					                        REF615 V2.0 ANSI HMI_LED_Label_Templates




Phone: (954) 752-6700                         ABB Inc.              Fax: (954) 345-5329
                                      Distribution Automation
                                      4300 Coral Ridge Drive
                                     Coral Springs, FL 33065
                                 www.abb.com/substationautomation
                        REF615 V2.0 ANSI HMI_LED_Label_Templates

Order code:                                          Order code:
HAFAAAAxxAE1BNNxXC or                                HAFAAAAxxAE1BANxXC or
HAFAAAAxxBE1BNNxXC or                                HAFAAAAxxBE1BANxXC or
HAFAAAAxx3E1BNNxXC                                   HAFAAAAxx3E1BNNxXC

Phase A                                              Phase A
Phase B                                              Phase B
Phase C                                              Phase C
Neutral                                              Neutral
Time                                                 Time
Instantaneous                                        Instantaneous
                                                     Recloser Lockout
Breaker Failure/Alarm                                Breaker Failure/Alarm
Overload Alarm/Trip                                  Overload Alarm/Trip




Order code:                                          Order code:
HAFAAAAxxFE1BNNxXC or                                HAFAAAAxxFE1BANxXC or
HAFAAAAxxGE1BNNxXC                                   HAFAAAAxxGE1BANxXC

Phase A                                              Phase A
Phase B                                              Phase B
Phase C                                              Phase C
Neutral                                              Neutral/Ground
Time                                                 Time
Instantaneous                                        Instantaneous
                                                     Recloser Lockout
Breaker Failure/Alarm                                Breaker Failure/Alarm
Overload Alarm/Trip                                  Overload Alarm/Trip
Arc Flash Detection                                  Arc Flash Detection




Phone: (954) 752-6700                         ABB Inc.                       Fax: (954) 345-5329
                                      Distribution Automation
                                      4300 Coral Ridge Drive
                                     Coral Springs, FL 33065
                                 www.abb.com/substationautomation
                        REF615 V2.0 ANSI HMI_LED_Label_Templates



Order code:                                          Order code:
HAFAABAxxAE1BNNxXC or                                HAFAABAxxAE1BANxXC or
HAFAABAxxBE1BNNxXC or                                HAFAABAxxBE1BANxXC or
HAFAABAxx3E1BNNxXC                                   HAFAABAxx3E1BANxXC

Phase A                                              Phase A
Phase B                                              Phase B
Phase C                                              Phase C
Neutral/Ground                                       Neutral/Ground
Time                                                 Time
Instantaneous                                        Instantaneous
                                                     Recloser Lockout
Breaker Failure/Alarm                                Breaker Failure/Alarm
Overload Alarm/Trip                                  Overload Alarm/Trip




Order code:                                          Order code:
HAFAABAxxFE1BNNxXC or                                HAFAABAxxFE1BANxXC or
HAFAABAxxGE1BNNxXC                                   HAFAABAxxGE1BANxXC

Phase A                                              Phase A
Phase B                                              Phase B
Phase C                                              Phase C
Neutral / Ground                                     Neutral / Ground
Time                                                 Time
Instantaneous                                        Instantaneous
                                                     Recloser Lockout
Breaker Failure/Alarm                                Breaker Failure/Alarm
Overload Alarm/Trip                                  Overload Alarm/Trip
Arc Flash Detection                                  Arc Flash Detection




Phone: (954) 752-6700                         ABB Inc.                       Fax: (954) 345-5329
                                      Distribution Automation
                                      4300 Coral Ridge Drive
                                     Coral Springs, FL 33065
                                 www.abb.com/substationautomation
                        REF615 V2.0 ANSI HMI_LED_Label_Templates




Order code:                                          Order code:
HAFAACAxxAE1BNNxXC or                                HAFAACAxxAE1BANxXC or
HAFAACAxxBE1BNNxXC or                                HAFAACAxxBE1BANxXC or
HAFAACAxx3E1BNNxXC                                   HAFAACAxx3E1BANxXC

