Goodman and Amana by HC11121407527

VIEWS: 17 PAGES: 25

									Goodman and Amana
    Furnace Orientation
Complete Line of Furnaces




 80% AFUE      92 - 95% AFUE
      Nomenclature / Summary
G     M     S     8     045       3     A        N        A
1st   2nd   3rd   4th    5th      6th   7th     8th       9th

            GKS9        GMH8/95   GME8        GMV95
            GMS/GDS8    GDH8/GCH9             GCV9



                                              AMV8
                        AMH8/95
                                              ADV8/ACV9
  Goodman Single Stage (S)
• Patented Aluminized Tubular
  Heat Exchanger
• Stainless Steel Secondary
  Heat Exchanger – 92% Models
• Norton Mini-Igniter
• Self Diagnostics LED
• Four Speed PSC Motor
• Upflow / Horizontal
• Downflow – 80% only
  Goodman Two Stage (H)
• Aluminized Heat Exchanger
• Stainless Steel Secondary HE
  – 93% to 95% Models
• Single or Two Pipe Flue – 90%
• Silicon Nitride Igniter
• Stored Self Diagnostics
• Two Stage Gas Valve
• Upflow / Horizontal /
  Downflow
Don’t Take Our Word For It
    Goodman Two Stage (V)
•   Aluminized Heat Exchanger
•   90% Models Only
•   Variable Speed Motor – ECM
•   Premium SEER Model
•   Color Coded Connections
•   Silicon Nitride Igniter
•   Self Diagnostics LED
•   Upflow, Downflow &
    Horizontal Models Available
      ECM Motor (V Models)
• Low Power Consumption
• Virtually Unlimited Speed
  Options
• Dip Switch Speed
  Orientation Set-Up
• Designed To Overcome
  System Static
• Future Models Allow
  Communication Features
ECM vs. PSC
      Coming Attractions – 80%

                         • Impacts The
                           Entire 80% Line
                         • Same
                           Features, Just
39”              33-1/3”
                           Shorter
                         • 1st & 2nd
                           Quarters -
                           2009
    Amana Two Stage (H)
• Stainless Steel Tubular
  Primary Heat Exchanger
• SS Secondary HE – 90%
• Single or Two Pipe Flue
• Silicon Nitride Igniter
• Stored Self Diagnostics
• Two Stage Gas Valve
• Upflow / Horizontal
    Amana Two Stage (V)
• Stainless Steel Tubular
  Primary Heat Exchanger
• 80% & 90% Models
• Variable Speed Motor – ECM
• Color Coded Connections
• Silicon Nitride Igniter
• Self Diagnostics LED
• Upflow, Downflow &
  Horizontal Models Available
Unit Replacement Warranties
The Competition
 Wrinkle-Bend Technology
• Manufacturing
  Stress Including
  Wall-thinning Is
  Minimized
• Wrinkles Promote
  Turbulence To Aid
  Heat Transfer
  Efficiency
Dual-Diameter Muffler-Joint
• The Large Tube Fits
  Inside The Small Tube
• Tubes Are Solidly
  Joined With A Crimping
  Process
• Thermal Growth
  Ensures A Tight Seal
• Combustion Air
  Velocity Is Optimized
• Efficiency Is Maximized
             Clamshell Design




Carrier Clamshell   Lennox Clamshell   Trane Clamshell


 • Some Competitors Still Use Clamshell
 • But Why?
 The Best Heat Exchanger
 ANSI.Z21.47 Test Began
  in 1995
 Repeated Thermal Cycles
  From 200F To 1,100F
 As of August 2008 the
  Million-Air Heat
  Exchanger Achieved
  1,929,000 Cycles
 That’s More Than 38         Guess when the Amana heat
                             exchanger hits 2 million cycles
  Times Better Than Trane   for a chance to win big prizes at
 And It’s Still Going!          www.amana-hac.com!!!



                            Goodman HE – 25,510
120-Volt SiNi Ignition System
• All Models Except Value
  Models (GMS And GKS)
• Most Durable And Reliable
  Igniter In The Industry
• Seven Times Stronger Than
  Silicon Carbide
• More Reliable Than 90-volt
  Sini
• Less Sensitive To Grounding
Selectable Single or Two-Stage

Furnace Ships as a
 Single-Stage Unit
Flip This Switch To
 Activate 2-Stage
     Operation




 This Switch Adjusts
  Low-Stage Timing
 Between 5 Minutes
    Fixed or Self-
   Adjusting Mode
  Self-Adjusting Low-Stage
                     Call For Heat                 Call Satisfied



  Self-       High


Adjusting
Low-Stage     Low                    1 to 12 min

                              Cold = 1 min
              Off
                              Mild = 12 min

                     Call For Heat                 Call Satisfied


              High
                                                              This Switch Adjusts
                                                               Low-Stage Timing
Fixed 5 min
                                                                5 Minutes Fixed
Low-Stage     Low          5 min
                                                                       Or
                                                                 Self-Adjusting

              Off
Stored Diagnostics (Last Five Faults)


 Push and Hold
  Button For 2
   Seconds




LED Flashes Out Last
 5 Diagnostic Codes
 Most Recent Fault is
  Displayed First and
 Least Recent Fault is
    Displayed Last
  Low Constant Fan Mode
• All AMH & GMH Furnaces
  Have Three Operational
  Speeds:                       Low Heat
  – Cooling – High Stage Cool
  – High Heat – High Stage
    Heating                     Cooling
  – Low Heat - Comes On When
    The Furnace Operates On     High Heat
    Low-Stage Or Constant Fan
    Speeds
Color-Coded, Low-Voltage Label

• Featured On All Goodman and Amana Models
  Except Value Models (GMS8-B & GKS9)
• Reduces The Chances of Wiring Error
   Goodman Quality

  Compare Us To The Competition And
       You’ll Be Convinced…




Why Pay More For Less?

								
To top