Docstoc

TECHNICAL INFORMATION

Document Sample
TECHNICAL INFORMATION Powered By Docstoc
					  TECHNICAL
INFORMATION
                             CAPITOL THEATRE
                          TECHNICAL INFORMATION

                                   TABLE OF CONTENTS

GENERAL INFORMATION
   •   Risk Management                                                    2
   •   Accommodations                                                     2
   •   Auditorium Seating                                                 3
   •   Stalls Seating Plan                                                4
   •   Dress Circle Seating Plan                                          5
   •   Rehearsal Room                                                     6
   •   Dressing Rooms                                                     7

STAGE SPECIFICATIONS
   •   Stage Dimensions                                              _____ 8
   •   Orchestra Pit                                         _____         8
   •   Flying System                                                 _     9
   •   Electric Winches                                              _     9
   •   Fly System Specifications                                       10-12
   •   House Curtain                                                      13
   •   Stage Access                                                       13
   •   Service Lift                                                       13

LIGHTING SPECIFICATIONS
   •   Mains/Power Distribution                                         14-18
   •   Stage Lighting Positions                                      _____18
   •   Data Specifications                                                 19
   •   Cable Runs                                                          20
   •   Patching                                                            21
   •   Rigging                                                             22
   •   Equipment                                                           22

AUDIO/PAGING SPECIFICATIONS                                  _____        23
STAGE MANAGER’S CONSOLE                                      ____ _        23
OUTSIDE BROADCAST PANEL                                                    23
HEARING AID LOOP                                                        24-25
EXTERIOR POSTER BOXES                                                      26
ALL INQUIRIES                                                              26



PLEASE NOTE: All data shown in this document is current as at September 2010 but is
subject to verification and review at any time by Capitol Theatre Management Pty Ltd.



                                                                                  -1-
GENERAL INFORMATION

RISK MANAGEMENT

Equipment brought into the Capitol Theatre is subject to safety checks by Capitol Theatre
staff.

All Mains-connected electrical equipment requires an attached current inspection tag from a
licensed electrician.

Lighting equipment rigged overhead must be secured with a safety chain or equivalent.

Overhead equipment (including scenery) must be rigged by a qualified rigger, using
appropriately certified equipment.

Scenery and large props must be of a fire retardant fabric or treated with a fire retardant. A
certificate of such treatment must be produced on request.

In accordance with NSW Occupational Health & Safety (OH&S) legislation, a Risk
Assessment is required during pre-production for all events.

ACCOMMODATIONS

Technical Rooms and Dressing Rooms, ranging from Star Suites to Chorus Rooms, begin at
sub-stage level and extend over 6 floors, including: Wardrobe, Theatre Management Offices,
Green Room with Kitchen and Rehearsal Room. All rooms have air conditioning and some
have natural light.




                                                                                             -2-
AUDITORIUM SEATING

THE THEATRE HAS SEVERAL MODES AVAILABLE.

OPTIONS INCLUDE A MOVEABLE WALL AND MOVEABLE CURTAIN IN THE DRESS
CIRCLE.




                     MAXIMUM THEATRE SEATING CONFIGURATION



                           Stalls
            Stalls       Wheelchair       Dress Circle     Balcony Boxes          Total
                          Seating

            1036                10           1032                  16             2094




             TYPICAL MUSICAL THEATRE SEATING CONFIGURATION

                      (With small Orchestra Pit & a Sound Mixing Desk)



                                       Stalls
Orchestra Size         Stalls        Wheelchair     Dress Circle        Balcony Boxes     Total
                                      Seating

     30+               980              10               1032                16           2038




  For additional Orchestra Pitt sizes, see under Staging Specifications in this document.




                                                                                              -3-
STALLS SEATING PLAN




                      -4-
DRESS CIRCLE SEATING PLAN




                            -5-
REHEARSAL ROOM
The Rehearsal Room is located on the 3rd level of the Capitol Theatre.

Access is via Stage Door which is located on the corner of Pitt and Hay Streets, Haymarket.

Access to Rehearsal Room via Theatre Goods Lift – 2.4m x 2.7m.

Piano available.

