
6.500D+01 -2.1755D+02 -5.5892D-01 -1.1838D+00 0.0000D+00 2.9346D+01 1.6112D+01 -1.2770D+03 6.7578D+02 -1.9528D+03 1.563D-03
7.000D+01 -1.7444D+02 -1.2405D+00 -2.2907D+00 0.0000D+00 1.7087D+01 9.5808D+00 -1.0240D+03 3.9543D+02 -1.4195D+03 9.159D-04
7.500D+01 -1.3736D+02 -9.0753D-01 -1.6333D+00 0.0000D+00 6.4390D+00 3.7064D+00 -8.0634D+02 1.4997D+02 -9.5631D+02 3.509D-04
8.000D+01 -1.0502D+02 -4.2740D-01 -7.5295D-01 0.0000D+00 7.5429D-01 5.0544D-01 -6.1650D+02 1.8328D+01 -6.3483D+02 4.707D-05
8.500D+01 -7.6308D+01 -1.0563D-01 -1.7638D-01 0.0000D+00 -1.0906D+00 -5.6753D-01 -4.4794D+02 2.4816D+01 -4.7275D+02 5.936D-05
9.000D+01 -5.0227D+01 3.5450D-02 7.0700D-02 0.0000D+00 -1.0095D+00 -5.5091D-01 -2.9484D+02 2.3214D+01 -3.1806D+02 5.412D-05
9.500D+01 -2.5881D+01 5.5091D-02 1.0095D-01 0.0000D+00 -3.8357D-01 -2.1303D-01 -1.5193D+02 8.8565D+00 -1.6078D+02 2.051D-05
1.000D+02 -1.7764D-15 0.0000D+00 -3.1919D-16 0.0000D+00 0.0000D+00 0.0000D+00 -1.0428D-14 0.0000D+00 -1.0428D-14 0.000D+00
MAXIMUM UTILISATION FACTOR (API LRFD ED1) OF 0.96 OCCURS AT DISTANCE 1.0000D+01
AXIAL PILE CAPACITY SAFETY FACTOR 4.6700D+00 (COMPRESSION)
Figure 1.9 Pile Force and Stress Report
Introduction
Page 1-22
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
Page 23
SPLINTER User Manual Introduction
1.11. Data Units
The user is free to choose any system of units for his data. Free format input will allow an explicit definition of
units for the analysis which can be locally overridden within each of the data blocks (where appropriate).
The basic global units to be employed are defined in the Preliminary data using the UNITS command (see
Section A.17) where the units of force and length are supplied. (Time is assumed to be in seconds). These basic
units will be utilised as the default input and results units.
In order to facilitate the use of different units for various data, a UNITS command can be used within the main
body of the data to locally override the basic units defined in the Preliminary data. This facility enables each
data block to have one or more different sets of data units which may or may not be the same as the global
definitions.
1.12. Outline of this Manual
In order to simplify this document and reduce duplication, only those data types which are unique to SPLINTER
are described in detail. Data types which are common to both ASAS and SPLINTER are cross-referenced with
the appropriate section in the ASAS manual. Where particular limitations or amendments are imposed for a
SPLINTER analysis, these will be highlighted under the appropriate data type in this manual.
Note
By default the program assumes free format input has been adopted. If fixed format (card image) data is used,
the FIXD option must be included in the OPTIONS list. It is not permissible to mix free format with fixed
format data where both types exist. Fixed format data, whilst still acceptable to SPLINTER is no regarded as
obsolete.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-24
SPLINTER User Manual Introduction
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 1-25
SPLINTER User Manual Data Formats
2. Data Formats
2.1. Free format syntax
2.1.1. General Principals
The input data for SPLINTER are specified according to syntax diagrams similar to that shown below. The
conventions adopted are described in the following pages. Detailed descriptions for each of the data blocks can
be found in Section 2 of this Manual, or where appropriate, Section 5 of the ASAS User Manual.
HEADER
KEYWORD (alpha) /integer/
KEYWORD1
real //integer//
KEYWORD2
integer KEYWORD3 real
END
Each data block commences with a compulsory header line and terminates with an END command which delimit
the information from the other data. The sequence of the input data follows the vertical line down the left hand
side of the page. If a data block can be omitted, this will be indicated as shown below.
HEADER
END
Within each data block, each horizontal branch represents a possible input instruction. Input instructions are
composed of keywords (shown in upper-case), numerical values or alphanumerics (shown in lower-case
characters), and special symbols. Each item in the list is separated from each other by a comma or one or more
blank spaces.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-1
SPLINTER User Manual Data Formats
A single line of data must not be longer than 80 characters.
Numerical values have to be given in one of two forms:
(i). If an integer is specified a decimal point must not be supplied.
(ii). If a real is specified the decimal point may be omitted if the value is a whole number.
Exponential formats may be utilised where real numbers are required.
for example 0.004 4.0E-3 4.0D-3 are equivalent
similarly 410.0 410 4.10E2 are the same.
Alphanumeric strings must begin with a letter (A-Z). The letters A-Z can be supplied in upper or lower case but
no distinction is made between the upper and lower case form. Hence “A” is assumed identical with “a”, “B”
with “b” and so on.
For example BM3D are all permissible alphanumeric strings
BL5
ALL
Also COMB are all identical
Comb
comb
However 3BMD
5BL
are examples of inadmissible alphanumeric strings.
Alphanumeric strings must not include any special symbols (see below)
If certain lines are optional, these are shown by an arrow which bypasses the line(s)
keyw ord integer
In order to build up a data block, a line or series of lines may be repeated until the complete set has been defined.
These are shown by an arrow which loops back.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-2
SPLINTER User Manual Data Formats
HEADER
real integer
END
Some data lines require an integer or real list to be input whose length is variable. This is shown by a horizontal
arrow around the list variable.
real integer
Where one or more possible alternative items may appear in the list, these are shown by separate branches for
each
KEYWORD1
integer
integer KEYWORD2
KEYWORD3 real
An optional item in a line will be enclosed in brackets e.g.
KEYWORD (alpha) integer
The relevant data block description will detail the default value adopted if the item is omitted.
An input line must not be longer than 80 characters. Certain input instructions may extend onto continuation
lines. Where this is allowable, the syntax diagram line is shown ending with an arrow. See Section 2.1.2.
KEYWORD integer
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-3
SPLINTER User Manual Data Formats
2.1.2. Special Symbols
The following is a list of characters which have a special significance to the SPLINTER input.
* An asterisk is used to define the beginning of a comment, whatever follows on the line will not be
interpreted. It may appear anywhere on the line, any preceding data will be processed as normal. For
example
(i) * THIS IS A COMMENT FOR THE WHOLE LINE
(ii) X Y RZ 1 16 24 27 *support conditions at ground level*
’ single quotes are used to enclose some text strings which could contain otherwise inadmissible characters.
The quotes are placed at each end of the string. They may also be used to provide in-line comments
between data items on a given line.
For example
BM3D ’NODES’ 1 2 ’GEOM PROP’ 5
, A comma or one or more consecutive blanks will act as a delimiter between items in the line.
For example
5, 10, 15 is the same as 5 10 15
Note that two commas together signify that an item has been omitted. This may be permissible for
certain data blocks.
For example
5,, 15 is the same as 5 0 15
Unless otherwise stated in the section describing the data block omitted numerical values are zero.
: A colon at the start of the line signifies that the line is a continuation from the previous line.
For example
5 is the same as 5 10 15
: 10
: 15
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-4
SPLINTER User Manual Data Formats
Note that this facility is only available in certain data blocks. See the appropriate description of each data
block for details.
2.1.3. Repeat Facilities
Lists of regular data can often be shortened by use of a repeat facility. A block of one or more lines of data may
be identified by a delimiter character (/) and terminated by a repeat command (RP). The repeat command
contains information on how many times the set of lines of data is to be generated and how the data is to be
incremented for each generation. The general form is:
/
KEYWORD real /integer/
RP nrep incr
/ : the delimiter character to identify the start of the data to be generated. It must be on a line of
its own.
KEYWORD : items notenclosed within slashes will be repeatedwithout any increment for generateddata
real
/integer/ : an item enclosed by / characters indicates data which may be modified using the repeat facility.
The / characters must not appear in the actual data.
RP : command word to identify the end of the data to be generated.
nrep : number of times the set of lines is to be generated, including the original data line(s).
incr : the increment to be added to certain data items for the second and subsequent generated blocks.
(The first block corresponds to the original data)
For example, suppose the data format is specified as
KEYWORD /integer/
It is required to generate integers 1, 6, 11, 16, 21, 26, 31, 36, 41, 46. If the keyword is ALL the data could be
ALL 1 6 11 16 21 26 31 36 41 46
or
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-5
SPLINTER User Manual Data Formats
ALL 1
ALL 6
ALL 1
.
.
.
ALL 46
Using the repeat facility, the following examples all produce identical data
(i) /
ALL 1
RP 10 5
or
(ii) /
ALL 1 6
RP 5 10
or
(iii) /
ALL 1
ALL 6
RP 5 10
2.1.4. Re-Repeat Facilities
The repeat facility can be extended to include a double repeat whereby data which has been expanded by use of
the RP command may be repeated again with different increment values. The general form is
//
/
KEYWORD real //integer//
RP nrep incr
RRP nrrep incr2
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-6
SPLINTER User Manual Data Formats
// : identifies the start of the data to be re-repeated. It must precede a / line
/ : identifies the start of the data to be repeated.
KEYWORD : items not enclosed within slashes will be repeated without any increment for generated
real data.
//integer// : an item enclosed by // characters indicates data which may be modified using the re-repeat or
repeat facility. The // characters must not appear in the actual data.
RP : identifies the end of the data to be generated with the repeat facility.
nrep : number of times the block of data is to be generated, including the original data line(s)
incr1 : the increment to be added to the data items for the second and subsequent generated blocks.
(The first block corresponds to the original data)
RRP : identifies the end of the data to be generated with the re-repeat facility.
nrrep : the number of times the expanded data from the repeat block is to be further generated,
including the original repeat block
incr2 : the increment to be added to each of the expanded data items for the second and subsequent re-
generated blocks. (The first block corresponds to the expanded data items)
For example, taking the previous example in Section 2.1.3, if the data syntax was specified as
KEYWORD //integer//
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-7
SPLINTER User Manual Data Formats
Then the data could be
//
/
ALL 1
RP 5 10 generates 1, 11, 21, 31, 41
RRP 2 5 generates 6, 16, 26, 36, 46
Note, the order of the numbers generated by this example in Section 2.1.3 using RP and in Section 2.1.4 using
RP and RRP is different. This may be important in a few cases where the order of the data supplied matters, for
example, user element numbers.
2.2. Data requirements for each type of analysis
The following diagrams outline the data required in order to carry out the various types of analysis in
SPLINTER:
(i) Single pile
(ii) Group pile
(iii) Pile-structure interaction
(iv) Component creation from stiffness input data
Within each analysis type, some of the data are optional and may be omitted if not required (see syntax
conventions, Section 2.1)
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-8
SPLINTER User Manual Data Formats
2.2.1. Single pile
SYSTEM DATA AREA memory
PROJECT pname
JOB (status) PILE
FILES fname
TITLE title
TEXT text
MAXIT numit
CONVERGE conval
DIVISION value1 value2
OPTIONS option
RESTART first last
GOTP xcoord ycoord zcoord
SAVE name (FILES)
END
COOR
CART (name)
CYLI
name (units)
SPHE
DCOS x'x x'y x'z y'x y'y y'z
ORIG xorigin yorigin zorigin
// node // // x // // y // // z //
FIN
END
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-9
SPLINTER User Manual Data Formats
Single Pile Data (Cont.)
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-10
SPLINTER User Manual Data Formats
Single Pile Data (Cont.)
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-11
SPLINTER User Manual Data Formats
Single Pile Data (Cont.)
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-12
SPLINTER User Manual Data Formats
Single Pile Data (Cont.)
UNCK
UNITS unitnm
ED17
(W SD) ED20
LRFD ED1
ELEM
YIEL value STEP stepno number
PROP
EXTR loadno
END
STOP
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-13
SPLINTER User Manual Data Formats
2.2.2. Group Pile Data
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-14
SPLINTER User Manual Data Formats
Group Pile Data (Cont.)
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-15
SPLINTER User Manual Data Formats
Group Pile Data (Cont.)
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-16
SPLINTER User Manual Data Formats
Group Pile Data (Cont.)
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-17
SPLINTER User Manual Data Formats
Group Pile Data (Cont.)
UNCK
UNITS unitnm
ED17
(W SD) ED20
LRFD ED1
ELEM
YIEL value STEP stepno number
PROP
EXTR loadno
END
STOP
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-18
SPLINTER User Manual Data Formats
2.2.3. Pile-structure Interaction Data
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-19
SPLINTER User Manual Data Formats
Pile-structure Interaction Data (Cont.)
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-20
SPLINTER User Manual Data Formats
Pile-structure Interaction Data (Cont.)
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-21
SPLINTER User Manual Data Formats
Pile-structure Interaction Data (Cont.)
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-22
SPLINTER User Manual Data Formats
Pile-structure Interaction Data (Cont.)
UNCK
UNITS unitnm
ED17
(WSD) ED20
ED21
LRFD ED1
ELEM
YIEL value STEP stepno number
PROP
EXTR loadno
END
STOP
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-23
SPLINTER User Manual Data Formats
2.2.4. Stiffness Input Data
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-24
SPLINTER User Manual Data Formats
Stiffness Input Data (Cont.)
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-25
SPLINTER User Manual Data Formats
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 2-26
SPLINTER User Manual Data Description
3. Data Description
The subheadings of this section of the manual have been selected to coincide with the corresponding
subheadings of Section 5 of the ASAS User Manual. The following points should be noted.
The PILE data block replaces the ELEM data block, and hence individual finite elements cannot appear in
SPLINTER. (This may be circumvented by assembling all required elements into the master component
generated to represent the superstructure).
(a) Only static analyses are permitted. As the SPLINTER run replaces the GLOBAL STRUCTURE analysis
of ASAS. LINK data are only allowed in a Stiffness Input run. MAST data must not be used.
(b) Only five types of loading are permitted: Distributed Loads (BL5, BL6 and BL7), Component Loads,
Nodal Loads, Body Forces and Prescribed Displacements. The other ASAS load types, ie. Pressure,
Temperature, Temperature Gradient, Centrifugal Load and Angular Acceleration Loads are not allowed.
These loads can, however, appear in an ASAS master component creation analysis used to generate the
superstructure.
(c) Since neither dynamic analyses, nor Centrifugal and Angular Acceleration Loads are not permitted in a
SPLINTER run, there is no requirement to input added mass directly and hence DIREct input data are not
allowed.
(d) Unity check values will only be output when yield and optionally extreme loadcase data is provided by
means of an UNCK data block. When the UNCK data block is present, a UNITS command must also be
given in the preliminary data.
3.1. Preliminary Data
The preliminary data is described in Appendix A of this Manual.
3.2. Structural Data
3.2.1. UNITS Command for Structural Data
If global units have been defined using the UNITS command in the Preliminary data (Appendix A.17), it is
possible to override the input units locally to each data block by the inclusion of a UNITS command. The local
units are only operational for the data block concerned and will return to the default global units when the next
data block is encountered.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-1
SPLINTER User Manual Data Description
In general, one or more UNITS commands may appear in a data block (but see note below) thus permitting the
greatest flexibility in data input. The form of the command is similar to that used in the Preliminary data.
Parameters
UNITS : keyword
unitnm : name of unit to be utilised (see below)
Notes
1. The units defined in the preliminary data must be given for both force and length. The mass unit is a
derived quantity consistent with the units of length and force specified.
2. Locally defined units will be reset at the end of a data block or sub data block. Thus in the example the
MATE data units are reset to the global terms Newtons and metres automatically.
3. In the second units definition in the GEOM data, the force and length units do not form a consistent set
and so a mass unit cannot be derived. This is acceptable to the program provided that the data being
defined does not require a mass or density input. Thus units of Newtons and inches would be
unacceptable in the MATE data where the density is specified. Appendix F provides a list of unit
definitions which permit the calculation of a consistent mass unit.
4. Where mass data has to be supplied, the input can be simplified by choosing the appropriate units of force
and length to provide a consistent unit of mass of either 1 kg (using Newtons and metres) or 1 lb (using
Poundals and feet).
5. In substructure analyses it is important that all of the components and structures have the same global
units definition otherwise assembly of the stiffness matrices and load vectors will not be possible. The
program does not assume that all structures/components created under one project will use the same units,
this must be defined explicitly by the user.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-2
SPLINTER User Manual Data Description
6. If units are employed, the cross checks and results will, by default, be printed in the basic global units
defined in the Preliminary data and any data defined using local unit definitions will be factored
appropriately. The user can optionally override the results units for displacements and/or stresses to be
different to those supplied for the global definitions. For further details see Appendix A.17
7. Where the UNITS command is not used, the user must ensure that all data utilise a consistent system
throughout, e.g.
1. S.I. Units Force in Newtons, length in metres, mass in kilograms, time in
seconds, acceleration in metres/sec2
2. Imperial Units Force in pounds, length in feet, mass in slugs, time in seconds,
acceleration in feet/sec2.
3. Imperial Units Force in poundals, length in feet, mass in pounds, time in seconds,
acceleration in feet/sec2.
For any other set of units, the unit of consistent mass will be a multiple of the basic unit of mass because
it is a derived unit. The consistent unit of mass is obtained by dividing the unit of force by the
acceleration due to gravity, which itself has units of length divided by time squared. A change in the unit
of length, for example from feet to inches or metres to millimetres, requires a corresponding change to the
unit of mass used for calculating the density.
A list of sets of consistent units is given in Appendix F.
8. Valid unit names are as follows
Length unit METRE(S), M
CENTIMETRE(S), CM
MILLIMETRE(S), MM
FOOT, FEET, FT
INCH, INCHES, IN
Force unit NEWTON(S) N
KILONEWTON(S) KN
MEGANEWTON(S) MN
TONNEFORCE(S) TNEF
POUNDAL(S) PDL
POUNDFORCE, LBF
KIP(S) KIP
TONFORCE(S) TONF
KGFORCE(S) KGF
Temperature unit CENTIGRADE, C
FAHRENHEIT, F
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-3
SPLINTER User Manual Data Description
Example
The following example shows a simple structure where the basic global units are N and m but the geometric
properties have been supplied in both mm and inches.
Active Units Defined Derived
SYSTEM PRIME DATA AREA 50000
PROJECT ASAS
FILES ASAS
JOB NEW PILE
OPTIONS GOON END
UNITS N M Newtons Metres Kg
END
COOR
CART
1 0.0 0.0 0.0
2 10.0 0.0 0.0
3 0.0 10.0 0.0
4 20.0 10.0 0.0
END
PILE
SOLP 1
MATP 1
TUBE 1 2 1
TUBE 3 4 2
END
GEOM
UNITS MM Newtons Millimetres Kg x 10-3
1 TUBE 1000.00 75.0
UNITS INCHES Newtons Inches See note 3 above
2 TUBE 28.0 2.5
END
MATE Newtons Metres Kg
1 2.0E11 0.3 0.0 0.0
END
3.2.2. COORDINATE Data
This data is identical to the COOR data in ASAS, as described in Section 5.2.2 of the ASAS User Manual. Note
that global z must be vertically upwards in SPLINTER. The z=0 position may be at, above or below the ground
level (mud-line). If the superstructure has been generated with other than z upward, it can be rotated to the
required direction when assembled to the piles.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-4
SPLINTER User Manual Data Description
3.2.3. PILE Topology Data
To define each pile which makes up the structure. This data is similar to the ASAS ELEM data, and replaces it.
(The ELEM data is not valid in SPLINTER).
Parameters
PILE : compulsory header keyword to define the start of the pile data.
MATP : keyword to define the material to be assigned to all following elements until another MATP line is
used.
material : material property integer. The material properties are defined in Section 3.2.4.
(Integer, 1-9999)
GROU : keyword to define the group to which all following elements are assigned until another GROU
line is used.
group : group number. Only utilised in a pile group analysis. Only non-zero group numbers may be
specified although blank entries are permitted in which case the group defaults to the previous
defined group number. A blank entry must not appear as the first entry in a group analysis. If
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-5
SPLINTER User Manual Data Description
9999, the element results will not be printed. This is useful if dummy elements have to be used in
a pile group analysis (see note 2 and Section 3.2.9). Pile and non pile elements must not be mixed
within one group. (Integer, 1-9999)
SOLP : keyword to define the soil to be assigned to all the following piles until another SOLP line is used
soil : soil property integer. The soil properties are defined in Section 3.2.8. (Integer, 1-999). A soil
number of zero indicates a non-pile element. See note 2 below.
eltype : element type. (Alphanumeric, 4 characters). Only TUBE, BM3D or BEAM is valid.
nodes : list of node numbers to define the element. (Integer, 1-999999)
geom : geometric property integer. (Integer, 1-99999).
eleno : user number of the pile. Every user pile number must be unique. Generated piles are numbered
successively in increments of 1. If omitted the pile numbers are assigned by the program,
numbered according to the input order of the elements. (Integer, 1-99999)
RP : keyword to indicate the generation of data from the previous / symbol.
nrep : the number of times the data is to be generated. (Integer)
inode : node number increment. (Integer)
RRP : keyword to indicate the generation of data from the previous // symbol.
nrrep : the number of times the data is to be generated. (Integer)
iinode : node number increment. (Integer)
END : compulsory key word to denote the end of the pile topology data.
Notes
1. Continuation lines may be used if needed to define nodes, geom and elno.
2. If parts of the superstructure are to be modelled within SPLINTER, this can be achieved by specifying a
soil integer of zero. Note that only TUBEs, BM3Ds and BEAMs are permitted. By combining a group
number 9999 and a soil integer of 0, a dummy member which is not reported in the results can be
generated for group analyses. Care should be exercised in the number of non-pile elements used since the
iterative techniques employed can become inefficient if large parts of the structure are of an elastic
nature. Where possible, component analyses should be carried out first.
Examples
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-6
SPLINTER User Manual Data Description
An example of a simple pile topology data block.
PILE
MATP 1
SOLP 10
TUBE 8 9 1
TUBE 9 10 2
TUBE 8 10 1
TUBE 10 11 1
TUBE 12 8 3
END
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-7
SPLINTER User Manual Data Description
An example of a group pile analysis with dummy non-pile elements.
ELEM
MATP 1
GROU 4
SOLP 2
/
TUBE 101 102 10 1
RP 3,2
GROU 9999
SOLP 0
TUBE 150 250 10
END
3.2.4. Material Properties
This data is identical to the Materials Property data in ASAS, as described in Section 5.2.4 of the ASAS User
Manual.
3.2.5. Geometric Properties
This data is identical to the Geometric Property data in ASAS, as described in Section 5.2.5 of the ASAS User
Manual.
Note that only TUBE elements and BM3D/BEAM elements with tubular section can appear as Piles, but these
may be stepped. Appendix E.1 gives details of stepped beam input data. Beam offsets are not available in
SPLINTER.
3.2.6. Skew Systems
The input of skew systems is identical to their input in ASAS, as described in Section 5.2.7 of the ASAS User
Manual. Either or both of the SKEW and NSKW data blocks are valid in SPLINTER.
3.2.7. Component Topology
The input of component topology data is identical to that required for ASAS, as described in Section 5.2.8 of the
ASAS User Manual.
Note that this data is not valid in a single pile analysis.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-8
SPLINTER User Manual Data Description
3.2.8. SOIL Data
This data defines the inelastic and elastic properties and layering details for each soil column required.
The data is divided into various categories, their use depending on the type of analysis being carried out and the
input requirements of the user. A complete soil set is shown below followed by detailed descriptions of each of
the categories in turn.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-9
SPLINTER User Manual Data Description
Soil data delimiters
SOIL : compulsory header to define the start of the soil data
END : compulsory word to define the end of the soil data
Mudline position definition
This data type is used for defining a global mudline which is different from the global origin. Only one
statement is permissible and can appear anywhere within the soil information.
MUDD muddat
Parameters
MUDD : keyword to identify this as mudline data
muddat : z coordinate of mudline datum relative to the global axes system. If omitted, the mudline is
assumed to pass through the global origin. See also note 2
The following data types define the elastic soil properties and profile required for a pile group analysis. The data
has no effect on single pile analyses. They must precede the appropriate P-Y or T-Z data block for the given soil
number being defined. Only one line of each type may be supplied for any given soil number.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-10
SPLINTER User Manual Data Description
Parameters
isoil : identifying number of the soil property (Integer)
MAPY : keyword for horizontal elastic properties
MATZ : keyword for vertical elastic properties
modulus : elastic soil modulus at global mudline datum (Real) (see MUDD definition)
poisson : poissons ratio for soil (Real)
modify : elastic soil modulus modifier (Real). Optional, see note 6
depth : depth below global mudline datum to constant modulus (Real). Not required if soil modulus
modifier is omitted. Optional, see note 6.
The following data types enable the user to factor P-Y and T-Z data to suit their input requirements. They do not
relate specifically to one soil number and will factor all appropriate soil data following their inclusion. The
factors may be modified within the soil data by inclusion of two or more such lines. See also note 7
Parameters
PFAC : keyword to signify the factor relates to P data
YFAC : keyword to signify the factor relates to Y data
TFAC : keyword to signify the factor relates to T data
ZFAC : keyword to signify the factor relates to Z data
factor : factor by which the data is to be multiplied (Real)
Note the both T-Z and ENDB data will be modified by the TFAC and ZFAC statements.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-11
SPLINTER User Manual Data Description
Horizontal soil properties (P-Y)
These properties may be defined in one of two ways, either explicitly or using parametrically generated curves.
These data sets are repeated until all P-Y soil layers for the given soil integer have been defined.
(i) P-Y curves defined explicitly
Parameters
isoil : identifying number of the soil property. (Integer). Only required on the first P-Y line of a given
soil property.
P-Y : keyword for P-Y data
toplay : depth to top of layer (Real)
botlay : depth to bottom of layer (Real). If omitted curve is defined at one level only. See note 5 Depths
specified are relative to global mudline datum as defined using the MUDD data statement (see
below). A positive depth corresponds to a point below the mudline datum.
P : keyword defining P data ordinates from the P-Y curve.
funitl : force per unit depth. Value taken from P-Y curve. (Real). Continuation lines may be used if
required.
Y : keyword defining Y data ordinates from the P-Y curve
disp : displacement value taken from P-Y curve (Real). The order of the data must correspond with that
used for the P ordinates. Continuation lines may be used if required.
(ii) P-Y curves generated from given soil properties
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-12
SPLINTER User Manual Data Description
Parameters
isoil : identifying number of the soil property. (Integer). Only required on the first P-Y line of a given
soil property.
P-Y : keyword for P-Y data
toplay : depth to top of layer (Real)
botlay : depth to bottom of layer (Real). If omitted curve is defined at one level only. See note 5 Depths
specified are relative to global mudline datum as defined using the MUDD data statement (see
below). A positive depth corresponds to a point below the mudline datum.
REES : keywords specifying the procedure to be used to generate the P-Y curve. See note 8
MATL
MMAT
PY15
SAND : keywords specifying the type of soil under consideration
CLAY
Soils may be of two general types: cohesionless (SAND) or cohesive (CLAY)
The following procedures and soil types are related as follows:
Soil type Solution procedure
SAND REES
CLAY MATL, MMAT or PY15
variables : soil properties required to generate the P-Y curves. (Real).
for soil type SAND these are:
unit weight of soil
angle of internal friction
initial soil modulus
: for soil type CLAY these are:
unit weight of soil
soil shear strength
strain at half the failure strength
STAT : keywords specifying the type of loading under consideration. This may be either static
(STAT)
CYCL or cyclic (CYCL). If omitted, cyclic loading is assumed.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-13
SPLINTER User Manual Data Description
Vertical soil properties (T-Z)
These properties may be defined in one of two ways, either explicitly or using parametrically generated curves.
These data sets are repeated until all T-Z soil layers for the given soil integer have been defined.
For unplugged piles, the internal skin friction will be ignored. Approximate changes to the T-Z data must be
applied to take account of internal skin friction.
(i) T-Z curves defined explicitly.
Parameters
isoil : identifying number of the soil property. (Integer). Only required on the first T-Z line for a given
soil property
T-Z : keyword for T-Z data
toplay : depth to top of layer. (Real)
botlay : depth to bottom of layer. (Real). If omitted curve is defined at one level only. See note 5 Depths
specified are relative to a global mudline datum as defined using the MUDD data statement (see
below). A positive depth corresponds to a point below the mudline datum.
T : keyword defining T data ordinates from the T-Z curve.
funitl : force per unit depth. Value taken from T-Z curve. (Real). Continuation lines may be used if
required.
Z : keyword defining Z data ordinates from the T-Z curve
disp : displacement value taken from T-Z curve. (Real). The order of the data must correspond with that
used for the T ordinates. Continuation lines may be used if required.
(ii) T-Z curves generated from given soil properties
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-14
SPLINTER User Manual Data Description
Parameters
isoil : identifying number of the soil property (Integer) only required on the first P-Y data line of a given
soil property.
T-Z : keyword for T-Z data
toplay : depth to top of layer. (Real)
botlay : depth to bottom of layer. (Real). If omitted curve is defined at one level only. See note 5 Depths
specified are relative to global mudline datum as defined using the MUDD data statement (see
below). A positive depth corresponds to a point below the mudline datum.
V15O : keyword specifying the procedure to be used to generate the T-Z curve. See note 8
V15C The pile may be considered to be either plugged (V15C) or unplugged (V15O)
SAND : keywords specifying the type of soil under consideration
CLAY
Soils may be of two general types: cohesionless (SAND) or cohesive (CLAY)
Either soil type may be used with each solution procedure.
variables : soil properties required to generate the T-Z curves. (Real).
For soil type SAND these are:
unit weight of soil
angle of internal friction
: For soil type CLAY these are:
unit weight of soil
soil shear strength
It is important that the properties are given in the order listed above
SYMM : keywords specifying the shape of the T-Z curves These may be either symmetric (SYMM) or
ASYM : axisymmetric (ASYM). If omitted, a symmetric curve is assumed.
factor : multiplication factor required for the tensile (negative) portion of the T-Z curve. (Real). If
omitted a value of 0.5 is assumed.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-15
SPLINTER User Manual Data Description
End bearing properties (ENDB)
This data is optional and may be omitted if friction piles are being analysed. Only one curve is required since it
is assumed to act upon the pile tip. These properties may be specified in one of two ways, either explicitly or
using generated curves.
