p615 6E3 及其竞争产品特性对比表
IBM - eServer HP - HP - hp Sun - Fire 280R
pSeries 615 AlphaServer server Server
Model 6E3 DS25 rp5430
Product Type Entry-Level Entry-Level Entry-Level Entry-Level
Server Server Server Server
Architecture RISC RISC RISC RISC
Platform UNIX, LINUX UNIX, Other OS UNIX UNIX
Form Factor Tower Rack, Tower Rack Rack
Manufacturer IBM Corp. Hewlett Packard Hewlett Sun
Packard Microsystems
Announced 27-May-03 05-Aug-02 01-Nov-01 27-Sep-00
CPU POWER4+ Alpha 21264C PA-8700 UItraSPARC-III
(1.2GHz) (1GHz) (750MHz), Cu (1.2GHz),
PA-8700+ UItraSPARC-III
(875MHz) Cu (1.015GHz),
UItraSPARC-III
Cu (900MHz)
Max CPUs 2 2 2 2
Cache 8MB L3 8MB L2 2.25MB 8MB L2
(PA-8700)
Memory Minimum 1 0.5 0.5 0.5
(GB)
Memory 16 16 8 8
Maximum (GB)
Memory Options 1GB (4 x 512MB (4 x 128 512MB, 512MB (4 x
256MB), 2GB MB DIMMs), 1024MB, 128MB), 1GB (4
(4 x 512MB), 1GB (4 x 256 2048MB x 256MB), 2GB
4GB (4 x 1GB), MB DIMMS), SDRAM (4 x 512MB),
8GB (4 x 2GB) 2GB (4 x 4GB (4 x 1GB)
ECC DDR 512MB), 4GB (4 DIMMs
SDRAM DIMMs x 1GB) ECC
SDRAM memory
kits
Storage Minimum 36 18 18 36
(GB)
Storage Max Int 1174 872 584 146
(GB)
Storage Options 36.4GB, 36.4GB, 36GB, 73GB 36GB, 73GB
73.4GB, 72.8GB, 146GB Ultra320 FC-AL
146.8GB Ultra320 SCSI SCSI 10,000rpm
Ultra3 SCSI 10,000rpm 15,000rpm hot-swap
10,000rpm 18.2GB, hot-swap
36.4GB, 36.4GB, 72.8GB 146GB
73.4GB Ultra3 Ultra320 SCSI Ultra320
SCSI 15,000rpm SCSI
15,000rpm hot 10,000rpm
swap hot-swap
Bus Technology PCI-X PCI PCI PCI
I/O Notes 4 x 4 x 64-bit PCI 3 x 64-bit,
64-bit/133MHz 64-bit/66MHz slots 33MHz 1 x
hot swap 3.3v PCI slots 2 x 64-bit,
PCI-X slots 2 x 64-bit/33MHz 33/66MHz
32-bit/66MHz PCI slots
hot swap 3.3v
PCI-X slots
Max Slots 6 6 6 4
Std Slots 6 6 6 4
Operating System AIX; Linux Tru64 UNIX, HP-UX 11i, Solaris 8;
OpenVMS 11.0 Solaris NEO 2.0,
Solaris
OpenStep 1.0
Rack Units 5 7 4
Total Bays 11 7 4 4
Physical Enclosure Enclosure Enclosure Enclosure
Characteristics - Dimensions - Dimensions (H - Dimensions - Dimensions (H
(H x W x D): x W x D): 22.2 (H x W x D): x W x D): 17.6
53.3 x 20.1 x (5U) x 44.5 x 36.8 (7U) x (4U) x 43.8 x
58.4 cm 66.0 48.2 x 77.4 69.2 cm
- Weight: 43.1 (Rackmount) cm - Weight: 34 kg
(max) kg cm - Weight: 68 - Heat: 1650
- Heat: 794 - Weight: 40 kg BTU/hr
Btu/hr (max) (max) kg - Heat: 4380
- Heat: 2664 BTU/hr
BTU/hr (max)
Site Planning Power: Power: 100/240 AC Input Power: 100 -
100-127V or V AC, 50/60Hz Power - 240 VAC, 47 -
200-240V AC, Temperature: 100-240V 63Hz
300 watts 10° - 35° C (50° 50/60 Hz Operating
(typical); 450 - 95° F) Typical and temperature: 5
watts Humidity: 20% Maximum to 40°C (41 to
(maximum) - 90% power - 104°F)
Temperature: non-condensing 880W and Non-operating
10° to 43°C Altitude: 1283W temperature:
(50° to 109°F) 3,037m Maximum -20 to 60°C (-4
Relative (10,000ft) heat to 140°F)
humidity: 8% Noise: 46 dBA BTUs/hour - Operating
to 80% 4380 (3000 - humidity: 20%
Noise: 6 Bels typical) to 80% relative
Operating humidity,
Temperature noncondensing
- 5 to 35 Non-operating
degrees C humidity: 5% to
Operating 95% relative
relative humidity,
Humidity - noncondensing
15% to 80%
non
condensing
Operating
Altitude
above sea
level - 3KM
(10,000
feet)
Reliability & ECC on system ECC Memory ECC Memory, ECC memory
Servicability memory and and cache Redundant and cache Hot
L2 cache Hot Hot-Swap disks, Hot-swap swap hard
swap disk power supplies fans and drives
drives and PCI and fans Auto power, Redundant hot
slots PCI reboot Thermal hot-plug swap power
extended error Management disks, supplies
handling Disk Remote system parallel SCSI Hot-plug power
drive fault management PCI buses subsystems
tracking and Redundant Front-accessible
warning hot-plug power drives
Optional
redundant
power and
cooling CPU
de-allocation
Service
processor
Memory error
correction
extensions
System Electronic Insight HP Secure Sun
Management Service Agent - Manager: Web Console Management
integrated Server/network - Allows Center, Sun
system software multiple Remote System
environmental management (maximum Control, Sun
monitoring and utility, consists of four) Cluster, Sun PC
alerting which of a Windows operators in NetLink,
includes based console different Solstice
voltage, fan application and remote JumpStart,
speed and server based locations to Solaris
temperature management manage the WebStart,
sensing. Allows data collection server using Solstice
programmable agents. standard AdminSuite,
re-booting Monitors over Netscape Solstice
after power 1,000 Internet DiskSuite,
loss, hardware parameters, browser Solstice Backup,
checkstop including software. and other
failure, systems health, This is Solstice
machine check configuration achieved via products
interrupt or and password
operating performance encrypted
system hang or Remote Server console
failure. Management: access. HP
Integrated Web QoS
remote (Quality of
management Service) -
console (RMC) Allows
monitors consistent
system power, response
temperature times
and fans. irrespective
Capable of of load
performing levels.
system halt, Balances
reset or power server loads
on/off by directing
functions. requests
away from
the most
utilised local
or remote
servers. Web
QoS
supports
both Apache
and
Netscape
Web Servers.
Hp Ignite/UX
- Allows
replication of
HP-UX
installation
from single
server to
multiple
servers.
