							                                      Fuses & Plug-in Horsepower Resistor®
                                   Cross Reference Chart by Speed Control Model

                   Model                         Line Fuse                Armature or                    Plug-in
                                                                          Motor Fuse                   Horsepower
                                                                                                        Resistor®
         KBIC All Models                          Optional                   Optional                    Required
         KBMM All Models                         Available                  Available                    Required
         KBWD All Models                          External                   External                    Required
         KBWS All Models                          Optional                   Optional                    Required
         KBCC Non -R Models                       Included                  Available                    Required
         KBCC-255                                 External                   Included                 Not Required*
         KBCC-240D                                External                   Included                  Not Required
         KBWT All Models                          External                  Available                 Not Required*
         KBCC -R Models                           Included                  Available                    Required
         KBPB All Models                          Included                  Available                    Required
         KBMG-212D                                External                   External                  Not Required
         KBRG-240D/-225D                          Included                   Included                  Not Required
         KBRG-255                                 External                   External                  Not Required
         KBWM All Models                          Included                  Available                    Required
         KBMD All Models                          Included                  Available                    Required
         KBPC-240D                                External                   Included                  Not Required
         KBPC-225                                 External                   External                  Not Required
         KBPW-240D                                External                   External                  Not Required
         KBRC-240D                                External                   External                  Not Required
         KBVF All Models                          External               Not Required**                Not Required
         KBAC All Models                          External               Not Required**                Not Required

- Optional: Optional fuse mounting kit can be added.
- Available: Provisions for mounting the fuse are provided, but the fuse is not included with the control.
  Consult the Fuse Selection Chart for proper fuse sizing.
- Included: Fuse is included with the control. The armature fuse may have to be changed if the control is to be used with
  a smaller motor. Consult the Fuse Selection Chart for proper fuse sizing.
- External: There are no provisions for mounting the fuse on the control. However, we recommend that the customer
  provide an external means of fusing the control. Consult the Fuse Selection Chart for proper fuse sizing.
- Required: The control must have a Plug-in Horsepower Resistor® installed, correctly sized by motor horsepower.
  Consult the Plug-in Horsepower Resistor® Selection Chart for proper sizing.
- Not Required: This control uses Quick Jumps instead for current selection. *These models have fixed current selection,
  and use the CL trimpot for current adjustment. **These models have I 2t Electronic Overload Protection, so do not need
  fusing in the motor leads.

						
Related docs
Other docs by HC120212071449
SPECIFICATION SECTION [16260] FOR
Views: 2  |  Downloads: 0
Trigonometry Final Exam Review Sheet
Views: 18  |  Downloads: 0
FORMS/NCMC Membership form 201112.doc
Views: 1  |  Downloads: 0
3470261 md programa de ex
Views: 5  |  Downloads: 0
Department of Veterans Affairs
Views: 5  |  Downloads: 0
18 2 measuring motor stall current
Views: 6  |  Downloads: 0
San Angelo Foundry
Views: 13  |  Downloads: 0
Appendix D � Disposition Codes
Views: 136  |  Downloads: 0