SIZE
15.2m wide x 15.4m deep

FACILITIES
Semi sprung floor
Mirrors on one wall
Trestle table and chairs
Permanently installed Ballet Bars on 3 walls
Male and female change rooms adjacent to Rehearsal Room
Upright piano – tuning has an additional cost of approximately $130.00 if requested
Green Room (Level 2) with tea and coffee making facilities / vending machines
Open air balcony with barbecue facilities

Please Note: CD player is not provided by the Theatre.

RATES
Rates are available on application.

Please note that rehearsal room use is not included in standard venue rental.




                                                                                        -6-
DRESSING ROOMS
All Dressing Rooms have toilet, shower and hand basins, some rooms have share facilities.

SUB-STAGE LEVEL

34 Male Chorus
28 Female Chorus
Crew Room
Male and Female Orchestra Change Rooms and kitchenette
2 x 3 Person Rooms
3 x 2 Person Rooms
Conductor Suite with a piano

STAGE LEVEL

8 Person Room or Star Suite
2 x 3 Person Room or Star Suite (share facilities)
4 Person Room or Star Suite

1st FLOOR

Visiting Company Office
2 x 4 Person Room (share facilities)

2nd FLOOR

Green Room with Kitchen
Wardrobe Room (incl. Laundry 2 x Washers and Dryers) with Office and Wig Room




                                                                                       -7-
STAGE SPECIFICATIONS

STAGE DIMENSIONS

PROSCENIUM
Height at Centre                                 8.6m
Height at Curved Corners                         7.3m
Width                                            15.2m

STAGE DEPTH
Proscenium Wall to Crossover                     15.8m
Proscenium Wall to Rear Wall PS                  17.1m
Proscenium Wall to Rear Wall OP                          16.6m
Column on OP                                     15.6m
Fixed Forestage Forward of Proscenium            0.2m
Forestage Extension Available                    3.4m

STAGE HEIGHTS
Underside of Grid                                23.15m
Underside of Fly Galleries & OP Ceiling          9m
Stage to Orchestra Pit Floor                     2.25m

WINGS
PS Proscenium Arch to Fly Rail                   7.2m
OP Proscenium to Side Wall                       14m
Between Fly Galleries                            24.4m

STAGE SURFACE
Demountable semi sprung timber floor 19.4m Wide x 15.7m Deep from Proscenium Wall

ORCHESTRA PIT

3 Configurations by demountable Platforms.

   • 30 piece – 3.4m at centre, 2.3m PS & OP x 15.2m Wide
   • 76 piece – 5.4m at centre, 4.2m PS & OP x 21.8m Wide
   • 110 piece – 6.4m at centre, 5.3m PS & OP x 21.8m Wide

There is no Orchestra lift, a Demountable Rostrum System is available to fill pit at either
stage level or auditorium floor level.




                                                                                              -8-
FLYING SYSTEM

SINGLE PURCHASE COUNTERWEIGHT SYSTEM, PLUS 4 FIXED SPEED
WINCHES.

Cross Stage Fly Bars             100 (Winches on Lines 6 & 100)
Batten Length              19m
Batten Material            RHS 50mm x 75mm
Load Capacity              500kg
Batten Drift               22580mm
Pick-ups per Bar           6
Pick-up Centres            3400mm
Cradle Extensions          20
Extenders Load Capacity    250kg
Batten Extenders           1m each end
Panorama Bars              4
Panorama Batten Length     14m
Panorama Batten Material   48mm OD Gal. pipe
Panorama Load Capacity     500kg

ELECTRIC WINCHES

PS Panorama Bar            1    Onstage Panorama Bar
OP Panorama Bar            1    Onstage Panorama Bar
Line 6                     1
Line 100                   1
Load Capacity              1000kg
Batten Length              14m
Batten Material            RHS 50mm x 75mm




                                                                  -9-
FLY SYSTEM SPECIFICATIONS
FLY LINES

LINE# DISTANCE FROM PROSCENIUM       NOTES

    1         0.500mm
    2         0.650 H/C
    3         0.800mm
    4         0.925mm
    5         1.075mm
    6         1.200mm     W1 Winch
    7         1.350mm
    8         1.500mm
    9         1.650mm
    10        1.800mm
    11        1.950mm
    12        2.100mm
    13        2.250mm
    14        2.400mm
    15        2.550mm
    16        2.700mm
    17        2.850mm
    18        3.000mm
    19        3.150mm
    20        3.300mm
    21        3.450mm
    22        3.600mm
    23        3.750mm
    24        3.900mm
    25        4.050mm
    26        4.200mm
    27        4.350mm
    28        4.500mm
    29        4.650mm
    30        4.800mm
    31        4.950mm
    32        5.100mm
    33        5.250mm
    34        5.400mm
    35        5.550mm
    36        5.700mm
    37        5.850mm