Capacity On No No No No
Demand
Clustering Yes - Cluster Yes Yes
1600
p615 6C3 及其竞争产品特性对比表
IBM - eServer Fujitsu - HP - HP - hp Sun - Fire 280R Sun - Fire V240
pSeries 615 PRIMEPOWER AlphaServer server Server Server
Model 6C3 Model 250 DS25 rp5430
Product Type Entry-Level Entry-Level Entry-Level Entry-Level Entry-Level Entry-Level
Server Server Server Server Server Server
Architecture RISC RISC RISC RISC RISC RISC
Platform UNIX, LINUX UNIX UNIX, Other OS UNIX UNIX UNIX
Form Factor Rack Rack, Tower Rack, Tower Rack Rack Rack
Manufacturer IBM Corp. Fujitsu Ltd. Hewlett Hewlett Sun Sun
Packard Packard Microsystems Microsystems
Announced 27-May-03 21-May-03 05-Aug-02 01-Nov-01 27-Sep-00 08-Apr-03
CPU POWER4+ SPARC64 V Alpha 21264C PA-8700 UItraSPARC-III UItraSPARC-IIIi
(1.2GHz) (1.1GHz) (1GHz) (750MHz), Cu (1.2GHz), (1GHz)
PA-8700+ UItraSPARC-III
(875MHz) Cu (1.015GHz),
UItraSPARC-III
Cu (900MHz)
Max CPUs 2 2 2 2 2 2
Cache 8MB L3 1MB L2 8MB L2 2.25MB 8MB L2 1MB L2
(PA-8700)
Memory 1 0.5 0.5 0.5 0.5
Minimum (GB)
Memory 16 16 16 8 8 8
Maximum
(GB)
Memory 1GB (4 x 512MB (4 x 128 512MB, 512MB (4 x 512MB (2 x
Options 256MB), 2GB MB DIMMs), 1024MB, 128MB), 1GB (4 256MB), 1GB
(4 x 512MB), 1GB (4 x 256 2048MB x 256MB), 2GB (2 x 512MB),
4GB (4 x 1GB), MB DIMMS), SDRAM (4 x 512MB), 2GB (2 x 1GB)
8GB (4 x 2GB) 2GB (4 x 4GB (4 x 1GB) PC2100 ECC
ECC DDR 512MB), 4GB (4 DIMMs DDR RDIMMs
SDRAM DIMMs x 1GB) ECC
SDRAM
memory kits
Storage 36 36 18 18 36 36
Minimum (GB)
Storage Max 1174 882 872 584 146 144
Int (GB)
Storage 36.4GB, 36GB, 73GB, 36.4GB, 36GB, 73GB 36GB, 73GB 36GB Ultra160
Options 73.4GB, 147GB 72.8GB, 146GB Ultra320 FC-AL SCSI disk drive
146.8GB Ultra320 Ultra320 SCSI SCSI 10,000rpm 10,000rpm 1"
Ultra3 SCSI SCSI 10,000rpm 15,000rpm hot-swap hot swap
10,000rpm 10,000rpm 18.2GB, hot-swap
36.4GB, hot swap 36.4GB, 146GB
73.4GB Ultra3 72.8GB Ultra320
SCSI Ultra320 SCSI SCSI
15,000rpm hot 15,000rpm 10,000rpm
swap hot-swap
Bus PCI-X PCI PCI PCI PCI PCI
Technology
I/O Notes 4 x 2 x 64-bit 4 x 64-bit PCI 3 x 64-bit, 1 x
64-bit/133MHz 66/33MHz 64-bit/66MHz slots 33MHz 1 x 64-bit/66MHz
hot swap 3.3v slots 4 x PCI slots 2 x 64-bit, PCI slot 2 x
PCI-X slots 2 x 64-bit 33MHz 64-bit/33MHz 33/66MHz 64-bit/33MHz
32-bit/66MHz slots PCI slots PCI slots
hot swap 3.3v
PCI-X slots
Max Slots 6 6 6 6 4 3
Std Slots 6 6 6 6 4 3
Operating AIX; Linux Solaris Tru64 UNIX, HP-UX 11i, Solaris 8; Solaris
System OpenVMS 11.0 Solaris NEO 2.0,
Solaris
OpenStep 1.0
Rack Units 4 2 5 7 4 2
Total Bays 11 8 7 4 4 5
Physical Enclosure Enclosure Enclosure Enclosure Enclosure Enclosure
Characteristics - Dimensions - Dimensions - Dimensions (H - - Dimensions (H - Dimensions
(H x W x D): (H x W x D): x W x D): 22.2 Dimensions x W x D): 17.6 (H x W x D):
17.8 (4U) x 52.9 x 35.0 x (5U) x 44.5 x (H x W x D): (4U) x 43.8 x 8.8 (2U) x 42.5
43.7 x 50.8 cm 60.0 (Tower) 66.0 36.8 (7U) x 69.2 cm x 63.5 cm
- Weight: 43.1 cm (Rackmount) 48.2 x 77.4 - Weight: 34 kg - Weight: 19 kg
(max) kg - Weight: cm cm - Heat: 1650
- Heat: 794 (max) 55 kg - Weight: 40 - Weight: 68 BTU/hr
Btu/hr (max) - Heat: 3,060 (max) kg kg
Kj/hr - Heat: 2664 - Heat: 4380
BTU/hr (max) BTU/hr
Site Planning Power: Power: Power: AC Input Power: 100 - Power: 2 x
100-127V or 100-240 VAC 100/240 V AC, Power - 240 VAC, 47 - 400W
200-240V AC, (auto 50/60Hz 100-240V 63Hz Operating
300 watts ranging), Temperature: 50/60 Hz Operating temperature:
(typical); 450 50/60 Hz, 10° - 35° C Typical and temperature: 5 5° - 40°C (41°F
watts 630W (50° - 95° F) Maximum to 40°C (41 to - 104°F)
(maximum) (rackmount), Humidity: 20% power - 104°F) Operating
Temperature: 850W - 90% 880W and Non-operating humidity: 10%
10° to 43°C (floorstand) non-condensing 1283W temperature: - 90% relative
(50° to 109°F) Temperature: Altitude: Maximum -20 to 60°C (-4 humidity
Relative 5° to 35° C 3,037m heat to 140°F) Altitude: up to
humidity: 8% Relative (10,000ft) BTUs/hour - Operating 3000m
to 80% Humidity: Noise: 46 dBA 4380 (3000 humidity: 20% Acoustic noise:
Noise: 6 Bels 20% - 80% - typical) to 80% relative Less than 7.1B
Altitude: 0 - Operating humidity, sound power in
1,500m Temperature noncondensing ambient
- 5 to 35 Non-operating temperature of
degrees C humidity: 5% to up to 27° C
Operating 95% relative
relative humidity,
Humidity - noncondensing
15% to 80%
non
condensing
Operating
Altitude
above sea
level - 3KM
(10,000
feet)
Reliability & ECC on system ECC memory ECC Memory ECC ECC memory LED indicators
Servicability memory and Redundant and cache Memory, and cache Hot for power, fans,
L2 cache Hot Power supply Hot-Swap Redundant swap hard and disks
swap disk Redundant disks, power Hot-swap drives Hot-pluggable
drives and PCI fans supplies and fans and Redundant hot disk drives
slots PCI Redundant fans Auto power, swap power Redundant
extended error hot reboot Thermal hot-plug supplies power
handling Disk swappable Management disks, Hot-plug power
drive fault disk drives Remote system parallel subsystems
tracking and management SCSI PCI Front-accessible
warning Redundant buses drives
Optional hot-plug power
redundant
power and
cooling CPU
de-allocation
Service
processor
Memory error
correction
extensions
System Electronic eXtended Insight HP Secure Sun Advanced
Management Service Agent System Manager: Web Console Management Lights Out
- integrated Control Server/network - Allows Center, Sun Management
system Facility software multiple Remote System (ALOM) -
environmental (XSCF) - management (maximum Control, Sun Monitors and
monitoring monitors utility, consists of four) Cluster, Sun PC reports system
and alerting processors, of a Windows operators in NetLink, and component
which includes temperature, based console different Solstice status. Allows
voltage, fan power supply application and remote JumpStart, remote
speed and and fans server based locations to Solaris management
temperature Remote management manage the WebStart, via network or
sensing. Cabinet data collection server using Solstice serial
Allows Interface agents. standard AdminSuite, connection.
