NPARKS-0-DCS03

CHECKLIST FOR DC SUBMISSION - CONVENTIONAL HOUSING

DEVELOPMENT WITH OPEN SPACE PROVISION

Applicable

Not

Standard Requirements Complied Not Applicable

With Complied

With

1 General



(a) The following plans are provided:



 Key and location plans of scale 1 : 10,000 or

1 : 5,000 showing access to the site from the

street or road

 Site plan of scale 1 : 500, 1 : 200 or 1 : 100

 Address, lot and/or plot number of the

development site and neighbouring lots



 Survey plan (survey done less than 2 years at

the point of application and endorsed by a

qualified surveyor)

(b) The registered architect will submit a completed

NParks submission form, sign all layers of

drawings digitally and enclose the letter of

authorization from the developer

(c) The scale of all plans is correctly indicated



(d)  The following are shown on site plan:-

 Development boundary verged in red

 Proposed development layout

 Existing and proposed road reserve line

verged in red

 Width of proposed road reserve

 Length of roadside planting verges



 Category of existing and proposed roads

 Existing and proposed levels of the site

including the open space

 Proposed open space location verged in red



 Area of open space



 Walking distance of the furthest house unit to

the open space









DC CH-LIST OS 10/12/2011 at 10:55 PM Page 1 of 7

CHECKLIST FOR DC SUBMISSION - CONVENTIONAL HOUSING

DEVELOPMENT WITH OPEN SPACE PROVISION

Applicable

Not

Standard Requirements Complied Not Applicable

With Complied

With

2 Conservation Of Trees / Single Stem Palms

Within Development Site

(only applicable if the development is within

the gazetted Tree Conservation Area or on

vacant land)

2.1 The site and survey plans show :

Existing trees / single stem palms within the

development boundary and up to 5m from

the boundary

a) species

b) girth – measured 0.5m from the ground

c) height (if available)

d) all trees / single stem palms should be

uniquely numbered and consistent

throughout the project





2.2 All existing trees / single stem palms

indicated on the survey plan are reflected in

the Tree Survey Information Form.

2.3 The colour code for existing trees / palms is

as follow:

Status of existing trees Outlined in color

/ palms



a. to be retained green

b. to be removed yellow

c. removed without red

written approval

d. removed with

written approval *yellow

*yellow – indicate the approved date in the

tree schedule

Non-existence after inspection – indicate a

‘cross’ on tree symbol

2.4 Clear photographs of trees / single stem

palms proposed for conservation are

attached. The photograph show the entire

height of the tree(s)

2.5 The trees / single stem palms in the

photographs are numbered according to the

numbering shown on plan









DC CH-LIST OS 10/12/2011 at 10:55 PM Page 2 of 7

CHECKLIST FOR DC SUBMISSION - CONVENTIONAL HOUSING

DEVELOPMENT WITH OPEN SPACE PROVISION

Applicable

Not

Standard Requirements Complied Not Applicable

With Complied

With

2.6 Tree Protection Zone (TPZ) for retained

tree/single-stem palm





2.6.1 The minimum protection zone from

centre of tree/single-stem palm is

provided in accordance to the table

below





Girth *Minimum protection

zone

a.  1.0m 2.0m

b. > 1.0m but  1.5m 3.0m

c. > 1.5m but  2.0m 4.0m

d. > 2.0m 5.0m



Depending on the root spread, especially for tree

with girth more than 2.0m, larger tree protection

zone will be determined at site on case by case

basis

2.6.2 Hoarding is to be provided along the

limits of the protection zone around

the tree. There must be no excavation,

raise/lower of soil level, compaction

and any form of construction including

temporary works within the hoarded

area)

No dumping of excavated materials

and/or storage of construction

materials is allowed within the Tree

Protection Zone





Retention Of Roadside Trees / Palms / Shrubs

3 3.1 The site and survey plans show :



Roadside trees / palms / shrubs abutting the

development boundary and up to 10m on

both sides of the boundary

a) species

b) girth – (tree / single stem palm) measured

1.0m from the ground

c) height (if available) and number of cluster

palm / shrub

d) all trees / palms should be uniquely

numbered and consistent throughout the

project







DC CH-LIST OS 10/12/2011 at 10:55 PM Page 3 of 7

CHECKLIST FOR DC SUBMISSION - CONVENTIONAL HOUSING

DEVELOPMENT WITH OPEN SPACE PROVISION

Applicable

Not

Standard Requirements Complied Not Applicable

With Complied

With

3.2 All existing trees / palms / shrubs indicated

on the survey plan are reflected in the Tree

Survey Information Form

3.3 The colour code for existing trees / palms /

shrubs is as follow:

Status of existing trees Outlined in color

/ palms / shrubs



a. to be retained green

b. to be removed yellow

c. removed without red

written approval

d. removed with

written approval *yellow

*yellow – indicate the approved date in the

tree schedule

Non-existence after inspection – indicate a

‘cross’ on tree symbol

3.4 The following proposed element is

positioned at the minimum required distance

from the centre of a tree:

