DTC Art 5218 Domestic Thermostatic Mixing Valve 22mm by AdvancedWaterCo

VIEWS: 8 PAGES: 1

More Info
									                                           DTC Art 5218 Thermostatic
                                           Mixing Valve - 22mm

                                             2   1   MIN   MAX 7

                   C


                                             C                 H              A




                                                                                  Dimensions:
                   D
                                                                                  A:              22mm
                                                                                  B:              75.5mm
                                                                                  C:              55mm
                                                     A                            D:              90.5mm
                                      B                            B

  Application:
  A tempering valve is used in systems were the water in the storage cylinder can reach
  temperatures significantly above 60C for example if heated by solar heating. They are used
  with multiple outlets and frequently as part of a re-circulating domestic hot water system.
  In the event of failure of the hot or cold water supplies the Art 5218 will automatically
  shut down in line with the BS EN 15092 test standard.

  BS EN 10592 and DTC Scheme:
  BS EN 15092 "In line hot water supply tempering valves. Tests and requirements" specifies
  the performance characteristics of tempering valves installed at the point of distribution in
  domestic hot water systems. Art 5218 tempering valves are certified by Buildcert and the
  DTC Scheme as meeting these requirements.

   Construction:
   Body             DZR Brass         BS E N 12165CW602N
                                      Chrome Plated
   Shutter          PSU
   Spring           Stainless steel
   Seals            EPDM
   Cover            ABS

   Details:
   Maximum inlet pressure:                       10 bar Static
                                                 5 bar Dynamic
   Maximum inlet temperature:                    90°C
   Maximum temperature ratio H/C or C/H:         2:1
   Minimum temperature difference
   between hot water inlet and mixed
   water outlet for best performance:            10°C
   Temperatures setting range:                   45-65°C
   BS EN set temperature range:                  45-65°C
   Set water temperature:                        55-65°C
   Accuracy:                                     ±2°C
   Minimum flow rate for stable operation:       4 l/m


  Advanced Water Company, Unit D5 The Enterprise Centre, Off Enterprise Way, Vale Park, Evesham
Worcestershire, WR11 1GS TEL: 0845 076 6144 FAX: 01386 760077 EMAIL: sales@advancedwater.co.uk

								