programmable (RCI) - Monitors over Netscape Solstice System
re-booting monitoring of 1,000 Internet DiskSuite, Configuration
after power all functions parameters, browser Solstice Card (SCC) -
loss, hardware remotely including software. Backup, and contains the
checkstop systems health, This is other Solstice systems Host
failure, configuration achieved via products ID, MAC
machine check and password address and
interrupt or performance encrypted NVRAM
operating Remote Server console settings. Sun
system hang Management: access. HP ONE Web
or failure. Integrated Web QoS Server 6 SP5
remote (Quality of (60 days try &
management Service) - buy) Sun ONE
console (RMC) Allows Application
monitors consistent Server 7,
system power, response Platform
temperature times Edition Sun
and fans. irrespective ONE
Capable of of load Application
performing levels. Server 7,
system halt, Balances Standard
reset or power server loads Edition (60
on/off by directing days try & buy)
functions. requests Sun ONE
away from Messaging
the most Server 5.2 SP1
utilised local (free for the
or remote first 200
servers. mailboxes) Sun
Web QoS ONE Calendar
supports Server 5.1.1
both Apache Sun ONE
and Instant
Netscape Collaboration
Web Pack 3.0.1
Servers. Hp (free for the
Ignite/UX - first 200
Allows mailboxes) Sun
replication ONE Directory
of HP-UX Server 5.1
installation (free license for
from single 200K entries)
server to Sun ONE Active
multiple Server Pages
servers. v3.6.2 Sun ONE
Studio 4,
update 1
Capacity On No No No No No
Demand
Clustering Yes - Cluster Yes Yes Yes
1600
p630 6E4 及其竞争产品特性对比表
IBM - eServer HP - AlphaServer HP - AlphaServer HP - hp server Sun - Fire
pSeries 630 ES40 ES45 rp5470 V480 Server
Model 6E4
Product Type Entry-Level Entry-Level Entry-Level Entry-Level Entry-Level
Server Server Server Server Server
Architecture RISC RISC RISC RISC RISC
Platform UNIX, LINUX UNIX, LINUX, UNIX, LINUX, UNIX UNIX
Other OS Other OS
Form Factor Tower Rack, Tower Rack, Tower Rack, Tower Rack, Tower
Manufacturer IBM Corp. Hewlett Packard Hewlett Packard Hewlett Packard Sun
Microsystems
Announced 25-Jun-02 07-Apr-99 16-Oct-01 28-Nov-00 19-Jun-02
CPU POWER4+ Alpha 21264A Alpha 21264C PA-8700+ UItraSPARC-III
(1.2GHz), (833MHz) (1GHz), Alpha (875MHz), Cu (900MHz)
POWER4+ 21264D PA-8700
(1.45GHz), (1.25GHz) (750MHz)
POWER4
(1GHz)
Max CPUs 4 4 4 4 4
Cache 1.44MB L2, 8MB L2 8MB, 16MB L2 2.25MB 8MB L2
8-32MB DDR
L3/processor
card
Memory 1 0.5 1 0.5 4
Minimum (GB)
Memory 32 32 32 16 32
Maximum
(GB)
Memory 1GB (4 x 512MB (4 x 512MB (4 x 512MB, 1GB, 1GB (4 x
Options 256MB), 2GB 128MB), 1GB (4 128MB), 1GB (4 2GB ECC SDRAM 256MB), 2GB
(4 x 512MB), x 256MB), 2GB x 256MB), 2GB (4 x 512MB),
4GB (4 x 1GB), (4 x 512MB), (4 x 512MB), 4GB (4 x 1GB)
8GB (4 x 2GB) 4GB (4 x 1GB) 4GB (4 x 1GB) SDRAM DIMMs
ECC DDR 125MHz ECC ECC SDRAM
SDRAM DIMM SDRAM DIMM DIMM kits
kits kits
Storage 18 18 18 36 36
Minimum (GB)
Storage Max 587 1752 1752 584 146
Int (GB)
Storage 18.2GB, 18.2GB, 36.4GB, 36.4GB, 72.8GB, 36GB, 73GB 36GB, 73GB
Options 36.4GB, 72.8GB, 146GB 146GB Ultra320 Ultra320 SCSI FC-AL
73.4GB, Ultra320 SCSI SCSI 10,000rpm 15,000rpm 10,000rpm 1"
146.8GB 10,000rpm 1" 1" 18.2GB, 146GB Ultra320 hot swap
Ultra3 SCSI 18.2GB, 36.4GB 36.4GB, 72.8GB SCSI 10,000rpm
10,000rpm hot Ultra320 SCSI Ultra320 SCSI
swap 36.4GB, 15,000rpm 1" 15,000rpm 1"
73.4GB Ultra3
SCSI
15,000rpm hot
swap
Bus PCI/PCI-X PCI PCI/AGP PCI PCI
Technology
I/O Notes 6 x 6 x 64-bit PCI 2 x 64-bit PCI slots 2 x 64-bit
64-bit/133MHz slots (Model 1) 64-bit/66MHz, 1 66MHz 3.3V 4
(3.3 V) hot 10 x 64-bit PCI x 64-bit/33MHz, x 64-bit 33MHz
swappable slots (Model 2) 1 x AGP (Model 5V
slots 1) 3 x
64-bit/66MHz, 1
x 64bit/33MHz
(Model 2) 1 x
64-bit/66MHz, 3
x 64-bit/33MHz
(Model 3)
Max Slots 6 10 10 10 6
Std Slots 4 6 6 10 6
Operating AIX, Linux Tru64 Unix; Tru64 Unix; HP-UX Solaris
System OpenVMS; Linux OpenVMS; Linux
Rack Units 8 8 7 5
Total Bays 6 15 16 4 3
Physical Enclosure Enclosure Enclosure Enclosure Enclosure
Characteristics - Dimensions - Dimensions (H - Dimensions (H - Dimensions (H - Dimensions
(H x W x D): x W x D): 35.2 x W x D): 35.2 x W x D): 31.1 (H x W x D):
53 x 30 x 72.5 (8U) x 44.7 x (8U) x 44.7 x (7U) x 48.2 x 22.2(5U) x
cm 76.5 78.2 77.5 cm 44.6 x 61.0 cm
- Weight: 51 (rackmount) cm (rackmount) cm - Weight: 68 kg - Weight: 44
kg (maximum) - Weight: 50 kg - Weight: 92 - Heat: 4380 Max. kg
kg - Heat: 3074 (rackmount BTU/hr
- Heat: 2,540 BTU/hr max) kg
BTU/hr - Heat: 8196
(maximum) BTU/hr
(rackmount
max)
Site Planning Power: 100 to Power Supply - Power: 200-240 AC Input Power - Power: 100 -
127 volts or tower / pedestal VAC, 50/60Hz 100-240V 50/60 240 VAC, 47 -
200 to 240 / rack Operating Hz 63Hz
volts AC, Nominal Voltage temperature: Typical and Maximum AC
50/60 Hz Range: 100 VAC 10° to 35° C Maximum power input: 1440 W
Temperature: / 120 VAC / (50° to 95° F) - 880W and per power
5° to 35°C 220-240 VAC Operating 1283W supply
(41° to 95°F) Operating Humidity: 20% Maximum heat Maximum DC
Relative Voltage Range: to 80% BTUs/hour - output: 1184
humidity: 8% 90-112 VAC / (noncondensing) 4380 (3000 - W per power
to 80% 112-228 VAC / Maximum typical) supply
Noise: 6.0 Bels 180-265 VAC Altitude: 3084m Operating Operating
Operating Power Source (10,000 ft) Temperature - 5 Temp: 5° - 35°
phase: Single / Noise: 47 dBA to 35 degrees C (41° - 95°F)
Single / Single (bystander Operating Operating
Nominal position) relative Humidity humidity: 20%
frequency: - 15% to 80% - 80% relative
50-60 Hz / 60 Hz non condensing temperature
/ 50-60 Hz Operating
Frequency Altitude above
range: 49-51, sea level - 3KM
59-61 Hz / (10,000 feet)
59-61 Hz /
49-51, 59-61 Hz
Temperature
Operating: 10 to
40 C (10 to 35
rack)
Nonoperating:
-40 to 66 C
Humidity
(noncondensing)
Operating: 20%
to 80%
Nonoperating:
10% to 95%
Maximum
Altitude
(unpressurized)
Operating: 2
10,000 ft /
3048m
Nonoperating:
40,000 ft /
12192m
Reliability & ECC on Auto reboot, Redundant fans N+1 hotswap LED indicators
Servicability memory, L1 thermal and power cooling Two hot for power,
and L2 cache management, supplies Hot swap power fans, and disks
Hot swappable remote system swappable fans, supplies standard Hot-pluggable
disk drives and management, power supplies, - optional 3rd disk drives Two
PCI-X slots RAID, hot swap disks and PCI power supply for hot-swap
Disk drive fault drives, memory slots CPU cache N+1 protection (N+1) power
tracking and failover, ECC parity protection On-line memory supplies
warning AIX memory, ECC ECC cache and page deallocation Front-to-back
log facility (to cache, ECC memory ECC protected cooling
record and log system bus, SMP SyncDRAM Automatic
hardware and CPU failover, memory Full System
software error logging, parity protection Recovery
failures) hot-swap of data and (ASR) Remote
Redundancy redundant address buses System
for Array power and On-chip CPU Control (RSC)
Self-Healing cooling, optional cache with ECC Alternate
Optional UPS. Also with protection multipathing
redundant rackmount: Dynamic support to
power and multiple processor external
cooling CPU systems, resilience and storage and
de-allocation multiple power deallocation networks for
Service sources, On-line addition increased
processor dual-ported and replacement availability
Environmental storage of PCI I/O cards
Monitoring of UPS power
temperature, management Hot
fans and plug internal
voltage Online disks Two
diagnostics independent
and UltraSCSI buses
Auto-restart to internal disks
for mirroring
across disks and
controllers
Journal file
system Auto
reboot
MC/ServiceGuard
and
MC/LockManager
support On-line
diagnostics and
system health
monitor
System Electronic DIGITAL Insight Manager Event Sun
Management Service Agent ServerWORKS - server/network Notification, Management
- monitors and Manager; management Event Monitoring Centre Sun
analyzes integrated software tool. Service, Remote
system errors system and Consists of a Extended Fault System
network Windows based Management Control Solaris
software tools, cosole System, System Management
which provides application and Platform Monitor, Console
"out-of-the-box" server or client Built-in Web Solstice
network and based Console, ASCII AdminSuite
server management Consoles, Solstice
management, data collection Remote Access, DiskSuite
provides agents. Monitors Self-Diagnosis,
automatic health, Online and
monitoring of configuration Offline
LAN and and Diagnostics, LAN
AlphaServers, performance Console
remote paging, data Remote Management is
and agents for a Server via a 10 Base-T
variety of Management - Port
operating Integrated
systems, remote
SNMP-compliant management
(Simple Network console (RMC)
Management monitors system
Protocol), for power,
monitoring and temperature and
management of fans as well as
hardware from reset, halt and
non-Digital power on/off
vendors, Using activities
SNMP for
Windows NT,
Digital UNIX,
and OpenVMS,
SNMP agents
can acquire and
present critical
server
information such
as system and
network status,
I/O information,
storage, and
disk activities.
