Docstoc

DSView 3 v3 7 0 156 Patch Release - Avocent DSView 3 Software

Document Sample
DSView 3 v3 7 0 156 Patch Release - Avocent DSView  3 Software Powered By Docstoc
					             Avocent DSView® 3 Management Software Update Patch
                              Release 3.7.0.156
                               July 24th, 2009


This document outlines:
1. Update Instructions
2. Language Support Information
3. Known Issues
4. Change Log

=======================================================================
                           Update Instructions
=======================================================================
This patch updates DSView 3 software version 3.7.0.124 (April 3, 2009)
to DSView 3 software Patch Version 3.7.0.156 (July 24th, 2009). This
patch is provided as a full installation package.


Update Patch Installation

    Note: Since this patch is provided as a full installation package,
     there is no way to manually remove this patch.
    Please see the document entitled “DSView 3 Server Release 3.7.0.156
     Memory Improvement Settings”, which describes the steps necessary to
     improve the memory usage and performance of DSView 3 software.
     Please contact Avocent Technical Support for download instructions.
    A Replication should be performed on all spokes in the current
     system.
      Backup the DSView 3 server. See “Manually backing up and
        restoring hub servers” section of the online help for additional
        information.
    The patch needs to be applied to each DSView 3 server (hub and each
     spoke).
    For installation on a supported Windows® system:
     o Run the setup.exe and then follow the on screen instructions.
    For installation on a Linux® and SolarisTM system:
     o From a command line type ./install.sh and then follow the on
        screen instructions.

Note: If an upgrade from DSView 3 server version 3.7.0.124 to 3.7.0.156
is performed, the following steps should be performed prior to
launching the first KVM session to eliminate problems with the Virtual
Media Client.

1.   Close down all Microsoft Internet Explorer windows.
2.   Reopen Internet Explorer.
3.   Go to Tools/Internet Options. Select the Programs panel.
4.   Click on the Manage add-ons button.
5.   Select the Avocent DSView session launcher and press Delete.

=======================================================================
                      Language Support Information
=======================================================================
The language supported by this patch is English, Simplified Chinese,
Japanese, and Korean.
=======================================================================
                              Known Issues
=======================================================================


   Problems have been found with the “Merge Target Endpoints” feature
    under the Tools -> Unit Tools page. When merging targets and
    outlets, it is recommended that one of these steps is followed:

    1. Drill down to the target device and click on the Merge Target
       Devices tool.
    2. From the Tools Page on the Units View, select the Merge Target
       Devices tool.

   When merging a KVM target to an Avocent Power Management
    Distribution Unit (PM PDU) outlet and then adding it to Power
    Management rack, if a second merge of another outlet to the same KVM
    target is performed, the data from the two outlets is never added
    together. To prevent this issue, merge the PM PDU outlets to the KVM
    targets before adding the items to a rack.


=======================================================================
                               Change Log
=======================================================================
The following issues were fixed with this update:

   A cascaded AutoView® switch was not correctly displaying the number
    of ports the AutoView switch owned.
   PuTTY session remained open after logging out of DSView 3 software.
   Loss Communication (LCM) errors were not being reported properly for
    Infrastructure Racks and Rows of Racks.
   When logging on to a local DSView 3 server as an Single Sign-on user
    using “localhost” in the URL, database became inaccessible (unable
    to add/delete units).
   Cascade Switch Overview page did not allow user to change type to an
    AutoView 1x8 switch. A general issue occurred when the user attempts
    to update the cascade switch type from the Add Unit Wizard, Resync
    Wizard, or Cascade Overview page. This caused the number of cascade
    switch ports displayed in the Units View to be shown incorrectly.
   SSH Pass-through sessions were not closing properly when the
    appliance rebooted or the connection between DSView 3 and the
    appliance was dropped.
   Some connection paths other than “KVM” type returned the tools for
    KVM sessions.
   URL encoded report title was mishandling the display of Japanese
    characters in the URL in Internet Explorer 6.
   IBM BladeCenters could only be added to DSR® KVM over IP switches.
    Now they can be added to any KVM type appliance, including AutoView
    switches and MergePoint Unity™ KVM over IP and serial console
    switches.
   Upgrading from DSView 3 software v3.6 to v3.7, and then manually
    adding a blade server would display “Management Module” as missing.
   Duplicated ‘session started’ event log entries for DirectCommand
    sessions were created when a session was launched.
   Username was not provided in the event log entries for MergePoint SP
    Manager sessions.
   Incorrect Japanese characters were displayed for error messages in
    VMware viewer.
   Could not launch DirectCommand session after enabling SSH Pass-
    through.
   Serial Viewer will not launch when client browser uses JRE
    1.6.0.11+.
   PowerManager Units appearing in “Not Responding State”. Receiving
    Critical LCMs Events for PowerManager Units.
   Double byte characters were not saving correctly in Bulk Edit.
   An incorrect message appears when VMware viewer called and DSView 3
    software cannot resolve the ESX IP address from the ESX hostname.
   Incorrect mapping of an ISO image that has any capital letters (e.g.
    Iso or ISO) in the extension occurs and DSView 3 software improperly
    maps this as a Virtual Floppy and it was not functioning properly.
   IBM BladeCenter chassis could not be merged with DSR and AutoView
    switches at the chassis level (fix requires the latest MergePoint SP
    manager plug-ins).
   When an “IBM BladeCenter H” was added and then merged, if the IBM
    BladeCenter was deleted and then rediscovered the merged devices
    would still exist.

				
DOCUMENT INFO