(i) ENDB curve defined explicitly
isoil ENDB
T force
Z disp
Parameters
isoil : identifying number of the soil property. (Integer)
ENDB : keyword for end bearing data
T : keyword defining T data ordinates from ENDB curve
force : force value taken from ENDB curve. (Real). Continuation lines may be used if required
Z : keyword defining Z data ordinates from ENDB curve
disp : displacement value taken from ENDB curve (Real). The order of the data must correspond with
that used for the T ordinates. Continuation lines may be used if required.
(ii) ENDB curves generated from given soil properties
Parameters
isoil : identifying number of the soil property (Integer)
ENDB : keyword for ENDB data
V15O : keyword specifying the solution procedure to be used to generate the ENDB curve.
V15C See note 8 The pile may be considered to be either plugged (V15C) or unplugged (V15O)
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-16
SPLINTER User Manual Data Description
SAND : keywords specifying the type of soil under consideration
CLAY
Soils may be of two general types: cohesionless (SAND) or cohesive (CLAY)
Either soil type may be used with each solution procedure.
variables : Soil properties required to generate the ENDB curves. (Real).
for soil type SAND these are:
unit weight of soil
angle of internal friction
: for soil type CLAY these are:
unit weight of soil
soil shear strength
It is important that the properties are given in the order listed above
SYMM : keywords specifying the shape of the ENDB curves. These may be either symmetric
ASYM : (SYMM) or axisymmetric (ASYM). If omitted, a symmetric curve is assumed.
factor : multiplication factor required for the tensile (negative) portion of the ENDB curve. (Real). If
omitted a value of 0.0 is assumed.
Notes
1. There is no limit to the number of points on any curve. For displacements that occur outside of the range
specified for a given curve, linear extrapolation of the last segment of the curve is assumed. If a constant
value is required, two points with similar P or T and different displacement must be input
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-17
SPLINTER User Manual Data Description
2. The MUDD command is used for defining a global mudline which does not coincide with the global
origin. This can be particularly useful if the structure has been coded up with its origin at somewhere
other than the mudline and the user wishes to retain the same coordinate system.
If a particular soil requires a local scour to be modelled, both the P-Y and T-Z data should start at a depth
corresponding to the scour level. Dummy data does not have to be provided over this depth. See
examples 4.1 and 4.8.
3. Both symmetric and non-symmetric curves may be defined for soil data. If symmetric curves are
required, only that part of the curve for positive displacement values need be input. The program will
automatically generate the remaining information.
If any values are defined for a negative displacement then the curve is assumed to be non-symmetric.
Care should be taken in providing non-symmetric P-Y data since the soil stiffnesses derived from the
curves are based upon local axes displacements and these may vary from pile to pile, and from iteration to
iteration. Shifted P-Y curves are not permitted, since this can result in undesired lateral deflections. Use
the SLID command if shifted curves are required.
For T-Z and ENDB data, a positive local displacement for the purposes of soil stiffness formulation is
taken as being defined by the vector going from the pile cap to the pile tip. Thus, zero tensile stiffness for
end bearing forces may be modelled by supplying an ENDB command with zero stiffness for negative
displacements.
4. The soil properties must be defined down to the full depth of the pile, or to a greater depth.
5. If both levels are supplied on a P-Y or T-Z header, the data is taken as a constant between these levels. If
only one level is supplied, the data is defining the properties at one depth in the soil medium. Soil
properties are assumed to vary linearly between single point definitions.
If a sudden change in soil properties is required at a given depth, one of two options are available:
(i) If one or both of the soil definitions represent a constant stratum, the given depth may be supplied
for both layers.
(ii) If both the soil definitions are single point, they must be separated by a finite distance so that the
program can identify which layer is uppermost. Provided the separation is less than the coordinate
tolerance (0.1 x pile diameter) the program will utilise the data as though they represented
coincident layers. The higher of the two levels specified will be adopted as the point of the
discontinuity. See also Section 1.4 on automatic pile subdivision.
6. Three different types of elastic soil modulus for group interaction may be defined.
(i) If the elastic soil modulus modifier is zero (or omitted), the modulus is assumed constant for all
depths.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-18
SPLINTER User Manual Data Description
Example
1 MAPY 120.0 0.4
(ii) If the elastic soil modulus modifier is given a non-zero positive value and the depth to constant modulus
is omitted the elastic modulus increases linearly with depth thus;
Ed = Em + dEL
where Ed = the elastic modulus at depth d below mudline datum
Em = the elastic modulus at mudline datum
d = the depth at which the modulus is being evaluated
EL = the elastic modulus modifier
Example
1 MAPY 120.0 0.4 0.25
(iii) If both the elastic soil modulus modifier and the depth to constant modulus are given positive, non-zero
values, the elastic modulus increases linearly to the depth specified and then remains constant thus:
Ed = Em + dEL d<D
Ed = Em + DEL dD
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-19
SPLINTER User Manual Data Description
where D = the depth specified
Example
1 MAPY 120.0 0.4 0.25 20.0
The depth specified on a MAPY or MATZ command must correspond to a depth supplied for a P-Y or T-Z
curve for the soil number being defined. Failure to do so will result in an error message.
See also Section 1.3 Pile Group Interaction Effects.
7. The factor capability enables users to automatically multiply all their input data by a constant (or
constants). This has several uses:
(i) If the data supplied to the user are not in the correct form e.g pressure curves instead of force per
unit length or the wrong units such as N and mm instead of KN and m then factors may be applied
to convert from one to the other.
(ii) If the data supplied is for a given diameter pile and a different diameter pile is to be analysed, a
factor may be applied to P and T data equal to the ratio of the two diameters.
(iii) If a simplified group analysis is to be carried out utilising Y and Z modifiers, the data can be
factored appropriately.
8. The procedures used for developing P-Y and T-Z curves from user defined soil properties are as indicated
below. Detailed descriptions are not given but a typical curve for each procedure is shown.
Overburden pressures used in the soil curve generation are computed from the soil densities provided
down the soil column. If explicit P-Y and/or T-Z data is provided for any soil layer within a soil column,
then overburden pressures will be computed based upon the soil density local to the point of calculation.
For backwards compatibility the user option OVRL may be specified that enforces the local soil densities
to be used for the overburden pressure.
The α factor used for shaft friction is automatically calculated as specified in Clause 6.4.2 of the API 21st
edition. A limiting value of ϕ is set to 3.0. However no allowance is made for pile length. For
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-20
SPLINTER User Manual Data Description
backwards compatibility the AP15 option may be invoked to use the α calculations from API 15th
edition.
The resulting soil curves depend upon the pile to which it is to be applied since, in the general form,
pressures are generated. A different soil curve set will thus be produced for each pile in an analysis.
Where stepped piles are utilised it is important that two soil definitions are provided at the step position(s)
in order that the correct geometric data is utilised for the curve generation.
(i) For sands, the method suggested by Reese et al (Ref. 1).
P-Y curve for sand
(ii) For clays, the method suggested by Matlock (Ref. 2), a modified Matlock procedure and the basic
recommendations as listed in API 15 (Ref. 3)
P-Y curve for clay: static loading
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-21
SPLINTER User Manual Data Description
P-Y curve for clay : cyclic loading
(iii) For T-Z and ENDB curves, the procedures recommended by Vijayvergiya have been adopted.
For the purposes of the implementation in SPLINTER, the ultimate skin friction and end bearing pressure
that can be developed in cohesionless soils (sand) is limited to the values given in the API RP2A code of
practice. The user should also note that for plugged pile conditions it is assumed that any internal soil
skin friction is sufficient to sustain the plug in position, there is no internal check undertaken to check this
requirement.
T-Z curve for clay and sand
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-22
SPLINTER User Manual Data Description
ENDB curve for clay and sand
Notes
1. For P-Y, T-Z and ENDB curves, the curved section is divided into four divisions by default.
2. For T-Z curves, Zc is taken to be 0.01 x pile diameter
3. For ENDB curves, Zc is taken to be 0.05 x pile diameter
Whenever the soil is defined as banded, P-Y and T-Z curves are evaluated at the mid-point of the band.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-23
SPLINTER User Manual Data Description
Mudslide Definition
This command enables a soil displacement profile to be defined, allowing computation of relative pile-soil
displacements. In addition to traditional mudslide conditions, this command may be used in any situation where
the soil is displaced eg conditions produced by the vicinity of an adjacent structure such as the spud can of a
Jack-Up drilling platform. The command has the effect of internally generating shifted P-Y and/or T-Z curves
which correspond to the soil displacement profile.
where isoil identifying number of soil property as used on P-Y and T-Z data. Only required on the first
SLID command line of a given soil property
SLID compulsory keyword to signify that soil displacement data is being defined
depth depth from mudline to point where soil displacement data is being defined, positive downwards
xdisp soil displacement in the global X axis
ydisp soil displacement in the global Y axis
zdisp soil displacement in the global Z axis
Notes
1. There are no limits to the number of soil movement definitions for a given soil.
2. The depths specified do not have to coincide with other soil data, such as P-Y and T-Z information.
SPLINTER will interpolate values for unspecified depths. For pile depths outside the values specified on
the SLID definition a constant value is adopted equal to the value defined at an adjacent depth.
3. The vertical soil displacement (zdisp) may be omitted if zero. Similarly if both ydisp and zdisp are
zero then they may be omitted.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-24
SPLINTER User Manual Data Description
Soil examples
Example 1
Simple constant linear soil defined between mudline and 100m depth.
T-Z data factored to account for diameter and unit inconsistencies
Y data factored to change units
ENDB data does not require factoring so TFAC and ZFAC set to unity
SOIL
YFAC 0.01
10 P-Y 0.0 100.0
P 0.0 10.0
Y 0.0 0.1
TFAC 2.0
ZFAC 0.1
10 T-Z 0.0 100.0
T 0.0 5.75
Z 0.0 0.1
TFAC 1.0
ZFAC 1.0
10 ENDB
T 0.0 75.0
Z 0.0 1.0
END
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-25
SPLINTER User Manual Data Description
Example 2
Non-linear soil with global mudline set at -10.0
3 layers defined.
1 banded layer between mudline and 10m
Discontinuity defined at 10.0m
Lower layer defined at 30.0m
Non-symmetric ENDB data supplied with zero tensile capability
SOIL
MUDD -10.0
5 P-Y 0.0 10.0
P 0.0 105.0 175.0 71.0 71.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 10.0
P 0.0 125.0 200.0 185.0 185.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 30.0
P 0.0 720.0 1000.0 750.0 750.0
Y 0.0 0.014 0.06 1.0 10.0
5 T-Z 0.0 10.0
T 0.0 50.0 50.0
Z 0.0 0.012 1.0
T-Z 10.0
T 0.0 170.0 170.0
Z 0.0 0.012 1.0
T-Z 30.0
T 0.0 320.0 320.0
Z 0.0 0.012 1.0
5 ENDB
T 0.0 0.0 9000.0 9000.0
Z -1.0 0.0 0.085 1.0
END
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-26
SPLINTER User Manual Data Description
Example 3
Group analysis with two different soil profiles
Soil 12 has constant elastic modulii for group interaction
Soil 34 has different elastic properties in horizontal and vertical directions
Horizontal elastic modulus increases linearly with depth
Vertical elastic modulus increases linearly with depth to 30m, where it becomes constant
No end-bearing data supplied
SOIL
12 MAPY 500.0 0.5
12 P-Y 0.0 10.0
P 0.0 105.0 175.0 71.0 71.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 10.0 30.0
P 0.0 720.0 1000.0 750.0 750.0
Y 0.0 0.014 0.06 1.0 10.0
12 MATZ 500.0 0.5
12 T-Z 0.0 30.0
T 0.0 170.0 170.0
Z 0.0 0.012 1.0
34 MAPY 350.0 0.5 10.0
34 P-Y 0.0 12.0
P 0.0 85.0 150.0 60.0 60.0
Y 0.0 0.016 0.065 1.0 10.0
P-Y 12.0
P 0.0 400.0 720.0 385.0 385.0
Y 0.0 0.02 0.12 1.0 10.0
P-Y 30.0
P 0.0 700.0 985.0 735.0 735.0
Y 0.0 0.02 0.12 1.0 10.0
34 MATZ 300.0 0.5 15.0 30.0
34 T-Z 0.0 30.0
T 0.0 150.0 150.0
Z 0.0 0.010 1.0
END
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-27
SPLINTER User Manual Data Description
Example 4
Generated soil properties defined in 5 layers
The soil is clay
The P-Y data is defined using the PY15 procedure
T-Z and End bearing data is defined using the V15O procedure
SOIL
1 P-Y 0.0 2.0
PY15 CLAY 15. 30. 0.01 STAT
1 P-Y 2.0 5.0
PY15 CLAY 15. 30. 0.01 STAT
1 P-Y 5.0 10.0
PY15 CLAY 15. 30. 0.01 STAT
1 P-Y 10.0 27.5
PY15 CLAY 15. 30. 0.01 STAT
1 P-Y 27.5 100.0
PY15 CLAY 15. 30. 0.01 STAT
1 T-Z 0.0
V15O CLAY 15. 30. SYMM
1 T-Z 2.0 5.0
V15O CLAY 15. 30. SYMM
1 T-Z 5.0 10.0
V15O CLAY 15. 30. SYMM
1 T-Z 10.0 27.5
V15O CLAY 15. 30. SYMM
1 T-Z 27.5 100.0
V15O CLAY 15. 30. SYMM
1 ENDB
V15O CLAY 15. 30. SYMM
END
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-28
SPLINTER User Manual Data Description
Example 5
As example 4 but including a horizontal mudslide in the global x direction which varies from 200 mm at the mud
line to 50 mm at 30 m depth and beyond
SOIL
1 P-Y 0.0 2.0
PY15 CLAY 15. 30. 0.01 STAT
1 P-Y 2.0 5.0
PY15 CLAY 15. 30. 0.01 STAT
1 P-Y 5.0 10.0
PY15 CLAY 15. 30. 0.01 STAT
1 P-Y 10.0 27.5
PY15 CLAY 15. 30. 0.01 STAT
1 P-Y 27.5 100.0
PY15 CLAY 15. 30. 0.01 STAT
1 T-Z 0.0
V15O CLAY 15. 30. SYMM
1 T-Z 2.0 5.0
V15O CLAY 15. 30. SYMM
1 T-Z 5.0 10.0
V15O CLAY 15. 30. SYMM
1 T-Z 10.0 27.5
V15O CLAY 15. 30. SYMM
1 T-Z 27.5 100.0
V15O CLAY 15. 30. SYMM
1 ENDB
V15O CLAY 15. 30. SYMM
1 SLID 0.0 0.200
SLID 2.5 0.190
SLID 7.5 0.180
SLID 10.0 0.170
SLID 20.0 0.120
SLID 30.0 0.050
END
3.2.9. PILE GROUP Definition
Group interaction effects are requested by including the pile group data described below. The data specifies
which piles are assigned to a particular pile group and how they interact with each other either structurally or via
the soil medium.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-29
SPLINTER User Manual Data Description
Parameters
PGRP : compulsory header to define the start of the pile group data.
igroup : identifying number for this pile group (Integer)
NOIN : group defined as consisting of structurally individual piles with no interaction via the soil
INDP : group defined as consisting of structurally individual piles but include interaction via the soil
CONN : group defined as connected rigidly to a pile cap and include interaction via the soil
capnod : node number of pile cap for rigidly connected groups (Integer). See note 2
DEFT : interaction distance to be set to program default. See note 1
MAXP : interaction distance to be user defined. See note 1
maxdis : maximum interaction distance beyond which no interaction will be calculated (Real)
END : compulsory word to define the end of the group data.
Notes
1. In order to reduce computational effort and storage requirements a distance can be specified beyond
which no interaction effects will be calculated. For any given subdivision on a pile, only pile
subdivisions located nearer than the defined maximum distance will be included in the group effect.
The program default is taken as 0.5 x the maximum embedment depth of any two piles being considered.
The maximum interaction distance should not be used to isolate one group of piles from another since
some computational penalty will be incurred. Assign a different group number to each cluster of piles for
which interaction is required even if the data requirements are otherwise identical.
2. For a group pile analysis, all pile elements defined must have an associated group identifier. If
structurally isolated piles are to be modelled then they should be assigned a common group number of
type NOIN. INDP should be used where piles are not physically connected (except by way of the
superstructure) but where group interaction effects are to be included e.g. conductor pile groups.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-30
SPLINTER User Manual Data Description
If a rigid pile cap is required for a group, type CONN should be specified. This type of group requires
the definition of a node representing the pile cap itself to which all the piles will be rigidly connected.
The node defining the pile cap must be connected either to one of the piles or to a structural element or
component. In the situation where a pile cap node is defined in space, a dummy element must be
supplied to locate the pile cap node. A group number of 9999 should be specified for the dummy
element(s) so that they are not printed in the results.
3. Group numbers specified in the PILE data which do not appear in the PGRP data will be designated as
non-interacting.
Example of Pile Group Data
This example specifies 4 separate groups
Group 5 defines a group consisting of structurally individual piles with no interaction
Group 10 is for a group of piles rigidly connected to a pilecap defined by node 100 with default
maximum interaction distance
Group 11 is also a group rigidly connected to a pile cap, given by node 150, but for this group the
maximum interaction distance is user defined as 25.0
Group 8 piles are structurally independent but include interaction effects with default maximum
interaction distance
PGRP
5 NOIN
10 CONN 100 DEFT
11 CONN 150 MAXD 25.0
8 INDP DEFT
END
3.2.10. SECTION Data
To define section type and dimensions for sections to be used with TUBE, BM3D and BEAM elements.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-31
SPLINTER User Manual Data Description
Parameters
SECT : compulsory header keyword to denote the start of the section data.
sectionid : section identifier. (Alphanumeric, up to 12 characters). This identifier must be unique and
independent of the section type.
type : type, or shape, of section being defined. Only valid type for splinter is:
TUB tubular
XSEC : keyword to denote that cross-section dimensions are to be defined on this line. See Note 1.
dimensions : list of section dimensions. See below for the details of which dimensions are required
FLEX : keyword to denote that geometric properties are to be defined on this line. See Note 1
flexprops : list of geometric properties. For all section types this is AX, IZ, IY, J, AY, AZ
where AX cross sectional area
IZ principal moment of inertia about element local Z axis
IY principal moment of inertia about element local Y axis
J torsion constant
AY effective shear area for forces in element local Y direction
AZ effective shear area for forces in element local Z direction
Shear strain is neglected for a given direction if AY and/or AZ is zero.
proptype : name of geometric property to be defined. Valid names are AX, IZ, IY, J, AY, AZ with the
meaning as above.
property : value to be assigned to the named geometric property.
Notes
1. For any given section identifier XSEC and/or FLEX commands may be supplied with the following
interpretations.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-32
SPLINTER User Manual Data Description
If only XSEC is defined, the geometric properties will be automatically calculated by the program for use
in the structural analysis. The section dimensions will be utilised in the stress calculations and areas
where these data are required explicitly, e.g. automatic pile sub-division.
FLEX Command alone is not allowed in Splinter. In addition, the FLEX command is not valid for a
TUBE element.
If both XSEC and FLEX commands are utilised, any geometric properties explicitly defined will
overwrite those calculated from the section dimensions. The use of XSEC and FLEX together is not
permitted for TUBE elements. This feature permits modification to the stiffness of the section to model
ring or web stiffeners, built up sections, etc. The section dimensions will be utilised in the stress
calculations and areas where these data are required explicitly, e.g. automatic pile sub-division.
2. The FLEX and XSEC sub-commands and associated data are interchangeable, i.e. FLEX appears on the
sectionid line with the XSEC command on a continuation line.
e.g T30XP15 TUB XSEC 0.3 0.015
: FLEX 0.015 0.00015 0.00015
0.0003
is the same as
T30XP15 TUB FLEX 0.015 0.00015 0.00015 0.0003
: XSEC 0.3 0.015
Tube - Type TUB - Section Dimensions
Two dimensions must be defined
Y
Values are D T T
where D = the outer diameter
T = the wall thickness Z Z
D
3.3. BOUNDARY Conditions Data
Y
3.3.1. UNITS Command for Boundary Conditions
The units command is not valid in the restraint data and will be ignored. Note that this requires that constants
and factors utilised in constraint equations must be consistent with the global units defined in the preliminary
data, if appropriate (see Appendix A.17).
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-33
SPLINTER User Manual Data Description
3.3.2. SUPPRESSIONS Data
This data is identical to the Suppressions data in ASAS, as described in Section 5.3.3 of the ASAS User Manual.
3.3.3. DISPLACED FREEDOMS Data
This data is identical to the Displaced Freedoms data in ASAS, as described in Section 5.3.4 of the ASAS User
Manual.
Note: Prescribed displacements can only be applied to pile cap nodes. Pile tip nodes cannot be assigned
prescribed displacement values.
3.3.4. CONSTRAINT EQUATIONS Data
This data is identical to the Constraint Equation data in ASAS, as described in Section 5.3.5 of the ASAS User
Manual.
Note: Constraint equations can only be applied to pile cap nodes. Pile tip nodes cannot be included as part of a
constraint equation.
3.3.5. LINK FREEDOM Data
This data is identical to the Link Freedom data in ASAS, as described in Section 5.3.6 of the ASAS User
Manual.
3.3.6. RIGID CONSTRAINTS Data
This data is identical to the Rigid Constraint data in ASAS, as described in Section 5.3.8 of the ASAS User
Manual.
Note: Rigid constraints can only be applied to pile cap nodes. Pile tip nodes cannot be included as part of the
rigid constraint data.
3.3.7. FREEDOM RELEASE Data
This data is identical to the Freedom Release Data in ASAS, as described in Section 5.3.2 of the ASAS User
Manual.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-34
SPLINTER User Manual Data Description
Note: It is only possible for pile cap nodes on piles to be released, and only global degrees of freedom releases
are available. Pile tip nodes cannot be released, nor may local axis releases be applied.
3.4. LOAD Data
This data is identical in format to the Load data in ASAS, as described in section 5.4 of the ASAS User Manual.
Only 5 load types are valid in SPLINTER as detailed on the following pages.
3.4.1. UNITS Command for LOAD Data
If global units have been defined using the UNITS command in the Preliminary data (see Appendix A.17), it is
possible to override the input units locally to load type by the inclusion of a UNITS command. The local units
are only operational for the current load type concerned. They must be defined after the load type header and
will return to the default global units when the next load type, or load case, is encountered.
In general, one or more UNITS commands may appear in a data block thus permitting the greatest flexibility in
data input. The form of the command is similar to that used in the Preliminary data.
Parameters
UNITS : keyword
unitnm : name of unit to be utilised (see below)
Notes
1. Force, length and angular unit may be specified. Only those terms which are required to be modified
need to be specified, undefined terms will default to those supplied on the global units definition unless
previously overwritten in the current data block.
2. The default angular unit for all load types is radians.
3. Valid unit names are defined in Section 5.1 of the ASAS User Manual.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-35
SPLINTER User Manual Data Description
Example Operational Units Notes
SYSTEM DATA AREA 50000
PROJECT ASAS
FILES ASAS
JOB LINE
UNITS NEWTON METRE Newtons, metres, Global definition
END centigrade
.
.
.
LOAD 2
CASE 1 ’NODAL AND DISTRIBUTED LOADS’
NODAL L0
UNITS KN Kilonewtons, metres, Note default
X 10.0 5 6 7 radians angular unit
Y 15.0 1 2
UNITS MM Kilonewtons, Moments input in
RY 250.0 8 millimetres, radians KNmm
RZ 300.0 5 6 7
END
DISTRIBU Newtons, metres, Units revert to
Y BLI 1000.0 1200.0 5 6 radians global units
Z BLI 900.0 1050.0 5 6
UNITS KN Kilonewtons, metres, Change force
Y BL1 1.5 1.6 5 6 unit to KN
END
*
CASE 2 ’DISTRIBUTED LOAD ONLY’
DISTRIBU Newtons, metres, New load case
Z BL5 1200.0 5 6 radians reverts units to
END global
STOP
3.4.2. NODAL LOADS Data
This data is identical in the Nodal Loads data in ASAS, as described in Section 5.4.3 of the ASAS User Manual.
Note that nodal loads may not be applied to pile tip nodes.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-36
SPLINTER User Manual Data Description
3.4.3. PRESCRIBED DISPLACEMENTS Data
This data is identical to the Prescribed Displacements data in ASAS, as described in Section 5.4.4 of the ASAS
User Manual.
Note that prescribed displacements may not be specified at pile tip nodes. See Section 3.4.4.
Extreme caution must be used when applying prescribed displacements to pile groups. The nature of the
interaction in the group can produce erroneous effects if lateral displacements are applied. Rotational prescribed
displacements are normally satisfactory.
3.4.4. DISTRIBUTED LOADS Data
This data is identical to the Distributed Loads data in ASAS, as described in section 5.4.6 of the ASAS User
Manual.
Note that only BL5, BL6 and BL7 loads are allowed. (These are intermediate point loads, linearly varying
distributed load and quadratically varying distributed load respectively). It is possible to use the BL5 load type
to specify pile tip loads by specifying the distance from the end of the member to the point of application as
either zero or the pile length as appropriate.
3.4.5. BODY FORCES
This data is identical to the Body Forces data in ASAS, as described in Section 5.4.9 of the ASAS User Manual.
Note that a non-zero density must be assigned to the pile material properties where body forces are required.
The BODY option should be used on the OPTIONS command.
3.4.6. COMPONENT LOADS Data
This data is identical to the Component Loads data in ASAS, as described in Section 5.4.12 of the ASAS User
Manual.
Note, this data is only relevant where substructures have been used to create the structure for a soil-pile-structure
analysis.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-37
SPLINTER User Manual Data Description
3.5. UNITY Check Data
To define data required for unity check calculations according to the American Petroleum Institute
‘Recommended Practice for Planning, Designing and Constructing Fixed Offshore Platforms’. A UNITS
command must be present in the preliminary data.
Parameters
UNCK : compulsory header keyword to denote the start of the unity check data
UNITS : keyword to define data units
unitm : name of data unit to be utilised
WSD : keyword to select working stress design methods
LRFD : keyword to select limiting resistance and factored load design methods
ED17 : refers to the edition numbers available of the API RP2A WSD Code of Practice
ED20
ED21
ED1 : refers to the edition available of the API RP2A LRFD Code of Practice
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-38
SPLINTER User Manual Data Description
YIEL : keyword to define yield data
value : yield value
STEP : keyword to define pile step number
stepno : pile step number to which yield value applies
ELEM : keyword to define user element number
PROP : keyword to define geometric property number
number : list of user element numbers or geometric property numbers to which yield value applies
EXTR : keyword to define extreme loadcases (WSD methods only)
loadno : user loadcase number for extreme loadcase
END : keyword to denote end of unity check data
Priority for YIEL values:
ELEM information overrides PROP information
PROP information referenced by STEP overrides ELEM or PROP definition as a whole
ELEM information referenced by STEP overrides PROP information referenced by STEP
Note
The API LRFD standard utilises limit state checks with resistance coefficients to achieve the desired level of
safety. In keeping with this principle, applied loads must be multiplied by appropriate factors, as defined in the
code of practice (Section C, Loads), to develop the design load case combinations necessary for processing.
Since SPLINTER is a non-linear program the factored loads must be applied within its own data. For the WSD
method the desired safety limits are achieved using safety factors. In order to account for extreme environmental
conditions a one-third increase in the allowable stress is permitted, and this can be requested using the EXTR
command for the appropriate load cases.
The following utilisation checks are undertaken when requested:
API WSD (Editions 17, 20 and 21)
UC =
fa
+
(f by
2
+ f bz 2 )
0.6 Fxc Fb
where fa = axial stress
Fxc = inelastic local buckling stress
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-39
SPLINTER User Manual Data Description
fby, fbz = bending stresses (including second order effects if PDEL option selected)
Fb = allowable bending stress
A one-third increase in the allowable stresses is included if an extreme loadcase is being processed.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-40
SPLINTER User Manual Data Description
API LRFD (Edition 1)
π fc
UC = 1 - cos
(f by
2
+ f bz 2 )
+
2 φc Fxc
φb Fbn
where fc = axial compressive stress
Fxc = inelastic local buckling strength
fby, fbz = bending stresses (including second order effects if PDEL option selected)
Fbn = nominal bending strength
φc = resistance factor for axial compressive strength
φb = resistance factor for bending
π f t
Note: for tensile piles the axial term of the above check is changed to cos
2 φt F y
where ft = axial tensile stress
Fy = yield stress
φt = resistance factor for axial tensile strength
3.6. STIFFNESS MATRIX Data
This data is identical to the Stiffness Matrix Data in ASAS, as described in Section 5.7 of the ASAS User
Manual.
3.7. STOP Command
A STOP command is required to indicate the end of the data. It is described in Section 5.9 of the ASAS User
Manual.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-41
SPLINTER User Manual Data Description
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 3-42
SPLINTER User Manual Examples
4. Examples
The following examples illustrate many of the facilities which are available within the SPLINTER program.
Results files have been condensed to show typical output for a given analysis and, therefore, do not represent
complete listings which would normally be produced. Appendix C describes the options which can be utilised
for automatic selection of output requirements.
For the pile structure interaction examples, the ASAS result files for component creation and recovery have not
been included.
The examples supplied are as follows:
1. Single pile analysis
2. Pile structure interaction
3. Group pile analysis
4. Group pile structure interaction
4.1. Example of a Single Pile Analysis
This analysis consists of a single tubular pile of constant diameter and thickness, and length of 123.3ft. The pile
is embedded in the following soil:
Depth - ft Description
0-37 Varying from fine-medium sand to medium-dense sand
37-54.5 Very sandy, stiff clay
54.5-215 Varying from grey fine-medium sand to medium-dense sand
The pile is subjected to both lateral and axial loading at the pile cap.