Capacity On No No Yes No
Demand
Clustering Cluster 1300 Yes Yes Yes
and 1600
p630 6C4 及其竞争产品特性对比表
IBM - eServer HP - AlphaServer HP - AlphaServer HP - HP - hp server Sun - Fire
pSeries 630 ES40 ES45 AlphaServer rp5470 V480 Server
Model 6C4 ES47
Product Type Entry-Level Entry-Level Entry-Level Entry-Level Entry-Level Entry-Level
Server Server Server Server Server Server
Architecture RISC RISC RISC RISC RISC RISC
Platform UNIX, LINUX UNIX, LINUX, UNIX, LINUX, UNIX, Other UNIX UNIX
Other OS Other OS OS
Form Factor Rack Rack, Tower Rack, Tower Rack, Tower Rack, Tower Rack, Tower
Manufacturer IBM Corp. Hewlett Packard Hewlett Packard Hewlett Hewlett Packard Sun
Packard Microsystems
Announced 26-Jun-02 07-Apr-99 16-Oct-01 20-Jan-03 28-Nov-00 19-Jun-02
CPU POWER4+ Alpha 21264A Alpha 21264C Alpha 21364 PA-8700+ UItraSPARC-III
(1.2GHz), (833MHz) (1GHz), Alpha (1GHz) (875MHz), Cu (900MHz)
POWER4+ 21264D PA-8700
(1.45GHz), (1.25GHz) (750MHz)
POWER4
(1GHz)
Max CPUs 4 4 4 4 4 4
Cache 1.44MB L2, 8MB L2 8MB, 16MB L2 1.75MB ECC 2.25MB 8MB L2
8-32MB DDR L2 per CPU
L3/processor
card
Memory 1 0.5 1 1 0.5 4
Minimum (GB)
Memory 32 32 32 16 16 32
Maximum
(GB)
Memory 1GB (4 x 512MB (4 x 512MB (4 x 512MB (4 x 512MB, 1GB, 1GB (4 x
Options 256MB), 2GB 128MB), 1GB (4 128MB), 1GB (4 128MB), 1GB 2GB ECC SDRAM 256MB), 2GB
(4 x 512MB), x 256MB), 2GB x 256MB), 2GB (4 x 256MB), (4 x 512MB),
4GB (4 x (4 x 512MB), (4 x 512MB), 2GB (4 x 4GB (4 x 1GB)
1GB) , 8GB (4 4GB (4 x 1GB) 4GB (4 x 1GB) 512MB) SDRAM DIMMs
x 4GB) ECC 125MHz ECC ECC SDRAM RDRAM
DDR SDRAM SDRAM DIMM DIMM kits DIMM kits
DIMM kits kits 512MB (1 x
128MB), 1GB
(1 x 256MB),
2GB (1 x
512MB)
RDRAM RAID
options
Storage 18 18 18 18 36 36
Minimum (GB)
Storage Max 587 1752 1752 584 584 146
Int (GB)
Storage 18.2GB, 18.2GB, 36.4GB, 36.4GB, 72.8GB, 36.4GB, 36GB, 73GB 36GB, 73GB
Options 36.4GB, 72.8GB, 146GB 146GB Ultra320 72.8GB, Ultra320 SCSI FC-AL
73.4GB, Ultra320 SCSI SCSI 10,000rpm 146GB 15,000rpm 10,000rpm 1"
146.8GB 10,000rpm 1" 1" 18.2GB, Ultra320 146GB Ultra320 hot swap
Ultra3 SCSI 18.2GB, 36.4GB 36.4GB, 72.8GB SCSI SCSI 10,000rpm
10,000rpm hot Ultra320 SCSI Ultra320 SCSI 10,000rpm
swappable 15,000rpm 1" 15,000rpm 1" 18.2GB,
36.4GB, 36.4GB,
73.4GB Ultra3 72.8GB
SCSI Ultra320
15,000rpm hot SCSI
swap 15,000rpm
Bus PCI-X PCI PCI/AGP PCI-X/AGP PCI PCI
Technology
I/O Notes 6 x 6 x 64-bit PCI 2 x 1 x 64-bit 64-bit PCI slots 2 x 64-bit
64-bit/133MHz slots (Model 1) 64-bit/66MHz, 1 133MHz slot 66MHz 3.3V 4
(3.3 V) hot 10 x 64-bit PCI x 64-bit/33MHz, 4 x 64-bit x 64-bit 33MHz
swappable slots (Model 2) 1 x AGP (Model 66MHz slots 5V
slots 1) 3 x 1 x AGP slot
64-bit/66MHz, 1 Up to 32 PCI
x 64bit/33MHz slots with I/O
(Model 2) 1 x expansion
64-bit/66MHz, 3
x 64-bit/33MHz
(Model 3)
Max Slots 20 10 10 32 10 6
Std Slots 4 6 6 6 10 6
Operating AIX, Linux Tru64 Unix; Tru64 Unix; Tru64 Unix; HP-UX Solaris
System OpenVMS; Linux OpenVMS; Linux OpenVMS
Rack Units 4 8 8 4 7 5
Total Bays 4 15 16 5 4 3
Physical Enclosure Enclosure Enclosure Enclosure Enclosure Enclosure
Characteristics - Dimensions - Dimensions (H - Dimensions (H - Dimensions - Dimensions (H - Dimensions
(H x W x D): x W x D): 35.2 x W x D): 35.2 (H x W x D): x W x D): 31.1 (H x W x D):
17.3 (4U) x (8U) x 44.7 x (8U) x 44.7 x 15 x 44.5 x (7U) x 48.2 x 22.2(5U) x
44.4 x 60.9 cm 76.5 78.2 86 77.5 cm 44.6 x 61.0 cm
- Weight: (rackmount) cm (rackmount) cm (rackmount - Weight: 68 kg - Weight: 44
47.3kg - Weight: 50 kg - Weight: 92 drawer) cm - Heat: 4380 Max. kg
(maximum) kg - Heat: 3074 (rackmount - Weight: BTU/hr
- Heat: 2,540 BTU/hr max) kg 320 kg
BTU/hr - Heat: 8196 - Heat:
(maximum) BTU/hr 13,174
(rackmount BTU/hr
max) (rackmount
max)
Site Planning Power: 100 to Power Supply - Power: 200-240 Power: 208V AC Input Power - Power: 100 -
127 volts or tower / pedestal VAC, 50/60Hz (700 Watt @ 100-240V 50/60 240 VAC, 47 -
200 to 240 / rack Operating 120V), Hz 63Hz
volts AC, Nominal Voltage temperature: 50/60Hz Typical and Maximum AC
50/60 Hz Range: 100 VAC 10° to 35° C Operating Maximum power input: 1440 W
Temperature: / 120 VAC / (50° to 95° F) temperature: - 880W and per power
5° to 35°C 220-240 VAC Operating 10° to 40° C 1283W supply
(41° to 95°F) Operating Humidity: 20% (50° to 95° Maximum heat Maximum DC
Relative Voltage Range: to 80% F) BTUs/hour - output: 1184
humidity: 8% 90-112 VAC / (noncondensing) Operating 4380 (3000 - W per power
to 80% 112-228 VAC / Maximum Humidity: typical) supply
Noise: 6.0 Bels 180-265 VAC Altitude: 3084m 20% to 80% Operating Operating
Operating Power Source (10,000 ft) Maximum Temperature - 5 Temp: 5° - 35°
phase: Single / Noise: 47 dBA Altitude: to 35 degrees C (41° - 95°F)
Single / Single (bystander 3084m Operating Operating
Nominal position) (10,000 ft) relative Humidity humidity: 20%
frequency: Vibration: 01 - 15% to 80% - 80% relative
50-60 Hz / 60 Hz to 500Hz non condensing temperature
/ 50-60 Hz 0.1G peak Operating
Frequency Altitude above
range: 49-51, sea level - 3KM
59-61 Hz / (10,000 feet)
59-61 Hz /
49-51, 59-61 Hz
Temperature
Operating: 10 to
40 C (10 to 35
rack)
Nonoperating:
-40 to 66 C
Humidity
(noncondensing)
Operating: 20%
to 80%
Nonoperating:
10% to 95%
Maximum
Altitude
(unpressurized)
Operating: 2
10,000 ft /
3048m
Nonoperating:
40,000 ft /
12192m
Reliability & ECC on Auto reboot, Redundant fans Redundant N+1 hotswap LED indicators
Servicability memory, L1 thermal and power hot cooling Two hot for power,
and L2 cache management, supplies Hot pluggable swap power fans, and disks
Hot swappable remote system swappable fans, fans and supplies standard Hot-pluggable
