Specification sheet - VEGACAL 64 - Capacitive rod electrode for

Reviews
Specification sheet VEGACAL 64 Foundation Fieldbus Capacitive rod electrode for continuous level measurement Technical data Measuring range Process fitting Process pressure Process temperature 0.2 … 6 m (0.7 … 20 ft) Thread from G¾ A, flange from DN 25 -1 … 64 bar (-100 … 6400 kPa / -14.5 … 928 psig) -50 … +200 °C (-58 … +392 °F) Ambient, storage and transport -40 … +80 °C (-40 … +176 °F) temperature Operating voltage Materials The wetted parts of the instrument are fully FEP insulated. You can find a complete overview of the available materials and seals in the "configurator" on our homepage at www.vega.com/configurator. Housing versions The housings are available as single chamber or double chamber version in plastic, stainless steel or aluminium. They are available in protection ratings up to IP 68 (1 bar). Electronics versions The instruments are available in different electronics versions. Apart from the two-wire electronics with 4 … 20 mA/HART, there are two pure digital versions with Profibus PA and Foundation Fieldbus possible as well as one version for connection to a signal conditioning instrument. Approvals The instruments are suitable for use in hazardous areas and are approved e.g. according to ATEX, FM, CSA and IEC. The instruments have also different ship approvals such as e.g. GL, LRS or ABS. You can find detailed information on the existing approvals in the "configurator" on our homepage under www.vega.com/configurator. 9 … 32 V DC Application area VEGACAL 64 is a level sensor for continuous level measurement in all areas of industry. Fully insulated probes such as VEGACAL 64 are preferably used in conductive liquids. It is suitable for all viscous and adhesive products. Advantages • Suitable for very adhesive products • Service proven, robust and maintenance-free • High reliability • Easy mounting and setup • Measurement along the complete probe length • Highly resistant insulating material of FEP Function Sensor and vessel form the two electrodes of a capacitor. A capacitance change is generated by a level change which is converted in the connected processing electronics into a continuous output signal. VEGA Grieshaber KG, Am Hohenstein 113, 77761 Schiltach/Germany, www.vega.com 34612-EN-090623 Specification sheet Operation The adjustment of the instrument is carried out via the optional indicating and adjustment module PLICSCOM or via a PC with the adjustment software PACTware and respective DTM. Another adjustment possibility is a configuration tool for Foundation Fieldbus instruments. Dimensions SW 36 mm (1.42") G¾ A ø 40 mm (1.58") 22 mm (0.87") ø 16 mm (0.63") L 3 1 2 VEGACAL 64 1 2 3 Threaded version Flange version Temperature adapter Information You can find further information about the VEGA product line on our homepage www.vega.com. You can find free-of-charge operating instructions, product information, brochures, approval documents, instrument drawings, etc. in the download section under www.vega.com/downloads. There, you will also find GSD and EDD files for Profibus PA systems as well as DD and CFF files for Foundation Fieldbus systems. Typ: Bus Sim. Display I²C Electrical connection 5 1 Device selection With the "finder" you can select the measuring principle best suiting your application: www.vega.com/finder. You can find detailed information on the instrument versions in the "configurator" on our homepage under www.vega.com/configurator. Contact You can find the VEGA agency serving your area on our homepage www.vega.com. 1 2 5 6 7 8 4 2 3 Electronics and connection compartment, single chamber housing 1 2 3 4 5 Plug connector for VEGACONNECT (I²C interface) Spring-loaded terminals for connection of the external indication VEGADIS 61 Ground terminal for connection of the cable screen Spring-loaded terminals for voltage supply Simulation switch ("on" = mode for simulation release) You can find details on the electrical connection in chapter "Connecting to power supply" in the operating instructions of the instrument. You can download the operating instructions from our homepage at www.vega.com/downloads. 34612-EN-090623 VEGA Grieshaber KG, Am Hohenstein 113, 77761 Schiltach/Germany, www.vega.com 102 mm (4.02") 56 mm (2.21") 56 mm (2.21")

Related docs
premium docs
Other docs by Lucysiefker
Acquisition by Creation
Views: 273  |  Downloads: 8
Evidence Outline
Views: 660  |  Downloads: 83
Outstanding Books for the College Bound
Views: 451  |  Downloads: 15
app001
Views: 107  |  Downloads: 0
Duty1
Views: 123  |  Downloads: 0
a33
Views: 194  |  Downloads: 1
cm180
Views: 128  |  Downloads: 0
Second half outline
Views: 270  |  Downloads: 2
at167
Views: 97  |  Downloads: 0
Short Summary of US History: 1900 to 2006
Views: 924  |  Downloads: 12
ch102
Views: 121  |  Downloads: 0
Counter offer
Views: 659  |  Downloads: 30
Slattery Betterton
Views: 210  |  Downloads: 0
Civil Procedure notes
Views: 315  |  Downloads: 6
Form 8K_1-25-06_Closing of Merger
Views: 273  |  Downloads: 7