Avaya Pricing - DOC
Description
Avaya Pricing document sample
Document Sample


UPS Proposal Document: Avaya 6000 VA Online UPS
with L6-30 and L14-30 PPDM
PRICING OVERVIEW (AVAYA NPL)
Item Com Code NPL Quantity Total
6000 VA UPS 700404627 $4,399.00
PPDM, L6-30R & L14-30R 700315120 $849.00
Extended Battery Module (EBM) 700404726 $1,049.00
Extended Battery Cabinet (EBC240) 700404718 $9,249.00
05146793-
Alarm Relay Card 4101* $149.00
Extended Power Distribution Module (PDM03);
L14-30P with (4) 5-15R, (1) L6-30R, (1) L6-20R 407483361 $618.00
Extended Power Distribution Module (PDM05);
L5-30P with (8) 5-15R 407483353 $650.00
Extended Power Distribution Module (PDM06);
L5-30P with (2) 5-15R and (1) 5-50R 407505858 $650.00
Battery Extension Cable for EBM and EBC240 Call
(48 in. long) N/A 800.322.4877
Seismic Kit (Holds UPS, PPDM, EBM) 700404742 $549.00
4-Post Rail Kit 700404734 $149.00
*Part number for Business Partners.
PRODUCT OVERVIEW
The Avaya 6000 VA online UPS provides the ultimate power protection for your telecommunications systems and
equipment. With its rigorous online design, the Avaya UPS provides complete isolation from power disturbances to
protect your customer’s data and equipment.
Avaya UPS Features & Benefits
Isolates connected equipment from all incoming power problems to provide the highest degree of
protection
Doubles battery service life and gives you advanced warning of the end of useful battery life with
Advanced Battery Management (ABM) technology
Prolongs backup time with optional extended battery solutions
Adapts to rack and standalone tower applications with versatile form factor
Provides monitoring capabilities with standard Web/SNMP card
Allows you to service the UPS without shutting down connected equipment with the PowerPass
Distribution Module (PPDM)
The 6000 VA UPS can be mounted in a rack . . .
800.322.4877 Page 1 of 7 powerware.com/avaya
. . . or used as a tower unit.
Top Reasons to Buy an Avaya UPS
When it comes to providing the best possible power protection solution for your Avaya telecommunications
equipment, select the best--an Avaya UPS.
Online, Double-conversion Technology
All Avaya UPS models feature a rugged, online design where power is completely regenerated before
reaching the connected load so that no disturbances reach the connected equipment. An Avaya UPS
provides complete protection from all nine common power problems. In addition, the online design is
compatible with generators.
Advanced Battery Management (ABM)
Avaya UPS models feature Advanced Battery Management, which doubles battery service life, optimizes
recharge time, and provides advanced warning of the end of useful battery life. With increased battery life,
you won't need to replace the batteries as quickly. As a result, the total cost of ownership for an Avaya UPS
is reduced. In addition, most competitive UPS models use an LED to indicate that the batteries are dead
with no advanced notice.
Extended Backup Times
Avaya has custom solutions designed to provide up to 8 hours of backup time. Competitive UPS offerings
are often difficult to configure for long runtimes.
Avaya Authorized and Approved
Each Avaya labeled UPS is designed and tested to meet the rigorous Avaya specifications of
telecommunications and ancillary equipment.
Web/SNMP Card
Avaya models are equipped with the Web/SNMP card for advanced communication and monitoring
capabilities.
Web/SNMP Card
Included with the 6000 VA UPS, the Web/SNMP card enables you to monitor and control remote UPSs from web
browsers or industry standard network management systems. The Web/SNMP card supports real-time web and
SNMP (Simple Network Management Protocol) communication over 10/100BaseT Ethernet connections and
serves as a power-protected switching hub to support three additional 10/100BaseT links.
800.322.4877 Page 2 of 7 powerware.com/avaya
PowerPass Distribution Modules (PPDM)
The PPDMs are designed to enhance the reliability and flexibility of the 6000 VA UPS. With an integrated
maintenance bypass switch, the PPDM allows you to upgrade or replace the UPS without shutting down protected
equipment. It also provides various output receptacle options. The default module is the PPDM, L5-30R, but you
can select one of the other three models depending on your application requirements.
LanSafe Software
Each Avaya UPS ships with a CD containing LanSafe software, which delivers comprehensive support including
graceful, remote shutdown of UPS units and network monitoring tools. LanSafe supports all major operating
systems.