The data is to be in units of kips and feet.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-1
SPLINTER User Manual Examples
Curve Points
Depth 1 2 3 4 5 6 7 8 9 10
0.0 P 0.0 0.0
0.0 1.0
Y
5.0 P 0.0 0.2 0.3 0.4 0.4 0.5 0.6 0.6 0.4 0.4
0.0 0.225 0.45 0.675 0.9 1.5 2.1 2.7 2.7 10.0
Y
5.0 P 0.0 0.8 0.9 1.0 1.1 1.3 1.3
0.0 0.2 0.4 0.6 0.975 1.35 10.0
Y
7.5 P 0.0 62.7 125.4 188.1 235.6 264.0 285.0 327.4 369.7 369.7
0.0 0.035 0.07 0.105 0.27 0.435 0.6 0.975 1.35 10.0
Y
7.5 P 0.0 63.0 125.9 188.9 236.6 265.1 286.2 328.8 371.5 371.5
0.0 0.035 0.105 0.105 0.27 0.435 0.6 0.975 1.35 10.0
Y
37.0 P 0.0 2036.1 4072.2 6108.3 7512.5 8677.1 9692.8 12600.0 15508.4 15508.4
0.0 0.076 0.153 0.229 0.353 0.476 0.6 0.975 1.35 10.0
Y
37.0- P 0.0 990.0 1575.0 1980.0 2250.0 2790.0 3060.0 3240.0 3240.0
54.5 0.0 0.225 0.45 0.675 0.9 1.5 2.1 2.7 10.0
Y
54.5 P 0.0 5114.2 10288.5 15342.7 16599.7 17761.1 18845.6 24499.3 30153.0 30153.0
0.0 0.130 0.261 0.391 0.461 0.530 0.6 0.975 1.35 10.0
Y
215. P 0.0 16727.5 33454.9 50182.4 51801.7 53367.9 54885.9 71351.6 87817.4 87817.4
0 0.0 0.166 0.332 0.498 0.532 0.566 0.6 0.975 1.35 10.0
Y
Soil force (P) lbs/in
Deflection (Y) inches
Table 4.1 P-Y Soil Data as supplied for 36′′ pile
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-2
SPLINTER User Manual Examples
Curve Points
Depth 1 2 3 4 5
0.0-5.0 T 0.0 0.0
Z 0.0 10.0
37.0 T -0.59 -0.59 0.0 0.82 0.82
Z -10.0 10.144 0.0 0.144 10.0
37-54.5 T 0.0 1.0 1.0
Z 0.0 0.144 10.0
54.5 T -0.82 -0.82 0.0 1.15 1.15
Z -10.0 -0.144 0.0 0.144 10.0
92.0-127.0 T -1.43 -1.43 0.0 2.0 2.0
Z -10.0 -0.144 0.0 0.144 10.0
127.0-215.0 T -2.0 -2.0 0.0 2.0 2.0
Z -10.0 -0.144 0.0 0.144 10.0
Soil pressure (T) Kips/square foot
Displacement (Z) Inches
Table 4.2 T-Z Soil Data as supplied for 36′′ pile
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-3
SPLINTER User Manual Examples
Curve Points
1 2 3 4 5 6 7 8
T 0.0 0.0 827.20 1042.00 1192.60 1312.50 1413.70 1413.70
Z -10.0 0.0 0.36 0.72 1.08 1.44 1.8 10.0
End force T Kips
Displacement Z Inches
Table 4.3 End Bearing Soil Data as supplied for 36′′ pile
Notes on data for example 1.
1. The first 5 feet of soil is subject to local scour and is modelled by starting the P-Y and T-Z data at this
depth.
2. Both single point and layered curves are included.
3. The two methods for modelling soil discontinuities are shown on the P-Y data at depths 7.5ft. and 37ft.
i.e. if both curves at the discontinuity are single point definitions then they must be separated by a small
distance; if one of the curves defines a soil layer then the depths for the two curves may be the same.
4. All displacement terms in the P-Y and T-Z data are in units of inches. Since the analysis is to be carried
out in units of feet YFAC and ZFAC commands are included to adjust the terms accordingly.
5. The P data is supplied in terms of lbs/in. A PFAC command precedes the P-Y data to convert to Kips/ft.
Similarly, a TFAC command precedes the T-Z data to convert the T information from a pressure of
kips/square foot to a force of kips/ft length of pile
A second TFAC command precedes the ENDB data since the supplied information is already in the
correct units.
6. Interaction effects between axial and lateral loads have been included with the PDEL option.
7. The pile self weight is modelled using the BODY FORCE load type.
8. Three loadcases are applied with progressively larger axial loading in each case. In order to optimise
convergence, the INCR option has been included.
9. Convergence criteria has been redefined as 0.1% (0.001)
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-4
SPLINTER User Manual Examples
SYSTEM DATA AREA 30000
JOB NEW PILE
PROJECT EXM1
TITLE SPLINTER MANUAL EXAMPLE 1
TEXT *************************************************
TEXT SINGLE PILE ANALYSIS
TEXT CONSTANT DIAMETER 3.00 FEET
TEXT CONSTANT THICKNESS .17 FEET
TEXT LENGTH OF PILE 123.30 FEET
TEXT 3 LOADCASES
TEXT LC 1 AXIAL LOAD 200 KIPS
TEXT LAT LOAD 25 KIPS
TEXT LC 2 AXIAL LOAD 400 KIPS
TEXT LAT LOAD 25 KIPS
TEXT LC 3 AXIAL LOAD 600 KIPS
TEXT LAT LOAD 25 KIPS
TEXT
TEXT SECOND ORDER MOMENTS INCLUDED
TEXT
TEXT CONVERGENCE SET TO 0.1 PERCENT
TEXT
TEXT UNITS KIPS , FEET
TEXT
TEXT *************************************************
OPTIONS GOON NOBL PRNO NODL SOIL PDEL INCR
CONVERGE 0.001
UNITS KIPS FEET
END
COOR
CART
1 0.0 0.0 0.0
2 0.0 0.0 -123.3
END
PILE
*
* MATERIAL AND SOIL PROPERTY NOW GIVEN ON SEPARATE CARDS
*
MATP 1
SOLP 1
TUBE 1 2 1 100
END
SOIL
*
* FACTOR CARDS TO CONVERT TO FEET AND KIPS
*
YFAC 0.08333
ZFAC 0.08333
PFAC 0.012
1 P-Y 5.0
P 0.0 0.8 0.9 1.0 1.1 1.3 1.3
Y 0.0 0.2 0.4 0.6 0.975 1.35 10.0
P-Y 7.5
P 0.0 62.7 125.4 188.1 235.6 264.0
: 285.0 327.4 369.7 369.7
Y 0.0 0.035 0.07 0.10 0.27 0.435
: 0.6 0.975 1.35 10.0
P-Y 7.501
P 0.0 63.0 125.9 188.9 236.6 265.1
: 286.2 328.8 371.5 371.5
Y 0.0 0.035 0.07 0.105 0.27 0.435
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-5
SPLINTER User Manual Examples
: 0.6 0.975 1.35 10.0
P-Y 37.0
P 0.0 2036.1 4072.2 6108.3 7512.5 8677.1
: 9692.8 12600.0 15508.4 15508.4
Y 0.0 0.076 0.153 0.229 0.353 0.476
: 0.6 0.975 1.35 10.0
P-Y 37.0 54.5
P 0.0 990.0 1575.0 1980.0 2250.0 2790.0
: 3060.0 3240.0 3240.0
Y 0.0 0.225 0.45 0.675 0.9 1.5
: 2.1 2.7 10.0
P-Y 54.5
P 0.0 5114.2 10228.5 15342.7 16599.7 17761.1
: 18845.6 24499.3 30153.0 30153.0
Y 0.0 0.130 0.261 0.391 0.461 0.530
: 0.6 0.975 1.35 10.0
P-Y 215.0
P 0.0 16727.5 33454.9 50182.4 51801.7 53367.9
: 54885.9 71351.6 87817.4 87817.4
Y 0.0 0.166 0.332 0.498 0.532 0.566
: 0.6 0.975 1.35 10.0
*
* SECOND FACTOR COMMAND TO ACCOUNT FOR DIAMETER OF PILE
*
TFAC 9.4248
1 T-Z 5.0
T 0.0 0.0 1.0E-6
Z 0.0 10.0 12.0
T-Z 37.0
T -0.59 -0.59 0.0 0.82 0.82
Z -10.0 -0.144 0.0 0.144 10.0
T-Z 37.0 54.5
T 0.0 1.0 1.0
Z 0.0 0.144 10.0
T-Z 54.5
T -0.82 -0.82 0.0 1.15 1.15
Z -10.0 -0.144 0.0 0.144 10.0
T-Z 92.0 127.0
T -1.43 -1.43 0.0 2.0 2.0
Z -10.0 -0.144 0.0 0.144 10.0
T-Z 127.0 215.0
T -2.0 -2.0 0.0 2.0 2.0
Z -10.0 -0.144 0.0 0.144 10.0
*
* RESET FACTOR TO ONE SINCE ENDB ALREADY IN CORRECT UNITS
*
TFAC 1.0
1 ENDB
T 0.0 0.0 827.2 1042.0 1192.6 1312.5
: 1413.7 1413.7
Z -10.0 0.0 0.36 0.72 1.08 1.44
: 1.8 10.0
END
MATE
1 4.320D06 0.3 0.0 1.52E-2
END
GEOM
1 TUBE 3.0 0.17
END
LOAD 3
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-6
SPLINTER User Manual Examples
CASE 1 AXIAL 200. LATERAL 25. SELF WEIGHT
NODAL LO
X 25.0 1
Z -200.0 1
END
BODY FOR
0.0 0.0 -32.2
END
CASE 2 AXIAL 400. LATERAL 25. SELF.WEIGHT
NODAL LO
X 25.0 1
Z -400.0 1
END
BODY FOR
0.0 0.0 -32.2
END
CASE 3 AXIAL 600. LATERAL 25. SELF WEIGHT
NODAL LO
X 25.0 1
Z -600.0 1
END
BODY FOR
0.0 0.0 -32.2
END
STOP
Figure 4.1 Example 1, Single Pile SPLINTER Data
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-7
SPLINTER User Manual Examples
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-8
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
SPLINTER User Manual
1SPLINTER 13.01.00.0 (QA) 09:23 02-05-2001 PAGE 1
*************************************************
SINGLE PILE ANALYSIS
CONSTANT DIAMETER 3.00 FEET
CONSTANT THICKNESS .17 FEET
LENGTH OF PILE 123.30 FEET
3 LOADCASES
LC 1 AXIAL LOAD 200 KIPS
LAT LOAD 25 KIPS
LC 2 AXIAL LOAD 400 KIPS
LAT LOAD 25 KIPS
LC 3 AXIAL LOAD 600 KIPS
LAT LOAD 25 KIPS
SECOND ORDER MOMENTS INCLUDED
CONVERGENCE SET TO 0.1 PERCENT
UNITS KIPS , FEET
*************************************************
A S A S EXECUTION CONTROL OPTIONS
------------------------------------
USER OPTIONS GOON NOBL PRNO NODL SOIL PDEL INCR
CONVERGE 0.001
RUN PARAMETERS
--------------
PROJECT NAME EXM1
PROJECT STATUS NEW
JOB TYPE PILE
STRUCTURE NAME EXM1
FILE NAME EXM1
RESTART STAGE 1 STARTED
SPLINTER PROGRAM PARAMETERS
---------------------------
MAXIMUM NUMBER OF ITERATIONS 10 (DEFAULT)
RELATIVE CONVERGENCE VALUE USED 1.000D-03
BASIC PILE SUBDIVISION CRITERIA 1.000 PILE DIAMETERS (DEFAULT)
SUBDIVISION MODIFIER 0.100 (DEFAULT)
PILES ARE SUBDIVIDED ON THE FOLLOWING BASIS
Examples
(1) AT POINTS OF APPLICATION OF EXTERNAL LOADS
Page 4-9
(2) AT SOIL LAYER DIVISIONS
(3) AT CHANGES IN PILE SECTION PROPERTIES
IN ADDITION,NO SUBDIVISION WILL BE LONGER THAN
THE BASIC SUBDIVISION PLUS A PERCENTAGE OF THE
DEPTH GIVEN BY THE SUBDIVISION MODIFIER
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
SPLINTER User Manual
S O I L P R O P E R T Y D A T A
---------------------------------------
---------------------------------------
SOIL ELEMENT PILE
NUMBER NUMBER DIAMETER CURVE SORTED VALUES
------ ------- -------- ----- --------------
1 100 3.0000D+00 P-Y 5.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
P -1.5600D-02 -1.5600D-02 -1.3200D-02 -1.2000D-02 -1.0800D-02 -9.6000D-03
P 0.0000D+00 9.6000D-03 1.0800D-02 1.2000D-02 1.3200D-02 1.5600D-02
P 1.5600D-02
Y -8.3330D-01 -1.1250D-01 -8.1247D-02 -4.9998D-02 -3.3332D-02 -1.6666D-02
Y 0.0000D+00 1.6666D-02 3.3332D-02 4.9998D-02 8.1247D-02 1.1250D-01
Y 8.3330D-01
1 100 3.0000D+00 P-Y 7.5000D+00 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
P -4.4364D+00 -4.4364D+00 -3.9288D+00 -3.4200D+00 -3.1680D+00 -2.8272D+00
P -2.2572D+00 -1.5048D+00 -7.5240D-01 0.0000D+00 7.5240D-01 1.5048D+00
P 2.2572D+00 2.8272D+00 3.1680D+00 3.4200D+00 3.9288D+00 4.4364D+00
P 4.4364D+00
Y -8.3330D-01 -1.1250D-01 -8.1247D-02 -4.9998D-02 -3.6249D-02 -2.2499D-02
Y -8.3330D-03 -5.8331D-03 -2.9166D-03 0.0000D+00 2.9166D-03 5.8331D-03
Y 8.3330D-03 2.2499D-02 3.6249D-02 4.9998D-02 8.1247D-02 1.1250D-01
Y 8.3330D-01
1 100 3.0000D+00 P-Y 7.5000D+00 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
P -4.4580D+00 -4.4580D+00 -3.9456D+00 -3.4344D+00 -3.1812D+00 -2.8392D+00
P -2.2668D+00 -1.5108D+00 -7.5600D-01 0.0000D+00 7.5600D-01 1.5108D+00
P 2.2668D+00 2.8392D+00 3.1812D+00 3.4344D+00 3.9456D+00 4.4580D+00
P 4.4580D+00
Y -8.3330D-01 -1.1250D-01 -8.1247D-02 -4.9998D-02 -3.6249D-02 -2.2499D-02
Y -8.7497D-03 -5.8331D-03 -2.9166D-03 0.0000D+00 2.9166D-03 5.8331D-03
Y 8.7497D-03 2.2499D-02 3.6249D-02 4.9998D-02 8.1247D-02 1.1250D-01
Y 8.3330D-01
1 100 3.0000D+00 P-Y 3.7000D+01 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
P -1.8610D+02 -1.8610D+02 -1.5120D+02 -1.1631D+02 -1.0413D+02 -9.0150D+01
P -7.3300D+01 -4.8866D+01 -2.4433D+01 0.0000D+00 2.4433D+01 4.8866D+01
P 7.3300D+01 9.0150D+01 1.0413D+02 1.1631D+02 1.5120D+02 1.8610D+02
P 1.8610D+02
Y -8.3330D-01 -1.1250D-01 -8.1247D-02 -4.9998D-02 -3.9665D-02 -2.9415D-02
Y -1.9083D-02 -1.2749D-02 -6.3331D-03 0.0000D+00 6.3331D-03 1.2749D-02
Y 1.9083D-02 2.9415D-02 3.9665D-02 4.9998D-02 8.1247D-02 1.1250D-01
Y 8.3330D-01
1 100 3.0000D+00 P-Y 3.7000D+01 5.4500D+01 0.0000D+00 0.0000D+00 0.0000D+00
P -3.8880D+01 -3.8880D+01 -3.6720D+01 -3.3480D+01 -2.7000D+01 -2.3760D+01
P -1.8900D+01 -1.1880D+01 0.0000D+00 1.1880D+01 1.8900D+01 2.3760D+01
P 2.7000D+01 3.3480D+01 3.6720D+01 3.8880D+01 3.8880D+01
Y -8.3330D-01 -2.2499D-01 -1.7499D-01 -1.2500D-01 -7.4997D-02 -5.6248D-02
Y -3.7499D-02 -1.8749D-02 0.0000D+00 1.8749D-02 3.7499D-02 5.6248D-02
Y 7.4997D-02 1.2500D-01 1.7499D-01 2.2499D-01 8.3330D-01
Examples
1 100 3.0000D+00 P-Y 5.4500D+01 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
Page 4-10
P -3.6184D+02 -3.6184D+02 -2.9399D+02 -2.2615D+02 -2.1313D+02 -1.9920D+02
P -1.8411D+02 -1.2274D+02 -6.1370D+01 0.0000D+00 6.1370D+01 1.2274D+02
P 1.8411D+02 1.9920D+02 2.1313D+02 2.2615D+02 2.9399D+02 3.6184D+02
P 3.6184D+02
Y -8.3330D-01 -1.1250D-01 -8.1247D-02 -4.9998D-02 -4.4165D-02 -3.8415D-02
Y -3.2582D-02 -2.1749D-02 -1.0833D-02 0.0000D+00 1.0833D-02 2.1749D-02
Y 3.2582D-02 3.8415D-02 4.4165D-02 4.9998D-02 8.1247D-02 1.1250D-01
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
SPLINTER User Manual
Y 8.3330D-01
1 100 3.0000D+00 P-Y 2.1500D+02 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
P -1.0538D+03 -1.0538D+03 -8.5622D+02 -6.5863D+02 -6.4041D+02 -6.2162D+02
P -6.0219D+02 -4.0146D+02 -2.0073D+02 0.0000D+00 2.0073D+02 4.0146D+02
P 6.0219D+02 6.2162D+02 6.4041D+02 6.5863D+02 8.5622D+02 1.0538D+03
P 1.0538D+03
Y -8.3330D-01 -1.1250D-01 -8.1247D-02 -4.9998D-02 -4.7165D-02 -4.4332D-02
Y -4.1498D-02 -2.7666D-02 -1.3833D-02 0.0000D+00 1.3833D-02 2.7666D-02
Y 4.1498D-02 4.4332D-02 4.7165D-02 4.9998D-02 8.1247D-02 1.1250D-01
Y 8.3330D-01
1 100 3.0000D+00 T-Z 5.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
T -9.4248D-06 0.0000D+00 0.0000D+00 0.0000D+00 9.4248D-06
Z -9.9996D-01 -8.3330D-01 0.0000D+00 8.3330D-01 9.9996D-01
1 100 3.0000D+00 T-Z 3.7000D+01 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
T -5.5606D+00 -5.5606D+00 0.0000D+00 7.7283D+00 7.7283D+00
Z -8.3330D-01 -1.2000D-02 0.0000D+00 1.2000D-02 8.3330D-01
1 100 3.0000D+00 T-Z 3.7000D+01 5.4500D+01 0.0000D+00 0.0000D+00 0.0000D+00
T -9.4248D+00 -9.4248D+00 0.0000D+00 9.4248D+00 9.4248D+00
Z -8.3330D-01 -1.2000D-02 0.0000D+00 1.2000D-02 8.3330D-01
1 100 3.0000D+00 T-Z 5.4500D+01 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
T -7.7283D+00 -7.7283D+00 0.0000D+00 1.0839D+01 1.0839D+01
Z -8.3330D-01 -1.2000D-02 0.0000D+00 1.2000D-02 8.3330D-01
1 100 3.0000D+00 T-Z 9.2000D+01 1.2700D+02 0.0000D+00 0.0000D+00 0.0000D+00
T -1.3477D+01 -1.3477D+01 0.0000D+00 1.8850D+01 1.8850D+01
Z -8.3330D-01 -1.2000D-02 0.0000D+00 1.2000D-02 8.3330D-01
1 100 3.0000D+00 T-Z 1.2700D+02 2.1500D+02 0.0000D+00 0.0000D+00 0.0000D+00
T -1.8850D+01 -1.8850D+01 0.0000D+00 1.8850D+01 1.8850D+01
Z -8.3330D-01 -1.2000D-02 0.0000D+00 1.2000D-02 8.3330D-01
1 100 3.0000D+00 ENDB 0.0000D+00
T 0.0000D+00 0.0000D+00 8.2720D+02 1.0420D+03 1.1926D+03 1.3125D+03
T 1.4137D+03 1.4137D+03
Z -8.3330D-01 0.0000D+00 2.9999D-02 5.9998D-02 8.9996D-02 1.2000D-01
Z 1.4999D-01 8.3330D-01
RESTART STAGE 1 COMPLETED
FREESTORE USED 30000
CPU = 0.297 FOR STAGE 1
PILE CAP DISPLACEMENTS AND REACTIONS ITERATION REPORT
LOAD CASE NO. 1 ITERATION 1
------------------ -------------
RESULTANT PERCENTAGE RESULTANT PERCENTAGE
NODE FD DISPLACEMENT REACTION DISPLACEMENT CHANGE REACTION CHANGE
---- -- ------------ ----------- ------------ ---------- ----------- ----------
1 X 1.3116D-02 0.0000D+00
Y 0.0000D+00 0.0000D+00 1.3769D-02 0.0000D+00
Examples
Z -4.1911D-03 0.0000D+00
Page 4-11
RX 0.0000D+00 0.0000D+00
RY 8.2693D-04 0.0000D+00 8.2693D-04 0.0000D+00
RZ 0.0000D+00 0.0000D+00
ITERATION 1 COMPLETED
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
SPLINTER User Manual
PILE CAP DISPLACEMENTS AND REACTIONS ITERATION REPORT
LOAD CASE NO. 1 ITERATION 2
------------------ -------------
RESULTANT PERCENTAGE RESULTANT PERCENTAGE
NODE FD DISPLACEMENT REACTION DISPLACEMENT CHANGE REACTION CHANGE
---- -- ------------ ----------- ------------ ---------- ----------- ----------
1 X 1.3154D-02 0.0000D+00
Y 0.0000D+00 0.0000D+00 1.3806D-02 2.6330D-01 0.0000D+00 0.0000D+00
Z -4.1911D-03 0.0000D+00
RX 0.0000D+00 0.0000D+00
RY 8.3012D-04 0.0000D+00 8.3012D-04 3.8582D-01 0.0000D+00 0.0000D+00
RZ 0.0000D+00 0.0000D+00
ITERATION 2 COMPLETED
LOAD CASE NO. 1 ITERATION 3
------------------ -------------
RESULTANT PERCENTAGE RESULTANT PERCENTAGE
NODE FD DISPLACEMENT REACTION DISPLACEMENT CHANGE REACTION CHANGE
---- -- ------------ ----------- ------------ ---------- ----------- ----------
1 X 1.3154D-02 0.0000D+00
Y 0.0000D+00 0.0000D+00 1.3806D-02 1.6108D-03 0.0000D+00 0.0000D+00
Z -4.1911D-03 0.0000D+00
RX 0.0000D+00 0.0000D+00
RY 8.3014D-04 0.0000D+00 8.3014D-04 2.0326D-03 0.0000D+00 0.0000D+00
RZ 0.0000D+00 0.0000D+00
LOADCASE CONVERGED AFTER 3 ITERATIONS
SECTION 1 COMPLETED
RESTART STAGE 5 COMPLETED
CPU = 0.797 FOR STAGE 5
Examples
Page 4-12
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
SPLINTER User Manual
RESTART STAGE 6 STARTED
LOAD CASE 1 LOAD CASE 2 LOAD CASE 3
-------------- -------------- --------------
NODE FD SKW DISPLACEMENT REACTION DISPLACEMENT REACTION DISPLACEMENT REACTION
---- -- --- ------------ -------- ------------ -------- ------------ --------
1 X 1.3154D-02 0.000D+00 1.3222D-02 0.000D+00 1.3291D-02 0.000D+00
Y 0.0000D+00 0.000D+00 0.0000D+00 0.000D+00 0.0000D+00 0.000D+00
Z -4.1911D-03 0.000D+00 -7.5398D-03 0.000D+00 -1.0889D-02 0.000D+00
RX 0.0000D+00 0.000D+00 0.0000D+00 0.000D+00 0.0000D+00 0.000D+00
RY 8.3014D-04 0.000D+00 8.3490D-04 0.000D+00 8.3972D-04 0.000D+00
RZ 0.0000D+00 0.000D+00 0.0000D+00 0.000D+00 0.0000D+00 0.000D+00
GLOBAL PILE DISPLACEMENTS
-------------------------
ELEMENT NUMBER 100 PILE CAP NODE 1 LOAD CASE 1 AXIAL 200. LATERAL 25. SELF
WEIGHT
--------------------- PILE TIP NODE 2 ---------------
DISTANCE FROM
PILE CAP X Y Z RX RY RZ
------------- ----------- ----------- ----------- ----------- ----------- -----------
0.0000 1.3154D-02 0.0000D+00 -4.1911D-03 0.0000D+00 8.3014D-04 0.0000D+00
3.0000 1.0621D-02 0.0000D+00 -4.0987D-03 0.0000D+00 8.1287D-04 0.0000D+00
5.0000 8.9835D-03 0.0000D+00 -4.0365D-03 0.0000D+00 7.8218D-04 0.0000D+00
7.5000 7.0497D-03 0.0000D+00 -3.9582D-03 0.0000D+00 7.2273D-04 0.0000D+00
11.3234 4.4664D-03 0.0000D+00 -3.8375D-03 0.0000D+00 5.9531D-04 0.0000D+00
15.5292 2.2958D-03 0.0000D+00 -3.7041D-03 0.0000D+00 4.2945D-04 0.0000D+00
20.1555 7.5413D-04 0.0000D+00 -3.5575D-03 0.0000D+00 2.5647D-04 0.0000D+00
25.2445 -9.7574D-05 0.0000D+00 -3.3976D-03 0.0000D+00 1.1383D-04 0.0000D+00
30.8423 -3.9194D-04 0.0000D+00 -3.2248D-03 0.0000D+00 2.6126D-05 0.0000D+00
37.0000 -3.8143D-04 0.0000D+00 -3.0399D-03 0.0000D+00 -1.0696D-05 0.0000D+00
45.3333 -2.2232D-04 0.0000D+00 -2.8027D-03 0.0000D+00 -2.0305D-05 0.0000D+00
54.5000 -5.6113D-05 0.0000D+00 -2.5598D-03 0.0000D+00 -1.2569D-05 0.0000D+00
62.5802 1.1380D-06 0.0000D+00 -2.3614D-03 0.0000D+00 -3.4631D-06 0.0000D+00
71.4683 6.8965D-06 0.0000D+00 -2.1633D-03 0.0000D+00 3.1580D-07 0.0000D+00
81.2453 1.5856D-06 0.0000D+00 -1.9716D-03 0.0000D+00 4.1241D-07 0.0000D+00
92.0000 -2.1026D-07 0.0000D+00 -1.7944D-03 0.0000D+00 4.5605D-08 0.0000D+00
106.9048 -5.5596D-08 0.0000D+00 -1.6083D-03 0.0000D+00 -2.0416D-08 0.0000D+00
123.3000 1.4860D-08 0.0000D+00 -1.4738D-03 0.0000D+00 2.4338D-09 0.0000D+00
TOTAL GLOBAL SOIL REACTIONS FOR ELEMENT 100 X Y Z
2.5000D+01 0.0000D+00 -2.9121D+02
RESTART STAGE 6 COMPLETED
CPU = 0.047 FOR STAGE 6
Examples
Page 4-13
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
SPLINTER User Manual
RESTART STAGE 8 STARTED
PILE FORCE AND STRESS REPORT
ELEMENT NUMBER 100 PILE CAP NODE 1 LOAD CASE 1 AXIAL 200. LATERAL 25. SELF
WEIGHT
--------------------- PILE TIP NODE 2 ---------------
DISTANCE FROM AXIAL BENDING COMBINED
PILE CAP FORCE XX SHEAR QY SHEAR QZ TORQUE XX MOMENT YY MOMENT ZZ STRESS STRESS STRESS
---------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- -----------
0.000D+00 -2.0000D+02 0.0000D+00 2.5000D+01 0.0000D+00 1.1994D-11 0.0000D+00 -1.3233D+02 1.1848D-11 -1.3233D+02
3.000D+00 -2.0222D+02 0.0000D+00 2.5000D+01 0.0000D+00 7.5509D+01 0.0000D+00 -1.3379D+02 7.4586D+01 -2.0838D+02
5.000D+00 -2.0370D+02 0.0000D+00 2.5000D+01 0.0000D+00 1.2584D+02 0.0000D+00 -1.3477D+02 1.2430D+02 -2.5908D+02
7.500D+00 -2.0530D+02 0.0000D+00 2.2413D+01 0.0000D+00 1.8617D+02 0.0000D+00 -1.3583D+02 1.8390D+02 -3.1973D+02
1.132D+01 -2.0681D+02 0.0000D+00 1.1960D+01 0.0000D+00 2.5104D+02 0.0000D+00 -1.3683D+02 2.4797D+02 -3.8480D+02
1.553D+01 -2.0723D+02 0.0000D+00 -1.6159D+00 0.0000D+00 2.6637D+02 0.0000D+00 -1.3711D+02 2.6312D+02 -4.0023D+02
2.016D+01 -2.0632D+02 0.0000D+00 -1.2010D+01 0.0000D+00 2.2416D+02 0.0000D+00 -1.3651D+02 2.2142D+02 -3.5793D+02
2.524D+01 -2.0378D+02 0.0000D+00 -1.5317D+01 0.0000D+00 1.4359D+02 0.0000D+00 -1.3483D+02 1.4183D+02 -2.7666D+02
3.084D+01 -1.9934D+02 0.0000D+00 -1.1434D+01 0.0000D+00 6.1957D+01 0.0000D+00 -1.3189D+02 6.1199D+01 -1.9309D+02
3.700D+01 -1.9268D+02 0.0000D+00 -3.1464D+00 0.0000D+00 1.6493D+01 0.0000D+00 -1.2748D+02 1.6291D+01 -1.4377D+02
4.533D+01 -1.7972D+02 0.0000D+00 -1.5524D+00 0.0000D+00 -1.3652D+00 0.0000D+00 -1.1891D+02 1.3485D+00 -1.2026D+02
5.450D+01 -1.6720D+02 0.0000D+00 -7.4386D-01 0.0000D+00 -9.7064D+00 0.0000D+00 -1.1062D+02 9.5878D+00 -1.2021D+02
6.258D+01 -1.5381D+02 0.0000D+00 5.4668D-01 0.0000D+00 -5.0768D+00 0.0000D+00 -1.0176D+02 5.0147D+00 -1.0678D+02
7.147D+01 -1.3776D+02 0.0000D+00 3.1766D-01 0.0000D+00 -5.0065D-01 0.0000D+00 -9.1145D+01 4.9453D-01 -9.1639D+01
8.125D+01 -1.1890D+02 0.0000D+00 3.5141D-02 0.0000D+00 3.7103D-01 0.0000D+00 -7.8665D+01 3.6649D-01 -7.9031D+01
9.200D+01 -9.7009D+01 0.0000D+00 -1.8896D-02 0.0000D+00 7.6386D-02 0.0000D+00 -6.4184D+01 7.5453D-02 -6.4259D+01
1.069D+02 -6.8201D+01 0.0000D+00 -2.9203D-03 0.0000D+00 -1.8282D-02 0.0000D+00 -4.5124D+01 1.8059D-02 -4.5142D+01
1.233D+02 4.2633D-14 0.0000D+00 -2.1684D-19 0.0000D+00 5.7386D-20 0.0000D+00 2.8207D-14 5.6685D-20 2.8207D-14
RESTART STAGE 8 COMPLETED
CPU = 0.047 FOR STAGE 8
Examples
Page 4-14
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
SPLINTER User Manual
SUMMARY OF FILES USED IN THIS RUN
---------------------------------
FILE FILE RECORDS WORDS NO. WRITE NO. READ PHYSICAL CURRENT
NO NAME ON FILE ON FILE OPERATIONS OPERATIONS FILE NAME DISPOSITION
1 IFCOOR 7 34 7 8 EXM132 RELEASED
2 IFELEM 1 9 1 4 EXM130 RELEASED
3 IFELEC 2 6 2 3 EXM131 RELEASED
4 IFMATE 3 14 4 6 EXM135 RELEASED
5 IFGEOM 3 30 3 11 EXM135 RELEASED
12 IFLOAD 14 127 14 14 EXM131 RELEASED
13 LEX 9 200 9 34 EXM135 RELEASED
15 LV 15 127 15 16 EXM135 RELEASED
16 IKFILE 1 33 1 40 EXM114 RELEASED
17 IFPART 9 87 11 122 EXM135 RELEASED
18 ISK 1 50 9 9 EXM112 RELEASED
20 IFELLD 3 84 15 21 EXM113 RELEASED
21 IBSIS 51 1632 51 51 EXM115 RELEASED
26 INDEC 1 2048 9 18 EXM117 RELEASED
28 IZINC 3 6144 9 9 EXM126 RELEASED
29 ISFIL 3 84 9 27 EXM135 RELEASED
32 IBSST 3 1848 3 3 EXM135 RELEASED
35 IADMIN 17 1599 98 36 EXM135 RELEASED
37 ICO1 17 9792 17 221 EXM115 RELEASED
38 IFPLLD 51 1632 54 156 EXM119 RELEASED
40 IFSOIL 3 1363 15 11 EXM131 RELEASED
41 IDPILE 3 1296 9 21 EXM115 RELEASED
42 ISFLST 1 28 6 8 EXM113 RELEASED
43 IZPILE 17 408 153 153 EXM119 RELEASED
44 ISREAC 3 1224 3 6 EXM115 RELEASED
54 ISTRIG 17 4896 153 306 EXM118 RELEASED
56 LEXSP 7 2498 20 144 EXM127 RELEASED
57 IKSOIL 17 9792 146 588 EXM118 RELEASED
58 IPLAST 68 1632 197 469 EXM119 RELEASED
61 IFSETS 13 46 13 0 EXM135 RELEASED
Examples
Page 4-15
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
SPLINTER User Manual
ASAS SYSTEM INFORMATION
-----------------------
MAIN PROGRAM PARAMETERS FOR STATICS AND STEADY STATE HEAT
---------------------------------------------------------
MIN. NODE NO. ON STRUCTURE 1 NO. OF EQUATIONS 6
MAX. NODE NO. ON STRUCTURE 2 NO. OF LOAD CASES 3
NO. OF NODES ON STRUCTURE 2 MAX. BANDWIDTH FOR AN INCORE SOLUTION 107
NO. OF COORDINATE DIMENSIONS 3 THE INCORE BANDWIDTH 6
NO. OF ELEMENTS 1 MAX. ELEMENT FREEDOM DIFFERENCE 12
NO. OF MATERIALS 1 THE OUT-OF-CORE BANDWIDTH 6
NO. OF SKEW SYSTEMS 0 NO. OF PARTITIONED EQUATIONS 1
NO. OF SKEWED NODES 0 NO. OF PARTITIONS IN BANDWIDTH 1
NO. OF GEOMETRIC PROPERTIES 1 MAX. NO. OF EQUATIONS IN ANY PARTITION 6
NO. OF GROUPS SPECIFIED 1 NO. OF PARTITIONED R.H.S. 3
MAX. NO. OF ELEMENT STRESSES 12 MAX. LOAD CASES IN ANY R.H.S. PARTITION 1
MAX. NO. OF ELEMENT FREEDOMS 12 NO. OF CONSTRAINT EQUATIONS 0
MAX. NO. OF NODES ON ANY ELEMENT 2 INDEPENDENT FDMS. IN CONSTRAINT EQTNS. 0
MAX. NO. OF ELEMENT GEOMETRIC PROPERTIES 11 NO. OF ERRORS IN RUN 0
MAX. NO. OF FREEDOMS AT ANY NODE 6 NO. OF WARNINGS IN RUN 0
TOTAL CPU TIME 1.609 TOTAL I/O TIME 0.0
**TOC TABLE OF CONTENTS
*****************
IDENTIFIER PAGE LINE
---------- ---- ----
**STGE01 2 47
**STGE02 13 9
**STGE03 13 21
**STGE04 13 29
**STGE05 13 37
**STGE06 22 30
**STGE07 26 40
**STGE08 26 48
**TAIL 31 46
Figure 4.2 Example 1, Selected SPLINTER Results
Examples
Page 4-16
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
Page 4-17
SPLINTER User Manual Examples
4.2. Example of a Pile Structure Interaction Analysis
This example consists of a simple four legged structure with a single pile connected to each leg, as shown in
Figure 4.3
Piles 1 and 2 have varying cross-sectional areas. The first 18.5m of pile has a diameter of 1m and thickness
5cm. The remainder of the pile is 0.9m in diameter and 2.5cm thick. Piles 3 and 4 are of constant cross-section
being 0.75m in diameter and 5cm thick.
