0

METHOD STATEMENT

Page No. : 1 of 7









GENERAL INFORMATION





THIS DOCUMENT IS ENTENDED FOR REFRENCE PURPOSES

ONLY. YOU CAN EDIT & MODIFY THE CONTENT.



DOWNLOAD THIS DOCUMENT ON THIS BELOW LINK

http://www.unfoldsecrets.com/forum



OFFICIAL UNFOLD SECRETS WEBSITE

http://www.unfoldsecrets.com



OUR BLOG ARTICLE PAGE

http://www.unfoldsecrets.com/articles



SIGN OUR GUESTBOOK

http://unfoldsecrets.com/Guest-book.php



JOIN US NOW

http://unfoldsecrets.com/login/index.php









For more downloads of documents, read articles, templates & more visit

http://www.unfoldsecrets.com/forum

*CLIENT NAME HERE

* LOGO HERE REV.

* PROJECT NAME HERE Date: 03 -02- 2008

0

METHOD STATEMENT

Page No. : 2 of 7









METHOD STATEMENT FOR INSTALLATION

OF CABLE TRAY/TRUNKING/LADDER









Project : * PROJECT NAME HERE

Contractor : *CONTRACTOR NAME HERE

Document No. :



Document revision status : 0









For more downloads of documents, read articles, templates & more visit

http://www.unfoldsecrets.com/forum

*CLIENT NAME HERE

* LOGO HERE REV.

* PROJECT NAME HERE Date: 03 -02- 2008

0

METHOD STATEMENT

Page No. : 3 of 7



0 03-02-2008 Issued for Review & Comments



Prepared by Checked by Approved by

Rev. Date Description

*CONTRACTOR NAME HERE









REVISION CONTROL SHEET





REV. NO. DATE PAGE NO. DESCRIPTION



0 03-02-2008 ALL FIRST ISSUE









For more downloads of documents, read articles, templates & more visit

http://www.unfoldsecrets.com/forum

*CLIENT NAME HERE

* LOGO HERE REV.

* PROJECT NAME HERE Date: 03 -02- 2008

0

METHOD STATEMENT

Page No. : 4 of 7









TABLE OF CONTENTS







1 Purpose…………………………………………………………………………….. 5

2 Scope of Work…………………………………………………………………….. 5

3 Responsible Personnel on Site………………………………………………… 5

4 Storage…………………………………………………………….………………. 5

5 Pre-Installation…………………………………………………………………… 5

6 Installation………………………………………………………………………… 5

7 Reference Documents…………………………………………………………. 6

8 Safety……………………………………………………………………………… 6









For more downloads of documents, read articles, templates & more visit

http://www.unfoldsecrets.com/forum

*CLIENT NAME HERE

* LOGO HERE REV.

* PROJECT NAME HERE Date: 03 -02- 2008

0

METHOD STATEMENT

Page No. : 5 of 7









1. Purpose



This method of statement covers the on-site installation of Cable Trays, Trunking &

Cable Ladders as defined in the General Specification.







2. Scope of Works



This procedure will define the method to be used to ensure that cable trays, trunking &

ladders installations are correct and acceptable and shall conform to the Contract

Documents and Specification.







3. Responsible Personnel on Site



3.1. Construction Manager

3.2. Electrical Field Engineers

3.3. Safety Officer

3.4. QA/QC Engineer

3.5. Electrical Supervisors







4. Storage



4.1 Cable Trays, Trunking and Ladders shall be properly supported and stacked on a flat

surface.



4.2 Cable Trays, Trunking and Ladders shall be protected from sunlight and moisture by

covering them with tarpaulin.



4.3 Cable Trays, Trunking and Ladders shall be stacked properly in neat and orderly

manner.



4.4 Cable Trays, Trunking and Ladders shall be stored and stacked in dry area and shall be

properly protected..









For more downloads of documents, read articles, templates & more visit

http://www.unfoldsecrets.com/forum

*CLIENT NAME HERE

* LOGO HERE REV.