LanSafe Features and Benefits
Patent pending Cost $avings Calculator allows you to determine overall savings resulting from the LanSafe
monitoring system
Exclusive Stealth Mode Operation enables LanSafe to run in the background without visual traces
3-D PowerScope and ControlRoom views eliminate the guesswork from UPS metering and status
information
History View provides around-the-clock visual representation of the system event log in calendar format
ADDITIONAL PRODUCT INFORMATION
Avaya UPS web site: http://www.powerware.com/AVAYA/USA/Products/6000va.asp
Model Selection Guide
Input
Voltage Output Input Output
Model SAP Code (Vac) Voltage (Vac) Connection Connections
RS9RM 6000 VA See PPDM See PPDM See PPDM See PPDM
700404627
UPS below below below below
(1) L6-30R,
PPDM, L6-30R
700315120 208-240 208-240/120 L6-30P (1) L-14-30R,
& L14-30R
(4) 5-15R
Optional Batteries
EBM 700404726 - - - -
EBC240 700404718 - - - -
Battery Extender
None (call 800.322.4877 for details).
Cable, 48 in.
800.322.4877 Page 3 of 7 powerware.com/avaya
Dimensions & Weights
6000 VA UPS with PPDM and EBM in Tower Configuration
Dimensions Installed Shipping # of Shipping
Configuration
(H x W x D) in. Weight (lb.) Weight (lb.) Boxes1
Vertical Tower Configuration
UPS + PPDM 17.4 x 13.7 x 26.9 300.0 332.0 4
UPS + PPDM + 1 EBM 17.4 x 18.8 x 26.9 454.0 498.0 5
UPS + PPDM + 2 EBMs 17.4 x 23.9 x 26.9 608.0 664.0 6
UPS + PPDM + 3 EBMs 17.4 x 29.0 x 26.9 762.0 830.0 7
UPS + PPDM + 4 EBMs 17.4 x 34.1 x 26.9 916.0 996.0 8
With Extended Battery Cabinets (EBC240)
UPS + PPDM + 2 EBCs 28.1 x 64.7 x 76.1 2140.0 2342.0 4 + 2 pallets
UPS + PPDM + 3 EBCs 28.1 x 90.2 x 76.1 3110.0 3347.0 4 + 3 pallets
UPS + PPDM + 4 EBCs 28.1 x 115.7 x 76.1 4080.0 4352.0 4 + 4 pallets
UPS + PPDM + 5 EBCs 28.1 x 141.2 x 76.1 5050.0 5357.0 4 + 5 pallets
UPS + PPDM + 6 EBCs 28.1 x 166.7 x 76.1 6020.0 6362.0 4 + 6 pallets
Rack and Horizontal Tower Configuration
UPS + PPDM 13.7 (8U) x 17.4 x 26.9 300.0 332.0 4
UPS + PPDM + 1 EBM 18.8 (11U) x 17.4 x 26.9 454.0 498.0 5
UPS + PPDM + 2 EBMs 23.9 (14U) x 17.4 x 26.9 608.0 664.0 6
UPS + PPDM + 3 EBMs 29.9 (17U) x 17.4 x 26.9 762.0 830.0 7
UPS + PPDM + 4 EBMs 34.1 (20U) x 17.4 x 26.9 916.0 996.0 8
Individual Modules
UPS 8.6 (5U) x 17.4 x 26.9 197.0 217.0 3
PPDM 5.1 (3U) x 17.4 x 26.9 103.0 115.0 1
EBM 5.1 (3U) x 17.4 x 26.9 154.0 166.0 1
EBC240 28.1 x 25.5 x 28.2 970.0 1005.0 1 pallet
Seismic Kit 21.8 (11U) x 18.5 x 25.5 31.0 41.0 1
EPDM 5.25 x 13.0 x 8.01 7.0 10.0 1
1. Two battery trays are shipped in boxes separate from the UPS.
800.322.4877 Page 4 of 7 powerware.com/avaya
Rear Panel
Battery Backup Times
UPS with front panels removed showing two internal battery trays
Standard Internal Batteries & Extended Battery Modules (EBM)1
Standard Internal
Load (1) EBM (2) EBMs (3) EBMs (4) EBMs
Batteries
2000 VA/1400W 480 – – – –
3000 VA/2100W 300 480 – – –
4000 VA/2800W 240 360 480 – –
5000 VA/3500W 180 300 420 480 –
6000 VA/4200W 120 240 300 420 480
Standard Internal Batteries & Extended Battery Cabinets (EBC)1
Load (2) EBC (3) EBC (4) EBC (5) EBC
2000 VA/1400W 660 – – –
3000 VA/2100W 387 576 – –
4000 VA/2800W 245 480 – –
5000 VA/3500W 190 360 600 –
6000 VA/4200W 135 284 446 590
1. These tables provide typical information. Runtimes are approximate and may vary with equipment,
configuration, battery age, temperature, etc.