The soil profile for the analysis is shown below.
Depth - m Description
0.0 - 4.0 Dense silty fine sand
6.0 Fine medium sand
6.0 - 18.5 Very soft to stiff normally consolidated clay
18.5 - 50.0 Stiff clay linearly increasing to hard clay
The structure is loaded to simulate a simple wind effect and this is applied to the piles as a component load.
Data units are KN and m.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-18
SPLINTER User Manual Examples
1 3
7 9
101 102 103
105
110
107 108 109
201 202 203
205
210
207 208 209
301
303
307
309
Figure 4.3 Pile structure interaction model
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-19
SPLINTER User Manual Examples
Curve Points
Depth in metres 1 2 3 4 5 6
0.0-4.0 P 0.0 130.0 170.0 190.0 21.0 21.0
Y 0.0 0.0045 0.012 0.2 0.35 1.0
4.0 P 0.0 105.0 175.0 71.0 71.0
Y 0.0 0.014 0.06 1.0 10.0
6.0 P 0.0 125.0 200.0 185.0 185.0
Y 0.0 0.014 0.06 1.0 10.0
6.0 P 0.0 330.0 600.0 180.0 180.0
Y 0.0 0.014 0.06 1.0 10.0
10-18.5 P 0.0 720.0 1220.0 750.0 750.0
Y 0.0 0.014 0.6 1.0 10.0
18.5 P 0.0 1320.0 2400.0 2400.0
Y 0.0 0.014 0.06 1.0
50.0 P 0.0 2075.0 3500.0 3500.0
Y 0.0 0.014 0.06 1.0
Soil force (P) KN/m
Deflection (Y) m
Table 4.4 P-Y Soil Data as supplied for 1.0m pile
Curve Points
Depth in metres 1 2 3
0.0 T 0.0 0.0
Z 0.0 1.0
8.0 T 0.0 170.0 170.0
Z 0.0 0.012 1.0
18.5 T 0.0 285.0 285.0
Z 0.0 0.012 1.0
26.0-50.0 T 0.0 320.0 320.0
Z 0.0 0.12 1.0
Soil force (T) KN/m
Displacement (Z) m
Table 4.5 T-Z Soil Data and supplied for 1.0m pile
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-20
SPLINTER User Manual Examples
Curve Points
1 2 3 3
T 0.0 0.0 9000.0 9000.0
Z -1.0 0.0 0.085 1.0
End force T KN
Displacement Z m
Table 4.6 End Bearing Soil Data as supplied for 1.0m pile
Notes on data for example 2.
1. For the fixed format data file only, the T-Z data for depth 0.0m includes a small value of 1.0 x 10-6 for T
to model negligible stiffness since zero cannot occur at the end of the line.
2. Both single point and layered curves are included.
3. The two methods for modelling soil discontinuities are shown on the P-Y data at depths 6.0m and 18.5m.
ie. if both curves at the discontinuity are single point definitions then they must be separated by a small
distance, if one of the curves defines a soil layer then the depths for the two curves may be the same.
4. Since the soil properties are for a pile of 1.0m in diameter, two soil definitions must be provided to
account for the differences in pile section for the four piles. The actual soil data is similar for both
definitions, only the factor commands are changed.
For piles 1 and 2, soil integer 12 utilises a PFAC and TFAC command at 18.5m depth to account for the
change in section from 1.0m diameter to 0.9m. Note that a dummy curve definition has to be included in
the T-Z data at 18.5m to allow the TFAC command to be operative over the depths 18.5m to 26m. The
end bearing data is similarly modified to account for the change in cross-sectional area. For piles 3 and 4,
soil integer 34, has a constant factor applied to both P-Y and T-Z data to change to that appropriate for a
0.75m diameter pile. The end bearing data is likewise modified. Note that if piles 3 and 4 had diameters
of 1.0m, PFAC and TFAC commands would have to be included with a factor of 1.0 since the factors
from soil 12 would still be operative.
5. The coordinates for the piles are in the same global system as that used for the jacket structure and thus
the pile caps are at - 7.42m. In order to define this as the mudline, a MUDD command is included so that
the pile caps are coincident with a depth of 0.0 on the soil data.
6. A DIVISION command is included in the preliminary data so that the subdivisions of the pile will be at
least every 2 diameters. By putting 0.0 as the second parameter on the DIVISION command, the
subdivision length will not increase with greater depth. For piles 1 and 2 which have variable section
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-21
SPLINTER User Manual Examples
properties, the diameter utilised will be the largest specified for that pile i.e. 1.0m. Note that smaller
subdivisions can occur if soil data, section changes or applied loading generate their own subdivisions.
7. The component load from the jacket has been multiplied by a factor of 1.5.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-22
SPLINTER User Manual Examples
The analysis is divided into three distinct phases.
Phase 1 component creation See Figure 4.5
All the data for the analysis, except for that relating to the foundation model i.e piles and soil, is assembled and
used in an ASASH component creation run. The LINK nodes defined represent the points on the jacket which
will be connected to the pile caps in the subsequent SPLINTER analysis. Note that it is the order of the LINK
nodes which defines which nodes on the jacket will be connected to each of the piles in SPLINTER.
The component creation run will generate 3 files.
EXM210
EXM250
TOWR35
These files store information about the jacket which will be utilised in the SPLINTER analysis. The names of
these files are derived from the project command where EXM2 represents the project name and the files
command where TOWR represents the name associated with the backing files for this run. (see note 1 after
Figure 4.4 )
For a substructure analysis, the component being created must be given a unique, 4 character identifier, by
supplying a COMPONENT command in the preliminary data. While not strictly necessary, the component
name has been chosen to be the same as the backing file names associated with this run for ease of identification
viz TOWR.
Phase 2 SPLINTER analysis See Figure 4.6
Data pertaining to the foundation model is prepared in much the same fashion as that required for a single pile
analysis with the following exceptions/amendments:-
1. The JOB command includes the statement OLD since this is a continuation of a previously defined
project.
2. The project name EXM2 must be the same as the project name used in the component creation run.
3. The name associated with the backing files must be different from that used in the component creation
run. In this case STR1 has been chosen.
4. A STRUCTURE command must be included to define a unique identifier for this analysis. In common
with the practice adopted for the component creation run, the same name as that supplied for the backing
files has been used viz STR1.
5. Note that if a second or subsequent SPLINTER analysis is to be carried out under the same project, both
the backing file name and the structure name must be modified to a unique 4 character identifier.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-23
SPLINTER User Manual Examples
6. A TOPO data block is included to define the connections to the jacket substructure. The first name
specified on the TOPO command must correspond to the name supplied on the COMPONENT command
in the component creation run. The second name provided, viz ASSM in the example, is used as an
identifier for the assembled component since it is possible to use a component more than once in a given
structure analysis. This assembled component name is utilised in both the component load data and in the
component recovery analysis (see phase 3).
Phase 3 component recovery See Figure 4.7
The SPLINTER analysis will provide displacements and forces at the pile cap and along the length of the pile. If
results for the jacket are also required, a component recovery is necessary. In practice, several SPLINTER
analyses (using different piles) may be carried out until a satisfactory behaviour at the pile caps is achieved
before recovering the jacket results.
For the recovery, only the PRELIMINARY data together with COMPONENT and SELECT LOADS commands
are required. The following points should be noted in the data:
1. The project name remains the same viz EXM2
2. The backing file name is unique from all previous runs.
3. The STRUCTURE command must define the name used in the SPLINTER analysis from which the
results are to be used. In this example, the structure is STR1. Note that this implies that the backing file
name is not the same as the STRUCTURE name which is a deviation from the procedure adopted for the
first two stages.
4. The COMPONENT command refers to the assembled component name defined on the TOPO data block
in the SPLINTER analysis. viz. ASSM.
The following flow path can be derived for the analysis, together with associated files generated.
Program Component/structure I.D. Description Files (see note)
EXMP10
ASAS TOWR Jacket model EXMP50
TOWR35
ASSM Assembled jacket
SPLINTER STR135
STR1 Foundation model +
assembled jacket
Foundation results
ASAS STR1/ASSM Jacket results RECO35
Figure 4.4 Flow Path for the Analysis of Example 2.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-24
SPLINTER User Manual Examples
Note
The file names given are those which are left after the successful completion of each phase. During the course
of any individual phase of the analysis, additional files are generated which are deleted as and when they are not
required by the program concerned. If a particular program stops, which can be subsequently restarted, any
additional files which have been generated must be preserved. Failure to comply with this requirement will
almost certainly cause the program to abort or give spurious results.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-25
SPLINTER User Manual Examples
SYSTEM DATA AREA 30000
JOB NEW COMP
PROJECT EXM2
FILES TOWR
TITLE SPLINTER MANUAL EXAMPLE 2
TEXT ************************************************
TEXT PILE STRUCTURE INTERACTION ANALYSIS
TEXT COMPONENT CREATION ASASH DATA FILE
TEXT 2 LOADCASES
TEXT LC1 SIMULATED WIND LOAD BY WAY OF 4 POINT LOADS
TEXT LC2 SELF WEIGHT
TEXT
TEXT UNITS KN , METRES
TEXT
TEXT **************************************************
COMPONENT TOWR
OPTIONS GOON
UNITS KN METRES
END
COOR
CART
1 -3.75 3.75 7.5
3 3.75 3.75 7.5
7 -3.75 -3.75 7.5
9 3.75 -3.75 7.5
101 -3.75 3.75 0.0
102 0.00 3.75 0.0
103 3.75 3.75 0.0
105 0.00 0.00 0.0
107 -3.75 -3.75 0.0
108 0.0 -3.75 0.0
109 3.75 -3.75 0.0
110 0.00 -1.50 0.0
201 -7.50 7.5 -27.42
202 0.00 7.5 -27.42
203 7.50 7.5 -27.42
205 0.00 0.0 -27.42
207 -7.50 -7.5 -27.42
208 0.00 -7.5 -27.42
209 7.50 -7.5 -27.42
210 0.00 -1.5 -27.42
END
ELEM
MATP 1
*
* ONLY FIRST ELEMENT HAS USER NUMBER DEFINED
* LET ALL OTHERS BE GENERATED SEQUENTIALLV
*
TUBE 1 3 1 1
TUBE 7 9 1
/
TUBE 101 102 1
RP 2 100
/
TUBE 102 103 1
RP 2 100
/
TUBE 107 108 1
RP 2 100
/
TUBE 108 109 1
RP 2 100
/
TUBE 1 7 1
RP 3 100
/
TUBE 3 9 1
RP 3 100
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-26
SPLINTER User Manual Examples
/
TUBE 1 101 2
RP 2 2
/
TUBE 7 107 2
RP 2 2
/
TUBE 101 201 2
RP 2 2
/
TUBE 107 207 2
RP 2 2
TUBE 1 107 1
TUBE 3 109 1
TUBE 7 109 1
TUBE 1 103 1
TUBE 101 207 1
TUBE 103 209 1
TUBE 107 209 1
TUBE 101 203 1
/
TUBE 102 105 3
RP 2 100
/
TUBE 105 110 3
RP 2 100
/
TUBE 110 108 3
RP 2 100
/
TUBE 105 205 4
RP 2 5
END
MATE
1 2.00E08 0.3 0.0 7.850
END
GEOM
1 TUBE 0.5 0.025
2 TUBE 0.75 0.05
3 TUBE 0.40 0.02
4 TUBE 0.40 0.03
END
LINK
ALL 201 203 207 209 205 210
END
LOAD 2
CASE 1 SIMULATED WIND LOADING
NODAL LO
X 500.00 1
X 500.00 3
X 500.00 101
X 500.00 103
END
CASE 2 SELF WEIGHT OF JACKET
BODY FOR
0.0 0.0 -9.81
END
STOP
Figure 4.5 Example 2, Data for creation of TOWR component
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-27
SPLINTER User Manual Examples
SYSTEM DATA AREA 30000
JOB OLD PILE
PROJECT EXM2
FILES STR1
TITLE SPLINTER MANUAL EXAMPLE 2
TEXT *************************************************
TEXT PILE STRUCTURE INTERACTION ANALYSIS
TEXT 4 PILES , ONE ON EACH CORNER OF JACKET
TEXT 2 PILES 0.75 DIAMETER x 0.05 THICKNESS
TEXT 2 PILES 1.00 DIAMETER x 0.050 THICKNESS FOR 18.5 M
TEXT 0.90 DIAMETER x 0.025 THICKNESS FOR REMAINDER
TEXT 1 LOADCASE
TEXT SIMULATED WIND LOAD AND S/W INPUT VIA COMPONENT LOAD
TEXT
TEXT DEFAULT CONVERGENCE
TEXT
TEXT SUBDIVISIONS SET TO REMAIN CONSTANT WITH DEPTH
TEXT AT 2 x DIAMETER (NOTE THAT SOIL SUBDIVISIONS
TEXT WILL OVERRIDE THIS WHERE APPROPRIATE)
TEXT
TEXT UNITS KN , METRES
TEXT
TEXT *************************************************
STRUCTURE STR1
OPTIONS GOON PRNO NODL CSOL SOIL
DIVISION 2.0 0.0
UNITS KN METRES
END
COOR
CART
201 -7.5 7.5 -27.42
203 7.5 7.5 -27.42
207 -7.5 -7.5 -27.42
209 7.5 -7.5 -27.42
301 -14.34 14.34 -57.42
303 14.34 14.34 -57.42
307 -14.34 -14.34 -57.42
309 14.34 -14.34 -57.42
END
PILE
*
* TWO PILES HAVE DIFFERENT SECTION PROPERTIES SO
* NEED TO HAVE TWO SOIL INTEGERS DEFINED
*
MATP 1
SOLP 12
TUBE 201 301 2 1
TUBE 203 303 2 2
SOLP 34
TUBE 207 307 1 3
TUBE 209 309 1 4
END
TOPO
TOWR ASSM 201 203 207 209 205 210
END
SOIL
*
* SET GLOBAL MUDLINE TO COINCIDE WITH STRUCTURAL DEFINITION
*
MUDD -27.42
12 P-Y 0.0 4.0
P 0.0 130.0 170.0 190.0 210.0 210.0
Y 0.0 0.0045 0.012 0.2 0.35 1.0
P-Y 4.0
P 0.0 105.0 175.0 71.0 71.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 6.0
P 0.0 125.0 200.0 185.0 185.0
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-28
SPLINTER User Manual Examples
Y 0.0 0.014 0.06 1.0 10.0
P-Y 6.01
P 0.0 330.0 600.0 180.0 180.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 10.0 18.5
P 0.0 720.0 1220.0 750.0 750.0
Y 0.0 0.014 0.06 1.0 10.0
PFAC 0.9
P-Y 18.5
P 0.0 1320.0 2400.0 2400.0
Y 0.0 0.014 0.06 1.0
P-Y 50.0
P 0.0 2075.0 3500.0 3500.0
Y 0.0 0.014 0.06 1.0
12 T-Z 0.0
T 0.0 0.0
Z 0.0 1.0
T-Z 8.0
T 0.0 170.0 170.0
Z 0.0 0.012 1.0
T-Z 18.5
T 0.0 285.0 285.0
Z 0.0 0.012 1.0
TFAC 0.9
T-Z 18.501
T 0.0 285.0 285.0
Z 0.0 0.012 1.0
T-Z 26.0 50.0
T 0.0 320.0 320.0
Z 0.0 0.012 1.0
12 ENDB
TFAC 0.81
T 0.0 0.0 9000.0 9000.0
Z -1.0 0.0 0.085 1.0
PFAC 0.75
TFAC 0.75
34 P-Y 0.0 4.0
P 0.0 130.0 170.0 190.0 210.0 210.0
Y 0.0 0.0045 0.012 0.2 0.35 1.0
P-Y 4.0
P 0.0 105.0 175.0 71.0 71.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 6.0
P 0.0 125.0 200.0 185.0 185.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 6.01
P 0.0 330.0 600.0 180.0 180.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 10.0 18.5
P 0.0 720.0 1220.0 750.0 750.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 18.5
P 0.0 1320.0 2400.0 2400.0
Y 0.0 0.014 0.06 1.0
P-Y 50.0
P 0.0 2075.0 3500.0 3500.0
Y 0.0 0.014 0.06 1.0
34 T-Z 0.0
T 0.0 0.0 1.0E-6
Z 0.0 1.0 10.0
T-Z 8.0
T 0.0 170.0 170.0
Z 0.0 0.012 1.0
T-Z 18.5
T 0.0 285.0 285.0
Z 0.0 0.012 1.0
T-Z 18.501
T 0.0 285.0 285.0
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-29
SPLINTER User Manual Examples
Z 0.0 0.012 1.0
T-Z 26.0 50.0
T 0.0 320.0 320.0
Z 0.0 0.012 1.0
34 ENDB
TFAC 0.5625
T 0.0 0.0 9000.0 9000.0
Z -1.0 0.0 0.085 1.0
END
MATE
1 2.00E08 0.3 0.0 7.850
END
GEOM
1 TUBE 0.75 0.05
*
* SECTION TWO IS STEPPED
*
2 TUBE 1.0 0.05 0 0 0 18.5
: STEP 0.9 0.025
END
LOAD 1
CASE 1 WIND LOAD PLUS STRUCTURE SELF WEIGHT
COMP LOAD
ASSM 1 1.50
ASSM 2 1.00
END
STOP
Figure 4.6 Example 2, Data for SPLINTER run
SYSTEM DATA AREA 30000
JOB OLD RECO
PROJECT EXMP
FILES RECO
TITLE SPLINTER MANUAL EXAMPLE 2
TEXT *************************************************
TEXT PILE STRUCTURE INTERACTION ANALYSIS
TEXT COMPONENT RECOVERY ASASH DATA FILE
TEXT l LOADCASE
TEXT SIMULATED WIND LOAD BY WAY OF 4 POINT LOADS
TEXT
TEXT UNITS KN , METRES
TEXT
TEXT *************************************************
STRUCTURE STR1
OPTIONS GOON
END
COMPONENT STR1 ASSM
STOP
Figure 4.7 Example 2, Data for Stress Recovery Run
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-30
SPLINTER User Manual Examples
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-31
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
1SPLINTER 13.01.00.0 (QA) 09:27 02-05-2001 PAGE 1
SPLINTER User Manual
*************************************************
PILE STRUCTURE INTERACTION ANALYSIS
4 PILES , ONE ON EACH CORNER OF JACKET
2 PILES 0.75 DIAMETER x 0.05 THICKNESS
2 PILES 1.00 DIAMETER x 0.050 THICKNESS FOR 18.5 M
0.90 DIAMETER x 0.025 THICKNESS FOR REMAINDER
1 LOADCASE
SIMULATED WIND LOAD AND S/W INPUT VIA COMPONENT LOAD
DEFAULT CONVERGENCE
SUBDIVISIONS SET TO REMAIN CONSTANT WITH DEPTH
AT 2 x DIAMETER (NOTE THAT SOIL SUBDIVISIONS
WILL OVERRIDE THIS WHERE APPROPRIATE)
UNITS KN , METRES
*************************************************
STRUCTURE STR1
A S A S EXECUTION CONTROL OPTIONS
------------------------------------
USER OPTIONS GOON PRNO NODL CSOL SOIL
DIVISION 2.0 0.0
RUN PARAMETERS
--------------
PROJECT NAME EXM2
PROJECT STATUS OLD
JOB TYPE PILE
STRUCTURE NAME STR1
FILE NAME STR1
SPLINTER PROGRAM PARAMETERS
---------------------------
MAXIMUM NUMBER OF ITERATIONS 10 (DEFAULT)
RELATIVE CONVERGENCE VALUE USED 5.000D-02 (DEFAULT)
BASIC PILE SUBDIVISION CRITERIA 2.000 PILE DIAMETERS
SUBDIVISION MODIFIER 0.000
PILES ARE SUBDIVIDED ON THE FOLLOWING BASIS
(1) AT POINTS OF APPLICATION OF EXTERNAL LOADS
(2) AT SOIL LAYER DIVISIONS
Examples
Page 4-32
(3) AT CHANGES IN PILE SECTION PROPERTIES
IN ADDITION,NO SUBDIVISION WILL BE LONGER THAN
THE BASIC SUBDIVISION PLUS A PERCENTAGE OF THE
DEPTH GIVEN BY THE SUBDIVISION MODIFIER
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
SPLINTER User Manual
RESULTANT FORCES IN GLOBAL DIRECTIONS
-------------------------------------
ABOUT ORIGIN X = 0.000D+00 Y = 0.000D+00 Z = 0.000D+00
LOAD CASE 1
FREEDOM FORCE MOMENT
------- --------- ---------
X 3.000D+03 4.323D+02
Y -7.105D-15 1.157D+04
Z -2.199D+03 -1.125D+04
S O I L P R O P E R T Y D A T A
---------------------------------------
---------------------------------------
SOIL ELEMENT PILE
NUMBER NUMBER DIAMETER CURVE SORTED VALUES
------ ------- -------- ----- --------------
12 1 1.0000D+00 P-Y 0.0000D+00 4.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
P -2.1000D+02 -2.1000D+02 -1.9000D+02 -1.7000D+02 -1.3000D+02 0.0000D+00
P 1.3000D+02 1.7000D+02 1.9000D+02 2.1000D+02 2.1000D+02
Y -1.0000D+00 -3.5000D-01 -2.0000D-01 -1.2000D-02 -4.5000D-03 0.0000D+00
Y 4.5000D-03 1.2000D-02 2.0000D-01 3.5000D-01 1.0000D+00
12 1 1.0000D+00 P-Y 4.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
P -7.1000D+01 -7.1000D+01 -1.7500D+02 -1.0500D+02 0.0000D+00 1.0500D+02
P 1.7500D+02 7.1000D+01 7.1000D+01
Y -1.0000D+01 -1.0000D+00 -6.0000D-02 -1.4000D-02 0.0000D+00 1.4000D-02
Y 6.0000D-02 1.0000D+00 1.0000D+01
12 1 1.0000D+00 P-Y 6.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
P -1.8500D+02 -1.8500D+02 -2.0000D+02 -1.2500D+02 0.0000D+00 1.2500D+02
P 2.0000D+02 1.8500D+02 1.8500D+02
Y -1.0000D+01 -1.0000D+00 -6.0000D-02 -1.4000D-02 0.0000D+00 1.4000D-02
Y 6.0000D-02 1.0000D+00 1.0000D+01
12 1 1.0000D+00 P-Y 6.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
P -1.8000D+02 -1.8000D+02 -6.0000D+02 -3.3000D+02 0.0000D+00 3.3000D+02
P 6.0000D+02 1.8000D+02 1.8000D+02
Y -1.0000D+01 -1.0000D+00 -6.0000D-02 -1.4000D-02 0.0000D+00 1.4000D-02
Y 6.0000D-02 1.0000D+00 1.0000D+01
12 1 1.0000D+00 P-Y 1.0000D+01 1.8500D+01 0.0000D+00 0.0000D+00 0.0000D+00
P -7.5000D+02 -7.5000D+02 -1.2200D+03 -7.2000D+02 0.0000D+00 7.2000D+02
P 1.2200D+03 7.5000D+02 7.5000D+02
Y -1.0000D+01 -1.0000D+00 -6.0000D-02 -1.4000D-02 0.0000D+00 1.4000D-02
Y 6.0000D-02 1.0000D+00 1.0000D+01
12 1 9.0000D-01 P-Y 1.8500D+01 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
P -2.1600D+03 -2.1600D+03 -1.1880D+03 0.0000D+00 1.1880D+03 2.1600D+03
P 2.1600D+03
Examples
Page 4-33
Y -1.0000D+00 -6.0000D-02 -1.4000D-02 0.0000D+00 1.4000D-02 6.0000D-02
Y 1.0000D+00
12 1 9.0000D-01 P-Y 5.0000D+01 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
P -3.1500D+03 -3.1500D+03 -1.8675D+03 0.0000D+00 1.8675D+03 3.1500D+03
P 3.1500D+03
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
Y -1.0000D+00 -6.0000D-02 -1.4000D-02 0.0000D+00 1.4000D-02 6.0000D-02
SPLINTER User Manual
Y 1.0000D+00
12 1 1.0000D+00 T-Z 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
T 0.0000D+00 0.0000D+00 0.0000D+00
Z -1.0000D+00 0.0000D+00 1.0000D+00
12 1 1.0000D+00 T-Z 8.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
