									                                                             Process Instrumentation and Analytics

                   SITRANS FC MASS 2100 - Safety, reliability and
                   quality
Flow Instruments

                    Safe; reliable, low pressure drop

                    No routine maintenance, user friendly

                    High performance, 0.10 % accuracy

                    Single tube design; two welding
                     points only

                    CIP compatible, self-draining

                    Corrosion resistant material




                    SFI chemical presentation.ppt                                  JNG/SFI Page 1
                                                                    Process Instrumentation and Analytics


                   SITRANS FC MASS 2100 sensor DI3 to DI 40

Flow Instruments
                   Specifications
                    Size:                          DI3 (250 kg/h),
                                                    DI6 (1,000 kg/h),
                                                    DI15 (5,600 kg/h),
                                                    DI25 (25,000 kg/h),
                                                    DI40 (52,000 kg/h)
                    Measuring range:               0-52,000 kg/h
                    Version:                       1-pipe system
                    Material (wetted):             1.4435 (AISI316L)
                     (in contact with fluid):       2.4602 (Hastelloy C-22)
                    Liquid pressure:               327 bar (AISI316L)
                                                    430 bar (Hastelloy C-22)
                    Liquid temperature:            -40 to + 180 °C
                    Enclosure material:            1.4301 (AISI316)
                    Ex-version:                    Eex ia IIC T3 – T6
                    Process connections:           Flange DIN 2635, flange ANSI B 16.5
                                                    ISO 2852 Clamp, DIN 11851
                    SFI chemical presentation.ppt                                         JNG/SFI Page 2
                                                    Process Instrumentation and Analytics

                   SITRANS FC MASS 2100 sensor interface
                   – one size fits all
Flow Instruments




                   Uniform sensor interface
                   enables true plug & play

                   Flexibility in operation &
                   maintenance
                    1 sensor for all variants
                    Converters interchangeable
                    SFI chemical presentation.ppt                         JNG/SFI Page 3
                                                                      Process Instrumentation and Analytics


                   SITRANS FC MASS 2100 DI 1.5
Flow Instruments

                   Specifications
                    Size:                          DI 1.5
                    Measuring range:               0-65 kg/h
                    Version:                       1-pipe system
                    Material (wetted):             1.4435 (AISI316)
                     (in contact with fluid):       2.4602 (Hastelloy C-22)
                    Liquid pressure:               296 bar (AISI316)
                                                    460 bar (Hastelloy C-22)
                    Liquid temperature:            -40 to + 180 °C
                    Enclosure material:            1.4301 (AISI316)
                    Ex-version:                    Eex ia IIC T3 – T6
                    Process connections:           G1/4” NPT ANSI B1.20.2
                                                    G1/4” ISO 228-1


                    SFI chemical presentation.ppt                                           JNG/SFI Page 4
                                                                   Process Instrumentation and Analytics

                     SITRANS FC MASS 2100 DI 1.5
                         The reference for mini plants
Flow Instruments

                   Company                         Application
                   Hoechst Technikum               N2 , O2 , Ar, H2 , ethylene
                   BASF, Ludwigshafen              Pharmaceuticals, paints
                   BOSCH                           Gasoline & Diesel test rigs
                   Solvay                          Gases in liquid and gas form
                   Dow Chemicals                   Chemicals
                   Coca Cola                       Dosing of additives
                   Merck                           Pharmaceuticals




                   SFI chemical presentation.ppt                                         JNG/SFI Page 5
                                                                 Process Instrumentation and Analytics

                     SITRANS FC MASS 2100 DI 1.5
                         Typical applications
Flow Instruments

                    Mini plant & Research
                    Fuel injection nozzle & engine testing in the
                     automotive industry
                    Refrigerant charging for hermetic
                     compressors
                    Dosing of flavourings & additives
                     within food & beverage
                    Dosing of essence & fragrances in
                     cosmetic & detergent industry
                    High accuracy gas measurement
                    Dosing of paint
                    Dosing of pills and injectors for pharmaceutical


                    SFI chemical presentation.ppt                                      JNG/SFI Page 6
                                                          Process Instrumentation and Analytics


                   Multiple in-/output functions
Flow Instruments

                   Multiple in-/output functions offer maximum
                   process information and handling

                    3 Current outputs
                    2 Frequency/pulse outputs
                    2 Relay outputs
                    1 Digital input
                    Patented adaptive Batch controller
                    Serial/bus communication for
                     retro-fitting



