Planmeca Proline XC

Shared by: uht526
Categories
Tags
-
Stats
views:
76
posted:
5/20/2012
language:
English
pages:
25
Document Sample
scope of work template
							Planmeca Proline XC




        the eXCellent panoramic X-ray
         the best choice for dental office




• Easy to operate
• Open and easy patient access
• Side entry and open view
    • No mirror, no traumatic view of injuries
• Triple laser beam system for accurate alignment   2
intuitive controls
              Graphic User Interface (GUI) for
              intuitive selection of the wanted
              program and exposure
              parameters.




                                                  3
            clear access for all patients
• Wheelchair patients
• Patient in hospital bed
• Children can see the accompanying
  parent




                                            4
clear and sharp images

             • The focal layer shape is based on
               scientific study on human jaw shape




             • Planmeca Proline XC images have
               constant magnification




                                                     5
                    clear and sharp images

• Jaw shape and size vary according to
  age, gender and race
• Adjustable focal layer to fit different
  patient’s anatomy

size:
        small – medium - large
shape:
        narrow – average – square




                                             6
clear and sharp images
            • The path of the rotating centre of the
              radiation beam influences the image
              quality
            • Long path starting and ending well
              outside the jaw
                  less radiation
                  less shadows
            • Planmeca Proline XC images have no
              ghost shadows
                  high diagnostic quality even in
                   cases with metallic items in the
                   object




                                                       7
               clear and sharp images
                                          • Elimination of the cervical column
                                            shadow
                                               • reduced rotation speed at the
                                                 central incisor region
                                                uniform darkness, and contrast




                                          • Constant potential (DC) generator
                                           less radiation to patient
                                           improved contrast
                                           reproducible images

    Constant potential x-ray generation
k
V




                                      t


    Conventional x-ray generation
k
V




                                                                                  8
                                      t
            successful images every time
                                  Film:
                                  AEC Automatic Exposure Control
                                  • anatomic structures vary between
continuous adjustment   measure     patients
                                  • automatic selection of exposure
                                    parameters
                                       • initial measurement
                                       • continuous adjustment
                                  • selection of target film darkness (optical
                                    density) level
                                  Digital:
                                  AGC Automatic Gain Control
                                  • Optimizes the image quality by adjusting
                                    the sensitivity of the sensor according to
                                    the amount of incoming radiation.
                                  • Prevents pixel saturation even in soft
                                    tissue and direct radiation areas




                                                                                 9
high-tech digital imaging system
                Planmeca Dimax
                • Combined digital panoramic and
                  cephalometric system
                • Digital sensor employs latest CCD
                  technology
                • Extremely fast image information
                  transfer
                • Eliminates the use of film, film processor
                  and darkroom



                 the most advanced digital panoramic X-
                  ray system available




                                                               10
high-tech digital imaging system
                 Dimax sensor
                 • Sensitive area: 9 x 136 mm
                 • Pixel size: 33 µm (binning: 66 / 99 /
                   132 µm)
                 • Short decay time scintillator
                 • Very high signal to noise ratio (SNR)
                 • Very high detective quantum efficiency
                   (DQE)
                 • Dynamic range: 17 bit, 131072 grey
                   values
                 • Data transfer: fast data link (10 MB/s)
                   between sensor and computer

                  excellent images
                  real time imaging




                                                             11
high-tech digital imaging system
                 Dimaxis Pro software
                 • Real-time image acquisition
                 • Image enhancement
                      • Contrast / darkness
                      • Flashlight
                      • Multiple filters
                 • Measurements
                 • Annotations
                 • all in one dental imaging
                      • Planmeca Dixi®3
                      • Intracam
                 • DICOM compatibility meeting all ADA
                   service level requirements
                      • DICOM Basic
                      • DICOM Advanced
                 • Planmeca TWAIN




                                                         12
functional exposure programs
                   Standard panoramic program




                   Paediatric program
                   • reduced area from sides
                   • 20% less patient radiation
                     dose