T -1.7000D+02 -1.7000D+02 0.0000D+00 1.7000D+02 1.7000D+02
Z -1.0000D+00 -1.2000D-02 0.0000D+00 1.2000D-02 1.0000D+00
12 1 9.0000D-01 T-Z 1.8500D+01 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
T -2.8500D+02 -2.8500D+02 0.0000D+00 2.8500D+02 2.8500D+02
Z -1.0000D+00 -1.2000D-02 0.0000D+00 1.2000D-02 1.0000D+00
12 1 9.0000D-01 T-Z 1.8500D+01 0.0000D+00 0.0000D+00 0.0000D+00 0.0000D+00
T -2.5650D+02 -2.5650D+02 0.0000D+00 2.5650D+02 2.5650D+02
Z -1.0000D+00 -1.2000D-02 0.0000D+00 1.2000D-02 1.0000D+00
12 1 9.0000D-01 T-Z 2.6000D+01 5.0000D+01 0.0000D+00 0.0000D+00 0.0000D+00
T -2.8800D+02 -2.8800D+02 0.0000D+00 2.8800D+02 2.8800D+02
Z -1.0000D+00 -1.2000D-02 0.0000D+00 1.2000D-02 1.0000D+00
12 1 9.0000D-01 ENDB 0.0000D+00
T 0.0000D+00 0.0000D+00 7.2900D+03 7.2900D+03
Z -1.0000D+00 0.0000D+00 8.5000D-02 1.0000D+00
* WARNING * NO P-Y DATA CHANGE DEFINED AT 1.7607E+01
WHERE CHANGE OF DIAMETER OCCURS
* WARNING * NO T-Z DATA CHANGE DEFINED AT 1.7607E+01
WHERE CHANGE OF DIAMETER OCCURS
RESTART STAGE 1 COMPLETED
FREESTORE USED 30000
Examples
Page 4-34
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
RESTART STAGE 5 STARTED
SPLINTER User Manual
PILE CAP DISPLACEMENTS AND REACTIONS ITERATION REPORT
LOAD CASE NO. 1 ITERATION 1
------------------ -------------
RESULTANT PERCENTAGE RESULTANT PERCENTAGE
NODE FD DISPLACEMENT REACTION DISPLACEMENT CHANGE REACTION CHANGE
---- -- ------------ ----------- ------------ ---------- ----------- ----------
201 X 5.3618D-03 0.0000D+00
Y 2.6460D-03 0.0000D+00 9.2134D-03 0.0000D+00
Z 7.0097D-03 0.0000D+00
RX -6.6884D-04 0.0000D+00
RY 1.2171D-03 0.0000D+00 1.4094D-03 0.0000D+00
RZ -2.4032D-04 0.0000D+00
203 X 6.1637D-03 0.0000D+00
Y -2.6579D-03 0.0000D+00 1.1583D-02 0.0000D+00
Z -9.4401D-03 0.0000D+00
RX 9.8751D-04 0.0000D+00
RY 1.0770D-03 0.0000D+00 1.4835D-03 0.0000D+00
RZ -2.5616D-04 0.0000D+00
207 X 6.8881D-04 0.0000D+00
Y 2.8546D-03 0.0000D+00 5.5538D-03 0.0000D+00
Z 4.7140D-03 0.0000D+00
RX -5.8228D-04 0.0000D+00
RY 3.9604D-04 0.0000D+00 8.8678D-04 0.0000D+00
RZ -5.3895D-04 0.0000D+00
209 X 7.3521D-04 0.0000D+00
Y -2.5390D-03 0.0000D+00 8.6092D-03 0.0000D+00
Z -8.1934D-03 0.0000D+00
RX -2.8393D-06 0.0000D+00
RY -1.3743D-04 0.0000D+00 6.0617D-04 0.0000D+00
RZ -5.9038D-04 0.0000D+00
ITERATION 1 COMPLETED
Examples
Page 4-35
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
PILE CAP DISPLACEMENTS AND REACTIONS ITERATION REPORT
SPLINTER User Manual
LOAD CASE NO. 1 ITERATION 3
------------------ -------------
RESULTANT PERCENTAGE RESULTANT PERCENTAGE
NODE FD DISPLACEMENT REACTION DISPLACEMENT CHANGE REACTION CHANGE
---- -- ------------ ----------- ------------ ---------- ----------- ----------
201 X 5.6420D-03 0.0000D+00
Y 2.6922D-03 0.0000D+00 9.8254D-03 1.4793D-04 0.0000D+00 0.0000D+00
Z 7.5801D-03 0.0000D+00
RX -7.0222D-04 0.0000D+00
RY 1.2519D-03 0.0000D+00 1.4548D-03 -3.6428D-04 0.0000D+00 0.0000D+00
RZ -2.3649D-04 0.0000D+00
203 X 6.4403D-03 0.0000D+00
Y -2.8300D-03 0.0000D+00 1.1741D-02 -1.7730D-04 0.0000D+00 0.0000D+00
Z -9.3999D-03 0.0000D+00
RX 1.0177D-03 0.0000D+00
RY 1.1315D-03 0.0000D+00 1.5422D-03 -2.8301D-04 0.0000D+00 0.0000D+00
RZ -2.4967D-04 0.0000D+00
207 X 7.6872D-04 0.0000D+00
Y 2.9059D-03 0.0000D+00 5.9815D-03 3.8970D-04 0.0000D+00 0.0000D+00
Z 5.1713D-03 0.0000D+00
RX -5.7170D-04 0.0000D+00
RY 4.0109D-04 0.0000D+00 8.8824D-04 4.7826D-04 0.0000D+00 0.0000D+00
RZ -5.4887D-04 0.0000D+00
209 X 8.1005D-04 0.0000D+00
Y -2.6932D-03 0.0000D+00 8.6459D-03 -2.5177D-06 0.0000D+00 0.0000D+00
Z -8.1757D-03 0.0000D+00
RX 2.2063D-05 0.0000D+00
RY -1.1532D-04 0.0000D+00 6.0717D-04 1.8424D-04 0.0000D+00 0.0000D+00
RZ -5.9571D-04 0.0000D+00
LOADCASE CONVERGED AFTER 3 ITERATIONS
SECTION 1 COMPLETED
RESTART STAGE 5 COMPLETED
CPU = 0.516 FOR STAGE 5
Examples
Page 4-36
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
RESTART STAGE 6 STARTED
SPLINTER User Manual
LOAD CASE 1
--------------
NODE FD SKW DISPLACEMENT REACTION
---- -- --- ------------ --------
201 X 5.6420D-03 0.000D+00
Y 2.6922D-03 0.000D+00
Z 7.5801D-03 0.000D+00
RX -7.0222D-04 0.000D+00
RY 1.2519D-03 0.000D+00
RZ -2.3649D-04 0.000D+00
203 X 6.4403D-03 0.000D+00
Y -2.8300D-03 0.000D+00
Z -9.3999D-03 0.000D+00
RX 1.0177D-03 0.000D+00
RY 1.1315D-03 0.000D+00
RZ -2.4967D-04 0.000D+00
205 X 4.0002D-03 0.000D+00
Y 1.3009D-05 0.000D+00
Z -7.1293D-03 0.000D+00
RX -1.3086D-04 0.000D+00
RY 1.8403D-03 0.000D+00
RZ -6.8582D-04 0.000D+00
207 X 7.6872D-04 0.000D+00
Y 2.9059D-03 0.000D+00
Z 5.1713D-03 0.000D+00
RX -5.7170D-04 0.000D+00
RY 4.0109D-04 0.000D+00
RZ -5.4887D-04 0.000D+00
209 X 8.1005D-04 0.000D+00
Y -2.6932D-03 0.000D+00
Z -8.1757D-03 0.000D+00
RX 2.2063D-05 0.000D+00
RY -1.1532D-04 0.000D+00
RZ -5.9571D-04 0.000D+00
210 X 2.9805D-03 0.000D+00
Y 1.3165D-05 0.000D+00
Z -6.8263D-03 0.000D+00
RX -1.4147D-04 0.000D+00
RY 1.7607D-03 0.000D+00
RZ -6.9709D-04 0.000D+00
Examples
Page 4-37
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
GLOBAL PILE DISPLACEMENTS
SPLINTER User Manual
-------------------------
ELEMENT NUMBER 1 PILE CAP NODE 201 LOAD CASE 1 WIND LOAD PLUS STRUCTURE SELF
WEIGHT
--------------------- PILE TIP NODE 301 ---------------
DISTANCE FROM
PILE CAP X Y Z RX RY RZ
------------- ----------- ----------- ----------- ----------- ----------- -----------
0.0000 5.6420D-03 2.6922D-03 7.5801D-03 -7.0222D-04 1.2519D-03 -2.3649D-04
2.1014 3.5152D-03 1.2473D-03 7.4889D-03 -7.5443D-04 8.9146D-04 -2.2339D-04
4.2028 2.1795D-03 7.1880D-06 7.2682D-03 -6.0995D-04 5.3724D-04 -2.5732D-04
6.3042 1.4900D-03 -8.5414D-04 6.9947D-03 -4.2531D-04 2.7442D-04 -2.8582D-04
8.4056 1.2338D-03 -1.3421D-03 6.7193D-03 -2.5877D-04 1.1346D-04 -2.9501D-04
10.5070 1.2043D-03 -1.5381D-03 6.4739D-03 -1.3757D-04 3.7404D-05 -2.8347D-04
12.5070 1.2499D-03 -1.5604D-03 6.2764D-03 -6.9448D-05 1.4846D-05 -2.5852D-04
14.5070 1.2986D-03 -1.5091D-03 6.1116D-03 -3.6194D-05 1.4513D-05 -2.2812D-04
16.5070 1.3275D-03 -1.4370D-03 5.9735D-03 -2.3517D-05 2.0322D-05 -1.9883D-04
18.5000 1.3368D-03 -1.3697D-03 5.8581D-03 -2.0292D-05 2.4694D-05 -1.7459D-04
19.4379 1.3212D-03 -1.3302D-03 5.7538D-03 -2.0015D-05 2.6917D-05 -1.5090D-04
21.4080 1.2790D-03 -1.2687D-03 5.5614D-03 -2.0208D-05 2.6417D-05 -1.1227D-04
23.3780 1.2378D-03 -1.2281D-03 5.4023D-03 -1.8775D-05 2.1810D-05 -8.5326D-05
25.3481 1.2050D-03 -1.2002D-03 5.2766D-03 -1.6014D-05 1.6834D-05 -6.6995D-05
27.3182 1.1822D-03 -1.1809D-03 5.1850D-03 -1.3268D-05 1.3174D-05 -5.5023D-05
29.4196 1.1682D-03 -1.1685D-03 5.1256D-03 -1.1335D-05 1.1038D-05 -4.7786D-05
31.5210 1.1636D-03 -1.1647D-03 5.1058D-03 -1.0694D-05 1.0399D-05 -4.5448D-05
TOTAL GLOBAL SOIL REACTIONS FOR ELEMENT 1 X Y Z
8.9253D+02 -3.6713D+02 3.2265D+03
Examples
Page 4-38
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
GLOBAL PILE DISPLACEMENTS
SPLINTER User Manual
-------------------------
ELEMENT NUMBER 2 PILE CAP NODE 203 LOAD CASE 1 WIND LOAD PLUS STRUCTURE SELF
WEIGHT
--------------------- PILE TIP NODE 303 ---------------
DISTANCE FROM
PILE CAP X Y Z RX RY RZ
------------- ----------- ----------- ----------- ----------- ----------- -----------
0.0000 6.4403D-03 -2.8300D-03 -9.3999D-03 1.0177D-03 1.1315D-03 -2.4967D-04
2.1014 4.3809D-03 -9.4278D-04 -9.1076D-03 9.2258D-04 8.9425D-04 -2.3484D-04
4.2028 2.9517D-03 4.8824D-04 -8.7808D-03 6.7609D-04 5.9429D-04 -2.7274D-04
6.3042 2.1128D-03 1.3806D-03 -8.4522D-03 4.3216D-04 3.4450D-04 -3.0538D-04
8.4056 1.7133D-03 1.8184D-03 -8.1416D-03 2.4080D-04 1.7265D-04 -3.1698D-04
10.5070 1.5795D-03 1.9436D-03 -7.8601D-03 1.1717D-04 7.6380D-05 -3.0562D-04
12.5070 1.5650D-03 1.9082D-03 -7.6207D-03 5.5504D-05 3.6334D-05 -2.7909D-04
14.5070 1.5817D-03 1.8160D-03 -7.4070D-03 2.9670D-05 2.4151D-05 -2.4623D-04
16.5070 1.5950D-03 1.7179D-03 -7.2170D-03 2.2299D-05 2.3526D-05 -2.1428D-04
18.5000 1.5962D-03 1.6338D-03 -7.0496D-03 2.1735D-05 2.5236D-05 -1.8766D-04
19.4379 1.5720D-03 1.5829D-03 -6.8941D-03 2.2652D-05 2.6443D-05 -1.6145D-04
21.4080 1.5121D-03 1.5010D-03 -6.5990D-03 2.3035D-05 2.5655D-05 -1.1837D-04
23.3780 1.4520D-03 1.4413D-03 -6.3443D-03 2.0338D-05 2.1413D-05 -8.7704D-05
25.3481 1.3999D-03 1.3945D-03 -6.1296D-03 1.6211D-05 1.6405D-05 -6.5994D-05
27.3182 1.3582D-03 1.3567D-03 -5.9551D-03 1.2343D-05 1.2236D-05 -5.0603D-05
29.4196 1.3251D-03 1.3255D-03 -5.8132D-03 9.3552D-06 9.2108D-06 -3.9276D-05
31.5210 1.3027D-03 1.3040D-03 -5.7162D-03 7.5596D-06 7.4275D-06 -3.1948D-05
TOTAL GLOBAL SOIL REACTIONS FOR ELEMENT 2 X Y Z
1.2118D+03 6.3956D+02 -4.3002D+03
TREE OF COMPONENTS IN STRUCTURE STR1
------------------------------------
2 STR1 --- 1 ASSM
(TOWR)
KEY -
COMPONENTS ARE SHOWN TOGETHER WITH THEIR (UNIQUE) NUMBER AND MASTER COMPONENT TYPE THUS
--- 10 COMP
(MCM1)
INDICATES COMPONENT NAME COMP
Examples
Page 4-39
(UNIQUE) NUMBER 10
MASTER COMPONENT TYPE MCM1
RESTART STAGE 6 COMPLETED
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
CPU = 0.063 FOR STAGE 6
SPLINTER User Manual
RESTART STAGE 8 STARTED
PILE FORCE AND STRESS REPORT
ELEMENT NUMBER 1 PILE CAP NODE 201 LOAD CASE 1 WIND LOAD PLUS STRUCTURE SELF
WEIGHT
--------------------- PILE TIP NODE 301 ---------------
DISTANCE FROM AXIAL BENDING COMBINED
PILE CAP FORCE XX SHEAR QY SHEAR QZ TORQUE XX MOMENT YY MOMENT ZZ STRESS STRESS STRESS
---------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- -----------
0.000D+00 3.3441D+03 1.4241D+02 3.7151D+02 -9.8879D+01 1.0016D+02 -6.0898D+02 2.2410D+04 1.8280D+04 4.0689D+04
2.101D+00 3.3155D+03 1.0944D+02 1.0452D+02 -9.6660D+01 5.5353D+02 -3.2866D+02 2.2218D+04 1.9067D+04 4.1285D+04
4.203D+00 3.2318D+03 6.2687D+01 -4.4628D+01 -9.0770D+01 5.5837D+02 -1.4791D+02 2.1657D+04 1.7109D+04 3.8766D+04
6.304D+00 3.0966D+03 5.1193D+01 -6.1579D+01 -8.2276D+01 4.3736D+02 -2.9718D+01 2.0751D+04 1.2984D+04 3.3735D+04
8.406D+00 2.9128D+03 2.2985D+01 -7.2264D+01 -7.2085D+01 2.7995D+02 4.2414D+01 1.9519D+04 8.3865D+03 2.7906D+04
1.051D+01 2.6956D+03 1.5014D+00 -5.7270D+01 -6.1498D+01 1.3522D+02 6.0146D+01 1.8064D+04 4.3835D+03 2.2448D+04
1.251D+01 2.4708D+03 -7.5466D+00 -3.3839D+01 -5.1865D+01 4.4960D+01 4.8634D+01 1.6557D+04 1.9617D+03 1.8519D+04
1.451D+01 2.2289D+03 -8.6156D+00 -1.4894D+01 -4.2716D+01 -1.3292D-01 2.9960D+01 1.4936D+04 8.8739D+02 1.5824D+04
1.651D+01 1.9704D+03 -6.4890D+00 -3.2582D+00 -3.4044D+01 -1.4616D+01 1.4172D+01 1.3204D+04 6.0300D+02 1.3807D+04
1.850D+01 1.6967D+03 -3.8739D+00 1.9009D+00 -2.5811D+01 -1.3198D+01 4.0297D+00 2.4689D+04 9.4343D+02 2.5633D+04
1.944D+01 1.5630D+03 -2.8530D+00 2.6146D+00 -2.2203D+01 -1.0890D+01 9.3262D-01 2.2744D+04 7.4725D+02 2.3491D+04
2.141D+01 1.3087D+03 -6.0272D-01 2.5321D+00 -1.6418D+01 -4.6768D+00 -1.5874D+00 1.9043D+04 3.3765D+02 1.9381D+04
2.338D+01 1.0549D+03 2.2863D-01 1.2904D+00 -1.1862D+01 -9.4070D-01 -1.4126D+00 1.5350D+04 1.1603D+02 1.5466D+04
2.535D+01 8.0054D+02 3.1279D-01 3.6110D-01 -8.2165D+00 3.8174D-01 -6.8067D-01 1.1649D+04 5.3352D+01 1.1702D+04
2.732D+01 5.4425D+02 1.7395D-01 -4.2745D-02 -5.2100D+00 4.6936D-01 -1.8257D-01 7.9196D+03 3.4430D+01 7.9540D+03
2.942D+01 2.7108D+02 4.3900D-02 -1.1195D-01 -2.4755D+00 1.7995D-01 2.4729D-03 3.9446D+03 1.2303D+01 3.9569D+03
3.152D+01 4.3769D-12 6.2350D-13 -1.9185D-13 5.3735D-14 -8.1712D-14 -5.6418D-14 6.3690D-11 6.7884D-12 7.0479D-11
AXIAL PILE CAPACITY SAFETY FACTOR 1.9677D+00 (TENSION)
Examples
Page 4-40
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
PILE FORCE AND STRESS REPORT
SPLINTER User Manual
ELEMENT NUMBER 2 PILE CAP NODE 203 LOAD CASE 1 WIND LOAD PLUS STRUCTURE SELF
WEIGHT
--------------------- PILE TIP NODE 303 ---------------
DISTANCE FROM AXIAL BENDING COMBINED
PILE CAP FORCE XX SHEAR QY SHEAR QZ TORQUE XX MOMENT YY MOMENT ZZ STRESS STRESS STRESS
---------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- -----------
0.000D+00 -4.4944D+03 -7.3684D+01 4.0465D+02 -1.0745D+02 1.0019D+02 2.2750D+02 -3.0118D+04 7.3629D+03 -3.7481D+04
2.101D+00 -4.4590D+03 -4.7701D+01 1.1962D+02 -1.0504D+02 6.0392D+02 9.5521D+01 -2.9881D+04 1.8110D+04 -4.7990D+04
4.203D+00 -4.3558D+03 -2.1572D+01 -4.7511D+01 -9.8660D+01 6.1518D+02 2.5973D+01 -2.9189D+04 1.8237D+04 -4.7427D+04
6.304D+00 -4.1894D+03 -1.6234D+01 -6.6708D+01 -8.9456D+01 4.8467D+02 -1.2673D+01 -2.8074D+04 1.4360D+04 -4.2435D+04
8.406D+00 -3.9641D+03 -4.8340D+00 -7.9491D+01 -7.8420D+01 3.1223D+02 -3.1660D+01 -2.6564D+04 9.2954D+03 -3.5860D+04
1.051D+01 -3.6986D+03 2.5755D+00 -6.3542D+01 -6.6963D+01 1.5211D+02 -3.0494D+01 -2.4785D+04 4.5949D+03 -2.9380D+04
1.251D+01 -3.4246D+03 4.7544D+00 -3.7820D+01 -5.6550D+01 5.1506D+01 -2.1115D+01 -2.2949D+04 1.6488D+03 -2.4598D+04
1.451D+01 -3.1310D+03 4.1218D+00 -1.6818D+01 -4.6675D+01 8.2844D-01 -1.1476D+01 -2.0981D+04 3.4080D+02 -2.1322D+04
1.651D+01 -2.8184D+03 2.6665D+00 -3.8292D+00 -3.7332D+01 -1.5767D+01 -4.6279D+00 -1.8887D+04 4.8671D+02 -1.9373D+04
1.850D+01 -2.4886D+03 1.3803D+00 1.9845D+00 -2.8483D+01 -1.4524D+01 -8.1840D-01 -3.6212D+04 9.9450D+02 -3.7207D+04
1.944D+01 -2.3282D+03 9.4970D-01 2.8102D+00 -2.4619D+01 -1.2062D+01 2.4172D-01 -3.3878D+04 8.2478D+02 -3.4703D+04
2.141D+01 -2.0250D+03 9.1704D-02 2.7920D+00 -1.8476D+01 -5.2447D+00 8.6578D-01 -2.9467D+04 3.6341D+02 -2.9830D+04
2.338D+01 -1.7255D+03 -1.5863D-01 1.4402D+00 -1.3728D+01 -1.0905D+00 5.9321D-01 -2.5109D+04 8.4871D+01 -2.5194D+04
2.535D+01 -1.4284D+03 -1.3976D-01 4.1114D-01 -1.0048D+01 4.0169D-01 2.3990D-01 -2.0785D+04 3.1986D+01 -2.0817D+04
2.732D+01 -1.1324D+03 -6.4324D-02 -4.1796D-02 -7.1729D+00 5.1522D-01 4.4154D-02 -1.6478D+04 3.5352D+01 -1.6513D+04
2.942D+01 -8.2057D+02 -1.0668D-02 -1.2287D-01 -4.7797D+00 1.9989D-01 -1.0849D-02 -1.1940D+04 1.3686D+01 -1.1954D+04
3.152D+01 5.9117D-12 1.3323D-13 9.5923D-14 3.9080D-14 -1.9207D-13 -1.5883D-13 8.6023D-11 1.7039D-11 1.0306D-10
AXIAL PILE CAPACITY SAFETY FACTOR 3.0861D+00 (COMPRESSION)
RESTART STAGE 8 COMPLETED
CPU = 0.063 FOR STAGE 8
Figure 4.8 Example 2, Selected SPLINTER Results
Examples
Page 4-41
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
Page 4-42
SPLINTER User Manual Examples
4.3. Group Pile Analysis
The analysis consists of a group of 4 piles rigidly connected at the pile cap. All the piles have similar constant
section properties. The soil profile is the same as that used in example 1 viz
Depth-ft Description
0.37 Varying from fine-medium sand to medium-dense sand
37-54.5 Very sandy, stiff clay
54.5-215 Varying from grey fine-medium sand to medium-dense sand
The pile group is subjected to both lateral and axial loading at the pile cap.
The data is in units of kips and feet
Notes on data for example 3.
1. The first 5 feet of soil is subject to local scour and is modelled by starting the P-Y and T-Z data at this
depth.
2. For the fixed format data file only, the T-Z data for depth 5 feet includes a small value of 1.0 x 10-6 for T
to model negligible stiffness since zero cannot occur at the end of the line.
3. Both single point and layered curves are included.
4. The two methods for modelling soil discontinuities are shown on the P-Y data at depths 7.5ft and 37ft. ie
if both curves at the discontinuity are single point definitions then they must be separated by a small
distance; if one of the curves defines a soil layer then the depths for the two curves may be the same.
5. All displacement terms in the P-Y and T-Z data are in units of inches. Since the analysis is to be carried
out in units of feet YFAC and ZFAC commands are included to adjust the terms accordingly.
6. The P data is supplied in terms of lbs/in. A PFAC command precedes the P-Y data to convert to Kips/ft.
Similarly, a TFAC command precedes the T-Z data to convert the T information from Kips/square foot to
Kips/ft. A second TFAC command precedes the ENDB data since the supplied information is already in
the correct units.
7. The pile group is being modelled as rigidly connected at the pile cap and thus a node is defined to
represent the location of the pile cap connection. Since no connecting structure is supplied, a dummy
element (number 10) is provided in order to locate the pile cap node. This element is given a soil integer
of 0 to indicate that it does not represent a pile element. A group number of 9999 is assigned to this
element in order that it will not appear in the results file. Note that this group does not have to be defined
in the PGRP data.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-43
SPLINTER User Manual Examples
8. Two different forms of soil elastic modulus variation have been illustrated:
(i). For the lateral behaviour, the modulus varies linearly with depth with a slope of 20 kips/foot2/foot.
(ii). For the axial behaviour, the modulus varies linearly to a depth of 92 feet, where it becomes
constant with a value of 2860 kips/foot2. Note that T-Z had to be defined at a depth of 92 feet to
comply with the input requirements.
SYSTEM DATA AREA 30000
JOB NEW PILE
PROJECT EXM3
TITLE SPLINTER MANUAL EXAMPLE 3
TEXT *************************************************
TEXT FOUR PILE GROUP PILE ANALYSIS
TEXT ALL PILES HAVE CONSTANT DIAMETER 3.00 FEET
TEXT CONSTANT THICKNESS .17 FEET
TEXT LENGTH OF PILES 123.30 FEET
TEXT PILE GROUP RIGIDLY CONNECTED AT PILE CAP
TEXT 2 LOADCASES
TEXT LC 1 AXIAL LOAD 800 KIPS
TEXT LAT LOAD 100 KIPS
TEXT LC,2 AXIAL LOAD 1600 KIPS
TEXT LAT LOAD 100 KIPS
TEXT
TEXT UNITS KIPS , FEET
TEXT
TEXT *************************************************
OPTIONS GOON NOBL SOIL PGRP FORF
UNITS KIPS FEET
END
COOR
CART
1 0.0 0.0 0.0
2 0.0 0.0 -123.3
3 6.0 6.0 0.0
4 6.0 6.0 -123.3
5 12.0 12.0 0.0
6 12.0 12.0 -123.3
7 0.0 12.0 0.0
8 0.0 12.0 -123.3
10 4.0 8.0 0.0
11 4.0 8.0 10.0
END
PILE
MATP 1
SOLP 1
*
* PILE GROUP 2 DEFINED
*
GROUP 2
TUBE 1 2 1 100
TUBE 3 4 1
TUBE 5 6 1
TUBE 7 8 1
*
* DUMMY ELEMENT PUT IN TO DEFINE PILE CAP
* ASSIGN GROUP NUMBER 9999 SO THAT DOES NOT PRINT
* ASSIGN SOIL ZERO TO INDICATE NOT A PILE
*
GROUP 9999
SOLP 0
TUBE 10 11 1 999
END
PGRP
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-44
SPLINTER User Manual Examples
*
* RIGIDLY CONNECTED PILE GROUP
*
2 CONN 10 MAXD 15.0
END
SOIL
*
* FACTOR CARDS TO CONVERT TO FEET AND KIPS
*
YFAC 0.08333
ZFAC 0.08333
PFAC 0.012
*
* HORIZONTAL ELASTIC SOIL PROPERTY
*
1 MAPY 200.0 0.4 20.0
1 P-Y 5.0
P 0.0 0.8 0.9 1.0 1.1 1.3
: 1.3
Y 0.0 0.2 0.4 0.6 0.975 1.35
: 10.0
P-Y 7.5
P 0.0 62.7 125.4 188.1 235.6 264.0
: 285.0 327.4 369.7 369.7
Y 0.0 0.035 0.07 0.105 0.27 0.435
: 0.6 0.975 1.35 10.0
P-Y 7.501
P 0.0 63.0 125.9 188.9 236.6 265.1
: 286.2 328.8 371.5 371.5
Y 0.0 0.035 0.07 0.105 0.27 0.435
: 0.6 0.975 1.35 10.0
P-Y 37.0
P 0.0 2036.1 4072.2 6108.3 7512.5 8677.1
: 9692.8 12600.0 15508.4 15508.4
Y 0.0 0.076 0.153 0.229 0.353 0.476
: 0.6 0.975 1.35 10.0
P-Y 37.0 54.5
P 0.0 990.0 1575.0 1980.0 2250.0 2790.0
: 3060.0 3240.0 3240.0
Y 0.0 0.225 0.45 0.675 0.9 1.5
: 2.1 2.7 10.0
P-Y 54.5
P 0.0 5114.2 10228.5 15342.7 16599.7 17761.1
: 18845.6 24499.3 30153.0 30153.0
Y 0.0 0.130 0.261 0.391 0.461 0.530
: 0.6 0.975 1.35 10.0
P-Y 215.0
P 0.0 16727.5 33454.9 50182.4 51801.7 53367.9
: 54885.9 71351.6 87817.4 87817.4
Y 0.0 0.166 0.332 0.498 0.532 0.566
: 0.6 0.975 1.35 10.0
*
* SECOND FACTOR CARD TO ACCOUNT FOR DIAMETER OF PILE
*
TFAC 9.4248
*
* VERTICAL ELASTIC PROPERTY
*
1 MATZ 100.0 0.4 30.0 92.0
1 T-Z 5.0
T 0.0 0.0 1.0E-6
Z 0.0 10.0 12.0
T-Z 37.0
T -0.59 -0.59 0.0 0.82 0.82
Z -10.0 -0.144 0.0 0.144 10.0
T-Z 37.0 54.5
T 0.0 1.0 1.0
Z 0.0 0.144 10.0
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-45
SPLINTER User Manual Examples
T-Z 54.5
T -0.82 -0.82 0.0 1.15 1.15
Z -10.0 -0.144 0.0 0.144 10.0
T-Z 92.0 127.0
T -1.43 -1.43 0.0 2.0 2.0
Z -10.0 -0.144 0.0 0.144 10.0
T-Z 127.0 215.0
T -2.0 -2.0 0.0 2.0 2.0
Z -10.0 -0.144 0.0 0.144 10.0
*
* RESET FACTOR TO ONE SINCE ENDB ALREADY IN CORRECT UNITS
*
TFAC 1.0
1 ENDB
T 0.0 0.0 827.2 1042.0 1192.6 1312.5
: 1413.7 1413.7
Z -10.0 0.0 0.36 0.72 1.08 1.44
: 1.8 10.0
END
MATE
1 4.320D06 0.3 0.0 1.52E-2
END
GEOM
1 TUBE 3.0 0.17
END
LOAD 2
CASE 1 AXIAL 800. LATERAL 100.
NODAL LO
X 100.0 10
Z -800.0 10
END
CASE 2 AXIAL 1600. LATERAL 100.