800.322.4877 Page 5 of 7 powerware.com/avaya
Additional Specifications1
Electrical Input
Power Rating 6000 VA/4200 watts
Nominal Voltage 208V (auto-sensing 208-240V)
Voltage Range 160-288V nominal
Nominal Frequency 50/60 Hz, auto-sensing
Dedicated Circuit Breaker
Rating 30A
Power Draw of UPS 40A
Noise Filtering MOVs and line filter for nominal and common mode noise
Connections L6-30P detachable input line cord
Power Factor >0.96
Electrical Output
Nominal Voltage 208-240/120 Vac
Voltage Regulation ±3% (nominal for normal and battery modes)
Voltage Waveform Sine wave
Output Receptacles (1) L6-30R, (1) L14-30R, (4) 5-15R
Communications
Web/SNMP Card Manage and monitor the UPS via the internet or SNMP protocol;
included as standard
Communication Ports USB and serial ports standard
NetWatch Clients CD Bundled with UPS
Software Suite CD Power management software for all major operating systems
included
Environment & Safety
Operating Temperature 32 to 104°F (0 to 40°C)
Storage Temperature 32 to 77°F (0 to 25°C )
Transit Temperature -13 to 131°F (-25 to 55°C )
Relative Humidity 5-95% noncondensing
Operating Altitude Up to 3,000 meters above sea level
Transit Altitude Up to 10,000 meters above sea level
Heat Dissipation 2066 BTU/hr, maximum
Audible Noise <50 dBA during normal mode; <60 dBA during battery mode
Leakage Current <0.6 mA
Surge Suppression ANSI C62.41 Category B3; EN 61000-4-5 Level 3, Criteria B
Safety
Conformance UL1778; CAN/CSA C22.2, No. 107.1, 107.2; EN 50091-1-1 and IEC
60950; NOM-019-SCFUI
Agency Markings UL, cUL, NOM-NYCE, CE, EMC (Class A) EN 50091-2, FCC Part
15, ICES-003
Battery
Battery Type Sealed, maintenance-free, valve-regulated, lead-acid
UPS Configuration (20) 12V, 7.2 Ah batteries (included as standard)
EBM Configuration (20) 12V, 9 Ah batteries
UPS Battery Charging <2 hours to 80% usable capacity at nominal line voltage after full
load discharge
EBM Battery Charging No more than 15x discharge time to 90% usable capacity at nominal
line voltage after full load discharge
1. Due to continuing product improvement programs, specifications are subject to change without notice.
800.322.4877 Page 6 of 7 powerware.com/avaya
OPTIONS
Seismic Kit
The seismic kit stabilizes the UPS in areas such as California that have earthquake safety requirements. The seismic
kit holds the UPS, the PPDM, and an EBM (a total of 11U). It is equipped with casters (wheels) for easy movement
and a set of brackets that can be used to bolt the kit to the floor. You can use multiple seismic kits if you have more
than 1 EBM, but be sure to order a 48-inch battery extender cable.
Extended Power Distribution Modules (EPDM)
EPDMs provide additional output receptacle choices. For example, PDM06 pictured above is designed with a
5-50R output receptacle for 120V DEFINITY installations.
4-post Rail Kit
The UPS ships with mounting ears and handles. However, they do not completely support the UPS in a rack
enclosure. If a shelf does not support the UPS, you'll need to order the optional rackmount kit. Order 1 kit per UPS
and 1 kit per EBM. For example, order 3 kits for a configuration with a UPS, a PDM, and an EBM.
Alarm Relay Card
The Alarm Relay Card is used to connect the UPS to a DEFINITY Remote Maintenance Board to monitor alarm
contacts. It fits into the option slot on the rear panel of the UPS.
800.322.4877 Page 7 of 7 powerware.com/avaya
Get documents about "