                                             - 10 -
FLY SYSTEM SPECIFICATIONS
FLY LINES

LINE# DISTANCE FROM PROSCENIUM   NOTES

    38        6.000mm
    39        6.150mm
    40        6.300mm
    41        6.500mm
    42        6.700mm
    43        6.850mm
    44        7.000mm
    45        7.150mm
    46        7.300mm
    47        7.450mm
    48        7.600mm
    49        7.750mm
    50        7.900mm
    51        8.050mm
    52        8.200mm
    53        8.350mm
    54        8.500mm
    55        8.700mm
    56        8.850mm
    57        9.000mm
    58        9.150mm
    59        9.300mm
    60        9.450mm
    61        9.600mm
    62        9.750mm
    63        9.900mm
    64        10.050mm
    65        10.200mm
    66        10.350mm
    67        10.500mm
    68        10.650mm
    69        10.800mm
    70        10.950mm
    71        11.100mm
    72        11.250mm
    73        11.400mm
    74        11.550mm
    75        11.700mm
    76        11.850mm
    77        12.000mm




                                         - 11 -
FLY SYSTEM SPECIFICATIONS
FLY LINES

LINE# DISTANCE FROM PROSCENIUM      NOTES

    78        12.150mm
    79        12.300mm
    80        12.450mm
    81        12.600mm
    82        12.750mm
    83        12.900mm
    84        13.050mm
    85        13.200mm
    86        13.350mm
    87        13.500mm
    88        13.650mm
    89        13.800mm
    90        13.950mm
    91        N/A
    92        14.250mm
    93        14.400mm
    94        14.550mm
    95        14.700mm
    96        N/A
    97        15.000mm
    98        15.150mm
    99        15.300mm
    100       15.450mm
    101       15.600mm   W3 Winch




                                            - 12 -
HOUSE CURTAIN

The House Curtain is in two halves being blue velvet with gold trim. Its measurements are
20,800mm Wide x 10,500mm Drop, with 800mm overlap and sewn with 80% fullness.
Outside edges 40mm.

There is a pelmet hung separately to the house curtain.

The venue has a number of boarders, legs, tabs and side masks which can be made
available at a competitive industry rate.



STAGE ACCESS

Via a truck lift (travel approx. 1,500mm) down to stage level in Upstage OP corner with end
access only. It can take truck tray no longer than 41ft. down to stage level if required.

Truck lift also has the ability to stop at service level which allows truck to unload straight onto
truck lift at street level under an awning.

At this level the truck lift has a side exit which gives access to Service Lift on ground floor
which is good for taking equipment to FOH and the auditorium. Side exit size? m Wide x? m
High

Lift platform size 13.4m Long x 3.4m wide, end on access. (Note: A 45ft Trailer does not fit)

Street level door is 3.3m Wide x 5m High.
It has a weight restriction of 25,000kg



SERVICE LIFT

A lift to most backstage levels has been provided with approximately internal dimensions of
2.4m x 2.7m with a weight restriction of 2,000kg.




                                                                                               - 13 -
LIGHTING SPECIFICATIONS

MAINS / POWER DISTRIBUTION

FRONT-OF-HOUSE

BRIDGE 1
  • 6 x 40Amp 5pin WILCO 3Phase Outlets at centre of the Bridge
  • 10 x 10Amp Single Phase Double GPO’s spread evenly across Bridge
  •   4 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

BRIDGE 2
  • 6 x 40Amp 5pin WILCO 3Phase Outlets at centre of the Bridge
  • 10 x 10Amp Single Phase Double GPO’s spread evenly across Bridge
  •   4 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

BRIDGE 3
  • 4 x 40Amp 5pin WILCO 3Phase Outlets at centre of the Bridge
  • 10 x 10Amp Single Phase Double GPO’s spread evenly across Bridge
  •   2 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