disk drives and management, power supplies, power - optional 3rd disk drives Two
PCI-X slots RAID, hot swap disks and PCI supplies CPU power supply for hot-swap
Disk drive fault drives, memory slots CPU cache cache parity N+1 protection (N+1) power
tracking and failover, ECC parity protection protection On-line memory supplies
warning AIX memory, ECC ECC cache and ECC cache page deallocation Front-to-back
log facility (to cache, ECC memory and memory ECC protected cooling
record and log system bus, SMP SyncDRAM Automatic
hardware and CPU failover, memory Full System
software error logging, parity protection Recovery
failures) hot-swap of data and (ASR) Remote
Redundancy redundant address buses System
for Array power and On-chip CPU Control (RSC)
Self-Healing cooling, optional cache with ECC Alternate
Optional UPS. Also with protection multipathing
redundant rackmount: Dynamic support to
power and multiple processor external
cooling CPU systems, resilience and storage and
de-allocation multiple power deallocation networks for
Service sources, On-line addition increased
processor dual-ported and replacement availability
Environmental storage of PCI I/O cards
Monitoring of UPS power
temperature, management Hot
fans and plug internal
voltage Online disks Two
diagnostics independent
and UltraSCSI buses
Auto-restart to internal disks
for mirroring
across disks and
controllers
Journal file
system Auto
reboot
MC/ServiceGuard
and
MC/LockManager
support On-line
diagnostics and
system health
monitor
System Electronic DIGITAL Insight Manager AlphaServer Event Sun
Management Service Agent ServerWORKS - server/network Management Notification, Management
- monitors and Manager; management Utility Event Monitoring Centre Sun
analyzes integrated software tool. Service, Remote
system errors system and Consists of a Extended Fault System
network Windows based Management Control Solaris
software tools, cosole System, System Management
which provides application and Platform Monitor, Console
"out-of-the-box" server or client Built-in Web Solstice
network and based Console, ASCII AdminSuite
server management Consoles, Solstice
management, data collection Remote Access, DiskSuite
provides agents. Monitors Self-Diagnosis,
automatic health, Online and
monitoring of configuration Offline
LAN and and Diagnostics, LAN
AlphaServers, performance Console
remote paging, data Remote Management is
and agents for a Server via a 10 Base-T
variety of Management - Port
operating Integrated
systems, remote
SNMP-compliant management
(Simple Network console (RMC)
Management monitors system
Protocol), for power,
monitoring and temperature and
management of fans as well as
hardware from reset, halt and
non-Digital power on/off
vendors, Using activities
SNMP for
Windows NT,
Digital UNIX,
and OpenVMS,
SNMP agents
can acquire and
present critical
server
information such
as system and
network status,
I/O information,
storage, and
disk activities.
Capacity On No No Yes Yes No
Demand
Clustering Cluster 1300 Yes Yes Yes Yes
and 1600
p650 及其竞争产品特性对比表
IBM - HP - AlphaServer HP - hp server rp7410 Sun - Fire Sun - Fire 3800
eServer ES80 V880 Server Server
pSeries 650
Product Type Mid-Range Mid-Range Mid-Range Server Mid-Range Mid-Range
Server Server Server Server
Architecture RISC RISC RISC RISC RISC
Platform UNIX, LINUX UNIX, Other OS UNIX UNIX UNIX
Form Factor Rack Enclosure Rack Rack Rack, Tower
Manufacturer IBM Corp. Hewlett Packard Hewlett Packard Sun Sun
Microsystems Microsystems
Announced 11-Nov-02 20-Jan-03 25-Feb-02 29-Oct-01 21-Mar-01
CPU POWER4+ Alpha 21364 PA-8700 (750MHz), UItraSPARC-III UItraSPARC-III
(1.45GHz), (1GHz) PA-8700+ (875MHz), Cu (900MHz), Cu (900MHz),
POWER4+ PA-8700 (650MHz) UItraSPARC-III UItraSPARC-III
(1.2GHz) Cu (1.05GHz) Cu (1.05GHz)
Max CPUs 8 8 8 8 8
Cache 1.5MB L2 1.75MB ECC L2 2.25MB on chip 8MB L2 8MB L2
per 2 CPUs, cache per CPU
8MB or
32MB L3
Memory 2 0.5 1 4 2
Minimum (GB)
Memory 64 32 32 64 64
Maximum
(GB)
Memory 2GB (4 x 512MB (4 x 1GB (4 x 256MB), 2GB 1GB (4 x 1GB, 2GB, 4GB
Options 512MB), 128MB), 1GB (4 (4 x 512MB), 4GB (4 x 256MB), 2GB ECC SDRAM
4GB (4 x x 256MB), 2GB 1GB) ECC SDRAM kits (4 x 512MB), DIMMs
1GB), 8GB (4 x 512MB) 4GB (4 x 1GB)
(4 x 2GB) RDRAM kits SDRAM DIMMs
DDR SDRAM 512MB (1 x
DIMMs with 128MB), 1GB (1
Chipkill x 256MB), 2GB
(1 x 512MB)
RDRAM RAID
options
Storage 36 18 36 36
Minimum (GB)
Storage Max 587 1168 584 876
Int (GB)
Storage 36.4GB, 36.4GB, 72.8GB, 36GB, 73GB Ultra320 36.4GB, 73GB External storage
Options 73.4GB, 146GB Ultra320 SCSI 15,000rpm hot 1" 10,000rpm via D240 Media
146.8GB SCSI 10,000rpm swap 146GB Ultra320 FC-AL drive Trays
Ultra3 SCSI 18.2GB, 36.4GB, SCSI 10,000rpm hot
10,000rpm 72.8GB Ultra320 swap
hot-swap SCSI 15,000rpm
36.4GB,
73.4GB
Ultra3 SCSI
15,000rpm
hot swap
Bus PCI-X PCI-X, AGP PCI PCI cPCI
Technology
I/O Notes 6 x 64-bit Up to 5 x 64-bit 14 x 4X 66MHz 64-bit 2 x 64-bit 4 x 66MHz cPCI
full-length PCI-X slots per twin turbo hot plug PCI 66MHz slots 8 x 33MHz
hot swap SBB 1 x AGP per slots 2 x 4X 66MHz hot-swap PCI cPCI slots
PCI-X slots 1 SBB 64-bit turbo hot plug slots 7 x 64-bit
x 32-bit PCI slots 33MHz
half-length hot-swap PCI
hot swap slots
PCI-X slot
48
additional
PCI-X/PCI
slots
available via
8 x I/O
drawers,
each with 6
PCI slots
Max Slots 63 64 16 9 12
Std Slots 7 6 7 9 12
Operating AIX 5L, Tru64 Unix; HP-UX Solaris Solaris 8
System Linux OpenVMS; Linux
Rack Units 8 41 10 17 9
Total Bays 7 9 5 15
Physical Enclosure Enclosure Enclosure Enclosure Enclosure
Characteristics - - Dimensions (H - Dimensions (H x W x - Dimensions - Dimensions (H
