RF theratest

Document Sample
RF theratest Powered By Docstoc
					                         ™
   EL-RF/3 (IgM, IgG, IgA)
 A SPECIFIC 96 WELL RHEUMATOID FACTOR
  ANTIBODY ELISA
 FDA CLEARED
 HIGH SENSITIVITY AND SPECIFICITY FOR
  RHEUMAOTID ARTHRITIS
 AUTOMATED OR MANUAL METHOD
 UNIQUE MULTIPLEX SYSTEM
 QUICK TURNAROUND TIME
 >15 YEARS PROVEN PERFORMANCE




     TheraTest Labs Inc. 1111 N. Main Street Lombard, IL 60148
     TEL: (800) 441-0771; Outside the USA or Canada: + 630 627 6069
     FAX: (630) 627-4231 www.theratest.com
    EL- RF/3TM (IgM, IgG, IgA) is used for the simultaneous detection and
    measurement of 3 different isotypes of rheumatoid factors (RF) directed rabbit
    IgG as antigen. Depending on the isotypes the sensitivity is as high as 90% and
    the specificity >96%. The test is formatted as a panel for efficient multiplex
    testing for all 3 isotypes.

    Assay Procedure                                            Assay Details
                                                                     Catalog No.                        303-305
                                                                     FDA 510 (K) Status                   Cleared
                                                                     Format                               96 Wells
                                                                     Methodology                            EIA
                                                                     Number of Tests per Kit           60 x 3 isotypes
                                                                     Standards                               3*
                                                                     Controls                                4
                                                                     Specimen Type                         Serum
                                                                     Specimen Volume                        5µl
                                                                     Sample Dilution                       1:200
      IgM and IgG specimens do not need to be                        Sensitivity / specificity IgM       91% / 76 %
      digested.                                                                           IgM + IgA     79% / 89 %
                                                                                   IgM + IgG + IgA      53 % / 99%
                                                                     Cut-offs: IgM ; IgG; IgA         25 IU; 20 U; 35 U
    Features and Benefits                                             Ranges
                                                                     Precision
                                                                                                        0- 480 U/ml


                                                                        CV's within run                    <10%
   High sensitivity/specificity testing for                            CV's between runs                  <10%
    rheumatoid arthritis
                                                                     Total Incubation Time             3 h 15 minutes

                                                                    Hands-on Time                       30 minutes
    Manual or automated efficient multiplex system
                                                                     Shelf-Life                          12 months
                                                                                                        Single Point
   Fast Turnaround Time – With minimal hands-on time                Data Reduction                     Calibration
                                                                     Wavelength                          450/630nm



                                                 Description           Catalog #                         Size

                                  EL-RF/3™ (IgM, IgG, IgA)            303-305                   60 x 3 antibody isotypes




                      CALL TOLL FREE: (800) - 441 - 0771
              TheraTest Laboratories, Inc. 1111 N. Main Street Lombard, IL 60148 USA www.theratest.com

				