                                                  13
functional exposure programs

                   Vertical segmenting
                    limited exposure of the
                     diagnostically interesting area
                    minimum radiation to patient
                    reduces the patient dose up to
                     80%




                                                       14
functional exposure programs
                  Automatic TMJ program
                  • TMJ views with mouth closed
                    and open on one film




                  Maxillary sinus program
                  • Special focal layer




                                                  15
easy cephalometry
         Proline CM Cephalostat
         • automatic alignment of the tube head
         • motorised aperture selection
         • soft tissue filter positioning from control
           panel




          Can also be added to the Planmeca
           Proline XC unit any time in the future




                                                         16
                  easy cephalometry
                                       Proline Cephalostat


                                       • Best cephalometric system
                                         for all radiographic
                                         projections




        lateral             AP/PA




submento-vertex   water’s    towne’s                                 17
easy cephalometry
              Dimax Cephalostat


              • Same movable digital
                sensor for panoramics and
                cephalometry
              • Optionally two fixed digital
                sensors
              • Field height 23 cm
              • Field width 18 - 27 cm
                (adjustable)

               image field cover also the
                back of the skull
               image size according to
                diagnostic need
               reduced radiation to patient




                                               18
easy cephalometry
             Horizontal scanning


             • the sensor moves horizontally
               (Scanning time 17 s)
             • X-ray beam turns around the
               focus




              magnification equal in both
               directions = no distortion
              allows field width of up to 29
               cm = whole skull




                                                19
easy cephalometry

                • Soft tissue filtration
                  done in the Dimaxis
                  imaging software


                 no need for a
                  mechanical filter
                 possible to view the
                  image with and without
                  the filter




                                           20
secure image storage
           Solid database
           = Integrated professional database for
             image storage and administration

           •   Long-term archiving
           •   Automatic recovery system
           •   Built-in warning system
           •   Automated back-up




            secure storage of images
            no lost information even if computer
             system crashes




                                                    21
      computer system requirements
SERVER PC (recommended)
    Processor: Pentium III
    RAM: 256 MB or more
    Hard Disc: 2 x 80 GB
    Local bus: PCI, USB
    CD-ROM drive
    Backup medium: MO disc, DAT or other
    Operating system: Windows 2000, XP, 2003
CLIENT PC (minimum)
    Processor: Pentium III
    RAM: 256 MB or more
    Hard Disc: 50 Mb free space
    Local bus: PCI
    CD-ROM drive
    Operating system: Windows 2000, XP, 2003




                                               22
film marking
       Autoprint
       • Automatic film marking during exposure
       • All necessary information
            • patient ID
            • clinic/doctor ID
            • exposure parameters
            • date, time and film orientation


        no more mixed images
        easy to reproduce images at later times
        easy and systematic way to document
         images




                                                   23
film marking
       Admark
       • Film marker for any green sensitive film
       • Used with Autoprint or as stand alone
       • All necessary information
           • patient ID
           • clinic/doctor ID
           • exposure parameters
           • date, time, ceph projection and film
             orientation


        no more mixed images
        easy to reproduce images at later times
        easy and systematic way to document
         images




                                                    24
                                  the end




More information:
Mr. Erkki Hiltunen                    Mrs. Sari Mäkinen
Product Manager, X-ray Division       Product Specialist, X-ray Division
tel: +358 20 7795 456                 tel: +358 20 7795 469
erkki.hiltunen@planmeca.com           sari.makinen@planmeca.com
www.planmeca.com                                                           25

						
Related docs
Other docs by uht526
10 DIARIO CONCURSAL 2010 12 08
Views: 60  |  Downloads: 0
REAL DECRETO 509, 15/3/96
Views: 3  |  Downloads: 0
Day2 MUAC
Views: 13  |  Downloads: 0
nmr 2012 day 1
Views: 4  |  Downloads: 0
Prior to Motorola
Views: 3  |  Downloads: 0
Planmeca Proline XC
Views: 81  |  Downloads: 0
Summer Fitness Packet
Views: 9  |  Downloads: 0