					                                                    VR2272B
                                             ANNUAL SURVEY REPORT



  Ship’s Details
     Ship’s Name
     IMO Number
     Port Of Registry
     Class Society
     Date Keel Laid
     Gross Tonnage


  Inspection Details
     Name of person conducting survey
     Name of Company
     Inspection Date
     Inspection Location


  Recommended Test Equipments
  The following equipment is recommended for an effective and complete survey.       Yes    No
     SVGA Computer Display                                                           
     PS2/USB Mouse                                                                   
     PS2 Keyboard                                                                    
     Laptop Computer                                                                 
     Digital Multimeter                                                              
     KW907-BT Beacon Tester                                                          


  UNIT                                      Serial Number       Software Versions
  
  VR2272B (Main Electronics Unit)                                  M3-    .      .   
  
  AI2049 VHF Interface                                             CDP-              
  
  Recoverable Capsule
  
  NOVEGA/DUKANE Beacon
  
  KW914C (Battery Backed Supply)                                                     Option 1

  
  AMI-UPS (Uninterruptible Power Supply)                                             Option 2

  
  Sailor PS4655 (AC/DC Power Supply)                                                 Option 2




2272BSRF-03 Rev05
  1. Pre-existing Alarms                                                                             Yes   No
        Confirm that no alarms were present at start of the procedure.


  2. Capsule 12 Hour Data check                                                                      Yes   No
     Confirm that 12 hrs minimum of Files are available from the Capsule.


  3. 20 Minute Data Download                                                                         Yes   No
     Confirm that 20 minutes of data is downloaded from the HDD/Capsule.


  4. Power supply alarm check                                                                        Yes   No
     Remove source of external power and confirm that the audible alarm sounds.
        Record Time (hh:mm)


  5. Battery Expiry Dates:                               Date of Install              Date of Expiry
     Reserve Power Supply - 3 Years from Install
     Sonar Beacon - 3 Years from Install


  6. Acoustic Beacon Check
        Using a high impedance multimeter confirm the applicable battery voltage.
     DUKANE has a voltage of 2.97 volts DC or greater. Record Volts                         V        
     NOVEGA has a voltage of 3.00 volts DC or greater. Record Volts                         V        
                                                                                                     Yes   No
        Using a KW907-BT check the Beacon Pulses once every second.
     If the Beacon fails during this test it is to be replaced as soon as possible.


  7. Overall Condition of Equipment
     Sub Unit                   Notes On Condition                                                   Yes   No
     Protective Capsule                                                                              
     External Cable                                                                                  
     Main Unit                                                                                       


  8. Interfaces: Operation and Recording
  Date and Time                  Preferably external to ship (e.g. Global             Yes       No
                                 Navigation satellite system.)

  Ship’s Position                Global Navigation satellite system                   Yes       No



  Speed (Through Water or        Ship’s Designated Speed and Distance                 Yes       No
  Over Ground)                   Measuring Equipment

  Heading                        Ship’s Gyro Compass                                  Yes       No



  AIS data:                      Ship’s AIS                                           Yes       No




2272BSRF-03 Rev05
  8. Interfaces: Operation and Recording (Continued)
  Bridge Audio                   Microphones                                         Yes   No     N/A
                                    Bridge Port side
                                    Bridge Centre
                                    Bridge Starboard Side
                                    Port Wing
                                    Starboard Wing

  Communications Audio           Designated VHF                                      Yes   No



  RADAR data: Post display       Master RADAR display (see ANNEX A4)                 Yes   No     N/A
  selection

  Water Depth                    Echo Sounder                                        Yes   No     N/A



  Main Alarms                    All mandatory alarms on the bridge.                 Yes   No     N/A

                                     Data is being received from interface/s

  Rudder Order and               Steering gear and Autopilot                         Yes   No     N/A
  Response                          Data is being received from interface/s

  Engine Order and               Telegraphs, Controls and Thrusters                  Yes   No     N/A
  Response                           Data is being received from interface/s

  Hull Openings Status           All status info displayed on the bridge.            Yes   No     N/A

                                      Data is being received from interface/s

  Watertight and Fire door       All status info displayed on the bridge.            Yes   No     N/A
  Status                              Data is being received from interface/s

  Acceleration and Hull          Hull stress and response monitoring                 Yes   No     N/A
  stresses                       equipment where fitted

  Bridge Navigational Watch      BNWAS equipment where fitted                        Yes   No     N/A
  Alarm System

  Wind Speed and Direction       Anemometer where fitted                             Yes   No     N/A




  9. Reserve Power source check
     Allow VDR to continue running for 1 hour 55 minutes from ‘2’ above.                        Yes   No
     Confirm the equipment is still operating at this time with no additional alarms.
        Record Time (hh:mm)
     If the batteries fail during this test they are to be replaced as soon as possible.