Dimensions x W x D): 200 D): 44.5 (10U) x 48.3 x (H x W x D): x W x D): 38.1 x
(H x W x D): (41U) x 60 x 120 76.2 cm 71.4 x 48.0 x 45.0 x 88.4 cm
35.1 (8U) x cm - Weight: 99.8 kg 83.6 cm - Weight: 90.7
44.5 x 76.0 - Weight: (max) - Weight: kg
cm 320 kg 130.9 max kg
- Weight: 93 - Heat: 12204
kg BTU/hr (max)
- Heat: 5461
BTU/hr
(maximum)
Site Planning Power - Power: 200-240 Power: 200-240V AC, Maximum AC Power: 100 VAC
1,070watts VAC, 50/60Hz 50/60Hz Output: (47-63Hz) at 24
(typical) Operating Temperature: 5° to 35° 1500W Amp or 120 VAC
1,600watts temperature: C (41° to 95° F) Maximum DC (47-63Hz) at
(maximum) 10° to 40° C Humidity: 15% to 80% Output: 19.7 Amp or
Operating (50° to 95° F) Noise: 8.1 Bels LwA 1100W 200-240 VAC
Voltage - Operating (max) AC Power: (47-63Hz) at
200 to 240 Humidity: 20% 100-240 VAC, 11.4 Amp
VAC to 80% 47-63Hz, Operating
Operating (noncondensing) 1.48KVA temperature: 5°
Frequency - Maximum Operating C to 35° C (41°
50/60Hz Altitude: 3084m Temperature: F to 95° F)
Temperature (10,000 ft) 5°C to 35°C Non-operating
- 10° C to Noise: 54 dBA Operating temperature:
38° C (bystander Humidity: 20% -20° C to 60° C
Relative position) to 80% (-4° F to 140° F)
humidity - relative, Operating
8% to 80% noncondensing humidity: 20%
Noise: 6.1 Non-operating to 80% relative
Bel Temperature: humidity,
(operating) -20°C to 60°C noncondensing
Non-operating Non-operating
Humidity: 5% humidity: 5% to
to 93% 93% relative
relative, humidity,
noncondensing noncondensing
Reliability & ECC ChipKill ECC protected Hot swap disk drives Hot swap Dynamic
Servicability memory memory, Hot pluggable PCI slots power System
Memory processor cache Hot-plug cell boards supplies, fans, Domains,
scrubbing and system data Hot spare CPU with disk drives, Dynamic
and paths Optional instant capacity on PCI slots Reconfiguration,
redundant RAID memory demand (iCOD) Cooling fans ECC memory
bit-steering support N+1 Dynamic CPU and trays Online and cache, Hot
Hot swap Voltage memory upgrades swap cPCI,
PCI-X, disk Regulator allocation/de-allocation Concurrent Redundant
drives Modules N+1 hot-swappable maintenance CPU/memory
PCI-X/PCI Hot-swap fans 2N hot swappable Multi-pathing boards, I/O
bus parity redundant power supplies Remote assemblies,
error power supplies Self-healing cache System Fireplane
recovery, and fans Chip-sparing memory Control (RSC) interconnect,
bus and slot technology ECC Automatic system clock,
deallocation memory, cache and I/O System system
Redundant paths Hardware Recovery controller
hot swap partitions with failover (ASR) boards, power
power functionality and cooling
supplies
Redundant
hot swap
cooling Disk
mirroring
RAID 1
System Service Solstice Dynamic
Management processor DiskSuite System
Service Solaris PC Domains,
agent and NetLink Solaris
inventory Solstice Resource
scout JumpStart Manager, Solaris
Predictive Solaris Bandwidth
Failure WebStart Manager, Solaris
Analysis Solstice Web Start,
(PFA) AdminSuite Solstice
Dynamic Solstice AdminSuite,
error Backup Veritas Solstice Domain
recovery Volume Manager,
Auto-reboot Manager Solstice
Software Sun Enterprise
Management Manager,
Center Sun Solstice
Remote DiskSuite,
System Solstice Backup,
Control Sun VERTAS File
Cluster System Veritas,
Volume
Manager, Sun
Cluster, Sun
HPC
ClusterTools
Capacity On Yes - Yes Yes No Yes
Demand Processors
and memory
Clustering Cluster 1600 Yes Yes Yes
p670 及其竞争产品特性对比表
IBM - eServer HP - AlphaServer HP - HP - hp server Sun - Fire 6800 Sun - Fire 12K
pSeries 670 GS160 AlphaServer rp8400 Server Server
GS1280
Product Type Mid-Range Mid-Range Server High-End Mid-Range High-End Server High-End Server
Server Server Server
Architecture RISC RISC RISC RISC RISC RISC
Platform UNIX UNIX, LINUX, UNIX, Other UNIX UNIX UNIX
Other OS OS
Form Factor Enclosure Enclosure Enclosure Rack Enclosure Enclosure
Manufacturer IBM Corp. Hewlett Packard Hewlett Hewlett Packard Sun Sun
Packard Microsystems Microsystems
Announced 08-Apr-02 16-May-00 20-Jan-03 18-Sep-01 21-Mar-01 09-Apr-02
CPU POWER4 Alpha 21264C Alpha 21364 PA-8700 UItraSPARC-III UItraSPARC-III
(1.1GHz), (1.224GHz) (1.15GHz) (650MHz), Cu (1.2GHz), Cu (1.2GHz),
POWER4+ PA-8700 UItraSPARC-III UItraSPARC-III
(1.5GHz) (750MHz), Cu (1.05GHz), Cu (1.05GHz),
PA-8700+ UItraSPARC-III UItraSPARC-III
(875MHz) Cu (900MHz) Cu (900MHz)
Max CPUs 16 16 16 16 24 52
Cache 5.6MB L2 per 16MB ECC 1.75MB ECC 750KB inst / 8MB L2 8MB per CPU
MCM, 128MB on-board per CPU L2 cache per 1.5MB data
L3 CPU
Memory 4 1 1 2 2 4
Minimum (GB)
Memory 256 128 64 64 192 288
Maximum
(GB)
Memory 4GB, 8GB, 512MB, 1GB, 512MB (4 x 1GB (4 x 256MB) 1GB, 2GB, 4GB 1GB (4 x
Options 16GB, 32GB, 2GB, 4GB ECC 128MB), 1GB 2GB (4 x ECC SDRAM 256MB), 2GB (4
64GB ECC memory (4 x 256MB), 512MB), 4GB (4 DIMMs x 512MB), 4GB
DDR memory 2GB (4 x x 1GB) ECC (4 x 1GB)
cards 512MB) SDRAM DIMM SDRAM DIMM
RDRAM kits kits kits
512MB (1 x
128MB), 1GB
(1 x 256MB),
2GB (1 x
512MB)
RDRAM RAID
options
Storage 36 18 18 36
Minimum (GB)
Storage Max 7046 2044 1168 584
Int (GB)
Storage 18.2GB, 36.4GB, 72.8GB, 36.4GB, 36GB, 73GB External storage 120+ terabytes
Options 36.4GB, 146GB Ultra320 72.8GB, Ultra320 SCSI via D240 Media direct connect
73.4GB, SCSI 10,000rpm 146GB 15,000rpm 1" Trays storage - Fibre
146.8GB 18.2GB, 36.4, Ultra320 hot swap 146GB Channel (1GB
Ultra3 SCSI 72.8GB Ultra320 SCSI Ultra320 SCSI and 2GB) and
10,000rpm SCSI 15,000rpm 10,000rpm 10,000rpm 1" Ultra SCSI Sun
hot swap 18.2GB, hot swap StorEdge 9900,
36.4GB, 36.4GB, 6900, 3900, T3,
73.4GB 72.8GB A5200, S1,
Ultra3 SCSI Ultra320 D1000 and tape
15,000rpm SCSI devices.
