NPARKS-0-DCS06

CHECKLIST FOR DC SUBMISSION - PEDESTRIAN OVERHEAD BRIDGE,

COVERED LINKWAY

Applicable

Not

Standard Requirements Complied Not Complied Applicable

With With

1 General



The plans should comprise :

a) Key and location plans of scale 1 : 10,000 or 1

: 5,000 showing access to the site from the

street or road

b) Site plan (scale 1 : 500, 1 : 200 and 1 : 100)



c) Address, lot and/or plot number of the

development site and neighbouring lots

d) Location of the proposed pedestrian overhead

bridge/covered linkway

e) Cross section of proposed pedestrian

overhead bridge and troughs (scale 1 : 50 or

1: 100)

f) Cross section of proposed covered linkway

(scale 1 : 50 or 1: 100)



g) The registered architect will submit a

completed NParks submission form, sign all

layers of drawings digitally and enclose the

letter of authorization from the developer

2 Site plan should show :

a) Alignment of proposed overhead bridge, the

spans of the proposed planting troughs and

schematic engineering drawing (with

dimensions) of the pedestrian overhead bridge

and foundation.



b) Alignment of proposed covered linkway and

schematic engineering drawing (with

dimensions) of the covered linkway



c) Development boundary verged in red





d) Road reserve lines/width of existing/proposed

roads (verged in red)



e) Existing and proposed road sidetable levels.





f) Location and dimensions of carriageway,

roadside drain, existing/proposed roadside

planting verge (coloured green), service verge

(coloured green) and footpath.









DC CH-LIST POB/COVERED LINKWAY 10/12/2011 at 10:57 PM Page 1 of 5

CHECKLIST FOR DC SUBMISSION - PEDESTRIAN OVERHEAD BRIDGE,

COVERED LINKWAY

Applicable

Not

Standard Requirements Complied Not Complied Applicable

With With

g) Location of existing and proposed lamp posts,

OG boxes, SCV boxes, manholes, sewer lines,

electrical posts, fire hydrants, traffic lights,

authorised signs, etc.

(If no new OG box is required, to attach a

confirmation letter from PowerGrid.)



h) Locations of proposed fire engine

hardstandings (if applicable)





i) The clearance from a road element to the

centre of a tree/palm should be indicated on the

site plan.



j) Location of proposed water tanker lay-by, as

approved at pre-consultation stage.



k) Planting beds beneath pedestrian overhead

bridge staircases are coloured green on plan.

l) Layout plan and cross sectional drawing

should show :

 Boundary line, road reserve line,

carriageway, roadside drain, tree planting

verge, service verge and footpath with

dimensions. Existing carriageway, roadside

drain, planting verge and footpath to be

demolished in yellow broken line.

 Details of footings and their clearance from

existing trees and roadside drain



 Roof dimension and their clearance from

existing trees

 Depth and types of existing/proposed

underground services

3 Existing Roadside Trees / Palms / Shrubs

3.1 Trees / palms /shrubs abutting the site

boundary and up to 10m on both sides of the

boundary are shown on plan with :

a) species

b) girth (tree / single stem palm) –

measured 1.0m from the ground

c) height (if available) and number of cluster

palm / shrub





3.2 Trees / single stem palms are uniquely

numbered and are consistent throughout the

project. No prefix is attached.





DC CH-LIST POB/COVERED LINKWAY 10/12/2011 at 10:57 PM Page 2 of 5

CHECKLIST FOR DC SUBMISSION - PEDESTRIAN OVERHEAD BRIDGE,

COVERED LINKWAY

Applicable

Not

Standard Requirements Complied Not Complied Applicable

With With

3.3 The trees / single stem palms are indicated in

the Tree Survey Information Form. Clear

photographs are provided, if available.



