               AutoSol Universal Communication Server Version 4.0

Communication Methods:                                         ol
                                                          AutoS OPC/DDE Server
       Serial Cable/Leased-line
       Dial-up Telephone/Cellular Phone
       Conventional, Trunking, and Spread-                                  All Major
                                                                              Brand                  OPC               DDE
        Spectrum Radio




                                                          Windows 98TM/NTM
                                                                         T
                                                                               HMI                   Client           Client
       PLC/RTU connections via TCP/IP                                                              Applic ation     Applic ation
        Ethernet                                                             Solutions
       Leased-line, dial-up or radio connections                               OPC/
                                                                                                         OPC             DDE
        via Terminal Servers on TCP/IP Ethernet                                 DDE

       Internet via TCP or UP
                                                                                    ol
                                                                               AutoS Universal Communication Server
Protocols:                                                                               AUCS Version 4.0
       Modbus RTU and ASCII
       Daniels Modbus RTU and ASCII
       Enron Modbus
       Motorola MOSCAD Modbus
       Flow Automation Modbus                                                                                             Other devices
                                                                                                                            or systems
       Delta X Modbus
                                                                                          Brand B          Brand C
       Baker 8510, Baker 8800
                                               Brand A                                    PLC
       Allen Bradley DF1 Master-Slave (Half                                                                 T
                                                                                                            RU
        Duplex)                                 PLC
       Allen Bradley DF1 Point-To-Point (Full
        Duplex)
       Fisher ROC (312, 364, 407, 503)
       GE SNPX
       GE Ethernet
       Cutler Hammer – IMPACC System Communications
       Detroit Diesel DDEC
       General Motors EMD MDEC
       Nautronix ASK
       Bristol Babcock BSAP (in development)
       Siemens (on request)

Server Interface Formats:
       OPC (OLETM for Process Control)
       Microsoft CF_TEXT, XlTable
       Rockwell Software AdvanceDDETM
       Wonderware FastDDETM

Communication Initiation:
       Interval Polling (Periodic Timer Triggered)
       Synchronous Polling (Clock or Calendar Triggered)
       Demand Polling (DDE/OPC Client Triggered)
       Exception Reporting/Cryout (Control Device, RTU or PLC Triggered)




                      AUCS is the key to integrating your automation islands.
                                   Specifications are subject to change without notice.
                                          Document No. AUCSVer4.0 040899
                   Automation Solutions Inc. ● 281-286-6017 ● 1-800-227-9707


Documentation and Configuration:
      Documentation via MS Access
      External Configuration via MS Access

SCADA Capabilities:
      Client access to communication diagnostics for
       each telemetry channel and for each
       RTU/PLC.
      One AUCS installation can support multiple
       protocols.
      Multiple protocols can be supported over one
       communication channel.
      Client control of:
               Polling Interval
               Demand Polling
               Telephone number for dial-up
      AUCS V4.0 supports redundant RTU/PLCs.
               Automation Fail-over
               Alternating
               Primary Only
               Secondary Only
      AUCS V4.0 supports redundant telemetry channels/methods to
       a single RTU/PLC.
               Automation Fail-over
               Alternating
               Primary Only
               Secondary Only
      AUCS supports Windows NT 4.0 and higher.

Server Customization:
       Toolkit available for user-developed protocols.




                      AUCS is the key to integrating your automation islands.