Norstar PRI-T1 Settings.
Ordering specs
Signal = ESF
Protocol = National
Line Code = B8ZS
Timing = Central Office
Outpost digits =3
3rd digit can't be a 9 or an 8
i.e. 533-5800 or 533-5900
if it is, you must go with 4
digit outpost using same rule.
Installing Cards
Install T1 card in slot #4
Install Combo card in slot 2
Programming
Obtain system ID no.
1. Feature ** 79743
2. Press show
3. Copy system ID no.
4. Exit
Enable PRI by calling 1800/ 466-7835 (800/4nortel)
1. Option 1
2. Express routing code1599#
3. Enter Authorization Number
at top of sheet and follow
instructions. OR 919/905-9570
Enter code in KSU programming
1. Software keys- Show
2. Next
3. Password Keys - show
4. Enter PRI code
5. Back up to maintenance.
Maintenance-show
Next
Mod Status-show
List
Next
KSU-card 1
State
Disable
Backup to hardware
Hardware-show
List
Cards on KSU-show
Change-PRI (or T1)
Backup to Maintenance
Follow steps above and
Enable card
Top light should be solid amber & light no. 5 (last light) should be solid green.
After T1 is fully operational only last light should be solid green.
Lines-show
L001
PRI (Set for E&M for T1 w/o PRI)
Line Type: PRI-A (Pool A for T1)
(Repeat setting for lines
1-23)
System Programming-show
Access codes-next
Line Pool Codes-show
Line Pool A: none
External code: Clear to “None”
(Delete 9 from all line pool codes)
Services-show
Next
Routing services
Route:001-show
Next
Use: PRI-A
Backup to Routes-next
Dest Codes-show
Add
Code 9-show
(If you can't add 9, it is
Being used somewhere else.
You must find it and clear it)
Change to 001-next
(Change all to 001)
Maintenance-show
Link Stat
Cards on KSU-show
Card: 1
B channel-show
PRI: B01 Idle-next B02
Idle - next B03 Idle ....
(For fractional T1's
"Disable" B channels not
being used. They should
read "B17 Near")
Terminals & Sets
Line Access
Line Pool Access
PRI-A:Y
Heading-next
Prime Line to I/C
Line programming
6.0 and above Line 157
6.0 and below Line 145