3.4 The colour code for existing trees/ palms/

shrubs is as follows:



Status of existing trees / palms / Outlined

shrubs in colour

a. to be retained green

b. to be removed yellow

c. removed without written red

approval

d. removed with written *yellow

approval

*yellow – indicate the approved date in tree

schedule

non-existence after inspection – indicate a

‘cross’ on tree symbol



3.5 For existing trees / palms on footpath, the

existing unpaved areas and loose paved PC

slabs around the trees are to be shown.





4 Retention Of Roadside Trees / Single

Stem Palms



The following proposed elements are positioned at

the minimum required distance from the centre of

a tree / single stem palm :



4.1 Proposed linkway/pedestrian overhead

bridge column footings



Tree / single stem palm Distance

a) single stem palm  1.0m

b) small to medium sized tree  1.5m

c) large tree  2.5m



4.2 Proposed linkway roof eaves to the lowest

branching of a tree



Tree Distance

All trees at least 0.3m



4.3 External wall of roadside drain and road kerb



Tree / single stem palm Distance

a. single stem palm  0.8m

b. small to medium sized tree  0.8m

c. large tree  1.5m



DC CH-LIST POB/COVERED LINKWAY 10/12/2011 at 10:57 PM Page 3 of 5

CHECKLIST FOR DC SUBMISSION - PEDESTRIAN OVERHEAD BRIDGE,

COVERED LINKWAY

Applicable

Not

Standard Requirements Complied Not Complied Applicable

With With

4.4 Scupper pipe / drain



Tree / single stem palm Distance

a. single stem palm  1.0m

b. small to medium sized tree  1.5m

c. large tree  2.5m



4.5 Lamp post

Tree / single stem palm Distance

a. single stem palm  4.0m

b. small to medium sized tree  4.0m

c. large tree  6.0m





4.6 OG box, manholes, sewer line, electrical post,

fire hydrant, SCV box, lighting control box,

traffic control box and traffic light

Tree / single stem palm Distance

a. single stem palm  2.0m

b. small to medium sized tree  2.0m

c. large tree  2.5m



4.7 Cement crossing (e.g. pushcart ramp for bin

centre)

Tree / single stem Palm Distance

All trees and single stem palms  1.5m



* Depending on the root spread, especially for tree

with girth more than 2.0m, larger tree protection

zone will be determined at site on case by case

basis









5 Lay-By For Water Tanker

5.1 A lay-by of 23m long and 3m wide is provided

for water tanker, unless there is a paved

shoulder. (A letter from Land Transport

Authority indicating no objection for the use of

paved shoulder is attached)

5.2 Location of the water tanker lay-by is within a

radius of 8m from the coupling point (at the

column of the bridge or housed in a pit) to the

mid- point of the lay-by.







DC CH-LIST POB/COVERED LINKWAY 10/12/2011 at 10:57 PM Page 4 of 5

Footnote:



1. All building activities and construction materials are to be confined within the project site and not

encroached onto the road sidetables.

2. Please apply to Streetscape Division of NParks regarding those roadside trees that require

pruning of tree branches / roots (girth more than 200mm) to accommodate construction

activities.

Address:

Streetscape Division

Headquarters (Raffles Building)

Singapore Botanic Gardens

1 Cluny Road

Singapore 256569

Tel: (65) 64717808, Telefax: (65) 67621383









DC CH-LIST POB/COVERED LINKWAY 10/12/2011 at 10:57 PM Page 5 of 5



Other docs by panniuniu
organization_of_slp_working_files_3-23-10
Views: 1  |  Downloads: 0
Lesson 2 2011 key
Views: 0  |  Downloads: 0
Site Survey
Views: 2  |  Downloads: 0
alt energy project SP11
Views: 1  |  Downloads: 0
Effie Biography
Views: 0  |  Downloads: 0
Download-Organization-application-letter
Views: 0  |  Downloads: 0
TWIN_Nomination_form_2010
Views: 0  |  Downloads: 0
Engineering Change Order Master Log
Views: 2  |  Downloads: 0
360654.f1
Views: 0  |  Downloads: 0
By registering with docstoc.com you agree to our
privacy policy

You are almost ready to download!

You are almost ready to download!