hot swap 15,000rpm
Bus PCI PCI PCI/PCI-X, PCI PCI, cPCI PCI
Technology AGP
I/O Notes 6 x 56 x 64-bit Master I/O 14 x twin turbo 8 x 66MHz PCI + 18 x 66MHz
64-bit/33MHz 33MHz PCI drawer = 10 slots (532 MB/s), 24 x 33MHz PCI hot-swap PCI
(5V) per (Model 8) 112 x x PCI/PCI-X 2 x turbo slots or 8 x 66MHz slots, 18 x
drawer 14 x 64-bit 33MHz PCI + 1 x AGP (266 MB/s) cPCI + 8 x 33MHz
64-bit/66MHz (Model 16) Expansion 33MHz cPCI hot-swap PCI
(3.3V) per I/O drawer = slots
drawer 11 x
PCI/PCI-X +
1 x AGP
Max Slots 60 112 65 16 32 36
Std Slots 10 56 11 8 16 4
Operating AIX 5L Tru64 Unix; Tru64 Unix; HP-UX 11i Solaris 8 Solaris
System OpenVMS; Linux OpenVMS;
Linux
Rack Units 30 41 17 28
Total Bays 48 15 8 6
Physical Enclosure Enclosure Enclosure Enclosure Enclosure Enclosure
Characteristics - Dimensions - Dimensions (H x - Dimensions - Dimensions (H - Dimensions (H - Dimensions (H
(H x W x D): W x D): 170 x (H x W x D): x W x D): 75.56 x x W x D): 190.5 x W x D): 191.0
202 x 79 x 140 x 100 cm 200 x 60 x 48.26 x 76.2 cm (28U) x 61 x x 85.0 x 166.0
149 cm - Weight: 603 kg 120 cm - Weight: 160.6 134.6 cm cm
- Weight: - Heat: 38,200 - Weight: kg - Weight: 544.3 - Weight: 987
1184 kg Btu/Hr (Max (max) 594 - Heat: 8300 kg max kg
- Heat: config) kg BTU/hr
22,800 - Heat:
BTU/hr (max) 23,243
Btu/hr (max
config.)
Site Planning Power: 200 - Operating Power: AC input power: Power: 200-240 AC Power:
240, 380 - Temperature: 5 3-phase 200/240V 50/60 VAC, 47-63 Hz, 200-240 single
415, 480 V to 35 degrees C power Hz 34 Amp phase VAC,
AC, 50 - (41 to 95 degrees subsystem, Typical power Operating 47-63 Hz
60Hz, 15,400 F) redundant 48 dissipation: 2920 temperature: 5° Operating
watts max Operating Vdc hot swap VA @ 200 VAC C to 35° C (41° Temperature:
Temperature: Humidity: 10% to power Max power F to 95° F) 10 to 35°C (50
16° to 32°C 90% supplies dissipation: 5045 Non-operating to 90°F)
(61° to 90° F) (non-condensing) included VA @ 200 VAC temperature: Relative
Humidity: Power Supply: Noise: 7.4 Temperature: -20° C to 60° C Humidity: 20%
8% - 80% Three phase Bels * Operating: +5 (-4° F to 140° F) to 80%
Noise: 7.9 (N+1 hot-swap Operating to +35°C (30°C Operating Altitude: up to
bels max optional) humidity: 10 @ 10,000 feet) humidity: 20% 3,048m (10,000
sound power, - 90% * Non-operating: to 80% relative ft)
62 dBa max Operating -40 to +70°C humidity,
sound temperature: Relative noncondensing
pressure 41°F - 95°F Humidity Non-operating
(10° - 35°C) * Operating: humidity: 5% to
Maximum 15% to 80% @ 93% relative
altitiude: 40°C humidity,
10,000ft non-condensing noncondensing
(3050m) * Non-operating:
5% to 90%
non-condensing
Maximum
Altitude:
* Operating:
3000 m
* Non-operating:
4500 m
Reliability & Chipkill ECC Auto Reboot, ECC PCI hot plug I/O Dynamic Dynamic
Servicability memory ECC optional protected card slots Hot Reconfiguration, Reconfiguration,
cache redundant power, memry, swap, redundant ECC memory Dynamic
Hot-plug ECC memory and processor power supplies & and cache, Hot System
power supply, cache, hot-swap cache and cooling fans ECC swap cPCI, Domains, Fully
fans and disk and power, system data on all CPU, Redundant redundant
disks SMP CPU failover, paths cache, memory CPU/memory power, cooling,
Hot-plug PCI error logging, Optional and I/O paths boards, I/O hardware,
slots, PCI bus optional battery RAID Hot plug disk assemblies, network &
recovery, PCI back-upand memory drives Hardware Fireplane storage
bus optional UPS. support N+1 partitions (nPars) interconnect, connections,
deallocate, Voltage with failover system clock, Hot swappable
Optional Regulator functionality PCI system capability of all
battery Modules doorbell controller major
backup Hot-swap functionality boards, power components,
Partition fast redundant Console failover and cooling Common LED
re-boot, light power functionality system on all
path service, supplies and Advanced major
Service fans monitoring event components ,
history logs monitoring Online hardware
LPAR system (EMS) upgrades & Hot
support, functionality CPU upgrades,
Processor Sun Fireplane
deallocation, Interconnect,
Soft memory ECC protected
scrubbing, memory,
Redundant E-cache, Built-in
bit steering in hardware
L1 and L2 redundancy,
caches and including I/O,
L2 and L3 power, and
directory cooling,
arrays, Automated
Dynamic bit System
steering for Controller
memory Failover,
modules Memory
Predictive Scrubbing,
Failure Automatic
Analysis System
Recovery
System Hardware Insight Manager, Private LAN HP-UX Workload Dynamic Dynamic
Management Management UPS Power for system management System System
Console Management. monitoring (WLM) software Domains, Domains,
System Focal and MC/ServiceGuard Solaris Solaris
Point - management & Resource Resource
Management Remote MC/LockManager Manager, Solaris Manager, Solaris
software browser cluster software Bandwidth Bandwidth
application based Dual built-in Manager, Solaris Manager, Sun
which runs on management service Web Start, MC 3.0,
the HMC processors Solstice VERITAS
Integrated hp AdminSuite, Volume
webqos peak Solstice Domain Manager 3.1.1,
Partition Manager, VERITAS File
manager Solstice System 3.4, Sun
Integrated hp Enterprise Cluster 3.0
servicecontrol Manager,
manager Solstice
OpenView tools DiskSuite,
suite Solstice Backup,
VERTAS File
System Veritas,
Volume
Manager, Sun
Cluster, Sun
HPC
ClusterTools
Capacity On Yes Yes Yes Yes Yes Yes
Demand
Clustering IBM eServer Yes Yes Yes Yes
Cluster 1600
p690 及其竞争产品特性对比表
IBM - eServer HP - AlphaServer HP - hp 9000 Sun - Fire 12K Sun - Fire 15K Server
pSeries 690 GS320 Superdome Server
Product Type High-End High-End Server High-End High-End Server High-End Server
Server Server
Architecture RISC RISC RISC, 64-bit RISC RISC
Intel
Platform UNIX, LINUX UNIX, LINUX, UNIX, UNIX UNIX
Other OS Windows
Form Factor Enclosure Enclosure Enclosure Enclosure Enclosure
Manufacturer IBM Corp. Hewlett Packard Hewlett Sun Sun Microsystems