BOX BOOMS

PROMPT
  •   9 x 40 Amp 5pin WILCO 3 Phase Outlets

OPPOSITE PROMPT
  •   9 x 40 Amp 5pin WILCO 3 Phase Outlets
  •   5 x 10 Amp Single Phase Double GPO’s
  •   3 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)




                                                                        - 14 -
FLY FLOORS

PROMPT

 Fly Floor 1
  •   5 x 10 Amp Single Phase Double GPO’s
  •   2 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

 Fly Floor 2
  •   8 x 40 Amp 5pin WILCO 3 Phase Outlets
  •   5 x 10 Amp Single Phase Double GPO’s
  •   2 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

 Loading Gallery
  •   2 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

OPPOSITE PROMPT

 Fly Floor 1
  •   5 x 10 Amp Single Phase Double GPO’s
  •   2 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

 Fly Floor 2
  •   16 x 40 Amp 5pin WILCO 3 Phase Outlets
  •   5 x 10 Amp Single Phase Double GPO’s
  •   2 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

 Winching Gallery
  •   No Power

FLY CROSSOVER GALLERIES

Fly Floor 1 Crossover
   • 8 x 10 Amp Single Phase Double GPO’s
Fly Floor 2 Crossover
   • 8 x 10 Amp Single Phase Double GPO’s




                                                                        - 15 -
STAGE

DOWNSTAGE PROMPT
  •   3 x 10 Amp Single Phase Double GPO’s
  •   1 x 10 Amp Single Phase Single GPO
  •   3 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

UPSTAGE PROMPT
  •   2 x 40 Amp 5pin WILCO 3 Phase Outlets
  •   3 x 10 Amp Single Phase Double GPO’s
  •   2 x 10 Amp Single Phase Single GPO’s
  •   3 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

DOWNSTAGE OPPOSITE PROMPT
  •   1 x 315 Amp Mains
  •   2 x 40 Amp 5pin WILCO 3 Phase Outlets
  •   2 x 10 Amp Single Phase Double GPO’s
  •   2 x 10 Amp Single Phase Single GPO’s
  •   3 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

UPSTAGE OPPOSITE PROMPT
  •   2 x 40 Amp 5pin WILCO 3 Phase Outlets
  •   3 x 10 Amp Single Phase Double GPO’s
  •   2 x 10 Amp Single Phase Single GPO’s
  •   3 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

GRID

UPSTAGE PROMPT
  •   1 x 10 Amp Single Phase Double GPO
  •   1 x 10 Amp Single Phase Double GPO (Separate Earth for Sound)

UPSTAGE OPPOSITE PROMPT
  •   1 x 10 Amp Single Phase Double GPO
  •   1 x 10 Amp Single Phase Double GPO (Separate Earth for Sound)

DOWNSTAGE (Spread across Proscenium Wall)
  •   12 x 40 Amp 5pin WILCO 3 Phase Outlets
  •   9 x 10 Amp Single Phase Double GPO’s
  •   4 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)




                                                                        - 16 -
SUB-STAGE

DOWNSTAGE PROMPT
  •   2 x 40 Amp 5pin WILCO 3 Phase Outlets
  •   4 x 10 Amp Single Phase Double GPO’s
  •   1 x 10 Amp Single Phase Single GPO
  •   2 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

UPSTAGE PROMPT
  •   1 x 315 Amp Mains
  •   4 x 40 Amp 5pin WILCO 3 Phase Outlets
  •   4 x 10 Amp Single Phase Double GPO’s
  •   1 x 10 Amp Single Phase Single GPO
  •   2 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

DOWNSTAGE OPPOSITE PROMPT
  •   2 x 40 Amp 5pin WILCO 3 Phase Outlets
  •   4 x 10 Amp Single Phase Double GPO’s
  •   1 x 10 Amp Single Phase Single GPO
  •   2 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

UPSTAGE OPPOSITE PROMPT
  •   2 x 40 Amp 5pin WILCO 3 Phase Outlets
  •   4 x 10 Amp Single Phase Double GPO’s
  •   1 x 10 Amp Single Phase Single GPO
  •   2 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

REHEARSAL ROOM

  •   1 x 150 Amp Mains
  •   2 x 40 Amp 5pin WILCO 3 Phase Outlets
  •   3 x 10 Amp Single Phase Double GPO’s
  •   2 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

