4670010pdf

Document Sample
4670010pdf Powered By Docstoc
					- - - - - - - - - - - - - - - - MATERIAL SAFETY DATA SHEET - - - - - - - - - - - - - - Boehringer Ingelheim
MANUFACTURER: BOEHRINGER INGELHEIM ANIMAL HEALTH, INC. 2621 NORTH BELT HIGHWAY ST JOSEPH, MISSOURI 64502 TELEX: 42 6205 PHONE: 816-233-2571 ----------------------------------------------------------SECTION I. MATERIAL IDENTIFICATION ----------------------------------------------------------NO.: 495-521 REVIEWED: 10/07/85 MATERIAL NAME: Anchor Antibiotic Combination OTHER DESIGNATIONS: None. CHEMICAL FAMILY: Veterinary Injectable Antibiotic TRADE NAME: See Above ----------------------------------------------------------SECTION II. INGREDIENTS AND HAZARDS ----------------------------------------------------------INGREDIENTS % OSHA HAZARD DATA/ AND HAZARDS PEL TOXICITY ----------------------------------------------------------Procaine 22.1 LD50, IPR, Penicillin G (minimum) Mouse 146 mg/kg Dihydrostreptomycin 25.0 LD50, IVN, Rat 200 mg/kg Procaine Hydrochloride 2.0 LD50, Oral, Rat 200 mg/kg Inert Ingredients 50.9 determined to be NonHazardous as defined by 29 CFR Part 1910, November 1983. ----------------------------------------------------------SECTION III. PHYSICAL DATA ----------------------------------------------------------BOILING POINT at 1 atm, deg C: Approximately 110 degrees C VAPOR PRESSURE at 15 deg C, mm Hg: Unknown VAPOR DENSITY (AIR = 1): Unknown WATER SOLUBILITY at 20 deg C: Material forms suspensions or emulsions with water. SPECIFIC GRAVITY, 20/4 deg C: >1.0 EVAP. RATE (BuAc = 1): Unknown VOLATILES, %: Approximately 50% at 100 degrees C. MOLECULAR WEIGHT: Not Applicable - Chemical Mixture APPEARANCE & ODOR: Practically odorless milky liquid. ----------------------------------------------------------SECTION IV. FIRE AND EXPLOSION DATA ----------------------------------------------------------Not Applicable-material will not ignite. FLASH POINT AND METHOD: Not Applicable. AUTOIGNITION TEMP.: Not Applicable. FLAMMABILITY LIMITS IN AIR: Not Applicable. LOWER: NA UPPER: NA EXTINGUISHING MEDIA: As appropriate for surrounding materials. SPECIAL FIRE FIGHTING PROCEDURES: Although material will not ignite, if heated strongly in a fire situation carbon dioxide, carbon monoxide, oxides of nitrogen and other noxious fumes may result. NIOSH approved full protective gear for firefighters is recommended if material is involved in a major fire. ----------------------------------------------------------SECTION V. REACTIVITY DATA ----------------------------------------------------------STABILITY: Stable. CONDITIONS TO AVOID: Extreme Heat. INCOMPATIBLE WITH: Strong acids will degrade active ingredients. HAZARDOUS DECOMPOSITION PRODUCTS: Carbon Dioxide, Carbon Monoxide, Oxides of Nitrogen and other noxious fumes if heated to decomposition. HAZARDOUS POLYMERIZATION: Will not occur CONDITIONS TO AVOID: None Known.

ANCHOR ANTIBIOTIC COMBINATION
----------------------------------------------------------SECTION VI. HEALTH HAZARD INFORMATION ----------------------------------------------------------EFFECTS OF OVEREXPOSURE: Penicillin compounds may cause allergic reactions and anaphylaxis in sensitized individuals. Persons sensitive to penicillins should use extreme care when handling this product. Dihydrostreptomycin is generally well-tolerated by humans and adverse effects usually take the form of skin reactions or irritation. Procaine hydrochloride is a local anesthetic and may cause numbness of skin or other membranes on prolonged contact. TARGET ORGANS: Central Nervous System and Skin in sensitive individuals. PRIMARY ROUTES OF ENTRY: Skin and Eye contact, Ingestion, Inhalation. FIRST AID: EYE CONTACT: Flush eyes with water. Notify physician if irritation persists. SKIN CONTACT: Remove contaminated clothing and wash affected areas with soap and water. INHALATION: Remove victim to fresh air. Apply artificial respiration if indicated. INGESTION: Notify physician or poison control center if ingested and adverse effects are observed. Epinephrine may be administered if victim shows signs of anaphylactic shock. ----------------------------------------------------------SECTION VII. SPILL, LEAK, AND DISPOSAL PROCEDURES ----------------------------------------------------------SPILLS, LEAKS: Contain spill to avoid contamination of environment. Absorb spill using suitable absorbent (vermiculite, etc.), drum up into steel containers for legal disposal. Avoid contamination of other materials with penicillin. DISPOSAL: Dispose of containers and unused product in accordance with Local, State, and Federal Hazardous Waste Regulations. ----------------------------------------------------------SECTION VIII. SPECIAL PROTECTION INFORMATION ----------------------------------------------------------RESPIRATORY PROTECTION: NIOSH approved respirator equipped with organic vapor/mist cartridge if sensitive to penicillins. VENTILATION: Use product in well-ventilated area if sensitive to penicillins. PROTECTIVE GLOVES: Rubber, Neoprene or Viton if sensitive to penicillins. EYE PROTECTION: Safety Glasses/Goggles OTHER PROTECTIVE EQUIPMENT: None specially recommended. ----------------------------------------------------------SECTION IX. SPECIAL PRECAUTIONS AND COMMENTS ----------------------------------------------------------STORAGE & HANDLING INFORMATION: READ AND FOLLOW ALL LABEL DIRECTIONS Maintain product sterility. Store away from heat. Keep container tightly closed when not in use. DOT CLASS: None. ---------------------------------------------------------Approvals ----------------------------------------------------------Delbert T. Jeter, Director, Quality Assurance - 10/21/85 John R. Carpenter, Manager, Environmental & Product Safety - 10/10/85

Page 1 of 2

- - - - - - - - - - - - - - - - MATERIAL SAFETY DATA SHEET - - - - - - - - - - - - - - Boehringer Ingelheim
----------------------------------------------------------Judgements as to the suitability of information herein for purchaser's purposes are necessarily purchaser's responsibility. Therefore, although reasonable care has been taken in the preparation of such information, Boehringer Ingelheim Animal Health, Inc. extends no warranties, makes no representations and assumes no responsibility as to accuracy or suitability of such information for application to purchaser's intended purposes or for consequences of its use. ----------------------------------------------------------DISCLAIMER OF EXPRESSED AND IMPLIED WARRANTIES: Although reasonable care has been taken in the preparation of this document, we extend no warranties and make no representation as to the accuracy or completeness of the information contained therein, and assume no responsibility regarding the suitability of this information for the user's intended purposes or for the consequences of its use. Each individual should make a determination as to the suitability of the information for their particular purpose(s). A request has been made to the manufacturer to approve the contents of this material safety data sheet. Upon receipt a new MSDS will be made available. ----------------------------------------------------------COMPAS Code: 46700100

ANCHOR ANTIBIOTIC COMBINATION

Page 2 of 2


				
DOCUMENT INFO
Shared By:
Categories:
Tags:
Stats:
views:5
posted:9/30/2009
language:English
pages:2