					Konica                   MATERIAL SAFETY DATA SHEET
 MSDS:                  1994002021                                           Important Notice
                                                                  A hard copy of this document may not be
 Date Prepared:         02/08/94                                  the document in effect. The current version
 Date Revised:          08/10/97                                  is always the version on the Konica Graphic
                                                                  Imaging computer system.


                                                                                                            Page 1 of 4

1) CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
      Product Name: Negative Developer Replenisher GCDR-15A
              Code: 8730 A

         Company Name:
         Konica Graphic Imaging, Inc.
         71 Charles Street
         Glen Cove, New York 11542 U.S.A.

         Emergency Phone No.
              (516) 674-2500               (M – F, 8am – 5pm)
              (516) 674-2607               (Nights, Weekends, and Holidays)
         CHEMTREC
              (800) 424-9300

2)       COMPOSITION/INFORMATION ON INGREDIENTS
                  INGREDIENTS                       CAS NO.           WT. %         OSHA PEL           ACGIH TLV
      Water                                         7732-18-5         50-55           -------            -------

      Substituted amine derivative                   Company          20-25         None             None
                                                   Confidential                     established      established

      Ethylene glycol                                 107-21-1        10-15         50 ppm           50 ppm
                                                                                    (CEILING)        (CEILING)

      Polyoxyethylene derivative                     Company          10-15         None             None
                                                   Confidential                     established      established




3) HAZARDS IDENTIFICATION
                                             EMERGENCY OVERVIEW
                                   Clear, pale yellow solution. Slight aromatic odor.


     POTENTIAL HEALTH EFFECTS
     Eye effects:                        May cause eye and mucous membrane irritation.
     Skin effects:                       May cause slight skin irritation.
     Ingestion effects:                  None currently known.
     Inhalation effects:                 Low health effects for recommended handling.
     Chronic effects/Carcinogenicity:    No identified health effects.
                                         None of the components in this material are listed by IARC, NTP, or
                                         ACGIH as a carcinogen.
Konica                 MATERIAL SAFETY DATA SHEET
MSDS:                 1994002021                                       Important Notice
                                                            A hard copy of this document may not be
Date Prepared:        02/08/94                              the document in effect. The current version
Date Revised:         08/10/97                              is always the version on the Konica Graphic
                                                            Imaging computer system.


                                                                                                      Page 2 of 4

4) FIRST AID MEASURES
  Eyes:        Immediately flush eyes with plenty of water for 15 minutes. Get medical attention immediately.
  Skin:        Wash with water for 15 minutes.
  Ingestion:   Wash out mouth with water. Drink one or two glasses of water. Get medical attention. ONLY
               induce vomiting at the instruction of a physician. Never give anything by mouth to an
               unconscious person.
 Inhalation:   If symptoms occur move victim to fresh air. If symptoms persist get medical attention.


5) FIRE FIGHTING MEASURES
  Flash Point:                            Not available.
  Method Used:                            Not available.
  Flammable Limits:                       Not available.
  Autoignition Temperature:               Not available.
  Flammability Classification:            Not available.
  Unusual Fire and Explosion Hazard:      May be flammable when the moisture of the solution
                                          evaporates at high temperatures.
  Extinguishing Media:                    Water spray, dry chemical, carbon dioxide, alcohol-resistant
                                          foam.
  Fire Fighting:                          Wear self-contained breathing apparatus and protective
                                          clothing to prevent contact with skin and eyes. Move container
                                          from fire area if you can do it without risk.
  Hazardous Combustion Products:          Carbon monoxide, carbon dioxide, and nitrogen oxides.

6) ACCIDENTAL RELEASE MEASURES
  Spill and Leakage Procedures:
  Wear personal protective equipment (See Section 8). Absorb spill with inert material (e.g. dry sand or
  earth), then place in a chemical waste container. In case of large spill use the emergency telephone
  numbers shown on the front of this sheet. Non-emergency technical questions should be directed to the
  technical information number shown on the front of this sheet.