Phase A                                              Phase A
Phase B                                              Phase B
Phase C                                              Phase C
Neutral / SEF                                        Neutral / SEF
Time                                                 Time
Instantaneous                                        Instantaneous
                                                     Recloser Lockout
Breaker Failure/Alarm                                Breaker Failure/Alarm
Overload Alarm/Trip                                  Overload Alarm/Trip


HIZ Detection                                        HIZ Detection


Order code:                                          Order code:
HAFAACAxxFE1BNNxXC or                                HAFAACAxxFE1BANxXC or
HAFAACAxxGE1BNNxXC                                   HAFAACAxxGE1BANxXC

Phase A                                              Phase A
Phase B                                              Phase B
Phase C                                              Phase C
Neutral / SEF                                        Neutral / SEF
Time                                                 Time
Instantaneous                                        Instantaneous
                                                     Recloser Lockout
Breaker Failure/Alarm                                Breaker Failure/Alarm
Overload Alarm/Trip                                  Overload Alarm/Trip
Arc Flash Detection                                  Arc Flash Detection
HIZ Detection                                        HIZ Detection




Phone: (954) 752-6700                         ABB Inc.                       Fax: (954) 345-5329
                                      Distribution Automation
                                      4300 Coral Ridge Drive
                                     Coral Springs, FL 33065
                                 www.abb.com/substationautomation
                        REF615 V2.0 ANSI HMI_LED_Label_Templates

Order code:                                          Order code:
HAFDDADAxAE1BNNxXC or                                HAFDDADAxAE1BANxXC or
HAFDDADAxBE1BNNxXC or                                HAFDDADAxBE1BANxXC or
HAFDDADAx3E1BNNxXC                                   HAFDDADAx3E1BANxXC

Phase A                                              Phase A
Phase B                                              Phase B
Phase C                                              Phase C
Neutral / Ground                                     Neutral / Ground
Time                                                 Time
Instantaneous                                        Instantaneous
                                                     Recloser Lockout
Voltage                                              Voltage
Overload Alarm/Trip                                  Overload Alarm/Trip




Order code:                                          Order code:
HAFDDADAxFE1BNNxXC or                                HAFDDADAxFE1BANxXC or
HAFDDADAxGE1BNNxXC                                   HAFDDADAxGE1BANxXC

Phase A                                              Phase A
Phase B                                              Phase B
Phase C                                              Phase C
Neutral / Ground                                     Neutral / Ground
Time                                                 Time
Instantaneous                                        Instantaneous
                                                     Recloser Lockout
Voltage                                              Voltage
Overload Alarm/Trip                                  Overload Alarm/Trip
Arc Flash Detection                                  Arc Flash Detection




Phone: (954) 752-6700                         ABB Inc.                     Fax: (954) 345-5329
                                      Distribution Automation
                                      4300 Coral Ridge Drive
                                     Coral Springs, FL 33065
                                 www.abb.com/substationautomation
                        REF615 V2.0 ANSI HMI_LED_Label_Templates

Order code:                                          Order code:
HAFDDBDAxAE1BNNxXC or                                HAFDDBDAxAE1BANxXC or
HAFDDBDAxBE1BNNxXC or                                HAFDDBDAxBE1BANxXC or
HAFDDBDAx3E1BNNxXC                                   HAFDDBDAx3E1BANxXC

Phase A                                              Phase A
Phase B                                              Phase B
Phase C                                              Phase C
Neutral / SEF                                        Neutral / SEF
Time                                                 Time
Instantaneous                                        Instantaneous
                                                     Recloser Lockout
Voltage                                              Voltage
Overload Alarm/Trip                                  Overload Alarm/Trip


HIZ Detection                                        HIZ Detection


Order code:                                          Order code:
HAFDDBDAxFE1BNNxXC or                                HAFDDBDAxFE1BANxXC or
HAFDDBDAxGE1BNNxXC                                   HAFDDBDAxGE1BANxXC

Phase A                                              Phase A
Phase B                                              Phase B
Phase C                                              Phase C
Neutral / SEF                                        Neutral / SEF
Time                                                 Time
Instantaneous                                        Instantaneous
                                                     Recloser Lockout
Voltage                                              Voltage
Overload Alarm/Trip                                  Overload Alarm/Trip
Arc Flash Detection                                  Arc Flash Detection
HIZ Detection                                        HIZ Detection