NODAL LO
X 100.0 10
Z -1600.0 10
END
STOP
Figure 4.1 Example 3, Group Pile SPLINTER Data
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-46
SPLINTER User Manual Examples
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-47
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
1SPLINTER 13.01.00.0 (QA) 13:41 02-05-2001 PAGE 1
SPLINTER User Manual
*************************************************
FOUR PILE GROUP PILE ANALYSIS
ALL PILES HAVE CONSTANT DIAMETER 3.00 FEET
CONSTANT THICKNESS .17 FEET
LENGTH OF PILES 123.30 FEET
PILE GROUP RIGIDLY CONNECTED AT PILE CAP
2 LOADCASES
LC 1 AXIAL LOAD 800 KIPS
LAT LOAD 100 KIPS
LC,2 AXIAL LOAD 1600 KIPS
LAT LOAD 100 KIPS
UNITS KIPS , FEET
*************************************************
A S A S EXECUTION CONTROL OPTIONS
------------------------------------
USER OPTIONS GOON NOBL SOIL PGRP FORF
RUN PARAMETERS
--------------
PROJECT NAME EXM3
PROJECT STATUS NEW
JOB TYPE PILE
STRUCTURE NAME EXM3
FILE NAME EXM3
SPLINTER PROGRAM PARAMETERS
---------------------------
MAXIMUM NUMBER OF ITERATIONS 10 (DEFAULT)
RELATIVE CONVERGENCE VALUE USED 5.000D-02 (DEFAULT)
BASIC PILE SUBDIVISION CRITERIA 1.000 PILE DIAMETERS (DEFAULT)
SUBDIVISION MODIFIER 0.100 (DEFAULT)
PILES ARE SUBDIVIDED ON THE FOLLOWING BASIS
(1) AT POINTS OF APPLICATION OF EXTERNAL LOADS
(2) AT SOIL LAYER DIVISIONS
(3) AT CHANGES IN PILE SECTION PROPERTIES
IN ADDITION,NO SUBDIVISION WILL BE LONGER THAN
THE BASIC SUBDIVISION PLUS A PERCENTAGE OF THE
Examples
Page 4-48
DEPTH GIVEN BY THE SUBDIVISION MODIFIER
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
RESULTANT FORCES IN GLOBAL DIRECTIONS
SPLINTER User Manual
-------------------------------------
ABOUT ORIGIN X = 0.000D+00 Y = 0.000D+00 Z = 0.000D+00
LOAD CASE 1 LOAD CASE 2
FREEDOM FORCE MOMENT FORCE MOMENT
------- --------- --------- --------- ---------
X 1.000D+02 -6.400D+03 1.000D+02 -1.280D+04
Y 0.000D+00 3.200D+03 0.000D+00 6.400D+03
Z -8.000D+02 -8.000D+02 -1.600D+03 -8.000D+02
CROSS CHECKS ON PILE GROUP DATA
-------------------------------
INTERACTION
GROUP TYPE INTERACTION DISTANCE PILES
----- ---- ----------- ----------- -----
2 CONN YES 15.000 100 101 102 103
9999 NOIN NO 0.000 999
RESTART STAGE 1 COMPLETED
FREESTORE USED 30000
CPU = 0.391 FOR STAGE 1
PILE CAP DISPLACEMENTS AND REACTIONS ITERATION REPORT
LOAD CASE NO. 1 ITERATION 1
------------------ -------------
RESULTANT PERCENTAGE RESULTANT PERCENTAGE
NODE FD DISPLACEMENT REACTION DISPLACEMENT CHANGE REACTION CHANGE
---- -- ------------ ----------- ------------ ---------- ----------- ----------
1 X 4.9765D-03 2.3400D+01
Y 4.3375D-04 9.6015D-01 5.7231D-03 1.6844D+02
Z -2.7929D-03 -1.6680D+02
RX -2.5122D-05 2.1156D+00
RY 8.1645D-05 -2.2069D+02 9.3303D-05 2.2071D+02
RZ -3.7528D-05 -1.9383D+00
3 X 5.2017D-03 2.4680D+01
Y 2.0859D-04 -3.2005D-01 6.2362D-03 2.0654D+02
Z -3.4335D-03 -2.0506D+02
RX -2.5122D-05 -1.1382D+01
RY 8.1645D-05 -2.3419D+02 9.3303D-05 2.3448D+02
RZ -3.7528D-05 -1.9383D+00
Examples
Page 4-49
5 X 5.4268D-03 2.5960D+01
Y -1.6582D-05 -1.6003D+00 6.7859D-03 2.4471D+02
Z -4.0741D-03 -2.4332D+02
RX -2.5122D-05 -2.4880D+01
RY 8.1645D-05 -2.4769D+02 9.3303D-05 2.4894D+02
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
RZ -3.7528D-05 -1.9383D+00
SPLINTER User Manual
7 X 5.4268D-03 2.5960D+01
Y 4.3375D-04 9.6015D-01 6.2621D-03 1.8663D+02
Z -3.0944D-03 -1.8481D+02
RX -2.5122D-05 2.1156D+00
RY 8.1645D-05 -2.4769D+02 9.3303D-05 2.4771D+02
RZ -3.7528D-05 -1.9383D+00
ITERATION 1 COMPLETED
Examples
Page 4-50
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
PILE CAP DISPLACEMENTS AND REACTIONS ITERATION REPORT
SPLINTER User Manual
LOAD CASE NO. 1 ITERATION 4
------------------ -------------
RESULTANT PERCENTAGE RESULTANT PERCENTAGE
NODE FD DISPLACEMENT REACTION DISPLACEMENT CHANGE REACTION CHANGE
---- -- ------------ ----------- ------------ ---------- ----------- ----------
1 X 8.3574D-03 2.7948D+01
Y 5.6433D-04 3.6160D-01 9.0229D-03 9.7698D-04 1.7445D+02 -1.2567D-04
Z -3.3536D-03 -1.7220D+02
RX -1.8351D-05 3.2915D+00
RY 1.0868D-04 -2.9372D+02 1.1949D-04 1.2467D-03 2.9375D+02 2.8529D-04
RZ -4.6166D-05 -2.3845D+00
3 X 8.6344D-03 1.8577D+01
Y 2.8734D-04 -1.2288D+00 9.5695D-03 9.3999D-04 1.9174D+02 1.2108D-04
Z -4.1158D-03 -1.9083D+02
RX -1.8351D-05 -1.3379D+01
RY 1.0868D-04 -2.2120D+02 1.1949D-04 1.2467D-03 2.2162D+02 1.8494D-03
RZ -4.6166D-05 -2.3845D+00
5 X 8.9114D-03 2.9114D+01
Y 1.0338D-05 -2.4937D+00 1.0159D-02 9.0871D-04 2.6460D+02 2.0357D-04
Z -4.8780D-03 -2.6298D+02
RX -1.8351D-05 -2.7952D+01
RY 1.0868D-04 -3.1135D+02 1.1949D-04 1.2467D-03 3.1261D+02 1.8846D-04
RZ -4.6166D-05 -2.3845D+00
7 X 8.9114D-03 2.4362D+01
Y 5.6433D-04 3.3609D+00 9.6179D-03 9.2511D-04 1.7572D+02 -3.1984D-04
Z -3.5739D-03 -1.7399D+02
RX -1.8351D-05 2.6663D+01
RY 1.0868D-04 -2.7449D+02 1.1949D-04 1.2467D-03 2.7579D+02 8.9854D-04
RZ -4.6166D-05 -2.3845D+00
LOADCASE CONVERGED AFTER 4 ITERATIONS
SECTION 1 COMPLETED
RESTART STAGE 5 COMPLETED
CPU = 2.266 FOR STAGE 5
Examples
Page 4-51
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
RESTART STAGE 6 STARTED
SPLINTER User Manual
LOAD CASE 1 LOAD CASE 2
-------------- --------------
NODE FD SKW DISPLACEMENT REACTION DISPLACEMENT REACTION
---- -- --- ------------ -------- ------------ --------
1 X 8.3574D-03 2.795D+01 7.2685D-03 2.758D+01
Y 5.6433D-04 3.616D-01 1.6533D-03 4.498D-01
Z -3.3536D-03 -1.722D+02 -7.0671D-03 -3.645D+02
RX -1.8351D-05 3.291D+00 -1.0779D-04 -2.062D+01
RY 1.0868D-04 -2.937D+02 1.9235D-05 -3.160D+02
RZ -4.6166D-05 -2.385D+00 -4.6166D-05 -2.385D+00
3 X 8.6344D-03 1.858D+01 7.5455D-03 1.891D+01
Y 2.8734D-04 -1.229D+00 1.3763D-03 -1.561D+00
Z -4.1158D-03 -1.908D+02 -7.8293D-03 -3.558D+02
RX -1.8351D-05 -1.338D+01 -1.0779D-04 -3.987D+01
RY 1.0868D-04 -2.212D+02 1.9235D-05 -2.477D+02
RZ -4.6166D-05 -2.385D+00 -4.6166D-05 -2.385D+00
5 X 8.9114D-03 2.911D+01 7.8225D-03 2.903D+01
Y 1.0338D-05 -2.494D+00 1.0993D-03 -2.130D+00
Z -4.8780D-03 -2.630D+02 -8.5915D-03 -4.553D+02
RX -1.8351D-05 -2.795D+01 -1.0779D-04 -5.028D+01
RY 1.0868D-04 -3.114D+02 1.9235D-05 -3.353D+02
RZ -4.6166D-05 -2.385D+00 -4.6166D-05 -2.385D+00
7 X 8.9114D-03 2.436D+01 7.8225D-03 2.448D+01
Y 5.6433D-04 3.361D+00 1.6533D-03 3.241D+00
Z -3.5739D-03 -1.740D+02 -8.3607D-03 -4.243D+02
RX -1.8351D-05 2.666D+01 -1.0779D-04 1.369D+00
RY 1.0868D-04 -2.745D+02 1.9235D-05 -2.998D+02
RZ -4.6166D-05 -2.385D+00 -4.6166D-05 -2.385D+00
10 X 8.7268D-03 0.000D+00 7.6378D-03 0.000D+00
Y 3.7967D-04 0.000D+00 1.4686D-03 0.000D+00
Z -3.9352D-03 0.000D+00 -8.0064D-03 0.000D+00
RX -1.8351D-05 0.000D+00 -1.0779D-04 0.000D+00
RY 1.0868D-04 0.000D+00 1.9235D-05 0.000D+00
RZ -4.6166D-05 0.000D+00 -4.6166D-05 0.000D+00
11 X 9.8135D-03 0.000D+00 7.8301D-03 0.000D+00
Y 5.6318D-04 0.000D+00 2.5466D-03 0.000D+00
Z -3.9352D-03 0.000D+00 -8.0064D-03 0.000D+00
RX -1.8351D-05 0.000D+00 -1.0779D-04 0.000D+00
RY 1.0868D-04 0.000D+00 1.9235D-05 0.000D+00
RZ -4.6166D-05 0.000D+00 -4.6166D-05 0.000D+00
Examples
Page 4-52
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
GLOBAL PILE DISPLACEMENTS
SPLINTER User Manual
-------------------------
ELEMENT NUMBER 100 PILE CAP NODE 1 LOAD CASE 1 AXIAL 800. LATERAL 100.
--------------------- PILE TIP NODE 2 ---------------
DISTANCE FROM
PILE CAP X Y Z RX RY RZ
------------- ----------- ----------- ----------- ----------- ----------- -----------
0.0000 8.3574D-03 5.6433D-04 -3.3536D-03 -1.8351D-05 1.0868D-04 -4.6166D-05
3.0000 7.7825D-03 5.0641D-04 -3.2745D-03 -1.9609D-05 2.2383D-04 -4.4749D-05
5.0000 7.2321D-03 4.6602D-04 -3.2218D-03 -2.0171D-05 2.7929D-04 -4.3804D-05
7.5000 6.4170D-03 4.1431D-04 -3.1559D-03 -2.0566D-05 3.2493D-04 -4.2623D-05
11.3234 5.0421D-03 3.3454D-04 -3.0554D-03 -2.0569D-05 3.4905D-04 -4.0823D-05
15.5292 3.5558D-03 2.4839D-04 -2.9456D-03 -1.9810D-05 3.2697D-04 -3.8861D-05
20.1555 2.1429D-03 1.5921D-04 -2.8266D-03 -1.7926D-05 2.6875D-04 -3.6736D-05
25.2445 9.6945D-04 7.4709D-05 -2.6981D-03 -1.4337D-05 1.8887D-04 -3.4454D-05
30.8423 1.6765D-04 8.0641D-06 -2.5607D-03 -8.9597D-06 1.0590D-04 -3.2028D-05
37.0000 -2.3725D-04 -2.7433D-05 -2.4149D-03 -3.2623D-06 3.9414D-05 -2.9480D-05
45.3333 -3.1175D-04 -2.9882D-05 -2.2285D-03 1.4428D-06 -7.9151D-06 -2.6282D-05
54.5000 -1.4446D-04 -8.3354D-06 -2.0392D-03 1.5610D-06 -1.7824D-05 -2.3091D-05
62.5802 -3.2391D-05 -4.8696D-06 -1.8862D-03 -3.1867D-07 -9.2920D-06 -2.0554D-05
71.4683 9.0476D-06 -1.0948D-05 -1.7338D-03 -2.7314D-08 -1.7748D-06 -1.8086D-05
81.2453 5.2852D-06 -5.7504D-06 -1.5870D-03 -2.4273D-07 1.6340D-06 -1.5767D-05
92.0000 -1.5222D-05 -1.6326D-05 -1.4523D-03 -2.2940D-07 7.1421D-07 -1.3694D-05
106.9048 -2.2230D-06 -2.1729D-06 -1.3152D-03 8.6555D-07 -9.2490D-07 -1.1623D-05
123.3000 5.2968D-07 1.7569D-07 -1.2294D-03 -1.5834D-07 1.4818D-07 -1.0273D-05
TOTAL GLOBAL SOIL REACTIONS FOR ELEMENT 100 X Y Z
2.7948D+01 3.6160D-01 -1.7220D+02
Figure 4.1 Example, 3, Selected SPLINTER Results
Examples
Page 4-53
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
Page 4-54
SPLINTER User Manual Examples
4.4. Group Pile Structure Interaction
This example consists of a simple four legged structure with a group of four piles connected to each leg. In
addition, two conductor piles are included in the middle of the jacket, as shown in Figure 4.11.
In each corner group there are three piles of 0.50m in diameter and 7.5cm thickness and one pile of 0.75m in
diameter and 10cm in thickness. The two conductor piles are 0.4m in diameter and 3cm thickness.
The soil profile and jacket substructure are as in the example in section 4.2. Pile Structure Interaction and
reference should be made to that example for details of soils data and substructure techniques.
The structure is loaded to simulate a simple wind effect and structure self weight and this is applied to the pile
groups as a component load.
Data units are KN and M.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-55
SPLINTER User Manual Examples
1 3
7 9
101 102 103
105
110
107 108 109
201 202 203
205
210
207 221 208
211 231
201 209
213 223
203
233
205
210
237
227 217
207 219
239 229
209
305
310
321
311 331
301
313 323
303
333
337
327 317
307
319
339 329
309
Figure 4.11 Jacket and Group Pile Model
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-56
SPLINTER User Manual Examples
Notes on data for example 4.
1. The pile geometry is set up using a cylindrical polar system thus simplifying data input requirements.
The ORIG command is used to set up the origin at one of the pile cap nodes in each group, and the DCOS
command rotates the axes system so that local z is along the axes of the piles in the group.
2. The corner pile groups are rigidly connected at the pile cap with one of pile nodes defining the pile cap
location. For the conductor piles, these are assumed to act as structurally independent of each other and
thus are defined as INDP in the PGRP data.
3. Both single point and layered curves and included.
4. The two methods for modelling soil discontinuities are shown on the P-Y data at depths 6.0m and 18.5m
ie if both curves at the discontinuity are single point definitions then they must be separated by a small
distance; if one of the curves defines a soil layer then the depths for the two curves may be the same.
5. The soil data supplied is for a pile of 1.0m in diameter. Since the model is consists of piles with three
different diameters (0.4, 0.5 and 0.75m), a separate soil property must be assigned to each one. The
actual soil data is similar for all three definitions, only the factor commands are changed.
For each of the soil profiles, PFAC and TFAC commands are supplied with the appropriate diameter
value for P-Y and T-Z. The ENDB data requires a second TFAC command defining the area for the
given pile.
6. The elastic soil modulus is defined as a constant for all depths for both lateral and vertical behaviour
(although they are different in the two directions).
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-57
SPLINTER User Manual Examples
SYSTEM DATA AREA 100000
JOB OLD PILE
PROJECT EXM2
FILES STR2
TITLE SPLINTER MANUAL EXAMPLE 4
TEXT *************************************************
TEXT GROUP PILE STRUCTURE INTERACTION ANALYSIS
TEXT 18 PILES ,- FOUR ON EACH CORNER OF JACKET
TEXT + TWO CONDUCTOR PILES
TEXT FOR EACH CORNER PILE GROUP
TEXT 1 PILE 0.75 DIAMETER x 0.1 THICKNESS
TEXT 3 PILES 0.5 DIAMETER x 0.075 THICKNESS
TEXT CONDUCTOR PILES
TEXT 2 PILES 0.40 DIAMETER x 0.030 THICKNESS
TEXT CORN.ER PILE GROUPS RIGIDLV CONNECTED AT CAP
TEXT CONDUCTOR GROUP HAS NO RIGID CONNECTION
TEXT
TEXT 1 LOADCASE
TEXT SIMULATED WIND LOAD PLUS S/W INPUT VIA COMPONENT LOAD
TEXT
TEXT DEFAULT CONVERGENCE
TEXT
TEXT UNITS KN , METRES
TEXT
TEXT *************************************************
STRUCTURE STR2
OPTIONS GOON PRNO NODL CSOL SOIL
UNITS KN METRES
END
COOR
CART
201 -7.5 7.5 -27.42
203 7.5 7.5 -27.42
205 0.0 0.0 -27.42
207 -7.5 -7.5 -27.42
209 7.5 -7.5 -27.42
210 0.0 -1.5 -27.42
305 0.0 0.0 -45.0
310 0.0 -1.5 -45.0
FIN
CYLI GRP1 DEG
DCOS -0.672987 0.672987 0.306882 0.707107 0.707107 0.0
ORIG -7.5 7.5 -27.42
211 1.5 -90.0 0.0
221 1.5 0.0 0.0
231 1.5 90.0 0.0
301 0.0 0.0 25.0
311 1.5 -90.0 25.0
321 1.5 0.0 25.0
331 1.5 90.0 25.0
FIN
CYLI GRP2 DEG
DCOS 0.672987 0.672987 0.306882 0.707107 -0.707107 0.0
ORIG 7.5 7.5 -27.42
213 1.5 -90.0 0.0
223 1.5 0.0 0.0
233 1.5 90.0 0.0
303 0.0 0.0 25.0
313 1.5 -90.0 25.0
323 1.5 0.0 25.0
333 1.5 90.0 25.0
FIN
CYLI GRP3 DEG
DCOS -0.672987 -0.672987 0.306882 -0.707107 0.707107 0.0
ORIG -7.5 -7.5 -27.42
217 1.5 -90.0 0.0
227 1.5 0.0 0.0
237 1.5 90.0 0.0
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-58
SPLINTER User Manual Examples
307 0.0 0.0 25.0
317 1.5 -90.0 25.0
327 1.5 0.0 25.0
337 1.5 90.0 25.0
FIN
CYLI GRP4 DEG
DCOS 0.672987 -0.672987 0.306882 -0.707107 -0.707107 0.0
ORIG 7.5 -7.5 -27.42
219 1.5 -90.0 0.0
229 1.5 0.0 0.0
239 1.5 90.0 0.0
309 0.0 0.0 25.0
319 1.5 -90.0 25.0
329 1.5 0.0 25.0
339 1.5 90.0 25.0
END
PILE
MATP 1
*
* DEFINE A DIFFERENT PILE GROUP NUMBER FOR EACH
* COLLECTION OF PILES
*
GROUP 100
SOLP 10
TUBE 201 301 10 101
*
* ONE PILE IN EACH MAIN GROUP HAS A DIFFERENT DIAMTETER SO
* PROVIDE ANOTHER SOIL INTEGER AND MODIFY FACTORS ACCORDINGLY
*
SOLP 11
TUBE 211 311 11 102
TUBE 221 321 11 103
TUBE 231 331 11 104
GROUP 200
SOLP 10
TUBE 203 303 10 201
SOLP 11
TUBE 213 313 11 202
TUBE 223 323 11 203
TUBE 233 333 11 204
GROUP 300
SOLP 10
TUBE 207 307 10 301
SOLP 11
TUBE 217 317 11 302
TUBE 227 327 11 303
TUBE 237 337 11 304
GROUP 400
SOLP 10
TUBE 209 309 10 401
SOLP 11
TUBE 219 319 11 402
TUBE 229 329 11 403
TUBE 239 339 11 404
*
* CONDUCTOR PILES
*
GROUP 500
SOLP 20
TUBE 205 305 20 501
TUBE 210 310 20 502
END
TOPO
TOWR ASSM 201 203 207 209 205 210
END
PGRP
100 CONN 201 MAXD 10.0
200 CONN 203 MAXD 10.0
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-59
SPLINTER User Manual Examples
300 CONN 207 MAXD 10.0
400 CONN 209 MAXD 10.0
500 INDP DEFT
END
SOIL
*
* SET GLOBAL MUDLINE TO COINCIDE WITH STRUCTURAL DEFINITION
*
MUDD -27.42
PFAC 0.75
TFAC 0.75
10 MAPY 45000.0 0.45
10 P-Y 0.0 4.0
P 0.0 130.0 170.0 190.0 210.0 210.0
Y 0.0 0.0045 0.012 0.2 0.35 1.0
P-Y 4.0
P 0.0 105.0 175.0 71.0 71.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 6.0
P 0.0 125.0 200.0 185.0 185.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 6.01
P 0.0 330.0 600.0 180.0 180.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 10.0 18.5
P 0.0 720.0 1220.0 750.0 750.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 18.5
P 0.0 1320.0 2400.0 2400.0
Y 0.0 0.014 0.06 1.0
P-Y 50.0
P 0.0 2075.0 3500.0 3500.0
Y 0.0 0.014 0.06 1.0
10 MATZ 100000.0 0.45
10 T-Z 0.0
T 0.0 0.0
Z 0.0 1.0
T-Z 8.0
T 0.0 170.0 170.0
Z 0.0 0.012 1.0
T-Z 18.5
T 0.0 285.0 285.0
Z 0.0 0.012 1.0
T-Z 18.501
T 0.0 285.0 285.0
Z 0.0 0.012 1.0
T-Z 26.0 50.0
T 0.0 320.0 320.0
Z 0.0 0.012 1.0
10 ENDB
TFAC 0.5625
T 0.0 0.0 9000.0 9000.0
Z -1.0 0.0 0.085 1.0
PFAC 0.50
TFAC 0.50
11 MAPY 45000.0 0.45
11 P-Y 0.0 4.0
P 0.0 130.0 170.0 190.0 210.0 210.0
Y 0.0 0.0045 0.012 0.2 0.35 1.0
P-Y 4.0
P 0.0 105.0 175.0 71.0 71.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 6.0
P 0.0 125.0 200.0 185.0 185.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 6.01
P 0.0 330.0 600.0 180.0 180.0
Y 0.0 0.014 0.06 1.0 10.0
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-60
SPLINTER User Manual Examples
P-Y 10.0 18.5
P 0.0 720.0 1220.0 750.0 750.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 18.5
P 0.0 1320.0 2400.0 2400.0
Y 0.0 0.014 0.06 1.0
P-Y 50.0
P 0.0 2075.0 3500.0 3500.0
Y 0.0 0.014 0.06 1.0
11 MATZ 100000.0 0.45
11 T-Z 0.0
T 0.0 0.0 1.0E-6
Z 0.0 1.0 10.0
T-Z 8.0
T 0.0 170.0 170.0
Z 0.0 0.012 1.0
T-Z 18.5
T 0.0 285.0 285.0
Z 0.0 0.012 1.0
T-Z 18.501
T 0.0 285.0 285.0
Z 0.0 0.012 1.0
T-Z 26.0 50.0
T 0.0 320.0 320.0
Z 0.0 0.012 1.0
11 ENDB
TFAC 0.25
T 0.0 0.0 9000.0 9000.0
Z -1.0 0.0 0.085 1.0
PFAC 0.4
TFAC 0.4
20 MAPY 45000.0 0.45
20 P-Y 0.0 4.0
P 0.0 130.0 170.0 190.0 210.0 210.0
Y 0.0 0.0045 0.012 0.2 0.35 1.0
P-Y 4.0
P 0.0 105.0 175.0 71.0 71.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 6.0
P 0.0 125.0 200.0 185.0 185.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 6.01
P 0.0 330.0 600.0 180.0 180.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 10.0 18.5
P 0.0 720.0 1220.0 750.0 750.0
Y 0.0 0.014 0.06 1.0 10.0
P-Y 18.5
P 0.0 1320.0 2400.0 2400.0
Y 0.0 0.014 0.06 1.0
P-Y 50.0
P 0.0 2075.0 3500.0 3500.0
Y 0.0 0.014 0.06 1.0
20 MATZ 100000.0 0.45
20 T-Z 0.0
T 0.0 0.0
Z 0.0 1.0
T-Z 8.0
T 0.0 170.0 170.0
Z 0.0 0.012 1.0
T-Z 18.5
T 0.0 285.0 285.0
Z 0.0 0.012 1.0
T-Z 18.501
T 0.0 285.0 285.0
Z 0.0 0.012 1.0
T-Z 26.0 50.0
T 0.0 320.0 320.0
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-61
SPLINTER User Manual Examples
Z 0.0 0.012 1.0
20 ENDB
TFAC 0.16
T 0.0 0.0 9000.0 9000.0
Z -1.0 0.0 0.085 1.0
END
MATE
1 2.00E08 0.3 0 7.850
END
GEOM
10 TUBE 0.75 0.1
11 TUBE 0.50 0.075
20 TUBE 0.40 0.03
END
LOAD 1
CASE 1 WIND LOAD PLUS STRUCTURE SELF WEIGHT
COMP LOAD
ASSM 1 4.0
ASSM 2 1.0
END
STOP
Figure 4.2 Example 4, Group Pile SPLINTER Data for Pile-Structure Interaction
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-62
SPLINTER User Manual Examples
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page 4-63
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates 1SPLINTER 13.01.00.0 (QA) 13:49 02-05-2001 PAGE 1
SPLINTER User Manual
*************************************************
GROUP PILE STRUCTURE INTERACTION ANALYSIS
18 PILES ,- FOUR ON EACH CORNER OF JACKET
+ TWO CONDUCTOR PILES
FOR EACH CORNER PILE GROUP
1 PILE 0.75 DIAMETER x 0.1 THICKNESS
3 PILES 0.5 DIAMETER x 0.075 THICKNESS
CONDUCTOR PILES
2 PILES 0.40 DIAMETER x 0.030 THICKNESS
CORN.ER PILE GROUPS RIGIDLV CONNECTED AT CAP
CONDUCTOR GROUP HAS NO RIGID CONNECTION
1 LOADCASE
SIMULATED WIND LOAD PLUS S/W INPUT VIA COMPONENT LOAD
DEFAULT CONVERGENCE
UNITS KN , METRES
*************************************************
STRUCTURE STR2
A S A S EXECUTION CONTROL OPTIONS
------------------------------------
USER OPTIONS GOON PRNO NODL CSOL SOIL
RUN PARAMETERS
--------------
PROJECT NAME EXM2
PROJECT STATUS OLD
JOB TYPE PILE
STRUCTURE NAME STR2
FILE NAME STR2
SPLINTER PROGRAM PARAMETERS
---------------------------
MAXIMUM NUMBER OF ITERATIONS 10 (DEFAULT)
RELATIVE CONVERGENCE VALUE USED 5.000D-02 (DEFAULT)
BASIC PILE SUBDIVISION CRITERIA 1.000 PILE DIAMETERS (DEFAULT)
SUBDIVISION MODIFIER 0.100 (DEFAULT)
PILES ARE SUBDIVIDED ON THE FOLLOWING BASIS
(1) AT POINTS OF APPLICATION OF EXTERNAL LOADS
Examples
Page 4-64
(2) AT SOIL LAYER DIVISIONS
(3) AT CHANGES IN PILE SECTION PROPERTIES
IN ADDITION,NO SUBDIVISION WILL BE LONGER THAN
THE BASIC SUBDIVISION PLUS A PERCENTAGE OF THE
DEPTH GIVEN BY THE SUBDIVISION MODIFIER
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates RESULTANT FORCES IN GLOBAL DIRECTIONS
-------------------------------------
SPLINTER User Manual
ABOUT ORIGIN X = 0.000D+00 Y = 0.000D+00 Z = 0.000D+00
LOAD CASE 1
FREEDOM FORCE MOMENT
------- --------- ---------
X 8.000D+03 4.323D+02
Y -7.105D-15 3.032D+04
Z -2.199D+03 -3.000D+04
PILE CAP DISPLACEMENTS AND REACTIONS ITERATION REPORT
LOAD CASE NO. 1 ITERATION 1
------------------ -------------
RESULTANT PERCENTAGE RESULTANT PERCENTAGE
NODE FD DISPLACEMENT REACTION DISPLACEMENT CHANGE REACTION CHANGE
---- -- ------------ ----------- ------------ ---------- ----------- ----------
210 X 1.1648D-03 0.0000D+00
Y -8.6030D-05 0.0000D+00 1.2986D-03 0.0000D+00
Z -5.6756D-04 0.0000D+00
RX 1.8338D-04 0.0000D+00
RY 1.1595D-03 0.0000D+00 1.4445D-03 0.0000D+00
RZ -8.4168D-04 0.0000D+00
211 X 3.4681D-03 6.0576D+02
Y 3.6049D-03 -3.9253D+02 1.4423D-02 2.5743D+03
Z 1.3528D-02 2.4710D+03
RX -1.8633D-03 1.8271D+01
RY -2.2023D-04 -1.0443D+02 1.8768D-03 1.1418D+02
RZ -4.3997D-05 -4.2404D+01
213 X 5.6305D-03 6.1382D+02
Y -3.8497D-03 3.2322D+02 1.2535D-02 2.0888D+03
Z -1.0517D-02 -1.9703D+03
RX 2.1681D-03 9.2630D+01
RY -8.2968D-05 -2.7469D+02 2.1703D-03 2.9526D+02
RZ 5.2293D-05 -5.6092D+01
217 X -1.3249D-03 2.3510D+02
Y 3.0213D-03 4.0614D+02 8.0459D-03 1.4750D+03
Z 7.3385D-03 1.3984D+03
RX 2.4873D-04 1.7471D+02
RY -7.6303D-04 3.0906D+01 8.1757D-04 1.8614D+02
RZ -1.5600D-04 -5.6299D+01
219 X -5.6685D-04 3.0403D+02
Examples
Page 4-65
Y -3.3155D-03 -4.5692D+02 8.3424D-03 1.5768D+03
Z -7.6343D-03 -1.4782D+03
RX -5.0844D-04 -2.6223D+02
RY -1.0109D-03 -7.9717D+01 1.1562D-03 2.7930D+02
RZ -2.3729D-04 -5.3740D+01
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
PILE CAP DISPLACEMENTS AND REACTIONS ITERATION REPORT
SPLINTER User Manual
LOAD CASE NO. 1 ITERATION 6
------------------ -------------
RESULTANT PERCENTAGE RESULTANT PERCENTAGE
NODE FD DISPLACEMENT REACTION DISPLACEMENT CHANGE REACTION CHANGE
---- -- ------------ ----------- ------------ ---------- ----------- ----------
210 X 1.5057D-03 0.0000D+00
Y -9.2122D-05 0.0000D+00 1.5978D-03 9.0767D-02 0.0000D+00 0.0000D+00
Z -5.2651D-04 0.0000D+00
RX 1.6840D-04 0.0000D+00
RY 1.3825D-03 0.0000D+00 1.6526D-03 7.9328D-02 0.0000D+00 0.0000D+00
RZ -8.8965D-04 0.0000D+00
211 X 6.4447D-03 5.9195D+02
Y 4.8001D-03 -3.6482D+02 2.0698D-02 5.2368D-01 2.4662D+03 -8.6472D-01
Z 1.9075D-02 2.3661D+03
RX -2.2171D-03 4.1557D+01
RY 7.5960D-05 -9.1553D+01 2.2186D-03 1.1137D+00 1.1110D+02 -2.7690D+00
RZ 3.2254D-05 -4.7257D+01
213 X 8.5851D-03 5.6947D+02
Y -5.2760D-03 3.0171D+02 1.6868D-02 1.5961D-01 1.9513D+03 -3.7607D-02
Z -1.3528D-02 -1.8418D+03
RX 2.4217D-03 7.8334D+01
RY 1.9773D-04 -2.4595D+02 2.4304D-03 7.1175D-01 2.6432D+02 3.3185D-02
RZ 5.5441D-05 -5.6891D+01
217 X -1.3071D-03 2.4958D+02
Y 4.3526D-03 4.0755D+02 1.1509D-02 1.4349D-01 1.5466D+03 1.5106D-01
Z 1.0574D-02 1.4710D+03
RX 3.1022D-04 1.6815D+02
RY -8.0897D-04 4.6350D+01 8.9202D-04 -5.9170D-02 1.8450D+02 5.7987D-01
RZ -2.1218D-04 -6.0138D+01
219 X -4.0345D-04 3.2499D+02
Y -4.8646D-03 -4.5317D+02 1.1305D-02 8.9826D-02 1.6341D+03 7.0436D-02
Z -1.0196D-02 -1.5360D+03
RX -5.1760D-04 -2.4817D+02
