Planmeca Proline XC
Shared by: uht526
-
Stats
- views:
- 76
- posted:
- 5/20/2012
- language:
- English
- pages:
- 25
Document Sample


Planmeca Proline XC
the eXCellent panoramic X-ray
the best choice for dental office
• Easy to operate
• Open and easy patient access
• Side entry and open view
• No mirror, no traumatic view of injuries
• Triple laser beam system for accurate alignment 2
intuitive controls
Graphic User Interface (GUI) for
intuitive selection of the wanted
program and exposure
parameters.
3
clear access for all patients
• Wheelchair patients
• Patient in hospital bed
• Children can see the accompanying
parent
4
clear and sharp images
• The focal layer shape is based on
scientific study on human jaw shape
• Planmeca Proline XC images have
constant magnification
5
clear and sharp images
• Jaw shape and size vary according to
age, gender and race
• Adjustable focal layer to fit different
patient’s anatomy
size:
small – medium - large
shape:
narrow – average – square
6
clear and sharp images
• The path of the rotating centre of the
radiation beam influences the image
quality
• Long path starting and ending well
outside the jaw
less radiation
less shadows
• Planmeca Proline XC images have no
ghost shadows
high diagnostic quality even in
cases with metallic items in the
object
7
clear and sharp images
• Elimination of the cervical column
shadow
• reduced rotation speed at the
central incisor region
uniform darkness, and contrast
• Constant potential (DC) generator
less radiation to patient
improved contrast
reproducible images
Constant potential x-ray generation
k
V
t
Conventional x-ray generation
k
V
8
t
successful images every time
Film:
AEC Automatic Exposure Control
• anatomic structures vary between
continuous adjustment measure patients
• automatic selection of exposure
parameters
• initial measurement
• continuous adjustment
• selection of target film darkness (optical
density) level
Digital:
AGC Automatic Gain Control
• Optimizes the image quality by adjusting
the sensitivity of the sensor according to
the amount of incoming radiation.
• Prevents pixel saturation even in soft
tissue and direct radiation areas
9
high-tech digital imaging system
Planmeca Dimax
• Combined digital panoramic and
cephalometric system
• Digital sensor employs latest CCD
technology
• Extremely fast image information
transfer
• Eliminates the use of film, film processor
and darkroom
the most advanced digital panoramic X-
ray system available
10
high-tech digital imaging system
Dimax sensor
• Sensitive area: 9 x 136 mm
• Pixel size: 33 µm (binning: 66 / 99 /
132 µm)
• Short decay time scintillator
• Very high signal to noise ratio (SNR)
• Very high detective quantum efficiency
(DQE)
• Dynamic range: 17 bit, 131072 grey
values
• Data transfer: fast data link (10 MB/s)
between sensor and computer
excellent images
real time imaging
11
high-tech digital imaging system
Dimaxis Pro software
• Real-time image acquisition
• Image enhancement
• Contrast / darkness
• Flashlight
• Multiple filters
• Measurements
• Annotations
• all in one dental imaging
• Planmeca Dixi®3
• Intracam
• DICOM compatibility meeting all ADA
service level requirements
• DICOM Basic
• DICOM Advanced
• Planmeca TWAIN
12
functional exposure programs
Standard panoramic program
Paediatric program
• reduced area from sides
• 20% less patient radiation
dose
13
functional exposure programs
Vertical segmenting
limited exposure of the
diagnostically interesting area
minimum radiation to patient
reduces the patient dose up to
80%
14
functional exposure programs
Automatic TMJ program
• TMJ views with mouth closed
and open on one film
Maxillary sinus program
• Special focal layer
15
easy cephalometry
Proline CM Cephalostat
• automatic alignment of the tube head
• motorised aperture selection
• soft tissue filter positioning from control
panel
Can also be added to the Planmeca
Proline XC unit any time in the future
16
easy cephalometry
Proline Cephalostat
• Best cephalometric system
for all radiographic
projections
lateral AP/PA
submento-vertex water’s towne’s 17
easy cephalometry
Dimax Cephalostat
• Same movable digital
sensor for panoramics and
cephalometry
• Optionally two fixed digital
sensors
• Field height 23 cm
• Field width 18 - 27 cm
(adjustable)
image field cover also the
back of the skull
image size according to
diagnostic need
reduced radiation to patient
18
easy cephalometry
Horizontal scanning
• the sensor moves horizontally
(Scanning time 17 s)
• X-ray beam turns around the
focus
magnification equal in both
directions = no distortion
allows field width of up to 29
cm = whole skull
19
easy cephalometry
• Soft tissue filtration
done in the Dimaxis
imaging software
no need for a
mechanical filter
possible to view the
image with and without
the filter
20
secure image storage
Solid database
= Integrated professional database for
image storage and administration
• Long-term archiving
• Automatic recovery system
• Built-in warning system
• Automated back-up
secure storage of images
no lost information even if computer
system crashes
21
computer system requirements
SERVER PC (recommended)
Processor: Pentium III
RAM: 256 MB or more
Hard Disc: 2 x 80 GB
Local bus: PCI, USB
CD-ROM drive
Backup medium: MO disc, DAT or other
Operating system: Windows 2000, XP, 2003
CLIENT PC (minimum)
Processor: Pentium III
RAM: 256 MB or more
Hard Disc: 50 Mb free space
Local bus: PCI
CD-ROM drive
Operating system: Windows 2000, XP, 2003
22
film marking
Autoprint
• Automatic film marking during exposure
• All necessary information
• patient ID
• clinic/doctor ID
• exposure parameters
• date, time and film orientation
no more mixed images
easy to reproduce images at later times
easy and systematic way to document
images
23
film marking
Admark
• Film marker for any green sensitive film
• Used with Autoprint or as stand alone
• All necessary information
• patient ID
• clinic/doctor ID
• exposure parameters
• date, time, ceph projection and film
orientation
no more mixed images
easy to reproduce images at later times
easy and systematic way to document
images
24
the end
More information:
Mr. Erkki Hiltunen Mrs. Sari Mäkinen
Product Manager, X-ray Division Product Specialist, X-ray Division
tel: +358 20 7795 456 tel: +358 20 7795 469
erkki.hiltunen@planmeca.com sari.makinen@planmeca.com
www.planmeca.com 25
Get documents about "