  10. Reserve Power source shutdown check                                                       Yes   No
     Confirm that 2 hrs 5 min from ‘2’ above that the VDR has stopped recording.
        Record Time (hh:mm)




2272BSRF-03 Rev05
  11. Change or Repair of Sensors
  Check maintenance records of VR2272B system                                     Yes    No     N/A



  Confirm any Defects properly rectified                                          Yes    No     N/A



  Confirm if any new equipment has been fitted or modified that should
  be or is connected to the VDR. If YES download the SHIPDATA.TXT
  file and modify to reflect new status in ‘Notepad’ and SAVE and replace         Yes    No     N/A
  the existing file. (see ANNEX A 6)


  12. Observations and additional or changes to Equipment fitted




  13. Signature Page
  This performance test was conducted in accordance with SOLAS regulation V/18.8 and forms part
  of the procedure for the issue of the Annual Performance Test Certificate and is related to the
  SAFETY CERTIFICATE for this vessel which is now due for revalidation on:

                                                   Date
      PLEASE NOTE THAT THIS REPORT IS NOT AN ANNUAL PERFOMANCE CERTIFICATE

  In accordance with the principals of harmonisation of certification it will remain valid until the next
  annual re-validation of that certificate, subject to the equipment being maintained in appropriate
  operational condition.

  Type Approval Certificate Issued by                      Approval Certificate Issued (VDR)
  QINETIQ - Notified Body 0191                                         QQ-MED-05/06-02R3
                                                           Approval Certificate Issued (S-VDR)
                                                                       QQ-MED-05/06-03R

  Engineer Authorised by the Manufacturer                  Ships Representative
  Initials & Name                                          Initials & Name


  Signature                                                Signature
                                                                                              Ship’s
                                                                                              Stamp
  Date                                                     Date




2272BSRF-03 Rev05
  13. Manufacturers Analysis
  This performance test was conducted in accordance with SOLAS regulation V/18.8 and forms
  part of the procedure for the issue of the Annual Performance Test Certificate.

  The results, information and any comments should be relayed to the manufacturer in accordance
  with the instructions contained within the Operation Manual.

  AMI Marine (UK) will complete a review, record any changes and issue the completed test report
  and the Annual Certificate within 45 days. To accommodate performance checks to align with
  the appropriate survey under the Harmonized System of Survey and Certification (HSSC), the
  annual performance check may be carried out up to 3 months before the due date for a
  passenger ship and -/+ 3 months of the due date for a cargo ship.


  The Authorised Engineer conducting the Annual Performance Test is to ensure the following
  items are forwarded to AMI Marine (UK) for analysis.

                                                                              Yes   No
  Confirmation that all data is available throughout the 12-hour recording.

  Confirm that a 20 minute section from the 12 hour download including        Yes   No
  the SHIPDATA.ZIP will be forwarded to AMI Marine (UK) for analysis.

  Confirm that copies of the Service report and Annual Survey Report will     Yes   No
  be forwarded to AMI Marine (UK) for review.


       Subject to a satisfactory analysis by AMI Marine (UK), the
       Annual Performance Test Certificate will then be issued.


               PLEASE NOTE THAT THIS REPORT IS NOT AN
                  ANNUAL PERFOMANCE CERTIFICATE




2272BSRF-03 Rev05
                                                       AMI MARINE (UK) Ltd,
                                              Unit 2, Tower Lane, Eastleigh, Southampton,
                                                         Hants. SO50 6NZ. U.K.
                                                    Telephone: +44 (0) 23-80480450
                                                        Fax: +44 (0) 23-80651126
                                                       E-mail technical@amimarine.net



                     Declaration of Conformity
This is to certify that the AMI VR2272B – Voyage Data Recorder System (VDR)
(COMMISSION DIRECTIVE 2002/75/EC-ITEM A.1/4.29) has been assessed, tested
and CERTIFIED as complying with the relevant parts of:

 BS EN 61996-1: 2008, “Shipborne Voyage Data Recorder (VDR)”
 BS EN 61996-2: 2006 Part 2, “Simplified Voyage Data Recorder (SVDR)”
 BS EN 60945: 2002, “General Requirements for Marine Navigation Equipment”

The VR2272B equipment conforms to the performance standards adopted by the
International Maritime Organisation, which are contained in Resolution A861 (20),
Resolution A694 (17) and MSC.163 (78) as amended by MSC.214 (81).

All Interfaces manufactured by AMI Marine (UK) have been tested and CERTIFIED as
complying with the relevant parts of:

 BS EN 61162-1 2000, “NMEA Digital Interfaces”
 BS EN 60945: 2002, “General Requirements for Marine Navigation Equipment”

All Interfaces are OPTO Isolated and will not interfere with the Ship Equipments.

The AMI VR2272B Voyage Data Recorder (VDR) has been issued by QINETIQ with the
MED Type Approval Certificate number QQ-MED-05/06-2R3

The AMI VR2272B Simplified Voyage Data Recorder (S-VDR) has been issued by
QINETIQ with the MED Type Approval Certificate number and QQ-MED-05/06-03R

QINETIQ is notified body 0191

QINETIQ
Cody Technology Park
Ively Road, Farnborough
Hampshire.
GU14 0LX




 2272BSRF-03 Rev05

				
DOCUMENT INFO
Shared By:
Categories:
Tags:
Stats:
views:16
posted:1/18/2012
language:English
pages:6