RY -1.0070D-03 -7.3948D+01 1.1667D-03 -6.6790D-02 2.6438D+02 3.3137D-01
RZ -2.8148D-04 -5.3270D+01
RESTART STAGE 5 COMPLETED
CPU = 4.609 FOR STAGE 5
Examples
Page 4-66
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates RESTART STAGE 6 STARTED
SPLINTER User Manual
LOAD CASE 1
--------------
NODE FD SKW DISPLACEMENT REACTION
---- -- --- ------------ --------
201 X 6.4104D-03 0.000D+00
Y 4.8343D-03 0.000D+00
Z 1.6643D-02 0.000D+00
RX -2.2171D-03 0.000D+00
RY 7.5960D-05 0.000D+00
RZ 3.2254D-05 0.000D+00
203 X 8.6439D-03 0.000D+00
Y -5.2172D-03 0.000D+00
Z -1.6306D-02 0.000D+00
RX 2.4217D-03 0.000D+00
RY 1.9773D-04 0.000D+00
RZ 5.5441D-05 0.000D+00
205 X 2.8499D-03 0.000D+00
Y -9.1434D-05 0.000D+00
Z -4.8172D-04 0.000D+00
RX -4.1426D-05 0.000D+00
RY 1.7675D-03 0.000D+00
RZ -1.0397D-03 0.000D+00
207 X -1.0820D-03 0.000D+00
Y 4.5776D-03 0.000D+00
Z 1.0045D-02 0.000D+00
RX 3.1022D-04 0.000D+00
RY -8.0897D-04 0.000D+00
RZ -2.1218D-04 0.000D+00
209 X -7.0200D-04 0.000D+00
Y -4.5661D-03 0.000D+00
Z -1.0715D-02 0.000D+00
RX -5.1760D-04 0.000D+00
RY -1.0070D-03 0.000D+00
RZ -2.8148D-04 0.000D+00
210 X 1.5057D-03 0.000D+00
Y -9.2122D-05 0.000D+00
Z -5.2651D-04 0.000D+00
RX 1.6840D-04 0.000D+00
RY 1.3825D-03 0.000D+00
RZ -8.8965D-04 0.000D+00
211 X 6.4447D-03 5.920D+02
Y 4.8001D-03 -3.648D+02
Examples
Page 4-67
LOAD CASE 1
--------------
NODE FD SKW DISPLACEMENT REACTION
---- -- --- ------------ --------
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates Z 1.9075D-02 2.366D+03
RX -2.2171D-03 4.156D+01
SPLINTER User Manual
RY 7.5960D-05 -9.155D+01
RZ 3.2254D-05 -4.726D+01
213 X 8.5851D-03 5.695D+02
Y -5.2760D-03 3.017D+02
Z -1.3528D-02 -1.842D+03
RX 2.4217D-03 7.833D+01
RY 1.9773D-04 -2.460D+02
RZ 5.5441D-05 -5.689D+01
217 X -1.3071D-03 2.496D+02
Y 4.3526D-03 4.076D+02
Z 1.0574D-02 1.471D+03
RX 3.1022D-04 1.681D+02
RY -8.0897D-04 4.635D+01
RZ -2.1218D-04 -6.014D+01
219 X -4.0345D-04 3.250D+02
Y -4.8646D-03 -4.532D+02
Z -1.0196D-02 -1.536D+03
RX -5.1760D-04 -2.482D+02
RY -1.0070D-03 -7.395D+01
RZ -2.8148D-04 -5.327D+01
221 X 6.4128D-03 4.803D+02
Y 5.8223D-03 -2.523D+02
Z 1.4481D-02 1.674D+03
RX -2.2171D-03 2.339D+01
RY 7.5960D-05 -1.765D+02
RZ 3.2254D-05 -6.172D+01
223 X 8.6789D-03 5.541D+02
Y -6.2760D-03 2.849D+02
Z -1.4061D-02 -1.796D+03
RX 2.4217D-03 3.057D-01
RY 1.9773D-04 -2.649D+02
RZ 5.5441D-05 -7.818D+01
227 X -1.6686D-03 1.885D+02
Y 4.6490D-03 3.489D+02
Z 8.9149D-03 1.107D+03
RX 3.1022D-04 2.199D+02
RY -8.0897D-04 4.054D+01
Examples
Page 4-68
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates GLOBAL PILE DISPLACEMENTS
-------------------------
SPLINTER User Manual
ELEMENT NUMBER 101 PILE CAP NODE 201 LOAD CASE 1 WIND LOAD PLUS STRUCTURE SELF WEIGHT
--------------------- PILE TIP NODE 301 ---------------
DISTANCE FROM
PILE CAP X Y Z RX RY RZ
------------- ----------- ----------- ----------- ----------- ----------- -----------
0.0000 6.4104D-03 4.8343D-03 1.6643D-02 -2.2171D-03 7.5960D-05 3.2254D-05
0.9056 6.2502D-03 3.0032D-03 1.6180D-02 -2.0023D-03 1.9295D-04 3.7956D-05
1.9017 5.9880D-03 1.2392D-03 1.5747D-02 -1.7197D-03 2.6943D-04 2.1445D-05
2.9975 5.6522D-03 -3.6497D-04 1.5360D-02 -1.3944D-03 3.0630D-04 -1.1496D-05
4.2028 5.2762D-03 -1.7292D-03 1.5029D-02 -1.0582D-03 3.0951D-04 -5.2580D-05
5.2035 4.9820D-03 -2.5751D-03 1.4817D-02 -8.1253D-04 2.9353D-04 -8.4533D-05
6.3042 4.6917D-03 -3.2486D-03 1.4637D-02 -5.8348D-04 2.6262D-04 -1.1485D-04
8.4056 4.2687D-03 -3.9568D-03 1.4404D-02 -2.7046D-04 1.8485D-04 -1.5380D-04
10.5070 4.0226D-03 -4.1860D-03 1.4254D-02 -1.0096D-04 1.0971D-04 -1.6640D-04
12.4313 3.9159D-03 -4.1945D-03 1.4150D-02 -2.9959D-05 6.0417D-05 -1.6013D-04
14.5481 3.8761D-03 -4.1188D-03 1.4054D-02 9.4277D-07 3.1205D-05 -1.4282D-04
16.8766 3.8629D-03 -4.0115D-03 1.3968D-02 1.2729D-05 2.6394D-05 -1.1919D-04
19.4379 3.8227D-03 -3.8903D-03 1.3909D-02 2.2998D-05 4.2526D-05 -9.4986D-05
22.0865 3.7227D-03 -3.7542D-03 1.3899D-02 3.5872D-05 6.3369D-05 -7.6664D-05
25.0000 3.5670D-03 -3.5901D-03 1.3947D-02 4.3773D-05 7.2281D-05 -6.5624D-05
TOTAL GLOBAL SOIL REACTIONS FOR ELEMENT 101 X Y Z
9.2285D+02 -5.5206D+02 3.3643D+03
Examples
Page 4-69
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates GLOBAL PILE DISPLACEMENTS
-------------------------
SPLINTER User Manual
ELEMENT NUMBER 201 PILE CAP NODE 203 LOAD CASE 1 WIND LOAD PLUS STRUCTURE SELF WEIGHT
--------------------- PILE TIP NODE 303 ---------------
DISTANCE FROM
PILE CAP X Y Z RX RY RZ
------------- ----------- ----------- ----------- ----------- ----------- -----------
0.0000 8.6439D-03 -5.2172D-03 -1.6306D-02 2.4217D-03 1.9773D-04 5.5441D-05
0.9056 8.3201D-03 -3.2297D-03 -1.5831D-02 2.1594D-03 3.9686D-04 7.1932D-05
1.9017 7.8164D-03 -1.3352D-03 -1.5409D-02 1.8324D-03 5.2369D-04 5.9964D-05
2.9975 7.1823D-03 3.6843D-04 -1.5050D-02 1.4667D-03 5.7998D-04 2.5666D-05
4.2028 6.4764D-03 1.7979D-03 -1.4761D-02 1.0957D-03 5.7677D-04 -2.1154D-05
5.2035 5.9242D-03 2.6701D-03 -1.4587D-02 8.2838D-04 5.4207D-04 -5.9418D-05
6.3042 5.3777D-03 3.3508D-03 -1.4447D-02 5.8242D-04 4.8132D-04 -9.7377D-05
8.4056 4.5728D-03 4.0334D-03 -1.4275D-02 2.5392D-04 3.3460D-04 -1.5034D-04
10.5070 4.0916D-03 4.2188D-03 -1.4156D-02 8.4737D-05 1.9359D-04 -1.7337D-04
12.4313 3.8766D-03 4.1929D-03 -1.4055D-02 2.1232D-05 9.7534D-05 -1.7254D-04
14.5481 3.8018D-03 4.0972D-03 -1.3939D-02 1.0693D-06 3.3498D-05 -1.5748D-04
16.8766 3.8111D-03 3.9921D-03 -1.3813D-02 -5.5389D-07 8.6425D-06 -1.3323D-04
19.4379 3.8250D-03 3.8953D-03 -1.3696D-02 -3.0690D-06 1.7620D-05 -1.0651D-04
22.0865 3.7848D-03 3.8019D-03 -1.3620D-02 -1.1596D-05 4.0209D-05 -8.5071D-05
25.0000 3.6814D-03 3.6924D-03 -1.3593D-02 -1.8489D-05 5.2086D-05 -7.1997D-05
TOTAL GLOBAL SOIL REACTIONS FOR ELEMENT 201 X Y Z
1.1648D+03 6.9846D+02 -3.8981D+03
Examples
Page 4-70
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates TREE OF COMPONENTS IN STRUCTURE STR2
------------------------------------
SPLINTER User Manual
2 STR2 --- 1 ASSM
(TOWR)
KEY -
COMPONENTS ARE SHOWN TOGETHER WITH THEIR (UNIQUE) NUMBER AND MASTER COMPONENT TYPE THUS
--- 10 COMP
(MCM1)
INDICATES COMPONENT NAME COMP
(UNIQUE) NUMBER 10
MASTER COMPONENT TYPE MCM1
RESTART STAGE 6 COMPLETED
CPU = 0.078 FOR STAGE 6
RESTART STAGE 8 STARTED
PILE FORCE AND STRESS REPORT
ELEMENT NUMBER 101 PILE CAP NODE 201 LOAD CASE 1 WIND LOAD PLUS STRUCTURE SELF
WEIGHT
--------------------- PILE TIP NODE 301 ---------------
DISTANCE FROM AXIAL BENDING COMBINED
PILE CAP FORCE XX SHEAR QY SHEAR QZ TORQUE XX MOMENT YY MOMENT ZZ STRESS STRESS STRESS
---------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- -----------
0.000D+00 3.5220D+03 3.9838D+01 2.6219D+02 -5.0046D+01 5.8221D+01 5.6647D+02 1.7247D+04 1.9343D+04 3.6591D+04
9.056D-01 3.5157D+03 -6.2022D+00 1.7745D+02 -4.9813D+01 2.5407D+02 5.7742D+02 1.7217D+04 2.1429D+04 3.8645D+04
1.902D+00 3.4943D+03 -4.2867D+01 9.3175D+01 -4.9064D+01 3.8335D+02 5.4817D+02 1.7112D+04 2.2722D+04 3.9834D+04
2.997D+00 3.4534D+03 -6.5640D+01 2.2204D+01 -4.7726D+01 4.3965D+02 4.8390D+02 1.6912D+04 2.2208D+04 3.9120D+04
4.203D+00 3.3872D+03 -7.4157D+01 -3.0572D+01 -4.5737D+01 4.2773D+02 3.9552D+02 1.6587D+04 1.9789D+04 3.6376D+04
5.203D+00 3.3155D+03 -7.3645D+01 -3.8187D+01 -4.3755D+01 3.9254D+02 3.2113D+02 1.6236D+04 1.7227D+04 3.3464D+04
6.304D+00 3.2190D+03 -7.1466D+01 -4.3549D+01 -4.1304D+01 3.4662D+02 2.4096D+02 1.5764D+04 1.4340D+04 3.0103D+04
8.406D+00 2.9830D+03 -5.1439D+01 -5.3437D+01 -3.6070D+01 2.3116D+02 1.0858D+02 1.4608D+04 8.6752D+03 2.3283D+04
1.051D+01 2.6986D+03 -2.5631D+01 -4.2540D+01 -3.0741D+01 1.2294D+02 3.1638D+01 1.3215D+04 4.3120D+03 1.7527D+04
1.243D+01 2.4160D+03 -8.6894D+00 -2.7355D+01 -2.6180D+01 5.8432D+01 3.5922D+00 1.1831D+04 1.9886D+03 1.3820D+04
1.455D+01 2.0831D+03 1.2018D+00 -1.5345D+01 -2.1548D+01 1.4882D+01 -1.0995D+00 1.0201D+04 5.0690D+02 1.0708D+04
1.688D+01 1.6871D+03 4.6956D+00 -5.8977D+00 -1.6918D+01 -7.4571D+00 1.0454D+01 8.2618D+03 4.3618D+02 8.6980D+03
Examples
Page 4-71
1.944D+01 1.2061D+03 2.4184D+00 -4.3323D-01 -1.2337D+01 -1.2149D+01 2.1731D+01 5.9065D+03 8.4568D+02 6.7522D+03
2.209D+01 6.5568D+02 -3.6427D+00 2.1921D+00 -8.1606D+00 -6.1666D+00 1.8020D+01 3.2109D+03 6.4695D+02 3.8579D+03
2.500D+01 -1.6257D-11 4.8122D-12 7.9581D-13 -5.3291D-15 -2.8400D-13 1.7031D-13 -7.9613D-11 1.1248D-11 -9.0861D-11
AXIAL PILE CAPACITY SAFETY FACTOR 1.0388D+00 (TENSION)
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
PILE FORCE AND STRESS REPORT
SPLINTER User Manual
ELEMENT NUMBER 201 PILE CAP NODE 203 LOAD CASE 1 WIND LOAD PLUS STRUCTURE SELF
WEIGHT
--------------------- PILE TIP NODE 303 ---------------
DISTANCE FROM AXIAL BENDING COMBINED
PILE CAP FORCE XX SHEAR QY SHEAR QZ TORQUE XX MOMENT YY MOMENT ZZ STRESS STRESS STRESS
---------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- -----------
0.000D+00 -4.1143D+03 5.7689D+01 3.2973D+02 -5.5273D+01 -3.4585D+01 -8.3050D+02 -2.0148D+04 2.8235D+04 -4.8383D+04
9.056D-01 -4.1080D+03 8.6333D+01 2.3463D+02 -5.5016D+01 2.1751D+02 -7.6083D+02 -2.0117D+04 2.6879D+04 -4.6997D+04
1.902D+00 -4.0867D+03 1.0406D+02 1.3442D+02 -5.4189D+01 3.9594D+02 -6.6175D+02 -2.0013D+04 2.6195D+04 -4.6208D+04
2.997D+00 -4.0458D+03 1.0874D+02 4.4426D+01 -5.2711D+01 4.8566D+02 -5.4080D+02 -1.9813D+04 2.4690D+04 -4.4503D+04
4.203D+00 -3.9798D+03 9.9576D+01 -2.4277D+01 -5.0515D+01 4.8955D+02 -4.1191D+02 -1.9489D+04 2.1733D+04 -4.1222D+04
5.203D+00 -3.9082D+03 9.5669D+01 -3.4587D+01 -4.8326D+01 4.5915D+02 -3.1391D+02 -1.9139D+04 1.8893D+04 -3.8032D+04
6.304D+00 -3.8118D+03 9.0211D+01 -4.2272D+01 -4.5618D+01 4.1569D+02 -2.1152D+02 -1.8667D+04 1.5843D+04 -3.4510D+04
8.406D+00 -3.5763D+03 5.6589D+01 -6.0053D+01 -3.9837D+01 2.9053D+02 -5.8572D+01 -1.7513D+04 1.0067D+04 -2.7581D+04
1.051D+01 -3.2914D+03 2.2999D+01 -5.1206D+01 -3.3952D+01 1.6300D+02 1.6698D+01 -1.6118D+04 5.5658D+03 -2.1684D+04
1.243D+01 -3.0078D+03 3.5945D+00 -3.4665D+01 -2.8914D+01 8.2832D+01 3.6122D+01 -1.4730D+04 3.0696D+03 -1.7799D+04
1.455D+01 -2.6745D+03 -7.1875D+00 -2.0630D+01 -2.3798D+01 2.5738D+01 2.8597D+01 -1.3097D+04 1.3069D+03 -1.4404D+04
1.688D+01 -2.2849D+03 -9.4136D+00 -8.9232D+00 -1.8685D+01 -6.0569D+00 2.5573D+00 -1.1189D+04 2.2333D+02 -1.1413D+04
1.944D+01 -1.8227D+03 -5.3719D+00 -1.8770D+00 -1.3626D+01 -1.5581D+01 -1.6568D+01 -8.9261D+03 7.7256D+02 -9.6987D+03
2.209D+01 -1.3037D+03 2.5234D+00 2.6816D+00 -9.0130D+00 -1.1165D+01 -2.0116D+01 -6.3844D+03 7.8148D+02 -7.1659D+03
2.500D+01 2.2396D-11 2.7480D-12 -4.2881D-12 -1.9540D-14 -8.5265D-14 -2.1294D-13 1.0968D-10 7.7915D-12 1.1747D-10
AXIAL PILE CAPACITY SAFETY FACTOR 2.1197D+00 (COMPRESSION)
Figure 4.1 Example 4, Selected SPLINTER Results
Examples
Page 4-72
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
Page 4-73
SPLINTER User Manual Appendix A
A - Preliminary Data Block for SPLINTER
A.1 Introduction
The preliminary data is the first block of the SPLINTER data. It defines:
• job type
• memory size to be used
• identity of the project
• structure to be processed within that project
• options which will affect the course of the run
• amount of printing produced
• files to be saved for subsequent processing
The preliminary data must contain a JOB command and terminate with END. Other commands when used, may
be in any order, however the user is recommended to follow the order given below.
Different commands are required for the different analysis types. See Table A.1 .
The following commands are available within the Preliminary data
SYSTEM - memory requirement
PROJECT - name of project
JOB - type of analysis
FILES - name of backing files
TITLE - title for this run
TEXT - descriptive text
STRUCTURE - name of structure
COMPONENT - name of component
MAXIT - maximum number of iterations per loadcase
CONVERGE - defines convergence criteria
DIVISION - defines criteria employed in pile subdivision process
OPTIONS - control options
RESTART - select restart stages
GOTP - origin for load resultants
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-1
SPLINTER User Manual Appendix A
SAVE - save plot file
RESU - save results to universal database
UNITS - defines the units utilised in the analysis
LIBRARY - section library file name
END - terminate preliminary data
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-2
SPLINTER User Manual Appendix A
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-3
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
SPLINTER User Manual
Command
JOB TYPE
Analysis
IDENTIFIERS
COMPONENT
STRUCTURE
CONVERGE
DIVISION
RESTART
LIBRARY
PROJECT
OPTIONS
SYSTEM
MAXIT
UNITS
TITLE
FILES
GOTP
SAVE
RESU
TEXT
END
JOB
Non-substructured C R X X C R PILE
ie single and group pile analysis
Substructured R C R R C X C R PILE
ie pile-soil-structure interaction
Stiffness input R C R R X C X X X C X C X STIF
master component creation
Key
C compulsory
R recommended
Appendix A
Page A-4
X invalid
Table A.1 Preliminary Data Command Requirements
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates
Page A-5
SPLINTER User Manual Appendix A
A.2 SYSTEM Command
To define the amount of memory used for data by this run. Optional.
SYSTEM DATA AREA memory
Parameters
SYSTEM : keyword
DATA AREA : keyword
memory : amount of memory (in 4 byte words) to be used by this run. Typical values are between 30000
and 1000000. If the SYSTEM command is omitted a default value 1000000 is used. (Integer)
Example
SYSTEM DATA AREA 80000
A.3 PROJECT Command
To define the project name for the current run. Optional, if omitted project name defaults to ASAS.
PROJECT pname
Parameters
PROJECT : keyword
pname : project name for current run. (Alphanumeric, 4 characters, first character must be alphabetic)
Notes
1. All runs with the same project name access the same data base. A project data base consists of one
project file (with a file name consisting of the 4 characters of pname with the number 10 appended)
which acts as an index to other files created under this project, together with those other files.
Example
PROJECT HIJK
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-6
SPLINTER User Manual Appendix A
A.4 JOB Command
To define the type of analysis being performed and whether to create a new project database or to update an
existing one.
JOB (status) jobtype
Parameters
JOB : keyword
status : NEW, this is the first run in a new project database
OLD, for all subsequent runs associated with the same project name. Optional, if omitted
OLD is assumed.
jobtype : define the type of analysis to be performed in this run
PILE - pile analyses
STIF - stiffness input component creation analysis
Example
To define a new project data base - a single pile analysis.
PROJECT FRED
JOB NEW PILE
To add a pile-structure interaction analysis to an existing project FRED (status has been allowed to default to
OLD.)
JOB PILE FRED
A.5 FILES Command
To define the prefix name for the backing files created in this run. Optional, if omitted file name defaults to
project name.
FILES fname
Parameters
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-7
SPLINTER User Manual Appendix A
FILES : keyword
fname : prefix name for any backing files created by this run. (Alphanumeric, 4 characters, first
character must be alphabetic).
Notes
fname is used as a prefix for all files created during the current run. The four characters are appended with two
digits in the range 12 to 35 to create each individual file. This name will also be used by default for the plotfile
name, see Section A.16.
Example
FILES BILL
A.6 TITLE Command
To define a title for this run. Recommended
TITLE title
Parameters
TITLE : keyword
title : this line of text will be printed out at the top of each page of SPLINTER output.
(Alphanumeric, up to 74 characters).
Example
TITLE THIS IS AN EXAMPLE OF A TITLE LINE
A.7 TEXT Command
To define a line of text to be printed once only at the beginning of the output. Several TEXT lines may be
defined to give a fuller description of the current analysis on the printed output. Optional.
TEXT text
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-8
SPLINTER User Manual Appendix A
Parameters
TEXT : keyword
text : this line of text will be printed once, at the beginning of the output. (Alphanumeric, up to 75
characters)
Example
TEXT THIS EXAMPLE OF THE TEXT
TEXT Command IS SPREAD
TEXT OVER THREE LINES.
A.8 STRUCTURE Command
To define the structure name for the current run. Valid only and compulsory for soil-pile-interaction analysis.
See Table A.1 .
STRUCTURE sname
Parameters
STRUCTURE : keyword
sname : structure name. The name must be unique from all other structure or master component names
in this project. (Alphanumeric, 4 characters, the first character must be alphabetic)
Note
For a single pile analysis, the structure name is taken from fname on FILES command.
Example
STRUCTURE SHIP
A.9 COMPONENT Command
To define the master component name for a component creation run. Valid only and compulsory for JOB type
STIF. See Table A.1 .
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-9
SPLINTER User Manual Appendix A
COMPONENT cname
Parameters
COMPONENT : keyword
cname : component name for the master component being created by this run. The name must be
unique from all other structure and master component names in this project.
(Alphanumeric, 4 characters, the first character must be alphabetic).
Example
COMPONENT LEFT
Note
The name must not be an element name (e.g. BR20, BEAM) or the words DCOS, MIRR or ORIG.
A.10 MAXIT Command
To define the maximum number of iterations to be carried out for each loadcase. If this number is reached,
processing is finished for this loadcase and displacements and forces will be printed out for the last iteration.
Optional, if omitted the default value is 10 iterations.
MAXIT numit
Parameters
MAXIT : keyword
numit : maximum number of iterations per loadcase. (Integer)
Examples
MAXIT 8
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-10
SPLINTER User Manual Appendix A
A.11 CONVERGENCE Command
Defines the convergence criteria utilised during the solution. It is expressed as the relative change of the current
resultant displacement and reaction compared with the previous results for each pile cap (see Section 1.5)
Optional, default is 0.05 (5 per cent).
CONVERGE conval
Parameters
CONVERGE : keyword
conval : convergence value expressed as the ratio of the change in displacement to the previous
displacement at each pile cap. (Real)
Example
To define a 1% convergence criteria
CONVERGE 0.01
A.12 DIVISION Command
This defines the criteria employed in the pile subdivision process. Section 1.4 describes the method of
application of this command. Optional.
DIVISION value1 value2
Parameters
DIVISION : keyword
value1 : basic subdivision value as a multiplier to the pile diameter
value2 : depth modifier
Note
If the DIVISION command is not present, default values of 1.0 and 0.1 are adopted.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-11
SPLINTER User Manual Appendix A
Examples
To set the basic division to be twice the pile diameter, the modifier to remain as default (Note, both values must
be specified)
DIVISION 2.0 0.1
To set the subdivisions to be constant and equal to the pile diameter
DIVISION 1.0 0.0
A.13 OPTIONS Command
To define the control options for this run. Optional.
OPTIONS option
Parameters
OPTIONS : keyword
option : 4 character option name, or list of option names. See appendix C for details of each option.
Example
OPTION DATA GOON NOBL
A.14 RESTART Command
To define the restart stages to be executed for this run. Optional.
RESTART first (last)
Parameters
RESTART : keyword
first : number of the first restart stage to be computed by this run.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-12
SPLINTER User Manual Appendix A
last : number of the last restart stage to be computed by this run. If omitted last defaults to the last
valid restart stage for this run.
Notes
1. Appendix D contains a list of valid restart stages for SPLINTER.
2. All valid restart stages between first and last for the current analysis will be executed. Only valid restart
stage numbers must be defined for first and last.
3. first must be the next valid stage after the previous completed restart stage for the current analysis.
4. If a restart stage is not completed when a run stops, that restart stage number should be used as first on a
subsequent restart run.
Example
An example to request that the current run should execute all valid stages between the solution (Stage 5) and
stress printing (Stage 8).
RESTART 5 8
A.15 GOTP Command
Defines the point about which the resultant moments of the applied loads are calculated. (The Global Over
Turning Point). Optional.
GOTP xcoord ycoord zcoord
Parameters
GOTP : keyword
xcoord : The coordinates of the point about which the resultant forces and moments of the applied loads
ycoord are calculated. (Real)
zcoord
Note
If the GOTP command is omitted then the global origin (0,0,0) is used to calculate the resultants.
Example
GOTP 27.6 0.0 15.9
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-13
SPLINTER User Manual Appendix A
A.16 SAVE Command
To define which files or sets of files are to be saved for subsequent runs. Optional.
SAVE set (FILES)
Parameters
SAVE : keyword
set : one or more mnemonics to define the data to be saved for use in subsequent runs.
Permitted values are:
FEMS Save forces for FEMVIEW
FEMD Save global displacements for FEMVIEW
FMLD Save local displacements for FEMVIEW
FILES : keyword. (Optional)
Notes
1. If several sets of files are to be saved, they may be specified on one or several SAVE commands.
2. The use of FEMS/FEMD/FMLD save options will result in all data being output on a single formatted
FEMVIEW interface file.
A.17 UNITS Command
Compulsory.
This command allows the user to define the units to be employed in the analysis and the default units for the
input data. Facilities exist to specify the results units for output if they are required to be different from those
supplied for input (See Section A.17.2). The defined unit set will appear on each page of the printout as part of
the page header.
Facilities exist to locally modify the input data units within each main data block. See Sections 5.2.1, 5.3.1,
5.4.1 and 5.5.1 of the ASAS User Manual for further details.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-14
SPLINTER User Manual Appendix A
A.17.1 Global UNITS Definition
This specifies the units to be employed for the analysis and provides the default units for input and printed
output.
UNITS unitnm
Parameters
UNITS : keyword.
unitnm : name of unit to be utilised (see below)
The units of force and length must be supplied. Temperature is optional and defaults to centigrade. A time unit
of seconds is assumed. A default angular unit of radians is used for results reporting. The default input angular
unit varies according to the data block and must not be specified on the basic UNITS command.
