Partner: Unique automation

Model: Bathomatic

Device Type: Jacuzzi Controller





GENERAL INFORMATION:

SIMPLWINDOWS NAME: Unique automation Bathomatic v1.0.umc





CATEGORY: Pool/Jacuzzi Controller





VERSION: v1.0





SUMMARY: The module allows controlling the Bathomatic system from Unique Automation.





The communication between Crestron and the Bathomatic system is made by IP on

telnet port 23.

Module functionality:

- Fill / Pause / Empty Bath

- Set Temperature, Depth and dispensers settings of a new bath

- Save/Recall 1-9 Presets

- if a preset is recalled and the bath is not empty, the bath will be emptied and

GENERAL NOTES: then the bath will be filled with the preset settings.

!!!! IMPORTANT !!!

After a connection is made, the digital input “Start up procedure” needs to be

triggered. This function retrieves current values, the names and settings of the 9

presets, turns auto update (life feedback) on and retrieves the names of the 8

different dispensers.

!!!! IMPORTANT !!!







CRESTRON HARDWARE REQUIRED: 2-Series Processor with an Ethernet connection.





SETUP OF CRESTRON HARDWARE: Pro2 processor with an Ethernet card. The connection is made on port 23.



VENDOR FIRMWARE: BOM2 Protocol 1.0.0.2





VENDOR SETUP: Bathomatic connected to the web. The connection is made on port 23.

Partner: Unique automation

Model: Bathomatic

Device Type: Jacuzzi Controller



CONTROL:

Trigger Start Up Procedure D Pulse to trigger the start up procedure.



Show Presets Page D Pulse to show the presets page.



Show Dispensers Page D Pulse to show the dispensers page.



Show Settings Page D Pulse to show the settings page.



Fill Bath D Pulse to start filling the bath with current depth/temp and dispensers settings.



Pause Bath D Pulse to pause the bath.



Empty Bath D Pulse to empty the bath.



New Bath Temperature Up D Pulse to increase the temperature value of the new bath.



New Bath Temperature Down D Pulse to decrease the temperature value of the new bath.



New Bath Depth Up D Pulse to increase the Depth value of the new bath.



New Bath Depth Down D Pulse to decrease the Depth value of the new bath.



Show Preset X D Pulse to show the settings of Preset X.



Load Selected Preset D Pulse to load the settings of the selected preset and start filling the bath.



New Bath DispX up D Pulse to increase the value of dispenser X.



New Bath DispX down D Pulse to decrease the value of dispenser X.



Save On Preset X D Pulse to save current settings on preset X.



Connect D Pulse to start/stop the connection with the Bathomatic system.



{{TCP/IP_Client_>>_Connect-F}} D Needs to be connected to the Connect-F output of the TCP/IP Client.



{{TCP/IP_Client_>>_status}} A Needs to be connected to the Status output of the TCP/IP Client.



{{TCP/IP_Client_>>_RX$}} S Needs to be connected to the RX$ output of the TCP/IP Client.

Partner: Unique automation

Model: Bathomatic

Device Type: Jacuzzi Controller



FEEDBACK:

Presence detected D High to indicate that presence is detected.



Plug Is Closed D High to indicate that the plug is closed.



Presets Page is selected D High to indicate that the Presets page is selected.



Dispensers Page is Selected D High to indicate that the Dispensers page is selected.



Settings Page is selected D High to indicate that the Settings page is selected.



Bath filling D High to indicate that the bath is filling.



Bath is Paused D High to indicate that the bath is Paused.



Bath is Emptying D High to indicate that the bath is Emptying.



New Bath Temperature A Analog output containing the new bath temperature value.



Bath Depth animation value A Analog output containing the bath depth animation value.



Preset X is selected D High to indicate that preset X is selected.



Preset is Saved D High for 2 seconds to indicate that the preset is saved.



New Bath DispX A Analog output containing the value of dispenser X.



Shower status A Analog output containing the shower status.



Shower flow A Analog output containing the shower flow.



Shower temp A Analog output containing the temperature of the shower.



Active preset nr A Analog output containing the number of the active preset.



Preset desired temp A Analog output containing the value of the desired temp of the selected preset.



Preset desired depth A Analog output containing the value of the desired depth of the selected preset.



Current temp A Analog output containing the value of the current temperature.



Current depth A Analog output containing the value of the current depth



Bathomatic status A Analog output containing the status of the Bathomatic system.



Current temp str S Serial value containing the value of the current temperature.

Partner: Unique automation

Model: Bathomatic

Device Type: Jacuzzi Controller



Current depth str S Serial value containing the value of the current depth.



Bathomatic Text status S Serial value containing the Bathomatic status.



Name Dispenser[X] S Serial value containing the name of dispenser X.



Preset Name[X] S Serial value containing the name of preset X.



Connect-F D High to indicate that the system is connected.



Status A Analog value containing the status of the connection.



{{Connect_>>_TCP/IP_Client}} D Needs to be connected with the Connect input of the TCP/IP Client.



{{TX$_>>_TCP/IP_Client}} S Needs to be connected with the TX$ input of the TCP/IP Client.









PARAMETERS:

Port number A Contains the value of the connection port.









TESTING:

OPS USED FOR TESTING: PRO2 4.001.1011 (Feb 10 2009)



SIMPL WINDOWS USED FOR TESTING: v2.11.27

CRESTRON DB USED FOR TESTING: v21.00.004.00



DEVICE DB USED FOR TESTING: v24.05.004.00



SAMPLE PROGRAM: Unique automation Bathomatic v1.0 PRO2 DEMO.smw



REVISION HISTORY: v. 1.0



Related docs
Other docs by qinmei liao
Translator
Views: 1  |  Downloads: 0
Circular no CuR June Introduction of
Views: 1  |  Downloads: 0
Post Thiopental Tremors
Views: 1  |  Downloads: 0
Antivirals
Views: 1  |  Downloads: 0
Participles
Views: 9  |  Downloads: 0
Caring for your Child
Views: 6  |  Downloads: 0
Section One Inspiration
Views: 1  |  Downloads: 0
By registering with docstoc.com you agree to our
privacy policy

You are almost ready to download!

You are almost ready to download!