LIGHTING CONTROL BOOTH (& Follow Spot Booth)

  •   4 x 40 Amp 5pin WILCO 3 Phase Outlets
  •   5 x 20 Amp Single Phase Single GPO’s
  •   3 x 10 Amp Single Phase Double GPO’s
  •   3 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)




                                                                        - 17 -
SOUND BOOTH

  •   3 x 40 Amp 5pin WILCO 3 Phase Outlets (1 x Shares Feed to Auditorium Production
      Trap)
  •   4 x 10 Amp Single Phase Double GPO’s
  •   4 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

AUDITORIUM PRODUCTION TRAP

  •   1 x 40 Amp 5pin WILCO 3 Phase Outlet (Fed from Sound Booth)
  •   1 x 10 Amp Single Phase Double GPO
  •   2 x 10 Amp Single Phase Double GPO’s (Separate Earth for Sound)

STAGE LIGHTING POSITIONS
(ALL MEASUREMENTS TAKEN FROM PROSCENIUM ARCH)


FRONT-OF-HOUSE

  •   BRIDGE 1                       10m
  •   BRIDGE 2                       18.5m
  •   BRIDGE 3                       27.8m

BOX BOOMS

The current box boom positions are being revised – please contact CTM
management regarding current configuration.

CIRCLE FRONT                         16m

HERITAGE BOOMS                       16m

FOLLOW SPOT ROOM                     39m




                                                                                  - 18 -
DATA SPECIFICATIONS

DATA OUTLETS / RUNS

  •   Three streams of 5 Pin D
  •   MX 512 in a series circuit throughout Theatre.
  •   Data patch panel and splitter amplifiers are located at rear of auditorium (Sound
      Booth)

DATA OUTLETS LOCATED AT:-

  •   FOH Bridges 1,2 & 3 (At Centre of Bridge Patch Bays)
  •   Circle Front (Prompt & Opposite Prompt Ends)
  •   Heritage Boom 1 (Prompt & Opposite Prompt)
  •   Box Booms (Prompt & Opposite Prompt)
  •   Stage ( Prompt US, Opposite Prompt DS & US)
  •   Fly Floor 1 & 2 (DS Prompt & Opposite Prompt)
  •   Fly Floor 1 US Crossover
  •   Grid (Prompt US & DS, Opposite Prompt US & DS)
  •   Auditorium / Production Trap
  •   Basement (Prompt US & DS, Opposite Prompt US & DS)
  •   Follow spot / Control Booth
  •   Rehearsal Room
  •   Outside Broadcast Panel

DATA CONTROL POINTS LOCATED AT:-

  •   Follow spot / Control Room
  •   Rehearsal Point / Auditorium Production Trap
  •   Prompt Corner
  •   Opposite Prompt Corner
  •   Outside Broadcast Panel




                                                                                          - 19 -
CABLE RUNS

LENGTH OF CABLE RUNS

PROMPT

  •   Fly Floor 1 – Prompt End of Head Batten       - 12 metres

  •   Fly Floor 2 – Prompt End of Head Batten       - 15.5 metres

  •   Loading Gallery – Prompt End of Head Batten   - 22 metres

  •   Fly Floor 1 – Box Boom                        - 10 metres

  •   Box Booms - Box Boom Dimmers                  - 15 metres

OPPOSITE PROMPT

  •   Fly Floor 1 –OP End of Head Batten            - 12 metres

  •   Fly Floor 2 – OP End of Head Batten           - 15.5 metres

  •   Winching Gallery – OP End of Head Batten      - 20.5 metres

  •   Fly Floor 1 – Box Boom                        - 15 metres

  •   Box Booms - Box Boom Dimmers                  - 10 metres




                                                                    - 20 -
PATCHING

FRONT OF HOUSE BRIDGES

BRIDGE 1
  •   Patch Panel Located at centre of Bridge
  •   20 x 10 Amp outlets spread evenly across Bridge 1
  •   20 x 20 Amp outlets spread evenly across Bridge 1

BRIDGE 2
  •   Patch Panel Located at centre of Bridge
  •   20 x 10 Amp outlets spread evenly across Bridge 2
  •   20 x 20 Amp outlets spread evenly across Bridge 2