Restriction
The program calculates a consistent unit of MASS based upon the length and force units supplied. The
permitted combinations of force and length are given in Appendix F.
Valid unit names
Length unit METRE(S) M
CENTIMETRE(S) CM
MILLIMETRE(S) MM
MICROMETRE(S) MICM
NANOMETRE(S) NANM
FOOT, FEET FT
INCH, INCHES IN
Force unit NEWTON(S) N
KILONEWTON(S) KN
MEGANEWTON(S) MN
TONNEFORCE(S) TNEF
POUNDAL(S) PDL
POUNDFORCE LBF
KIP(S) KIP
TONFORCE(S) TONF
KGFORCE(S) KGF
Temperature unit CENTIGRADE C
FAHRENHEIT F
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-15
SPLINTER User Manual Appendix A
Note
In substructure analyses, all components to be assembled together must use the same global units definition.
Similarly, the resulting structure must also use the same global units. If parts of the overall structure are required
to be modelled using a different set of units, the local UNITS commands within the main data should be
employed.
Example
To define the global units as Kilonewtons and Metres to be used as the analysis units and the default units for the
input data.
UNITS KN M
A.17.2 Results UNITS Command
This permits the displacements and/or stresses to be reported in different units from those supplied for the input
data.
UNITS resultnm unitnm
Parameters
UNITS : keyword
resultnm : keyword to identify results units to be modified. The following keywords are available
DISP displacement printing
STRE stress or force printing
unitnm : name of unit to be utilised. See A.17.1 for valid names.
Notes
1. For the results units, the angular term may be specified. (Default is radians).
Valid names are
RADIAN(S) RAD
DEGREE(S) DEG
2. Only those terms which are required to be modified need to be specified, undefined terms will default to
those supplied on the global units definition. For example:
UNITS N M
UNITS STRE MM
will provide stresses in terms of N/mm2
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-16
SPLINTER User Manual Appendix A
Examples
1. Input data units and results units to be in units of Kips and feet
UNITS KIPS FEET
The derived consistent unit of mass will be 3.22x104 lbs.
2. The S.I. system is to be used for input, but the displacements are to be printed in mm and the stresses in
KN/mm2
UNITS N M
UNITS DISP MM
UNITS STRE KN MILLIMETRES
Note that the reactions printed in the displacement report will be in Newtons and Millimetres.
The derived consistent unit of mass will be 1 kg.
A.18 LIBRARY Command
This command is used to provide the name of an external file which contains beam section information for use in
the geometric property data. The library file may be generated using program SECTIONS.
Only one such command line may appear in the preliminary data. See Appendix A.6 of the ASAS User Manual.
LIBRARY filenm
Parameters
LIBRARY : keyword
filenm : Name of a file which contains section library information for beam type elements (up to 6
characters).
A.19 END Command
To terminate the preliminary data. Compulsory.
END
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-17
SPLINTER User Manual Appendix A
Parameters
END : compulsory keyword.
A.20 RESU command
To specify saving of results to the database, see the database manual for the types of results that are stored by
SPLINTER for future extraction.
RESU
Parameters
RESU : Keyword
Example
RESU
Notes
(iii) As ASAS component creation does not permit the inclusion of the RESU option, it should, if required, be
specified in SPLINTER.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-18
SPLINTER User Manual Appendix A
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page A-19
SPLINTER User Manual Appendix B
B - Running Instructions for SPLINTER
B.1 ASAS Files Required by SPLINTER
SPLINTER can be used to carry out either a soil-pile analysis or a soil-pile-structure interaction analysis.
E.4.1 Files Required for a Soil-Pile Analysis
For a soil-pile analysis, SPLINTER operates in a Stand-alone mode. The data file contains all the data required
to carry out the analysis and no other files are required.
E.4.2 Files Required for a Soil-Pile-Structure Interaction Analysis
For a soil-pile-structure interaction analysis, SPLINTER operates as part of an ASAS substructure analysis. The
SPLINTER run takes the place of the ASAS global assembly run. Therefore all the backing files created by the
preceding component creation runs and the Project index file (the 10 file) must be on disk and in the user’s area.
All file assignments for these backing files are performed automatically in the same way as for an ASAS
assembly run.
B.2 Saving Files produced by SPLINTER
For a soil-pile-structure interaction analysis, the files required to carry out any stress recovery of the structure
components are saved automatically.
For all types of SPLINTER analyses, files for post-processing can be saved on request by using the SAVE
command in the Preliminary Data (see Section A.16)
B.3 Running Instructions for SPLINTER
See the appendices in the ASAS User Manual for details on how to run any of the programs in the ASAS suite.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page B-1
SPLINTER User Manual Appendix B
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page B-2
SPLINTER User Manual Appendix C
C - Valid Options for Splinter
The user is referred to the ASAS Manual Appendix C for further details on most of these options.
C.1 Miscellaneous Options
Option Name Application
NOBL Do not print the ASAS banner page at the start of the output file.
FIXD The following input data is in the old Fixed Format style. Fixed Format data
was superseded by the current Free Format style in version H09. The Fixed
Format input is still supported (as in version H08) but is no longer documented
in this manual.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page C-1
SPLINTER User Manual Appendix C
C.2 Options to control printing of data card images
If the user takes no action, SPLINTER will print the image of every data card. This printing can be prevented by
using the PRNO option. If selective printing is required, the user may specify PRNO together with the
appropriate printing option shown below. Restart stage 1 only.
Option Name Application
PRNO Print only the data selected by the options below
CCOO Print the coordinate input data
CELE Print the pile topology input data
CMAT Print the material property input data
CGEO Print the geometric property input data
CSKE Print the skew systems input data
CSEC Print the section properties input data
CSOL Print the soil input data
GROP Print the pile group definition input data
CSUP Print the suppressions input data
CDIS Print the displaced freedoms input data
CCON Print the constraint equations input data
CRCN Print the rigid constraint input data
CREL Print the released freedom input data
CLOA Print the load input data
UNCK Print the unity check input data
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page C-2
SPLINTER User Manual Appendix C
C.3 Options which control the printing of expanded data
If the user takes no action, SPLINTER will print a complete list of expanded and cross-referenced data. This
printing can be prevented by using the NODL option. If selected printing is required, the user specifies NODL
together with the appropriate printing options shown below. Restart stage 1 only.
Option Name Application
NODL Switch off the general printing of the expanded data lists and only print those
lists selected by the options below
COOR Print the coordinate data list
ELEM Print the element topology data and rigid constraints lists
MATE Print the material property data lists
GEOM Print the geometric property data lists
SECT Print the section properties data lists
SOIL Print the expanded soil data lists
PILE Print pile subdivision information
PGRP Print pile group definition information
SKEW Print the skew systems data
FDMS Print a list of freedoms and released freedoms at each node. This list also
contains information on suppressions, prescribed displacements, constraints,
links and master freedoms.
LOAD Print the loading data lists
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page C-3
SPLINTER User Manual Appendix C
C.4 Options which affect the course of the analysis
Option Name Application
DATA Stop after checking the data. When carrying out a data check run, the user
should allow the program to print a full description of the structure and loading
(do not use PRNO & NODL). This output should be thoroughly checked
before proceeding to the complete analysis.
If the check produces no Error messages, the Restart Stage 1 and 2 files will be
saved, provided that GOON is also specified. The subsequent run can omit
Stages 1 and 2 and does not require any data except the Preliminary Data,
together with a restart line to start at restart stage 3, see Appendix D.
GOON Proceed even after printed WARNINGS. This Option allows the run to
continue beyond stage 2 despite doubtful data. It should only be used after a
run in which the WARNINGS have been noted and rejected as unimportant.
ASGO Proceed after assembly warnings
PDEL Second order effects of the axial load on the bending stiffnesses of the piles are
taken into account by the inclusion of additional loading terms during the
analysis
TANG Use tangent stiffness method in derivation of soil stiffness.
SECA Use secant stiffness method in derivation of soil stiffness.
RCSD Calculate the soil displacements due to group interaction on every iteration
after initial single pile convergence. Has no effect on a single pile analysis.
See Section 1.3(iii).
INCR By default, the program assumes an initial undisplaced shape for the piles for
all loadcases and thus resets the soil properties and group effects for each new
load to be analysed. If an incremental loading is to be carried out, the option
INCR enables the solution from one loadcase to be used as an initial condition
for the next loadcase thus reducing the number of iterations required for
convergence. See Section 1.5.
NDVC Do not include the divergence check during the iteration procedure. See
Section 1.5(ii).
OVRL When generating automatic P-Y or T-Z curves, utilise the local soil density
when computing the overburden pressure at a point. This provides backwards
compatibility with versions of Splinter prior to 13.03.
AP15 When generating T-2 curves for cohesive soils. use the α calculations as set out
in the API 15th edition. This option provides backwards compatibility with
versions of SPLINTER prior to Version 14.04.01. Otherwise, the calculations
as set out in the API 21st edition will be used.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page C-4
SPLINTER User Manual Appendix C
C.5 Options which control the printing of results
SPLINTER prints the complete results, unless told otherwise, on a loadcase by loadcase basis. The following
options will modify the printing.
Option Name Application
BYEL Prints the displacements and stresses on an element by element basis rather than
loadcase by loadcase.
FORF Print the stresses and forces where possible as normal numbers without
scientific notation (exponent form). The output will default to scientific
notation if a line of output has very large or very small values. Without this
option, stress and force output will be in scientific notation.
NODI Do not print displacements and reactions. If used with NOST, a SAVE LOCO
FILES line must also be included.
NOIT Do not print iteration information. During the course of the analysis,
SPLINTER will report on the pile cap displacements and reactions after each
iteration for each loadcase. This option suppresses the report.
NOST Do not print the stresses and forces. If used with NODI, a SAVE LOCO FILES
line must also be included.
NOTR Do not write the results to the User Results Storage Database
PSTF Output the pile cap stiffness at each pile cap node and each loadcase to a
separate formatted file. The stiffness informatio is written to a file called
ssssNnnnnnnLmmmm.STF, where ssss is the name on the STRUCTURE
command, nnnnnn is the pile cap node number and mmmm is the loadcase
number.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page C-5
SPLINTER User Manual Appendix C
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page C-6
SPLINTER User Manual Appendix D
D - Restarts
SPLINTER has a built-in facility whereby any run is broken down into a series of distinct stages. At the end of
each stage the backing files are left in a condition such that, if necessary, the run can be restarted at that point.
Each of these stages is known, therefore, as a Restart Stage.
For each restart stage, SPLINTER prints message:
RESTART STAGE n STARTED
and RESTART STAGE n COMPLETED
If for any reason a run fails to complete due to lack of time, disc storage, system failure, etc., it is not necessary
to restart from the beginning of the run. The user may restart at the stage that the program was executing when
the failure occurred.
This feature may also be used directly to break down a long analysis into a series of shorter steps by selecting the
stages at which the run is to start and stop.
To restart any job, it is necessary to modify the Preliminary Data to add a RESTART command which identifies
the Start Stage and the Finish Stage for this run.
The restarted job proceeds from the beginning of the Start Stage to the end of the Finish Stage. The Start Stage
is the next one after the last stage which was completed in the previous run. The Finish Stage is usually the last
one of all.
A restarted job only needs a Preliminary Data block, the others can be omitted. All of the Preliminary Data must
be present, with the addition of the RESTART command. The TITLE and OPTIONS commands may be
changed if required, but all Options which the user wishes to retain must be restated.
The Restart Stage numbers are listed in this Appendix with a description of the process being carried out in each
stage. If a run fails due to lack of resources, it should be restarted at the current stage. If a run is restarted after a
planned intermediate stop, it should start at the next valid stage.
It is not normally possible to restart at any other stage.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page D-1
SPLINTER User Manual Appendix D
D.1 Restart Stages for SPLINTER
No. Name
1 DATAIN Read, check and file the input data
2 ASSINF Create files for assembly of piles and partitioning
3 ELSTIF Generate Pile Stiffness matrices
4 LOADEL Generate User Input Pile Load Vectors
5 SOLVES Iteration for Displacement Solution
6 DISPRN Print Converged Displacements
7 CALCST Calculation of Pile Forces and Stresses
8 PRINTS Print the Pile Forces and Stresses
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page D-2
SPLINTER User Manual Appendix D
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page D-3
SPLINTER User Manual Appendix E
E - Element Types for SPLINTER
E.1 Valid Element Types
At present only TUBE elements or BM3D/BEAM elements with tubular section are available to be modelled
directly in a SPLINTER analysis and details of this element type follow. If the user wishes to employ other
elements in modelling the superstructure, these should be assembled in an ASAS component creation analysis
and used in a soil-pile-structure interaction analysis.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page E-1
BEAM
SPLINTER User Manual Appendix E
Three-dimensional Beam Bending Element with Uniform Cross-section and Special
Orientation of the Local Axes
NUMBER OF NODES 2
NODAL COORDINATES x, y, z
DEGREES OF FREEDOM X, Y, Z, RX, RY, RZ at each node
GEOMETRIC PROPERTIES A Cross-sectional area (≥ 0.0)
(uniform) Iz”z” Principal moment of inertia about the local Z” axis (≥ 0.0)
Iy”y” Principal moment of inertia about the local Y” axis (≥ 0.0)
J Torsion constant (≥ 0.0)
The geometric properties must be defined using Section data and the section
type must be tube.
STEPS AND OFFSETS The STEP and OFFG, OFFS, OFSK, OFCO commands can be used to define
changes in the geometric properties along its length and rigid offsets at each
end. For further details see Appendix E.4.
MATERIAL PROPERTIES E Modulus of elasticity
(isotropic only) ν Poisson’s ratio
α Linear coefficient of expansion
ρ Density (mass/unit volume). See Appendix F
(α and ρ are not always needed)
LOAD TYPES Nodal loads
Prescribed Displacements
Body Force
Temperature
Distributed Load Pattern BL1, BL2, BL3, BL4, BL5,
BL6, BL7, BL8, GL1, GP1
GL4, GP4, GL5, GL6, GP6
GL7, GP7
Centrifugal Loads
MASS MODELLING Consistent Mass
Lumped Mass (used by default)
FORCE OUTPUT The forces are exerted by the nodes on the element and related to the
centroidal local axes.
Axial Force X”X” at each end
Transverse shears QY” and QZ” at each end
Torque X”X” at each end
Bending Moments Y”Y” and Z”Z” at each end
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page E-2
BEAM
SPLINTER User Manual Appendix E
LOCAL AXES A beam element has two local axes systems. The X’Y’Z’ local axes are
associated with end nodes of the element. The X”Y”Z” local axes are
associated with the end points of the centroidal axis of the element, taking
account of any non-zero rigid offsets.
If all offsets are zero, X’Y’Z’ and X”Y”Z” are coincident.
Geometric properties, distributed loads and output forces are all referred to
the X”Y”Z” local axes.
Local X” lies along the centroidal axis from end 1 towards end 2. Local Z”
must lie in the global XY plane with +ve local Y” on the +ve side of the
global XY plane. In the special case where local Y” is also in the global XY
plane, local Y” must lie in the global Y direction. BM3D should be used for a
beam with general orientation of local Z”.
SIGN CONVENTIONS Axial force positive for tension
Shear force positive for end 2 sagging relative to end 1
Torque positive for clockwise rotation of end 2
relative to end 1, looking from end 1
towards end 2 Bending moment
Positive for sagging
Shear QY” +ve Shear QZ” +ve
Moment Z”Z” +ve Moment Y”Y” +ve
Y'' Z''
1 2 1 2
X'' X''
LIMITATIONS Length must be >0.0
REFERENCE Przemieniecki J. S. “Theory of Matrix Structural Analysis”
McGraw Hill 1968.
DATA EXAMPLES ELEM
MATP 1
BEAM 9 10 3
BEAM 10 11 2
END
GEOM
2 BEAM TUBESEC1
3 BEAM TUBESEC2
END
SECT
TUBESEC1 TUB XSEC 1.5 0.06
TUBESEC2 TUB XSEC 2.0 0.1
END
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page E-3
BM3D
SPLINTER User Manual Appendix E
Three-dimensional Beam Bending Element with Uniform Cross-section and any
Orientation of the Local Axes
NUMBER OF NODES 2
NODAL COORDINATES x, y, z
DEGREES OF FREEDOM X, Y, Z, RX, RY, RZ at each node
GEOMETRIC PROPERTIES A Cross-sectional area (≥ 0.0)
(uniform) Iz”z” Principal moment of inertia about the
local Z” axis (≥ 0.0)
Iy”y” Principal moment of inertia about the
local Y” axis (≥ 0.0)
J Torsion constant (≥ 0.0)
Local Axis definition See ASAS User Manual for details.
Asy” Effective shear area in Y” direction
(Y” shear strain is neglected if Asy” is blank)
Asz” Effective shear area in Z” direction
(Z” shear strain is neglected if Asz” is blank)
The geometric properties must be defined using Section data and the sectio
type must be tube.
STEPS AND OFFSETS The STEP and OFFG, OFFS, OFSK, OFCO commands can be used to define
changes in the geometric properties along its length and rigid offsets at each
end. For further details see Appendix E.4.
MATERIAL PROPERTIES E Modulus of elasticity
(isotropic only) ν Poisson’s ratio
α Linear coefficient of expansion
ρ Density (mass/unit volume). See Appendix F
(α and ρ are not always needed)
LOAD TYPES Nodal Loads
Prescribed Displacements
Body Force
Temperature
Distributed Load Patterns BL1, BL2, BL3, BL4, BL5,
BL6, BL7, BL8, GL1, GP1
GL4, GP4, GL5, GL6, GP6
GL7, GP7
Centrifugal Loads
MASS MODELLING Consistent Mass
Lumped Mass (used by default)
FORCE OUTPUT The forces are exerted by the nodes on the element and related to the
centroidal local axes.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page E-4
BM3D
SPLINTER User Manual Appendix E
Axial Force X”X” at each end
Transverse Shears QY” and QZ” at each end
Torque X”X” at each end
Bending Moments Y”Y” and Z”Z” at each end
LOCAL AXES A beam element has two local axes systems. The X’Y’Z’ local axes are
associated with end nodes of the element. The X”Y”Z” local axes are
associated with the end points of the centroidal axis of the element, taking
account of any non-zero rigid offsets.
If all offsets are zero, X’Y’Z’ and X”Y”Z” are coincident.
Geometric properties, distributed loads and output forces are all referred to
the X”Y”Z” local axes.
Local X” lies along the centroidal axis from end 1 towards end 2. Local Y”
lies in the direction defined in the geometric properties for the element, with
its origin at end 1. Local Z” forms a right handed set with local X” and
localY”.
If a local axis definition is not supplied, a 3rd point with coordinates of
0.0,0.0,0.0 is assumed.
SIGN CONVENTIONS Axial force positive for tension
Shear force positive for end 2 sagging relative to end 1
Torque positive for clockwise rotation of end 2 relative to
end 1, looking from end 1 toward end 2
Bending moment positive for sagging
Shear QY” +ve Shear QZ” +ve
Moment Z”Z” +ve Moment Y”Y” +ve
LIMITATIONS Length must be >0.0
REFERENCE Przemieniecki J. S. “Theory of Matrix Structural Analysis”
McGraw Hill 1968
DATA EXAMPLES ELEM
MATP 1
BM3D 9 10 3
END
GEOM
3 BM3D TUBESECT -1.4 2.3 -18.1
END
SECT
TUBESECT TUB XSEC 2.0 0.1
END
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page E-5
TUBE
SPLINTER User Manual Appendix E
Three-dimensional Beam Bending Element with Uniform
Circular Cross-section
NUMBER OF NODES 2
NODAL COORDINATES x, y, z
DEGREES OF FREEDOM X, Y, Z, RX, RY, RZ at each node
GEOMETRIC PROPERTIES D External diameter ( > 0.0)
(uniform) t Wall thickness (D/2 > t > 0.0)
Local Axis definition Optional. See ASAS User Manual for details
STEPS AND OFFSETS The STEP and OFFG, OFFS, OFSK, OFCO commands can be used to define
changes in the geometric properties along its length and rigid offsets at each
end. For further details see Appendix E.4.
MATERIAL PROPERTIES E Modulus of elasticity
(isotropic only) ν Poisson’s ratio
α Linear coefficient of expansion
ρ Density (mass/unit volume). See Appendix F
(α and ρ are not always needed)
LOAD TYPES Nodal loads
Prescribed Displacements
Body Force
Temperature
Distributed Load Patterns BL1, BL2, BL3, BL4, BL5, BL6, BL7, BL8,
GL1,GP1
Centrifugal Loads
MASS MODELLING Consistent Mass
Lumped Mass (used by default)
FORCE OUTPUT The forces are exerted by the nodes on the element and related to the
centroidal local axes.
Axial Force X”X” at each end
Transverse Shears QY” and QZ” at each end
Torque X”X” at each end
Bending Moments Y”Y” and Z”Z” at each end
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page E-6
TUBE
SPLINTER User Manual Appendix E
LOCAL AXES A beam element has two local axes systems. The X’Y’Z’ local axes are
associated with end nodes of the element. The X”Y”Z” local axes are
associated with the end points of the centroidal axis of the element, taking
account of any non-zero rigid offsets.
If all offsets are zero, X’Y’Z’ and X”Y”Z” are coincident.
Step data, distributed loads and output forces are all referred to the X”Y”Z”
local axes.
If local axis data is supplied, local X” lies along the centroidal axis from end
1 towards end 2. Local Y” lies in the direction defined in the geometric
properties for the element, with its origin at end 1. Local Z” forms a right
handed set with local X” and localY”.
If local axis data is not supplied, local X” lies along the centroidal axis from
end 1 towards end 2. Local Z” must lie in the global XY plane with +ve
local Y” on the +ve side of the global XY plane. In the special case where
local Y” is also in the global XY plane, local Y” must lie in the global Y
direction. BM3D should be used for a beam with general orientation of local
Z”.
SIGN CONVENTIONS Axial force positive for tension
Shear force positive for end 2 sagging relative to end 1
Torque positive for clockwise rotation of end 2 relative to
end 1, looking from end 1 toward end 2
Bending moment positive for sagging
Shear QY” +ve Shear QZ” +ve
Moment Z”Z” +ve Moment Y”Y” +ve
Y'' Z''
1 2 1 2
X'' X''
REFERENCE Przemieniecki J. S. “Theory of Matrix Structural Analysis” McGraw Hill
1968
DATA EXAMPLES ELEM
MATP 4
GROU 6
TUBE 4 1 17
END
GEOM
17 TUBE 20000.0 17.5
END
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page E-7
SPLINTER User Manual Appendix E
E.2 Tube Section Properties
As an alternative to defining the section dimensions explicitly for the TUBE element it is possible to utilise
section definitions where a profile and physical dimensions are supplied. The sections can either be defined in
the SECT data block (see Section 3.2.10) or using an external Section Library file which can contain either
standard and/or user defined sections. For BM3D and BEAM elements, the use of section definition is
mandatory.
E.3 Stepped Tubes
The element types TUBE, BM3D and BEAM can have stepped changes in the geometric properties along the
length of a member. Each set of properties define one constant prismatic section of the beam.
Stepped properties may be defined by the STEP command in the Geometric Properties data (Section 3.2.5).
STEP commands for a member occur immediately following the Geometric Properties information for that
member.
For a stepped tube the local axes apply to the whole element and are defined by the position of the two end
points and, optionally, by the coordinates of the third point in the geometric properties for the first section.
Each stepped section must be defined in order starting with the section adjacent to node 1. There is no
restriction on the number of sections which can be defined for a member. The length of the first section is
defined as the basic set of geometric properties so, for example, the 5 geometric properties required for a tube
are increased to 6. Subsequent sections are defined by a STEP command where the new properties for that
section together with the section length are defined.
The three coordinates defining the local axes should be omitted from the STEP commands. Therefore, for
example, the TUBE requires up to 3 properties for each step.
The length of one section (including the first) may be omitted. The length of this section will be calculated by
the program.
Example of a Stepped TUBE with 3 Sections
TUBE 17.5 1.5 50.0 15.0 10.0 10.0
:STEP 15.5 1.0
:STEP 17.5 1.5 11.3
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page E-8
SPLINTER User Manual Appendix E
y'
2
x'
17.5
15.5
10.0 Undefined length 11.3
Figure E.1
E.4 Tube Element Offsets
The element types TUBE, BM3D and BEAM can have rigid offsets defined at each node.
It is normally assumed that a tube member has its centre line lying along the line joining the two end nodes and
that it is flexible throughout its length. Often, however, this is not the case. Sometimes the tube centre line is
offset from this line. It may also be appropriate when modelling the intersection of two beams at a node to
consider the end portion of one of the beams to be rigid.
Rigid offsets may be defined by the OFFG, OFFS, OFSK or OFCO command in the Geometric Properties Data.
The offset command for an element occurs after the Geometric Properties commands for that element.
One command is required for each set of geometric property data which describes a member with offsets.
An offset tube element has two local axis systems. Local X’,Y’,Z’ refer to the node points used to define the
element and X”,Y”,Z” refer to the physical ends of the element centroidal axis after the offsets have been taken
into account. If the member has no offsets then X’,Y’,Z’ and X”,Y”,Z” are coincident.
Figure A.1
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page E-9
SPLINTER User Manual Appendix E
E.4.1 OFFS Command
For the OFFS command, the local offsets are defined as the distances from the physical ends of the tube centre
line to the nodes, measured in the local X’,Y’,Z’ axes system.
Positive values of the local offsets ex, ey, ez, are as shown:
Figure A.2
Notes
1. ex at node 2 is measured in the negative x’ direction such that a shortening at either end of the beam is
given by a positive ex value.
2. The command has the keyword OFFS and the six offset values ex, ey, ez values for node 1 followed by ex,
ey, ez values for node 2.
Example
Example of an offset TUBE
175 TUBE 17.5 145.0 97.3 5.7
: 0.0 225.0 1107.0 0.0 0.0
: OFFS 12.7 4.3 0.0 0.0 4.3 0.0
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page E-10
SPLINTER User Manual Appendix E
E.4.2 OFFG and OFSK Commands
For the OFFG and OFSK commands, the offsets are defined as the distances from the nodes to the physical ends
of the tube centre line, measured in the global or skewed global axes system.
Figure A.2
Notes
1. The OFFG command has the keyword OFFG and the six offset values ex, ey, ez values for node 1
followed by ex, ey, ez values for node 2.
2. The OFSK command has the keyword OFSK followed by a skew system integer to identify the skewed
global axes system. This is then followed by 6 offset values as above.
Example
Example of offset TUBE elements.
175 TUBE 17.5 145.0 97.3 5.7
: 0.0 225.0 1107.0 0.0 0.0
: OFFG -5.0 0.0 2.0 0.0 -8.0 6.0
1 TUBE 64.2 1208.0 497.0 23.0
: OFSK 6 1.0 0.0 0.0 -1.0 0.0 5.0
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page E-11
SPLINTER User Manual Appendix E
E.4.3 OFCO Command
For the OFCO command, the global coordinates of the physical ends of the tube centre line are required.
Figure A.3
Notes
1. The command has the keyword OFCO and the 6 coordinate values x,y,z for end 1 followed by x,y,z for
end2.
Example
Example of an offset TUBE
175 TUBE 17.5 145.0 97.3 5.7
: 0.0 225.0 1107.0 0.0 0.0
: OFCO 10.0 5.0 8.0 12.0 3.0 20.0
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page E-12
SPLINTER User Manual Appendix E
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page E-13
SPLINTER User Manual Appendix F
F - Consistent Units
1 Kip = 1000 pounds force
1 Kilopond = 1 Kilogram force
All times are in seconds
Assumed specific gravity of steel = 7.85
Assumed specific gravity of concrete = 2.4
Unit of Unit Typical g Consistent Density (mass/unit volume)
force of value of E unit of
length for steel mass Steel Concrete
Newton metre 2.1x1011 9.81 1Kg 7850 2400
7 -5
Newton cm 2.1x10 981 100Kg 7.85x10 2.40x10-5
Newton mm 2.1x105 9810 1000Kg 7.85x10-9 2.40x10-9
Kilopond metre 2.14x1010 9.81 9.81Kg 800 245
Kilopond cm 2.14x106 981 981Kg 8.00x10-6 2.45x10-6
Kilopond mm 2.14x104 9810 9810Kg 8.00x10-10 2.45x10-10
KNewton metre 2.1x108 9.81 103Kg 7.85 2.40
4 5 -8
KNewton cm 2.1x10 981 10 Kg 7.85x10 2.40x10-8
KNewton mm 2.1x102 9810 106Kg 7.85x10-12 2.40x10-12
MNewtons metre 2.1x105 9.81 106Kg 7.85x10-3 2.4x10-3
MNewtons cm 2.1x101 981 108Kg 7.85x10-11 2.4x10-11
MNewtons mm 2.1x10-3 9810 109Kg 7.85x10-15 2.4x10-15
Tonne (f) metre 2.14x107 9.81 9.81x103Kg 0.800 0.245
3 5 -9
Tonne (f) cm 2.14x10 981 9.81x10 Kg 8.00x10 2.45x10-9
Tonne (f) mm 2.14x101 9810 9.81x106Kg 8.00x10-13 2.45x10-13
Poundal foot 1.39x1011 32.2 1lb 491 150
8 -2
Poundal inch 9.66x10 386 12lbs 2.37x10 7.23x10-3
Pound (f) foot 4.32x109 32.2 32.2lbs 15.2 4.66
(1 slug)
Pound (f) inch 3.0x107 386 386lbs 7.35x10-4 2.25x10-4
Kip foot 4.32x106 32.2 3.22x104lbs 1.52x10-2 4.66x10-3
Kip inch 3.0x104 386 3.86x105lbs 7.35x10-7 2.25x10-7
Ton (f) foot 1.93x106 32.2 7.21x104lbs 6.81x10-3 2.08x10-3
Ton (f) inch 1.34x104 386 8.66x105lbs 3.28x10-7 1.00x10-7
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page F-1
SPLINTER User Manual Appendix F
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page F-2
SPLINTER User Manual Appendix G
G - References
Ref. 1 Lymon C Reese, William R Cox and Francis D Koop, Analysis of Laterally Loaded
Piles in Sand,
Paper No 2080, Offshore Technology Conference 1974
Ref. 2 Hudson Mattock, Correlations for Design of Laterally Loaded Piles in Soft Clay, Paper
No 1024
Offshore Technology Conference 1970
Ref. 3 American Petroleum Institute, Recommended Practice for Planning, Designing and
Constructing Fixed Offshore Platforms, 15th Edition 1984
Ref. 4 V N Vijayvergiya, Load-Movement Characteristics of Piles, PORTS 77
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates. Page G-1
SPLINTER User Manual Appendix G