Troubleshooting

Workbook







Purpose

You will know how to use a troubleshooting model for common drop-related problems.

This will decrease the amount of time spent on drop-related service calls and increase

customer satisfaction.



Objectives

At the end of this module, you will be able to:

 Use a four-step troubleshooting model to identify and repair common

drop-related problems.

 Demonstrate troubleshooting proficiency by using the bypass technique and

the “divide-and-conquer“ method.

Standard Troubleshooting Model

Troubleshooting is a four-step process designed to assist field technicians. By following

this simple model, you will be able to more quickly resolve problems with cable service.



Let’s take a look at this model in detail and then apply it to some common

cable-related problems.



Step 1: Analyze the problem

The first step in analyzing the problem is to get the customer’s description of it. The

technician should question the customer and listen closely to the responses.



It is very useful to ask questions like:

 What is the problem?

 How many TVs are affected?

 Which channels are affected?

 What time of day does the problem occur?

 How often does it occur?



Step 2: Isolate the problem

Isolating the problem is a process of elimination, in which the technician determines

which parts of the cable are in good working order. There are two approaches.



 The “divide-and-conquer” method systematically “cuts the problem in half” by

strategically checking at various points in the system.

 For example, if there is a low signal problem, you might start by checking

the signal level at the wall plate.

 If it is bad, you could then go to a point halfway between the wall plate and

the tap, and check the signal level there.

 If the signal level at the ground block is good, you would check next at a

point between the ground block and the wall plate.



 Another method is the bypass method.

 With this method, you attach a length of drop cable known to be good,

bypassing devices and sections of cable that are suspected of being

defective.

 If this eliminates the problem, the suspicions are confirmed.

Step 3: Fix the problem

Fixing the problem simply consists of taking the steps needed to repair the cause of the

problem.



Make sure that the fix is adequate to make a second service call unnecessary.



Step 4: Verify the fix

This step is critical to successful customer service. It is crucial that we check back with

the customer and visually check the TVs and channels that were being affected by the

problem.

 Make sure there are not two separate problems that need to be fixed.

 Check signal levels.

 Check for signal leakage.

Common Problems and Isolation Techniques



The following pages present approaches to troubleshooting each of the most common

drop-related problems—ghosting and double images, bad or shorted cables, hum

modulation, and lines.

Ghosting and Double Images

Understand that ghosting and double imaging are not the same thing. A ghost refers to

two images coming from the same video signal, one image is fainter than the other. A

double image comes from two different video signals sharing the same frequency. The

troubleshooting procedure is the same in either case, however.



Step 1: Analyze the problem

 Learn from the customer.

 Check to see if the ghost is on more than one TV.

 Look at the picture on all channels.



Step 2: Isolate the problem

The technician should use one or more of the following methods to help isolate

the problem:

1. Look for loose connectors, examine all jumpers, and check the integrity of the

drop cable. If that doesn’t isolate the problem, try one of the following:

 Run a temporary drop from the tap to the input of the ground block to

determine if the ghosting is in the drop or the main line.

 With one end of the drop hooked up to the tap, and the other to the SLM,

tune the SLM to a local channel. Any garbled audio on a local channel

indicates ingress on the drop.

 Using the SLM, measure a local signal on the disconnected, terminated

drop. There should be no signal. If signal is present, it is from ingress.



Step 3: Fix the problem

 Replace inferior VCR jumpers with quality jumpers.

 Do not over-tighten the connectors. This will damage internal solder joints.

Step 4: Verify the fix

 After making a repair, be sure to check all channels and TVs.

 Check signal levels.

 Check for signal leakage.

 Check back with the customer.

Bad or Shorted Cables

If you suspect that an underground drop is defective, you will want to use the following

method for evaluating the condition of the drop cable. This method will determine

whether a shorted condition is causing the problem.



Step 1: Analyze the problem

 Learn from the customer.

 Look at the picture on all channels.

 Check all TVs that are connected to cable.



Step 2: Isolate the problem

Use this method when there is reason to suspect that an underground drop is defective.

1. Measure the resistance of a terminator.

2. Record this measurement.

3. Terminate one end of the drop.

4. Estimate the length of the drop.

5. Go to the other end and measure the resistance from the shield to the center

conductor. Record this measurement.

6. Subtract the cable resistance from the terminator resistance, and record the

difference.

7. Divide this value by the resistance per foot—usually 0.0579 /ft. for RG-59,

0.0379 /ft. for RG-6.

8. Subtract the cable resistance from the terminator resistance, and record the

difference.

