SPECIFICATIONS for 500 V FUSE- BASES _HOLDERS_ 400A

Shared by: electricityworld
Categories
Tags
-
Stats
views:
12
posted:
5/1/2012
language:
Arabic
pages:
4
Document Sample
scope of work template
							               ‫وزارة الكــــــــهــــــــــربـــــاء‬
                            ‫والـــــــــطــــاقــــة‬
‫الشركـــة القابــــــضــة لكهربـــــــاء مصــــــــر‬
        ‫اللجنة الدائمة لتطوير المواصفـــات الفنيــة‬




                 ‫‪SPECIFICATIONS‬‬
                       ‫‪FOR‬‬
         ‫‪500 V FUSE- BASES (HOLDERS) 400A‬‬
                                 SPECIFICATIONS
                                           FOR
                     500 V FUSE-BASES (HOLDERS) 400A
SCOPE
  The specification applies for L.V. fuse-bases (holders) which are suitable for
  inserting fuse link with blade contacts of size 2 for base 400A according to IEC269
  “Network, 400/231 v, 50 HZ, and ambient temperature up to 45˚C.
1- RELEVANT STANDARDS
  IEC 60269-1, 60269-2 & 60269-2-1/86-87 (or latest editions).
2- CONSTRUCTION REQUIREMENTS
  -   Rated current (IEC 269-2-1)                     400 A
  -   Rated voltage (A.C.50HZ)                        500 V.
  -   Rated power acceptance of fuse holder           IEC 269-2-1
  -   Insulating properties                           IEC 269-1
  -   The main contacts for fuse-holders shall be electrolytic copper (pure copper 99.99%)
      heavily silver plated with thickness 4-8 microns to ensure good contact according to
      IEC related.
  -   The contact surface area shall be > 450 mm2 at each contact’s face of every fuse link
      end (2 faces at each end) , the copper contacts should be fixed by two bolts , each bolt
      shall be complete with one washer and nut.
  -   The insulation of each fuse-base shall be one glazed porcelain, and shall carry safely
      the full rated current permanently and the short circuit current recommended for fuse
      holders of fuse links of rated current 400 A, Breaking Capacity 50 KA r.m.s or peak
      current > 100 KA
  -   With each fuse holder 2 galvanized bolts shall be supplied. Each bolt shall
      be completed with 2 washers, one spring washer and one nut, all washers
      and nuts shall be galvanized. The bolts shall be ⅜ inch or 10 mm.



                                              1
   -   The element of each fuse base shall not contain any harmful substances
       such as (aspestos, uria,…..etc).
3 - MARKING
   Each fuse-holder shall be marked at least size and rated current or reference and
   manufacturer’s name or trade mark and Distribution Company badge.
4- Tests :
Tests shall be made in accordance with IEC 269
5- Guarantee schedule :
guarantee schedule attached shall be duly completed and signed and submitted with the offer.




                                             2
                                  GUARANTEE SCHEDULE FOR
                                            FUSES–BASE 400 A.
PARTICULARS
1 - Maker's name .......................................................................…………..........
2 - Standard specifications applied .........................................………..............
3 - Rated current .......................................................................…………............. amp.
4 - Rated voltage .....................................................................……..…….............. volts
5 - Frequency...................................................................…………………………. (HZ)
6- Rated breaking capacity ........................................................…………....…....... KA
7 - Material and cross-section area of main contacts (width × thickness) ….. mm x mm
8 – Surface contact area of main contacts with fuse link ……………..……......... mm2
9- Material of coating of copper contacts ……………............…………..........…. mm2
10- Material of insulating part ...............................................……..........................
11- Weight of fuse base..........................................................………............... …gm
12- Dimensions of fuse base :
     a) Length ...................................................………..........................................mm
     b) Width ........................................................………...............................…...mm
     c) Height ...........................................................……….........................…..... mm




                                                             3

						
Related docs
Other docs by electricityworld
Technical specifications22 K V
Views: 0  |  Downloads: 0
Specification for low voltage fuses
Views: 4  |  Downloads: 0
Specifications of over ct_ s.c_ef
Views: 0  |  Downloads: 0
Technical specifications 11 KV fuse with base1
Views: 11  |  Downloads: 0
Specification of main ring unit with fuse777
Views: 0  |  Downloads: 0
Specifications of over ct_ s.c_ef1
Views: 2  |  Downloads: 0
Specifications 2 of outdoor 12
Views: 4  |  Downloads: 0