3.4.1 Splay corner of an entrance culvert

(include access to bin centre, substation,

MDF room and fire engine access):









Tree / Palm Distance



a. Palm  1.0m

b. Small to medium  1.5m

tree

 2.5m

c. Large tree

3.4.2 Cement crossing (e.g. pushcart ramp for

bin centre) across roadside green verge

and centre of an existing tree / palm is at

least 2.0m





Depending on the root spread, especially for tree

with girth more than 2.0m, larger tree protection

zone may be required on case by case basis









DC CH-LIST OS 10/12/2011 at 10:55 PM Page 4 of 7

CHECKLIST FOR DC SUBMISSION - CONVENTIONAL HOUSING

DEVELOPMENT WITH OPEN SPACE PROVISION

Applicable

Not

Standard Requirements Complied Not Applicable

With Complied

With

4 Proposed Open Space



4.1 Area of open space

The area of open space is computed based

on the formula stipulated by URA

4.2 Location

4.2.1 The walking distance from the furthest

unit to the proposed open space

measured along the road centre, is not

more than 250m

4.2.2 The proposed open space does not

abut a major road and/or park

connector that is abutting a major

road

4.2.3 The open space does not abut an

existing/proposed retaining wall.

4.2.4 The opens space is located such that

at least 2 sides face the front of a

house(s), and none face the rear of a

house(s).

4.2.5 If the proposed development is

adjacent to a proposed or existing

Park Connector,



a. The open space is to abut the

Park Connector provided the

Park Connector is not abutting a

major road and it complies with

clause 4.2.1.

4.3 Accessibility



4.3.1 At least one of the boundaries of the

open space abuts an existing minor

road or a new local access road

4.3.2 Proposed entrance or access path

to the open space is at least 4.0m

wide

4.3.2 The open space is of a regular

shape with a width of at least 30m



4.4 Terrain of the open space



4.4.1 The open space should generally be

flat (gradient 1: 40). If site situation

does not permit the proposed slope

should not be steeper than 1:2.5 and

appropriate measures for slope

stability should be carried out.

4.4.2 The gradient of all proposed slopes

are shown



DC CH-LIST OS 10/12/2011 at 10:55 PM Page 5 of 7

CHECKLIST FOR DC SUBMISSION - CONVENTIONAL HOUSING

DEVELOPMENT WITH OPEN SPACE PROVISION

Applicable

Not

Standard Requirements Complied Not Applicable

With Complied

With

4.4.3 The level of open space should be

the same as that of adjacent road(s)

and neighbouring lot

4.4.4 Proper drainage system is provided

to prevent water ponding. (Endorsed

on plan).

Details of the system will be

commented at BP stage

4.4.5 The open space is free from

encumbrances above and below the

ground level (Endorsed on plan)

4.5 Others



4.5.1 The open space is not fragmented by

any structures e.g. a canal, road, or

infrastructure

4.5.2 Proposed retaining walls are not

located within open space

5 Proposed SWA Section 18 Roads

5.1 The length of planting island is at least 6.0m

long. The proposed driveways to private lot

abut each other

5.2 Planting island which is  6.0m long is

indicated

5.3 The width of the roadside planting verges are

provided in accordance with LTA standard

road code

5.4 Clearance between proposed cement crossing

(e.g. push cart ramp for bin centre) across

roadside planting verge and the centre of an

existing tree / palm is at least 2.0m.



5.5 No underground services are allowed to be

laid within the roadside planting verges.

Services that are required to transverse

through a planting island into a proposed

building plot are laid at least 2.0m away from

the centre of a tree / palm.





Depending on the root spread, especially for tree

with girth more than 2.0m, larger tree protection

zone may be required on case by case basis







Footnote:









DC CH-LIST OS 10/12/2011 at 10:55 PM Page 6 of 7

1. All building activities and construction materials are to be confined within the project site and

not encroached onto the road sidetables.



2. Please apply to Streetscape Division of NParks regarding those roadside trees that require

pruning of tree branches / roots (girth more than 200mm) to accommodate construction

activities.

Address:

Streetscape Division

Headquarters (Raffles Building)

Singapore Botanic Gardens

1 Cluny Road

Singapore 256569

Tel: (65) 64717808, Telefax: (65) 67621383









DC CH-LIST OS 10/12/2011 at 10:55 PM Page 7 of 7



Other docs by panniuniu
organization_of_slp_working_files_3-23-10
Views: 1  |  Downloads: 0
Lesson 2 2011 key
Views: 0  |  Downloads: 0
Site Survey
Views: 2  |  Downloads: 0
alt energy project SP11
Views: 1  |  Downloads: 0
Effie Biography
Views: 0  |  Downloads: 0
Download-Organization-application-letter
Views: 0  |  Downloads: 0
TWIN_Nomination_form_2010
Views: 0  |  Downloads: 0
Engineering Change Order Master Log
Views: 2  |  Downloads: 0
360654.f1
Views: 0  |  Downloads: 0
By registering with docstoc.com you agree to our
privacy policy

You are almost ready to download!

You are almost ready to download!