9. Divide this value by the resistance per foot—usually 0.0579 /ft. for RG-59,

0.0379 /ft. for RG-6.

 If the value derived equals the estimated length of the drop, the drop cable

is in good condition.

 If the value derived is significantly shorter than the estimated length of the

drop, the drop has a bad spot.



For example, suppose you have:

 RG-6 drop, 100 ft. long

 Terminator resistance of 75 

 Cable resistance of 77 



Then, you would calculate:

 77 minus 75 equals 2 

 2  divided by .0397 = 50.37 ft.

The problem, therefore, is at about half the distance of the length of the drop—50 ft.

Note: The distance this calculation yields is measured from the

non-terminated end of the drop.



Step 3: Fix the problem

 Replace any bad cables and connectors found.



Step 4: Verify the fix

 After making the repair, check all channels.

 Look at the pictures on all the customer’s TVs.

 Check the signal levels.

 Use a leakage detector.

 Check back with the customer.

Hands-On Activity: Calculating Length from Resistance

in the Drop Cable Loop



Calculate the length of the drop cable issued to you by following the steps below:



1. Measure the resistance of a terminator.



2. Record this measurement.



3. Terminate one end of the drop.



4. Estimate the length of the drop.



5. At the opposite end of the drop, measure the resistance from the shield to the

center conductor.



6. Record this measurement.



7. Subtract the cable resistance from the terminator resistance, and record this

value.



8. Divide this value by the resistance per foot—typically 0.0579 /ft. for RG-59,

0.0379 /ft. for RG-6.

a) If the value derived equals the estimated distance of the drop, the drop cable is in

good condition.

b) If the value derived is a distance significantly shorter than the estimated length of

the drop, there is a bad spot in the drop, at the length derived.

Hum Modulation

Hum bars are most generally caused by an improper ground. Water-damaged drop

splitters on tap spigots have been known to cause hum bars.



When you suspect a hum modulation problem, follow these procedures:



Step 1: Analyze the problem

 Learn from the customer.

 Look at the picture on all channels.

 Look at the picture on all TVs connected to cable.



Step 2: Isolate the problem

Use one or more of these methods to help isolate the problem:

 Check all cables and connectors.

 Temporarily disconnect the ground from the ground block to see if this clears

up the problem.

 Disconnect all other customers’ drops from the tap to eliminate the possibility

of backfeed.

 Use the bypass method to determine whether the hum bar is caused by a

house amplifier, converter, or other customer equipment.



Step 3: Fix the problem

 Replace any splitters, connectors, cable, or other faulty equipment causing

the hum bar.

 Note: Do not replace any part of a defective ground or defective TV parts.



Step 4: Verify the fix

 After making the repair, check all channels and TVs.

 Check the signal strength.

 Use a signal leakage detector.

 Check back with the customer.

Lines

Step 1: Analyze the problem

 Learn from the customer.

 Look at the picture on all channels.

 Look at all TVs connected to cable.



Step 2: Isolate the problem

 Check the signal level at the wall plate.

 A reading of 15 dBmV or above at the wall plate indicates that a house

amplifier is misadjusted or a drop is hooked up to a tap with high outputs.

 Make sure that the input to the house amplifier, if there is one, is no higher

than the recommended input level, usually 0 dBmV.

 If equipment is suspected of causing the problem, use the bypass method.

 With a test set, check at various points in the drop system, using the

divide-and-conquer process.

 Inspect all cables and connectors.



Step 3: Fix the problem

 Replace any cables, connectors, or equipment found to be defective.



Step 4: Verify the fix

 Check signal levels.

 Use a leakage detector.

 Look at the picture on all channels.

 Check back with the customer.

9.


Related docs
Other docs by HC120217042156
PROCLAMATION OF SALE
Views: 1  |  Downloads: 0
Unit 6 Two Bad Ants
Views: 0  |  Downloads: 0
TANGKAPAN, GELEDAH PENGGUNAAN GARI
Views: 0  |  Downloads: 0
World War II Test Review
Views: 3  |  Downloads: 0
COPPER CANYON MUSHROOM TOUR
Views: 0  |  Downloads: 0
Systematic and Unsystematic Risk
Views: 0  |  Downloads: 0
The Patriots Point Of View
Views: 0  |  Downloads: 0
Son los abuelos tuyos
Views: 0  |  Downloads: 0
phrc 2011 regional thesaurus
Views: 0  |  Downloads: 0
By registering with docstoc.com you agree to our
privacy policy

You are almost ready to download!

You are almost ready to download!