BRIDGE 3
  •   Patch Panel Located at centre of Bridge
  •   15 x 10 Amp outlets spread evenly across Bridge 3
  •   15 x 20 Amp outlets spread evenly across Bridge 3

CIRCLE FRONT

PROMPT - CENTRE
  •   10 x 10 Amp outlets spread evenly
  •   10 x 20 Amp outlets spread evenly
  •   Fed to Box Boom on PS

OPPOSITE PROMPT - CENTRE
  •   10 x 10 Amp outlets spread evenly
  •   10 x 20 Amp outlets spread evenly
  •   Fed to Box Boom on OP




                                                          - 21 -
RIGGING

OVERHEAD LIGHTING SPOT BARS

  •   24 x 4.5m Underhung Lighting Spot Bars
  •   Each Bar consists of 12 x 10Amp outlets
  •   Over head bars consist of four Bars butted together
  •   In House Looms to reach each Lighting Bar From Fly Floor 2
  •   Standard 48mmOD pipe under for Hanging Lights


BOX BOOMS

  •   In House rigging for Box Booms may be changed to suit Production

EQUIPMENT

DIMMERS

BOOM BASES

  •   10 x Boom Bases




                                                                         - 22 -
AUDIO / PAGING SPECIFICATIONS
Basic block cabling from technical rack patch field rear of stalls to 52 loudspeaker points
And 173 audio/MIC tie line points, plus 4 off 16 pair to audio control point and 1 16 pair to OB
van point

Foyer speakers in 4 zones, with amplifiers and tie lines to audio patch and house Manager’s
Office.

Power Supply and technical earth to roof space, equipment room, foyers, rehearsal point and
orchestra.

Dedicated amplifier and induction loop system for hearing impaired patrons.


STAGE MANAGERS SYSTEM
Stage Managers console plug-in either side of stage.

Four ring duplex talk-back master Clearcom compatible, patchable to various areas by two
ring cabled zones.

Monitor for FOH camera.

Microphone for Back of House Paging.


OUTSIDE BROADCAST PANEL
Adjacent to truck lift area, incorporates 3 phase and neutral power 6 x 40 Amp, 1 x 60 Amp.

Talkback audio tie lines to Telecom MDF Room with 8 off Austel approved isolator
transformers 0.




                                                                                           - 23 -
HEARING AID LOOP
A Hearing Loop is available in various areas of the Stalls and Dress Circle. Patrons need to
turn their hearing aid to (T) to receive this facility.

The following seats in the Auditorium do not have Hearing Aid Loop reception:

STALLS

AAA 15-30 & AAA33-34
BBB 13-30 & BBB 33-36
AA 17-31
BB12-37
CC11-31 & CC 33-38
A 9-39
B 8-10 & B 39-41
WWW 1-10
Y 17-29 & Y 33-47
YY 33-46

DRESS CIRCLE

Box 1 seats 1-4
Box 2 seats 5-6
Box 3 seats 7-8
Box 4 seats 9-12
Box 5 seats 15-16
A 3-48
B 3-49
K 3-52
W 18-39
X 10-48
Y9-17 & Y41-49
WW 9-17 & WW 41-49
XX 9-17 & XX 41-49
YY 11-17 & YY 41-47




                                                                                         - 24 -
- 25 -
EXTERIOR POSTER BOX DIMENSIONS
POSTER BOX MEASUREMENTS

All poster Boxes have been standardised to:
A – 841mm (h) x 594mm (w)

POSTER BOX LOCATIONS

16 Poster Boxes at the front of the Theatre in Campbell Street
9 Poster Boxes at the rear of the Theatre in Hay Street

BILLBOARDS & DIMENSIONS

Billboard above the Theatre facing George Street
5400mm (h) x 12200mm (w)

Billboard on Hay Street Level
3100mm (h) x 6020mm (w)

HANGING FLAG BANNERS

The Hanging Flag Banners are situated above the awning in Campbell Street
3500mm (h) x 1950mm (w)

CAMPBELL STREET AWNING

540mm (H) x 45.5 metres (L) - Campbell Street
540mm (H) x 3.1 metres (L) – George Street

ALL ENQUIRIES
Capitol Theatre Management Pty Ltd
13 Campbell Street
Haymarket, Sydney, NSW 200
Telephone: 02 9320 5005
Email: capitol@ctm.com.au