This document will guide you through the set-up and installation of Miranda
iControl Solo and IC-USB (if required). Please follow the steps and make sure
you meet the recommended requirements. (See details below)
Recommended PC Requirement:
Pentium 4 1.5GHz, 512 Meg RAM, 100 Meg of free space on the hard drive.
Windows XP professional
USB port (for imaging)
Ethernet NIC (for Densité; Densité controller requires the ETH option)
1024x768 display resolution or better
Operating System: iControl Solo will run on Windows XP Professional only
Software Installation:
DO NOT INSTALL OR CONNECT FRAMES TO YOUR PC BEFORE YOU HAVE
FINISHED INSTALLING THE SOFTWARE.
Insert the “Miranda iControl Solo” installation CD in your CR-ROM drive. After
a few seconds, the installation application will automatically start.
Follow the instructions provided during the software installation
Connect frames to your PC. See instructions “How to Connect Imaging &
Densité Frames”
Run “iControl Solo” application
Configure Densité & Imaging frames to iControl solo. See “How to Configure
your Densité and imaging frames”
8565113b-6a42-4903-a2fb-886fa7ad439a.DOC
How to connect imaging and Densité frames:
Connecting Densité frames through an Ethernet Router and Symphonie and
Quartet 2 frames through the IC-USB
Ethernet 1
Ethernet
Router
Ethernet 2
USB
Customer IC-USB
Supplied Adapter
PC with Miranda (Optional)
iControl SOLO Max 4 frames
on chain
installed
Max: 100 cards
Connecting to a single Densité frame without an Ethernet Router
Requires CROSS OVER
cable
Ethernet
8565113b-6a42-4903-a2fb-886fa7ad439a.DOC
How to configure your Densité and imaging frames
in Miranda iControl Solo
Configuring a Densité Frame
1) Start the Miranda iControl Solo application
2) Double click on “DENSITÉ MANAGER”
Double Click on
« Densité Manager »
3) In the “Densité Manager” window, you can see the frames assigned to
Miranda iControl Solo. In this menu you can: Add, Remove or put a frame
on Standby.
To assign a Densité frame click the “Add” button
8565113b-6a42-4903-a2fb-886fa7ad439a.DOC
4) Enter the Densité Frame IP address and name in the identified section
and click “OK” when finished. Your frame has been assigned to Miranda
iControl Solo.
8565113b-6a42-4903-a2fb-886fa7ad439a.DOC
Configuring imaging Frames (Quartet2 & Symphonie)
1) Start the Miranda iControl Solo application
2) Double click on “imaging Communicator”
Double Click on « imaging
Communicator »
3) Select the “COM Port” as per IC-USB driver installation
4) Click on “online” to activate port and frames connected to the RS422 port
Note: All frames connected to the RS422 will be activated together .