Packard Microsystems
Announced 04-Oct-01 16-May-00 12-Sep-00 09-Apr-02 26-Sep-01
CPU POWER4 Alpha 21264C PA-8700+ UItraSPARC-III UItraSPARC-III Cu
(1.3GHz), (1.224GHz) (875MHz), Cu (1.2GHz), (1.05GHz), UItraSPARC-III
POWER4+ PA-8700 UItraSPARC-III Cu (1.2GHz),
(1.5GHz), (750MHz), Cu (1.05GHz), UItraSPARC-III Cu
POWER4+ Itanium 2 UItraSPARC-III (900MHz)
(1.7GHz), (1.5GHz) Cu (900MHz)
POWER4
(1.1GHz)
Max CPUs 32 32 64 52 106
Cache 5.6MB L2 per 16MB ECC 1.5MB or 8MB per CPU 8MB per CPU
MCM, 128MB on-board per CPU 2.25MB
L3
Memory 8 1 2 4 16
Minimum (GB)
Memory 512 256 256 288 576
Maximum
(GB)
Memory 4GB, 8GB, 512MB, 1GB, 2GB (4 x 1GB (4 x 1GB (4 x 256MB), 2GB (4 x
Options 16GB, 32GB, 2GB, 4GB ECC 512MB) ECC 256MB), 2GB (4 512MB), 4GB (4 x 1GB)
64GB memory SDRAM Kit x 512MB), 4GB SDRAM DIMMs
memory (4 x 1GB)
cards ECC SDRAM DIMM
DDR RAM kits
Storage 18 18
Minimum (GB)
Storage Max 18790 2044
Int (GB)
Storage 18.2GB, 36.4GB, 72.8GB, various 120+ terabytes 250+ terabytes direct
Options 36.4GB, 146GB Ultra320 external disk direct connect connect storage - Fibre
73.4GB, SCSI 10,000rpm subsystems storage - Fibre Channel (1GB and 2GB)
146.8GB 18.2GB, 36.4GB, Channel (1GB and Ultra SCSI Sun
Ultra3 SCSI 72.8GB Ultra320 and 2GB) and StorEdge 9900, 6900,
10,000rpm SCSI 15,000rpm Ultra SCSI Sun 3900, T3, A5200, S1,
(1") hot swap StorEdge 9900, D1000 and tape devices.
36.4GB, 6900, 3900, T3,
73.4GB A5200, S1,
Ultra3 SCSI D1000 and tape
15,000rpm devices.
hot swap
Bus PCI PCI PCI PCI PCI
Technology
I/O Notes 6 x 168 x 32 x 18 x 66MHz 36 x 66MHz hot-swap PCI
64-bit/33MHz 64-bit/33MHz PCI 64-bit/33MHz, hot-swap PCI slots, 36 x 33MHz
(5V) per slots (Model 24) 16 x slots, 18 x hgot-swap PCI slots
drawer 14 x 224 x 64-bit/66MHz 33MHz
64-bit/66MHz 64-bit/33MHz PCI (16-way) 64 x hot-swap PCI
(3.3V) per slots (Model 32) 64-bit/33MHz, slots
drawer 32 x
64-bit/66MHz
(32-way) 128
x
64-bit/33MHz,
64 x
64-bit/66MHz
(64-way)
Max Slots 160 224 192 36 72
Std Slots 20 168 48 4 4
Operating AIX, Linux Tru64 Unix; HP-UX 11i, Solaris Solaris
System OpenVMS; Linux Windows
Server 2003
Datacenter
Rack Units 42
Total Bays 128
Physical Enclosure Enclosure Enclosure Enclosure Enclosure
Characteristics - Dimensions - Dimensions (H x - Dimensions - Dimensions (H - Dimensions (H x W x D):
(H x W x D): W x D): 170 x (H x W x D): x W x D): 191.0 191.0 x 85.0 x 166.0 cm
202 x 79 x 200 x 100 cm 196 x 152.4 x x 85.0 x 166.0 - Weight: 1122 fully
144 cm - Weight: 983 kg 122 cm cm configured kg
- Weight: - Heat: 56,000 - Weight: - Weight: 987
1209 kg Btu/hr (max 1196 kg max kg
- Heat: config.) - Heat:
51,200 116,000
BTU/hr
Site Planning Temperature Operating Operating AC Power: AC Power: 200-240 single
- 16 to 32 Temperature: 5 Temperature: 200-240 single phase VAC, 47-63 Hz
degrees C to 35 degrees C 20° to 30°C phase VAC, Operating Temperature:
Relative (41 to 95 degrees Non-operating 47-63 Hz 10° to 35°C (50° to 90°F)
humidity - F) Temperature: Operating Relative Humidity: 20% to
8% to 80% Operating -40°C to Temperature: 80%
Power - Humidity: 10% to -70°C 10 to 35°C (50 Altitude: up to 3,048m
15,400 watts 90% Operating to 90°F) (10,000 ft)
(maximum) (non-condensing) relative Relative
AC Voltage - Power Supply: humidity: Humidity: 20%
200 to 240 Three phase 15% to 80% to 80%
VAC, 380 to (N+1 hot-swap at 30°C Altitude: up to
415 VAC, 480 optional) Non-operating 3,048m (10,000
VAC relative ft)
humidity:
90% at 65°C
Operating
altitude: 0 -
3.1 km
(10,000ft)
Non-operating
altitude: 0 -
4.6 km
(15,000ft)
AC Input
Power:
200-240 VAC,
47-63Hz
Reliability & Chipkill ECC Auto Reboot, On-line Dynamic Dynamic
Servicability memory, optional addition and Reconfiguration, reconfiguration/Automated
Hot-plug redundant power, replacement Dynamic Dynamic Reconfiguration,
power supply, ECC memory and of cells, I/O System Up to 18 Dynamic System
fans and cache, hot-swap backplane and Domains, Fully Domains, Fully redundant
disks, disk and power, I/O cards Hot redundant power, cooling, hardware,
Hot-plug PCI SMP CPU failover, swap power, cooling, network & storage
slots, PCI bus error logging, redundant hardware, connections, Hot
recovery, PCI optional battery fans and network & swappable capability of all
bus back-upand power storage major components, Online
deallocate, optional UPS. supplies Dual connections, upgrade, Concurrent
Battery power source Hot swappable maintenance, ECC
backup, ECC memory capability of all protected memory, Full
Partition fast major data integrity
re-boot, Light components,
path service, Common LED
Service system on all
history logs major
LPAR components ,
support, Online hardware
Redundant upgrades & Hot
Service Focal CPU upgrades,
pt, Processor Sun Fireplane
deallocation, Interconnect,
Soft memory ECC protected
scrubbing, memory,
Redundant E-cache, Built-in
bit steering, hardware
First failure redundancy,
data capture. including I/O,
power, and
cooling,
Automated
System
Controller
Failover,
Memory
Scrubbing,
Automatic
System
Recovery
System Predictive Insight Manager, Support Dynamic Sun's 5th generation
Management Failure UPS Power Management System Dynamic System Domains,
Analyses AIX Management. Station (SMS) Domains, Solaris Resource
diagnostics runs the Solaris Management software,
with error log Superdome Resource Solaris Bandwidth Manager
analysis scan tools Manager, Solaris software, VERITAS Volume
which Bandwidth Manager 3.1.1, VERITAS
enhance the Manager, Sun File System 3.4, Sun
diagnosis and MC 3.0, Cluster 3.0
testability of VERITAS
Superdome. Volume
Superdome Manager 3.1.1,
Partition VERITAS File
Manager - System 3.4, Sun
which allows Cluster 3.0
users to
launch as GUI
from SAM,
create and
modify
partitions and
display a
complete
hardware
inventory.
Service
Control -
provides
increased
efficiency
through
multi-system
management
tools.
Capacity On Yes Yes Yes Yes Yes
Demand
Clustering IBM eServer Yes Yes Yes Yes
Cluster 1600