* PROJECT NAME HERE Date: 03 -02- 2008

0

METHOD STATEMENT

Page No. : 6 of 7









5. Pre-Installation



5.1 All materials and documentation relevant to this particular Section of works will be

checked by the Construction Department prior to the commencement of works ensuring

that these are correct type as reviewed.



5.2 Before any permanent works will proceed, pre-inspection on all materials, tools and

access for installation to be carried out.







6. Installation



6.1 Establish the Cable Trays, Trunking and Ladder route on slab soffit and walls, and mark

with chalk liner. Ensure that the route conform with the latest coordinated services

drawings.



6.2 Mark the locations of supports. For horizontal installation spacing between supports

shall not exceed 1.5m for trunking and 1.2m for cable trays and ladders and not more

than 150mm from all bends and tees. For vertical installation, spacing between supports

shall not exceed 3m for trunking and 1.5m for cable trays and ladders.



6.3 Install the threaded rod and angle bar supports for horizontal installation and uni-strut

channel for vertical supports. Make sure that the supports are properly anchored, rigid

and aligned.



6.4 Install Cable trays, trunking and ladders ensuring that it is properly fixed to its supports.

Where necessary to cut the cable trays, the cutting line of the cable trays shall be

through continuous metal parts and not through the perforation. Burrs and sharp ends

shall be removed prior to the installation of tray section or accessories.



6.5 Cable Trays, Trunking and Ladders shall be connected to adjacent lengths, tees, bends

and fittings with approved couplers and securely fastened by mushroom head steel

roofing bolts and nuts. Connection shall be mechanically strong so that there is no

relative movement between joints.



6.6 Earth links shall be fixed on the adjacent connection of Cable trays, trunking and

ladders and fittings to maintain the electro-mechanical continuity on the runs of cable

trays, trunking and ladders.



For more downloads of documents, read articles, templates & more visit

http://www.unfoldsecrets.com/forum

*CLIENT NAME HERE

* LOGO HERE REV.

* PROJECT NAME HERE Date: 03 -02- 2008

0

METHOD STATEMENT

Page No. : 7 of 7



6.7 Where cable tray or cable ladder crosses, expansion joints, adjacent length of cable tray

or ladder shall not be joined and shall be bridged only with a flexible earth connector.









6.8 A minimum clear space of 25mm shall be kept behind all installed runs of cable trays.

Where in a cable trays carrying power cables run in parallel with low current cable trays,

a 300mm minimum clear distance shall be kept throughout the installation.



6.9 Raise Request for Inspection for the Cable Trays, Trunking and Ladders Installation.







7. Reference Documents



7.1 Approved Electrical Shop Drawings

7.2 Approved Material Submittals

7.3 Approved Material Inspection Report

7.4 Approved Safety Plan

7.5 Approved QA/QC Inspection & Test Plan.





8. Safety



8.1 All safety precautions shall be followed as per approved safety plan & procedure.

Ensure all involved persons are aware of the same.



8.2 Safety Officer to ensure that all working flat forms shall be safe and in good

condition.



8.3 Tradesman shall ensure that before leaving their working places, it must be clean,

tidy and free from rubbish.









------------------------ Procedure End----------------------



For more downloads of documents, read articles, templates & more visit

http://www.unfoldsecrets.com/forum





For more downloads of documents, read articles, templates & more visit

http://www.unfoldsecrets.com/forum


Related docs
Other docs by airgil daviss
Expense Reimbursement New Version New Version
Views: 3  |  Downloads: 0
MOS Fixing Manholes Part 1
Views: 2  |  Downloads: 0
Specification of Carpentry & Joinery
Views: 3  |  Downloads: 0
Specification of Airoutlet & Inlets
Views: 4  |  Downloads: 0
Method of Statement for Cable Tray Revised
Views: 24  |  Downloads: 0
Specification of Waterproofing New Versions
Views: 2  |  Downloads: 0
Minutes of Meeting templates Part 1
Views: 1  |  Downloads: 0
Minutes of Meeting templates Part 1
Views: 1  |  Downloads: 0