7) HANDLING AND STORAGE
  Handling:
      Keep out of reach of children. Avoid contact with eyes, skin, and clothing. Wear personal protective
      equipment (See Section 8). Use with adequate ventilation. Wash thoroughly after handling.
  Prevention of Fire and Explosion:
      Keep away from heat and flame.
  Storage:
      Keep container tightly closed. Store in a cool and dry place. Keep away from incompatible substances
      (See Section 10).
Konica                MATERIAL SAFETY DATA SHEET
MSDS:                1994002021                                        Important Notice
                                                            A hard copy of this document may not be
Date Prepared:       02/08/94                               the document in effect. The current version
Date Revised:        08/10/97                               is always the version on the Konica Graphic
                                                            Imaging computer system.


                                                                                                      Page 3 of 4

8) EXPOSURE CONTROLS/PERSONAL PROTECTION
  Engineering Controls
      Use with adequate ventilation.
  Respiratory Protection:
      Not required under normal conditions.
  Skin Protection:
      Impervious gloves should be worn.
  Eye Protection:
      Safety glasses should be worn.
  Exposure Limits:
      See Section 2.

9) PHYSICAL AND CHEMICAL PROPERTIES
   Appearance:                   Clear, pale yellow solution.
   Odor:                         Slight aromatic odor
   pH:                           7.3-7.8
   Vapor Pressure:               Not available.
   Vapor Density (Air = 1):      Not available.
   Evaporation Rate:             Not available.
   Boiling Point:                Not available.
   Melting Point:                Not applicable.
   Solubility:                   Completely soluble in water.
   Specific Gravity (H2O = 1):   1.10-1.20



10) STABILITY AND REACTIVITY
   Stability:                              Stable.
   Conditions to avoid:                    Excessive heat.
   Incompatibility:                        Strong oxidizers.
   Hazardous decomposition products:       Carbon monoxide, carbon dioxide, and nitrogen oxides.
   Hazardous polymerization:               Will not occur.

11) TOXICOLOGICAL INFORMATION
   Product
      Acute oral toxicity:                            No data
      Eye irritation:                                 No data
      Skin irritation:                                No data
      Skin sensitization:                             No data
      Carcinogenicity:                                Not known to be a carcinogen
      Mutagenicity:                                   Not known to be a mutagen
Konica                MATERIAL SAFETY DATA SHEET
MSDS:                1994002021                                        Important Notice
                                                            A hard copy of this document may not be
Date Prepared:       02/08/94                               the document in effect. The current version
Date Revised:        08/10/97                               is always the version on the Konica Graphic
                                                            Imaging computer system.


                                                                                                      Page 4 of 4



12) ECOLOGICAL INFORMATION
  [Ethylene glycol]
      Biodegradation: Readily Biodegradable
      Fish acute toxicity: 24hr LD50 = >5,000 mg/l -modified ASTM D 1345(goldfish)
      Daphnia acute toxicity: 48hr EC50 = 10,000 mg/l
      Algae growth inhibition: no effect 1 g/l (Scenedesmus)
      Octanol/water partition coefficient: LogPow = -1.930

13) DISPOSAL CONSIDERATIONS
  When disposing of the waste or recovered material, consult federal, state, and/or local regulations for the
  proper disposal method. Discharge to sewer requires approval of the permitting authority and may require
  pretreatment.

14) TRANSPORT INFORMATION
  UN/NA #         Not Regulated
  D.O.T. Class    Not Regulated

15) REGULATORY INFORMATION
  OSHA Hazard Communication Standard, 29CFR 1910.1200:
     This product is not considered hazardous under this standard.
  CERCLA (Comprehensive Environmental Response Compensation and Liability Act)
     None
  SARA Title III (Superfund Amendments and Reauthorization Act)
        302 Extremely Hazardous Substance        None
    311/312 Hazard Categories                    None
        313 Reportable Ingredients               Ethylene glycol

16) OTHER INFORMATION
  Prepared by:
     Konica Corporation
     No. 26 Nishishinjuku 1-chome
     Shinjuku-ku, Tokyo 163-05, Japan




          The above information is believed to be accurate and represents the best information
 currently available to Konica Corporation. However, Konica Corporation makes no warranty with respect to
 such information, and Konica Corporation assumes no liability resulting from its use. Users should make
 their own investigations to determine the suitability of the information for their particular purposes.