                               CITY OF SEATAC FIRE DEPARTMENT
                          REVERSE LAY STANDPIPE TASK PERFORMANCES


 QUARTER CODE: 1600 ____ DATE: ____________ HOURS:______ METHOD:______ LOC:______ SHIFT:______

                                          1. 1638– 3 Person 5:50

 Evolution #       Driver             Officer            Hydrant           Clock Time     Penalty    Total Time




 Procedure – Review back of this form for position check list and time penalties and Department Hose Manual for
 general guidelines. Each certified driver must complete 2 evolutions per quarter.

 Evolution – All evolutions use hydrant water not tank water. The engine company lays 200’ from the
 simulated fire building to a hydrant. The 5” line is anchored and connected to the standpipe connection using the
 5” x 2.5” reducer if the building is not equipped with a 5” connection. IF DRILLING AT A LOCAL
 BUILDING DO NOT CHARGE THE SUPPLY LINE. If drilling at a drill tower charge the supply line. Start
 timing when the apparatus’ front bumper passes the FDC. Stop timing the when the supply line is connected to the
 building water from the hydrant has entered the pump and the attack crew is ready to enter the fire floor.
 Equipment removed from the apparatus will be placed on the curb of the apparatus to prevent other vehicles from
 hitting it.

                                                                200 feet




 Roster
          Employee Number                        Name (Printed)                         Name (Signature)




 Created:6/01 Revised:1/02
                                   CITY OF SEATAC FIRE DEPARTMENT
                              REVERSE LAY STANDPIPE TASK PERFORMANCES

                                                        Position Check Lists

DRIVER:                                                        Penalty
Stops at building where directed by Officer                    5 sec
At command to drive, proceeds at 7-10 mph                      Failure if over 10 mph
Crosses street at or near fire scene                           30 sec
Positions apparatus at hydrant with in reach of soft suction   30 sec
Perform in cab operations                                      Failure
Sets both wheel chocks                                         Failure
Pulls supply from bed with enough extra to reach discharge     30 sec
Connects supply to discharge and opens discharge valve         30 sec
Connects soft suction to intake and opens intake valve         30 sec
Performs hydrant taking functions                              Failure
Perform Pump Panel Procedures (Open tank to pump
prime pump, set transfer valve, set pressure controller)       5 sec per missed step
Bleeds air and opens hydrant line intake                       5 sec
Checks chart and sets exact pressure                           5 sec
Adjusts intake relief valve to a trickle                       5 sec
Places end of supply back into hose bed                        5 sec
Shuts down on command                                          5 sec

OFFICER:
Directs personnel as to type of lay                           Failure
Gives short report                                            15 sec
Direct driver where to spot apparatus                         5 sec
Assists in removal of equipment                               30 sec
Properly anchors supply line/directs operator to “DRIVE”      30 sec
Connects supply to the FDC                                    10 sec
Calls for water                                               10 sec
Don SCBA in standby mode                                      60 sec
Carry’s forcible entry equipment to fire floor w/Nozzleperson Failure
Verifies Standby Team is in place before entering fire floor Failure
Don SCBA mask and backs up Nozzleperson                       Failure

HYDRANT:
See Driver’s Responsibilities Above

NOZZLE:
Removes appropriate equipment as directed by Officer           30 sec
Don SCBA in standby mode if not already done                   60 sec
Shoulder load hose bundle(s)/Proceed to fire floor w/Officer   0 sec
Checks FDC’s in stairway                                       Failure
Connects hose bundle to standpipe 1 floor below fire floor     Failure
Stretches line to fire floor/Bleeds air/Checks flow & 30
degree pattern                                                 15 sec
Don SCBA Mask/Enters fire floor with Officer                   Failure

OTHER PENALTIES:
Attack Crew not masked up                                      Failure
Simulated Standby Team not in place                            Failure
Other unsafe action                                            30 sec