                    SFI chemical presentation.ppt                               JNG/SFI Page 7
                                                           Process Instrumentation and Analytics


                   Multibus interface – matching all applications
Flow Instruments
                                                    MODBUS RTU

                                 PROFIBUS DP
                                                                          DEVICE NET


                   PROFIBUS PA




                                                                               HART
                                        CAN OPEN


                    SFI chemical presentation.ppt                                JNG/SFI Page 8
                                                            Process Instrumentation and Analytics


                   Multi-parameter flow measurement
Flow Instruments

                               Mass flow rate         [Kg/s]
                               Total mass             [Kg]
                               Density                [Kg/m3]
                               Temperature            [°C]
                               Volumetric flow rate   [l/s]
                               Total volume           [l]
                               Fraction flow          [Kg/s]
                               % Fraction             [%]
                               Total fraction         [Kg]




                   SFI chemical presentation.ppt                                  JNG/SFI Page 9
                                                                    Process Instrumentation and Analytics


                   References within the soap and detergent industry

Flow Instruments




                                      The SITRANS F C MASSFLO® has been the
                                      preferred flow meter for Procter & Gamble
                                      WW since 1988.




                   SFI chemical presentation.ppt                                         JNG/SFI Page 10
                                                                Process Instrumentation and Analytics


                   References within the soap and detergent industry

Flow Instruments

                   Procter & Gamble has systematically replaced weighing cells,
                   dosing pumps and mechanical flow meters by the MASSFLO®
                   meter gaining a competitive advantage

                    Recipes written directly in Kg without conversion errors
                    High production flexibility due to a high dynamic measuring range
                    Fast change of recipes
                    No recalibration needed
                    Maintenance reduced to an absolute minimum
                    Continuously batch process possible
                    Batch parameters and monitoring automated via multibus interface
                    DI1.5 has increased the accuracy on dosing of additives
                    Density is directly proportional to process quality


                    SFI chemical presentation.ppt                                    JNG/SFI Page 11
                                                                       Process Instrumentation and Analytics


                   SITRANS F M MAGFLO, MAG 1100

Flow Instruments

                   Specifications
                    Size:                          DN 6 - 10
                    Connection                     Flangless ( sandwich design )
                    Liner material                 Ceramics
                                                    PFA
                    Electrodes                     Platinum
                                                    Hastelloy C276
                    Liquid pressure                40 bar
                    Liquid temperature:            -20 to + 200 °C
                    Enclosure material:            1.4301 (AISI316)
                    Enclosure rating               IP67
                    Ex-version:                    Eex [ia/ib] IIB T4 – T6




                    SFI chemical presentation.ppt                                           JNG/SFI Page 12
                                                                      Process Instrumentation and Analytics


                   SITRANS F M MAGFLO, MAG 3100

Flow Instruments


                            Specifications
                            Accuracy               0.25%
                            Size [mm]              DN 25-1200
                            Connection             Flange
                            Pressure [Bar]         Max. 40 Bar
                            Temperature [°C]       -5 to 90 C
                            Enclosure              IP67/68
                            Liner:                 Composite Elastomer Hard Rubber (Ebonite) ;
                            Electrodes             AISI 316 Ti
                            Application            Drinking Water & Waste Water
                            Approval:              WRC approved
                                                   OMIL R 49




                   SFI chemical presentation.ppt                                           JNG/SFI Page 13
                                                                        Process Instrumentation and Analytics


                   SITRANS FM MAG3100

Flow Instruments       Specifications
                       Accuracy                    0.25%
                       Size [mm]                   DN 15 – 2000
                       Connection                  Flange
                       Pressure [Bar]              Max. 100 Bar
                       Temperature [°C]            -40 to 180 C
                       Enclosure                   IP67/68
                       Liner:                      Neoprene; Ebonite; EPDM; PTFE; Linatex; ..
                       Electrodes:                 AISI 316Ti; Hastelloy; Titanium; Platinum…
                       Ex-version                  EEx




                   SFI chemical presentation.ppt                                             JNG/SFI Page 14
                                                               Process Instrumentation and Analytics


                   In situ verification - optimum cost of operation
Flow Instruments




                    Fully automated flow meter test in 15 minutes
                    • Signal converter test - flow simulation
                    • Flowmeter insulation test - cross-talk test
                    • Sensor magnetism test - boost test


                   SFI chemical presentation.ppt                                    JNG/SFI Page 15

								